SourceMed · Shelf #8449 in the ask interface

Point-of-care ultrasound for abscess vs cellulitis — sensitivity 94.6% / specificity 85.4% in 14 prospective studies (2,656 patients), 0.93 / 0.87 in a second overlapping synthesis, and 0.90 / 0.80 in children against physical examination at 0.84 / 0.69; adults outperform children in all three, and the clinically unclear subgroup is the weakest spectrum

Shelf #8449 · Emergency & first hours

PREDICTIVE PERFORMANCE — accurate, with a consistent adult–child gradient: ultrasonography pooled at sensitivity 94.6% (95% CI 89.4–97.4) / specificity 85.4% (78.9–90.2), positive likelihood ratio 6.5, negative LR 0.06 in 14 prospective studies (2,656 patients), with a correct management change in 10.3% of cases and an incorrect change in 0.7%; a second overlapping synthesis pooled 0.93 (0.92–0.94) / 0.87 (0.85–0.89), summary ROC area 0.95; and in children (7 studies / 870 patients) 0.90 (0.82–0.95) / 0.80 (0.72–0.86) against physical examination at 0.84 / 0.69. Adult performance (0.98–0.99 sensitivity) exceeds paediatric (0.90) in every synthesis — a gradient, not a single pair. All three syntheses overlap in primary studies. The reference standard is partly the drainage result the test itself prompts (incorporation risk), and the clinically unclear subgroup — where the test is actually needed — is its weakest spectrum (91.9% / 76.9%, LR− 0.11)

Stamped: 2026-11-28.

Evidence published: 2020–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In emergency-department patients with skin and soft-tissue infection, how accurately does point-of-care ultrasonography distinguish abscess from cellulitis against drainage, aspiration or clinical course — in adults, in children, and against physical examination?

Balance of the evidence

3 reports, all syntheses counted as syntheses, overlapping in primary studies and printed as overlapping syntheses. Cross-points in prose only: the other point-of-care-ultrasound accuracy packs from slate 36 (different anatomical questions) are not this question.

MeSH: Abscess · Cellulitis · Clinical Trials as Topic · Diagnosis, Differential · Humans · Physical Examination · Point-of-Care Systems* · Soft Tissue Infections/classification,diagnostic imaging* · Ultrasonography* · Abscess/diagnostic imaging · Child · Emergency Service, Hospital · Point-of-Care Systems · Sensitivity and Specificity · Soft Tissue Infections*/diagnostic imaging · Ultrasonography/methods

Cards (4)

Card 1 — Soft-tissue POCUS synthesis (Gottlieb 2020, Annals of Emergency Medicine — systematic review and meta-analysis, 14 prospective studies / 2,656 patients): sensitivity 94.6% (95% CI 89.4–97.4) / specificity 85.4% (78.9–90.2), LR+ 6.5, LR− 0.06; correct management change 10.3%, incorrect 0.7%

Study: Systematic review and meta-analysis (synthesis)

Population: 2,656 ED patients with skin and soft-tissue infection in 14 prospective studies of point-of-care ultrasonography for abscess, with adult, paediatric, high-suspicion and clinically unclear subgroups.

Summary: Soft-tissue POCUS synthesis (Gottlieb 2020, Annals of Emergency Medicine — systematic review and meta-analysis, 14 prospective studies / 2,656 patients): sensitivity 94.6% (95% CI 89.4–97.4) / specificity 85.4% (78.9–90.2), LR+ 6.5, LR− 0.06; correct management change 10.3%, incorrect 0.7%

Result: Overall: sensitivity 94.6% (95% CI 89.4–97.4%), specificity 85.4% (78.9–90.2%), positive likelihood ratio 6.5 (4.4–9.6), negative LR 0.06 (0.03–0.13), likelihood ratios labelled as such. Clinically unclear cases: 91.9% / 76.9% (LR− 0.11). Adults: 98.7% / 91.0% (LR− 0.01); children: 89.9% / 79.9% (LR− 0.13). Ultrasonography led to a correct change in management in 10.3% of cases and an incorrect change in 0.7%, as published.

Watch out: The reference standard is partly the drainage result the test itself prompts (incorporation risk in the primaries), which flatters accuracy — and the clinically unclear subgroup, the real use case, is the weakest spectrum.

Source: Gottlieb M et al. Point-of-Care Ultrasonography for the Diagnosis of Skin and Soft Tissue Abscesses: A Systematic Review and Meta-analysis.. Annals of emergency medicine. 2020. PMID: 32081383. Registry ID: none in the record. MeSH: Abscess · Cellulitis · Clinical Trials as Topic · Diagnosis, Differential · Humans · Physical Examination · Point-of-Care Systems* · Soft Tissue Infections/classification,diagnostic imaging* · Ultrasonography*

Card 2 — Soft-tissue POCUS synthesis 2 (Rahmani 2023, Archives of Academic Emergency Medicine — TYPE-FLAG: typed Review only at PubMed although a QUADAS-2-assessed meta-analysis on substance, counted on substance; pool overlaps the 2020 synthesis): pooled sensitivity 0.93 (95% CI 0.92–0.94) / specificity 0.87 (0.85–0.89), summary ROC area 0.95; adults 0.98 / 0.92 vs children 0.90 / 0.78

Study: Systematic review and meta-analysis (synthesis; TYPE-FLAG — typed Review only)

Population: Adult and paediatric ED patients with skin and soft-tissue infection in studies of point-of-care ultrasonography for abscess identification, searched to January 2023 (the abstract does not state a pooled patient total).

Summary: Soft-tissue POCUS synthesis 2 (Rahmani 2023, Archives of Academic Emergency Medicine — TYPE-FLAG: typed Review only at PubMed although a QUADAS-2-assessed meta-analysis on substance, counted on substance; pool overlaps the 2020 synthesis): pooled sensitivity 0.93 (95% CI 0.92–0.94) / specificity 0.87 (0.85–0.89), summary ROC area 0.95; adults 0.98 / 0.92 vs children 0.90 / 0.78

Result: Pooled sensitivity 0.93 (95% CI 0.92–0.94), specificity 0.87 (0.85–0.89) and summary ROC area 0.95. In adults: 0.98 (0.92–1.00) / 0.92 (0.86–0.95), area 0.99. In children: 0.90 (0.87–0.92) / 0.78 (0.73–0.82), area 0.91, as published.

Watch out: Its pool overlaps the 2020 synthesis's pool — agreement between the two is agreement of overlapping syntheses, not independent confirmation.

Source: Rahmani E et al. Point-Of-Care Ultrasonography for Identification of Skin and Soft Tissue Abscess in Adult and Pediatric Patients; a Systematic Review and Meta-Analysis.. Archives of academic emergency medicine. 2023. PMID: 37609534. Registry ID: none in the record. MeSH: none in the record

Card 3 — Paediatric POCUS synthesis (Wu 2022, Medical Ultrasonography — systematic review and meta-analysis in children, 7 studies / 870 patients): ultrasonography 0.90 (95% CI 0.82–0.95) / 0.80 (0.72–0.86), LR+ 4.5, LR− 0.13, against physical examination 0.84 / 0.69 in the 4 studies reporting it — with significant heterogeneity

Study: Systematic review and meta-analysis (synthesis)

Population: 870 paediatric ED patients with skin and soft-tissue infections in 7 studies of point-of-care ultrasound for abscess; 4 studies also reported physical examination.

Summary: Paediatric POCUS synthesis (Wu 2022, Medical Ultrasonography — systematic review and meta-analysis in children, 7 studies / 870 patients): ultrasonography 0.90 (95% CI 0.82–0.95) / 0.80 (0.72–0.86), LR+ 4.5, LR− 0.13, against physical examination 0.84 / 0.69 in the 4 studies reporting it — with significant heterogeneity

Result: Ultrasonography: pooled sensitivity 0.90 (95% CI 0.82–0.95), specificity 0.80 (0.72–0.86), positive likelihood ratio 4.5 (3.1–6.4), negative LR 0.13 (0.07–0.23), area under the curve 0.89 (0.86–0.91), likelihood ratios labelled as such. Physical examination: 0.84 (0.80–0.88) / 0.69 (0.62–0.76), area 0.85. There was significant heterogeneity across studies, as published.

Watch out: The paediatric limb is the family's weakest in every synthesis — do not quote the all-ages or adult pairs for a child.

Source: Wu J et al. Role of point-of-care ultrasound (POCUS) in the diagnosis of an abscess in paediatric skin and soft tissue infections: a systematic review and meta-analysis.. Medical ultrasonography. 2022. PMID: 34379709. Registry ID: none in the record. MeSH: Abscess/diagnostic imaging · Cellulitis · Child · Emergency Service, Hospital · Humans · Point-of-Care Systems · Sensitivity and Specificity · Soft Tissue Infections*/diagnostic imaging · Ultrasonography/methods

Card 4 — Synthesis: one test, three overlapping pools, one consistent gradient — 14 prospective studies / 2,656 patients; a second all-ages synthesis; 7 paediatric studies / 870 patients

Study: Synthesis

Population: 3 reports, all syntheses with overlapping primary studies; no primary report is carded on this row.

Summary: Synthesis: one test, three overlapping pools, one consistent gradient — 14 prospective studies / 2,656 patients; a second all-ages synthesis; 7 paediatric studies / 870 patients

Result: Point-of-care ultrasonography distinguishes abscess from cellulitis accurately (sensitivity ~0.93–0.95, specificity ~0.85–0.87 overall), outperforms physical examination in children, and changes management correctly ten times as often as incorrectly — with adults consistently outperforming children and the clinically unclear spectrum weakest. The stamp is PREDICTIVE PERFORMANCE with the gradient and incorporation caveat on the face.

Watch out: Do not pool the three syntheses into one pair, and remember the reference standard partly incorporates the test's own consequence (drainage).

Source: Synthesis of the reports carded above; no additional source.