SourceMed · Shelf #8420 in the ask interface

Rapid antigen detection tests for group A streptococcal pharyngitis — summary sensitivity 85.6% and specificity 95.4% in the Cochrane children's review (about 14 of 100 children with strep throat missed), with the health-technology assessment unable to identify any one of 21 point-of-care tests as most accurate; 3 syntheses pooling many devices as one class

Shelf #8420 · Eyes, skin, nose & allergy

PREDICTIVE PERFORMANCE — sensitivity is the weak direction everywhere (~86%) while specificity is high (~95–96%), on 3 syntheses that pool many commercial devices as one class: the Cochrane review in children (98 studies / 101,121 participants; main analysis 105 test evaluations / 58,244 children at median GAS prevalence 29.5%) gave summary sensitivity 85.6% (95% CI 83.3–87.6) and specificity 95.4% (94.5–96.2), enzyme and optical immunoassays comparable (85.4% vs 86.2% sensitivity), with poor overall study quality (high risk of bias in 73% of evaluations for patient selection) — about 14 of 100 children with strep throat missed; the health-technology assessment of 21 point-of-care tests found, in its score-filtered population of interest (Centor/McIsaac ≥3 or FeverPAIN ≥4), point estimates ranging 0.829–0.946 for sensitivity and 0.849–0.991 for specificity with considerable heterogeneity even for the same test and no test identifiable as most accurate — ranges from a pre-filtered population that are not transportable to unselected sore throat; the Spanish review (24 studies) pooled sensitivity 0.85 (0.84–0.87), specificity 0.96 (0.96–0.97), positive likelihood ratio 22.21 (15.12–32.63), negative LR 0.15 (0.13–0.18); no brand-level figure is printed — the class is the question

Stamped: 2026-11-28.

Evidence published: 2003–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children and patients with acute sore throat, how accurately do rapid antigen detection tests detect group A streptococcal pharyngitis against throat culture — in the Cochrane review in children, the 21-test health-technology assessment, and the Spanish systematic review?

Balance of the evidence

3 reports, all syntheses: Cohen 2016 (Cochrane, children, ambulatory care), Fraser 2020 (health-technology assessment of 21 point-of-care tests for acute sore throat, 26 accuracy reports against culture; its population of interest is pre-filtered by clinical score) and Ruiz-Aragón 2010 (Spanish-language journal, English abstract fetched and verified; 24 studies, 2000–2009). The HTA also covers molecular point-of-care tests as a different test class; its record prints no separate molecular accuracy pair, so none is carded separately — the printed range is the score-filtered point-of-care range as published. No report was refused. Cross-point in prose only: the Centor score is homed at pack #7809 — a clinical-score question; the score and the swab test are different index tests.

MeSH: Adolescent · Antigens, Bacterial/analysis* · Child · Humans · Immunoenzyme Techniques/standards*,statistics & numerical data · Pharyngitis/microbiology* · Reference Standards · Sensitivity and Specificity · Streptococcal Infections/diagnosis* · Streptococcus pyogenes/immunology* · Cost-Benefit Analysis* · Immunologic Tests* · Pharyngitis/drug therapy* · Point-of-Care Testing/economics* · Streptococcal Infections/drug therapy* · Bacteriological Techniques · Streptococcus pyogenes/immunology*,isolation & purification* · Time Factors

Cards (4)

Card 1 — Cochrane review in children (Cohen 2016, Cochrane Database of Systematic Reviews — 98 studies / 101,121 participants; main analysis 105 test evaluations / 58,244 children, median GAS prevalence 29.5%): summary sensitivity 85.6% (95% CI 83.3–87.6), specificity 95.4% (94.5–96.2); enzyme vs optical immunoassay sensitivity 85.4% vs 86.2%

Study: Cochrane systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: Children with pharyngitis seen in ambulatory care, in studies comparing a rapid antigen detection test with throat culture on blood agar plate; 98 unique studies (116 test evaluations; 101,121 participants), with the main analysis restricted to the 105 evaluations (58,244 participants) in which all participants underwent both tests.

Summary: Cochrane review in children (Cohen 2016, Cochrane Database of Systematic Reviews — 98 studies / 101,121 participants; main analysis 105 test evaluations / 58,244 children, median GAS prevalence 29.5%): summary sensitivity 85.6% (95% CI 83.3–87.6), specificity 95.4% (94.5–96.2); enzyme vs optical immunoassay sensitivity 85.4% vs 86.2%

Result: The rapid antigen test had a summary sensitivity of 85.6% (95% CI 83.3 to 87.6) and summary specificity of 95.4% (94.5 to 96.2). The sensitivity of enzyme immunoassay and optical immunoassay tests was comparable (summary sensitivity 85.4% versus 86.2%). In a population of 1,000 children at 30% GAS prevalence, 43 patients with GAS will be missed; among 100 children with strep throat, 86 would be correctly detected and 14 missed and not receive antibiotic treatment, as published.

Watch out: Overall methodological quality was poor — high risk of bias in 73% of evaluations for patient selection and 43% for the reference standard — and sensitivity was substantially heterogeneous across studies even though the summary estimates were stable in low-risk-of-bias sensitivity analyses.

Source: Cohen et al. Rapid antigen detection test for group A streptococcus in children with pharyngitis. The Cochrane database of systematic reviews. 2016. PMID: 27374000. Registry ID: none in the record. MeSH: Adolescent · Antigens, Bacterial/analysis* · Child · Humans · Immunoenzyme Techniques/standards*,statistics & numerical data · Pharyngitis/microbiology* · Reference Standards · Sensitivity and Specificity · Streptococcal Infections/diagnosis* · Streptococcus pyogenes/immunology*

Card 2 — Health-technology assessment (Fraser 2020, Health Technology Assessment — systematic reviews of 21 point-of-care tests for group A streptococcus in acute sore throat; 26 accuracy reports against culture): in the score-filtered population of interest, point estimates ranged 0.829–0.946 sensitivity and 0.849–0.991 specificity; no test identifiable as most accurate

Study: Health-technology assessment — systematic reviews and economic evaluation (synthesis, counted as a synthesis)

Population: People aged ≥5 years presenting with sore throat symptoms, in 26 full-text articles and abstracts reporting accuracy of point-of-care tests and/or clinical scores against biological culture; the population of interest was patients with Centor/McIsaac scores ≥3 or FeverPAIN scores ≥4. The assessment was registered on PROSPERO (CRD42018118653, printed in the abstract).

Summary: Health-technology assessment (Fraser 2020, Health Technology Assessment — systematic reviews of 21 point-of-care tests for group A streptococcus in acute sore throat; 26 accuracy reports against culture): in the score-filtered population of interest, point estimates ranged 0.829–0.946 sensitivity and 0.849–0.991 specificity; no test identifiable as most accurate

Result: In the population of interest, point estimates were 0.829 to 0.946 for sensitivity and 0.849 to 0.991 for specificity across tests. There was considerable heterogeneity, even for studies using the same point-of-care test, and it was not possible to identify which test is the most accurate. Fourteen of the 21 tests entered the economic modelling and were not cost-effective within current NICE thresholds, as published.

Watch out: These are ranges across 21 different tests in a clinically pre-filtered population — not a pooled pair, and not transportable to unselected sore throat; the record prints no separate accuracy pair for its molecular-test class, so none is carded.

Source: Fraser et al. Rapid antigen detection and molecular tests for group A streptococcal infections for acute sore throat: systematic reviews and economic evaluation. Health technology assessment (Winchester, England). 2020. PMID: 32605705. Registry ID: none in the record. MeSH: Cost-Benefit Analysis* · Humans · Immunologic Tests* · Pharyngitis/drug therapy* · Point-of-Care Testing/economics* · Streptococcal Infections/drug therapy*

Card 3 — Spanish systematic review (Ruiz-Aragón 2010, Anales de Pediatría — systematic review and meta-analysis, 24 studies 2000–2009; English abstract): overall sensitivity 0.85 (0.84–0.87), specificity 0.96 (0.96–0.97), positive likelihood ratio 22.21 (15.12–32.63), negative LR 0.15 (0.13–0.18)

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: Patients in 24 studies (2000–2009) of rapid antigen-detection tests for Streptococcus pyogenes from throat samples, quality measured with QUADAS criteria and rated moderate; individual-study sensitivity ranged 65.6%–96.4% and specificity 68.7%–99.3%.

Summary: Spanish systematic review (Ruiz-Aragón 2010, Anales de Pediatría — systematic review and meta-analysis, 24 studies 2000–2009; English abstract): overall sensitivity 0.85 (0.84–0.87), specificity 0.96 (0.96–0.97), positive likelihood ratio 22.21 (15.12–32.63), negative LR 0.15 (0.13–0.18)

Result: The meta-analysis determined an overall sensitivity of 0.85 (95% CI 0.84–0.87), specificity 0.96 (0.96–0.97), likelihood ratio (+) 22.21 (15.12–32.63) and likelihood ratio (−) 0.15 (0.13–0.18); positive predictive value ranged 59.4%–97.4% and negative predictive value 87.8%–98% across studies. The authors conclude the tests have good diagnostic performance but must be complemented with microbiological culture because false positives and negatives occur, as published.

Watch out: The individual-study ranges (sensitivity as low as 65.6%, specificity as low as 68.7%) are far wider than the pooled pair suggests — the pool averages over devices and settings that perform very differently.

Source: Ruiz-Aragón et al. [Evaluation of rapid methods for detecting Streptococcus pyogenes. Systematic review and meta-analysis]. Anales de pediatria (Barcelona, Spain : 2003). 2010. PMID: 20346743. Registry ID: none in the record. MeSH: Antigens, Bacterial/analysis* · Bacteriological Techniques · Humans · Pharyngitis/microbiology* · Streptococcus pyogenes/immunology*,isolation & purification* · Time Factors

Card 4 — Synthesis: rapid antigen tests for group A streptococcus are specific (~0.95–0.96) but miss roughly 1 in 7 true cases (sensitivity ~0.85–0.86) in both pooled syntheses, and the 21-test assessment could not rank the devices — 3 syntheses pooling many commercial devices as one class

Study: Synthesis

Population: Pools as carded: 98 studies / 101,121 participants, children in ambulatory care (Cochrane); 21 tests / 26 accuracy reports, score-filtered population of interest (HTA); 24 studies, 2000–2009 (Spanish review). No brand-level figure exists in any anchor and none is printed.

Summary: Synthesis: rapid antigen tests for group A streptococcus are specific (~0.95–0.96) but miss roughly 1 in 7 true cases (sensitivity ~0.85–0.86) in both pooled syntheses, and the 21-test assessment could not rank the devices — 3 syntheses pooling many commercial devices as one class

Result: Pooled pairs: 85.6% / 95.4% (Cochrane, children); 0.85 / 0.96 with LR+ 22.21 and LR− 0.15 (Spanish). HTA ranges in the filtered population: sensitivity 0.829–0.946, specificity 0.849–0.991, no most-accurate test. Sensitivity is the weak direction in every synthesis. No report was refused. Cross-point in prose only: Centor score at pack #7809. The stamp is PREDICTIVE PERFORMANCE with the class-pooling and the missed-cases figure on its face.

Watch out: Do not use a negative rapid antigen result alone to exclude strep throat where the consequence of a miss matters — the Cochrane authors' own worked example misses 14 of 100 true cases — and do not attribute the class figures to any single commercial device.

Source: Synthesis of the reports carded above; no additional source.