SourceMed · Shelf #8417 in the ask interface

Optic-nerve-sheath-diameter ultrasound for raised intracranial pressure — the test rules out far better than it rules in: negative likelihood ratios 0.04–0.09 against positive LRs of about 5–7 across the 2011, 2018 and 71-study 2019 syntheses; optimal cut-off 5.0 mm; 3 overlapping syntheses

Shelf #8417 · Critical care & sepsis

PREDICTIVE PERFORMANCE — a normal sheath diameter rules raised intracranial pressure out far better than an enlarged one rules it in, consistently across three overlapping syntheses: 2011 pool (6 studies / 231 patients against ICP monitoring) sensitivity 0.90 (95% CI 0.80–0.95), specificity 0.85 (0.73–0.93), diagnostic odds ratio 51 (22–121), summary ROC area 0.94 (0.91–0.96); 2018 adult pool (7 prospective studies / 320 patients against invasive devices, raised ICP >20 mmHg or >25 cmH₂O) diagnostic odds ratio 67.5 (29–135), positive LR 5.35 (3.76–7.53), negative LR 0.088 (0.046–0.152), hierarchical summary ROC area 0.938, with 3 of 7 studies at high risk of bias; 2019 pool (71 studies / 4,551 patients) in traumatic brain injury sensitivity 97% (92–99), specificity 86% (74–93), positive LR 6.93 (3.55–13.54), negative LR 0.04 (0.02–0.10), in non-traumatic injury 92% (86–96) / 86% (77–92), LR+ 6.39, LR− 0.09, optimal cut-off 5.0 mm — reference standards and raised-ICP thresholds vary across the pooled primaries and print with the figures

Stamped: 2026-11-28.

Evidence published: 2011–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In critically ill adults and children, how accurately does bedside optic-nerve-sheath-diameter ultrasonography detect raised intracranial pressure against invasive monitoring or other reference standards — in the 2011 meta-analysis, the 2018 adult meta-analysis, and the 71-study 2019 meta-analysis?

Balance of the evidence

3 reports, all syntheses, and they overlap — the 2019 pool (71 studies) subsumes most of the earlier pools (6 and 7 studies) — printed as overlapping syntheses, never as three independent confirmations: Dubourg 2011, Robba 2018 (adults, invasive reference) and Koziarz 2019 (adults and children, any reference standard). No report was refused. None of the syntheses evaluates effect on clinical outcomes, as the 2019 authors state. Cross-point in prose only: normal optic-nerve-sheath reference values are homed at pack #7546 (a physiology reference-values pack giving no accuracy figures).

MeSH: Humans · Intracranial Hypertension/diagnostic imaging*,physiopathology · Intracranial Pressure/physiology · Myelin Sheath/diagnostic imaging* · Optic Nerve/diagnostic imaging*,physiopathology · Ultrasonography · Adult · Intracranial Hypertension*/diagnostic imaging · Intracranial Pressure* · Optic Nerve*/anatomy & histology,diagnostic imaging · Prospective Studies · Sensitivity and Specificity · Brain Injuries/complications,diagnostic imaging · Child · Data Interpretation, Statistical · Intracranial Hypertension/diagnosis,diagnostic imaging*,etiology · Intracranial Pressure · Optic Nerve/diagnostic imaging* · Point-of-Care Testing* · Predictive Value of Tests · Ultrasonography*/methods

Cards (4)

Card 1 — First meta-analysis (Dubourg 2011, Intensive Care Medicine — 6 studies / 231 patients against ICP monitoring): pooled sensitivity 0.90 (95% CI 0.80–0.95), specificity 0.85 (0.73–0.93), diagnostic odds ratio 51 (22–121), summary ROC area 0.94 (0.91–0.96)

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 231 patients in 6 studies comparing ultrasonography of optic nerve sheath diameter with intracranial pressure monitoring; no significant heterogeneity was detected for sensitivity, specificity, likelihood ratios or diagnostic odds ratio.

Summary: First meta-analysis (Dubourg 2011, Intensive Care Medicine — 6 studies / 231 patients against ICP monitoring): pooled sensitivity 0.90 (95% CI 0.80–0.95), specificity 0.85 (0.73–0.93), diagnostic odds ratio 51 (22–121), summary ROC area 0.94 (0.91–0.96)

Result: For detection of raised intracranial pressure, pooled sensitivity was 0.90 (95% CI 0.80–0.95), pooled specificity 0.85 (0.73–0.93), the pooled diagnostic odds ratio was 51 (22–121) and the area under the summary ROC curve was 0.94 (0.91–0.96), as published.

Watch out: The smallest and oldest pool (231 patients, literature to July 2010); its estimates are the least precise here and are subsumed by the later syntheses.

Source: Dubourg et al. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive care medicine. 2011. PMID: 21505900. Registry ID: none in the record. MeSH: Humans · Intracranial Hypertension/diagnostic imaging*,physiopathology · Intracranial Pressure/physiology · Myelin Sheath/diagnostic imaging* · Optic Nerve/diagnostic imaging*,physiopathology · Ultrasonography

Card 2 — Adult invasive-reference meta-analysis (Robba 2018, Intensive Care Medicine — 7 prospective studies / 320 adults, raised ICP >20 mmHg or >25 cmH₂O): pooled diagnostic odds ratio 67.5 (29–135), positive LR 5.35 (3.76–7.53), negative LR 0.088 (0.046–0.152), hierarchical summary ROC area 0.938; 3 of 7 studies at high risk of bias

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 320 adult patients in 7 prospective studies evaluating sonographic optic nerve sheath diameter against intracranial pressure measured with invasive intracranial devices, intracranial hypertension assumed at ICP >20 mmHg or >25 cmH₂O; a subset of 5 studies (275 patients) used the >20 mmHg definition. The review was registered on PROSPERO (CRD42018089137, printed in the abstract).

Summary: Adult invasive-reference meta-analysis (Robba 2018, Intensive Care Medicine — 7 prospective studies / 320 adults, raised ICP >20 mmHg or >25 cmH₂O): pooled diagnostic odds ratio 67.5 (29–135), positive LR 5.35 (3.76–7.53), negative LR 0.088 (0.046–0.152), hierarchical summary ROC area 0.938; 3 of 7 studies at high risk of bias

Result: The pooled diagnostic odds ratio, positive likelihood ratio and negative likelihood ratio were 67.5 (95% CI 29–135), 5.35 (3.76–7.53) and 0.088 (0.046–0.152); the area under the hierarchical summary ROC curve was 0.938. In the >20 mmHg subset: DOR 68.10 (26.8–144), positive LR 5.18 (3.59–7.37), negative LR 0.087 (0.041–0.158), AUHSROC 0.932. Study accuracy ranged from 0.811 to 0.954, and 3 studies were at high risk of bias, as published. The record prints no pooled sensitivity/specificity pair, and none is printed from this anchor.

Watch out: The wide interval on the pooled diagnostic odds ratio (29–135) is the authors' own caution flag, and nearly half the small pool was at high risk of bias.

Source: Robba et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive care medicine. 2018. PMID: 30019201. Registry ID: none in the record. MeSH: Adult · Humans · Intracranial Hypertension*/diagnostic imaging · Intracranial Pressure* · Optic Nerve*/anatomy & histology,diagnostic imaging · Prospective Studies · Sensitivity and Specificity · Ultrasonography

Card 3 — 71-study meta-analysis (Koziarz 2019, Annals of Internal Medicine — 71 studies / 4,551 patients, 35 rated low risk of bias): traumatic brain injury sensitivity 97% (92–99), specificity 86% (74–93), positive LR 6.93 (3.55–13.54), negative LR 0.04 (0.02–0.10); non-traumatic 92% (86–96) / 86% (77–92), LR+ 6.39, LR− 0.09; optimal cut-off 5.0 mm

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 4,551 patients in 71 prospective diagnostic-accuracy studies (61 including adults), any age group and any reference standard; 35 studies were rated as having low risk of bias. The review was registered on PROSPERO (CRD42017055485, printed in the abstract).

Summary: 71-study meta-analysis (Koziarz 2019, Annals of Internal Medicine — 71 studies / 4,551 patients, 35 rated low risk of bias): traumatic brain injury sensitivity 97% (92–99), specificity 86% (74–93), positive LR 6.93 (3.55–13.54), negative LR 0.04 (0.02–0.10); non-traumatic 92% (86–96) / 86% (77–92), LR+ 6.39, LR− 0.09; optimal cut-off 5.0 mm

Result: In traumatic brain injury, pooled sensitivity, specificity, positive and negative likelihood ratios were 97% (95% CI 92% to 99%), 86% (74% to 93%), 6.93 (3.55 to 13.54) and 0.04 (0.02 to 0.10). In non-traumatic brain injury: 92% (86% to 96%), 86% (77% to 92%), 6.39 (3.77 to 10.84) and 0.09 (0.05 to 0.17). Estimates were similar across strata of age, operator, reference standard, blinding and cut-off; the optimal cut-off for sheath dilatation was 5.0 mm, as published.

Watch out: Reference standards vary within this pool (not all invasive monitoring), small studies and possible publication bias are the authors' stated limitations, and no study evaluated effect on clinical outcomes — accuracy here is not outcome benefit.

Source: Koziarz et al. Bedside Optic Nerve Ultrasonography for Diagnosing Increased Intracranial Pressure: A Systematic Review and Meta-analysis. Annals of internal medicine. 2019. PMID: 31739316. Registry ID: none in the record. MeSH: Adult · Brain Injuries/complications,diagnostic imaging · Child · Data Interpretation, Statistical · Humans · Intracranial Hypertension/diagnosis,diagnostic imaging*,etiology · Intracranial Pressure · Optic Nerve/diagnostic imaging* · Point-of-Care Testing* · Predictive Value of Tests · Sensitivity and Specificity · Ultrasonography*/methods

Card 4 — Synthesis: optic-nerve-sheath ultrasound is an asymmetric test — a normal measurement argues strongly against raised ICP (negative LR 0.04–0.09) while an enlarged one only moderately supports it (positive LR ~5–7) — consistently across 3 overlapping syntheses totalling pools of 231, 320 and 4,551 patients

Study: Synthesis

Population: Pools as carded and overlapping: 6 studies / 231 patients (2011, ICP monitoring); 7 prospective studies / 320 adults (2018, invasive devices); 71 studies / 4,551 patients (2019, any reference standard). Raised-ICP thresholds vary (>20 mmHg, >25 cmH₂O, and mixed standards in the 2019 pool).

Summary: Synthesis: optic-nerve-sheath ultrasound is an asymmetric test — a normal measurement argues strongly against raised ICP (negative LR 0.04–0.09) while an enlarged one only moderately supports it (positive LR ~5–7) — consistently across 3 overlapping syntheses totalling pools of 231, 320 and 4,551 patients

Result: Sensitivity/specificity where printed: 0.90 / 0.85 (2011); 97% / 86% traumatic and 92% / 86% non-traumatic (2019). Likelihood ratios: positive 5.35 (2018), 6.93 traumatic / 6.39 non-traumatic (2019); negative 0.088 (2018), 0.04 / 0.09 (2019). Optimal cut-off 5.0 mm (2019). No report was refused. Cross-point in prose only: normal sheath reference values at pack #7546. The stamp is PREDICTIVE PERFORMANCE with the asymmetry and the threshold variation on its face.

Watch out: Do not quote the traumatic-brain-injury 97% sensitivity as the test's rule-in strength — the positive LR is only ~7 — and do not apply the 5.0 mm cut-off as if every pooled primary had used it.

Source: Synthesis of the reports carded above; no additional source.