SourceMed · Shelf #8450 in the ask interface
RQLQ family measurement properties — standardized version concordant with the original (overall ICC 0.996; reliability 0.97 both), MiniRQLQ reliability 0.93 with better responsiveness, Paediatric RQLQ reliability 0.93; Spanish version reliable (alpha 0.85–0.96) but 85.6% of patients needed assistance to complete it
Shelf #8450 · Eyes, skin, nose & allergy
MEASUREMENT PROPERTIES — strong programme measurement properties, with a self-administration feasibility warning: the RQLQ(S) measured the same construct as the original (overall scores 2.36 ± 1.23 vs 2.43 ± 1.23; overall concordance ICC 0.996; reliability in stable patients ICC 0.97 for both; responsiveness good for both), although its activity domain scored consistently lower (P <.001). The MiniRQLQ traded a little reliability (ICC 0.93 vs 0.97) for better responsiveness (P = 0.044), with concordance ICC 0.87. The Paediatric RQLQ (23 items) showed reliability ICC 0.93, responsiveness p < 0.001 and discrimination of stable from changed patients (p = 0.005). The Spanish version was reliable in regular practice (domain alpha 0.85–0.96, ICC 0.68–0.89, effect sizes 0.76–1.46) but 85.6% of patients needed assistance to complete it. The Greek versions' abstract prints no coefficient, and none is printed for it. Composition: 3 Juniper-programme reports + 2 independent language validations
Stamped: 2026-11-28.
Evidence published: 1998–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the RQLQ family (the Rhinoconjunctivitis Quality of Life Questionnaire — 28 items in seven domains including three patient-selected activity items, each scored 0–6 — its standardized version RQLQ(S), its 14-item MiniRQLQ, and the 23-item Paediatric RQLQ) — what did the standardized-version validation find against the original, what did the MiniRQLQ development find, what did the paediatric development find, and what did the Spanish and Greek versions find?
Balance of the evidence
5 reports: 3 programme reports from the Juniper group (standardized version, MiniRQLQ, Paediatric RQLQ — the first two sharing the same 5-week, 100-adult observational design) + 2 independent language validations (Spanish, 284 adults at 37 centres; Greek, 98 patients). The shared design prints. Distinct from SNOT-22 (sinonasal outcome in chronic rhinosinusitis): the RQLQ family measures allergic rhinoconjunctivitis quality of life — cross-point in prose only.
MeSH: Activities of Daily Living · Adolescent · Adult · Aged · Conjunctivitis/psychology* · Evaluation Studies as Topic · Female · Humans · Male · Middle Aged · Quality of Life* · Reproducibility of Results · Rhinitis/psychology* · Rhinitis, Allergic, Perennial/psychology · Rhinitis, Allergic, Seasonal/psychology · Surveys and Questionnaires/standards · Conjunctivitis/physiopathology*,psychology* · Cross-Sectional Studies · Longitudinal Studies · Rhinitis/physiopathology*,psychology* · Surveys and Questionnaires* · Child · Conjunctivitis, Allergic* · Quality of Life · Rhinitis, Allergic, Seasonal* · Prospective Studies · Sickness Impact Profile* · Socioeconomic Factors · Spain · Surveys and Questionnaires · Translations · Rhinitis, Allergic*/diagnosis
Cards (6)
Card 1 — Standardized-version validation (Juniper 1999, Journal of Allergy and Clinical Immunology — programme report; 5-week observational study, 100 adults): RQLQ(S) overall 2.36 ± 1.23 vs RQLQ 2.43 ± 1.23, concordance ICC 0.996, reliability ICC 0.97 for both — activity domain scored consistently lower (P <.001)
Study: Validation study (primary report; programme — Juniper group)
Population: 100 adults with symptomatic rhinoconjunctivitis completing the RQLQ(S), the RQLQ and other health-status measures at baseline, 1 and 5 weeks; the standardized activities were derived from 5 RQLQ databases.
Summary: Standardized-version validation (Juniper 1999, Journal of Allergy and Clinical Immunology — programme report; 5-week observational study, 100 adults): RQLQ(S) overall 2.36 ± 1.23 vs RQLQ 2.43 ± 1.23, concordance ICC 0.996, reliability ICC 0.97 for both — activity domain scored consistently lower (P <.001)
Result: The RQLQ(S) activity domain consistently gave lower scores than the RQLQ's (P <.001), but overall scores differed minimally (RQLQ(S) 2.36 ± 1.23 vs RQLQ 2.43 ± 1.23) with overall concordance ICC = 0.996. In stable patients, reliability was high and almost identical for both instruments (ICC = 0.97). Responsiveness to change was very similar and good (P <.001) and construct validity was strong for both, as published.
Watch out: A programme validation in the developers' own design — the near-perfect concordance (0.996) is between two versions completed by the same patients, not independent replication.
Source: Juniper EF et al. Validation of the standardized version of the Rhinoconjunctivitis Quality of Life Questionnaire.. The Journal of allergy and clinical immunology. 1999. PMID: 10452758. Registry ID: none in the record. MeSH: Activities of Daily Living · Adolescent · Adult · Aged · Conjunctivitis/psychology* · Evaluation Studies as Topic · Female · Humans · Male · Middle Aged · Quality of Life* · Reproducibility of Results · Rhinitis/psychology* · Rhinitis, Allergic, Perennial/psychology · Rhinitis, Allergic, Seasonal/psychology · Surveys and Questionnaires/standards
Card 2 — MiniRQLQ development (Juniper 2000, Clinical and Experimental Allergy — programme report; TYPE-FLAG: typed Clinical Trial at PubMed for an observational questionnaire study, counted on substance; same 5-week, 100-adult design): reliability ICC 0.93 vs RQLQ 0.97, responsiveness BETTER than the RQLQ (P = 0.044), concordance ICC 0.87
Study: Development and validation study (primary report; programme — Juniper group; TYPE-FLAG — typed Clinical Trial)
Population: 100 adults with symptomatic rhinoconjunctivitis completing the 14-item self-administered MiniRQLQ (five domains), the RQLQ and other measures at baseline, 1 and 5 weeks.
Summary: MiniRQLQ development (Juniper 2000, Clinical and Experimental Allergy — programme report; TYPE-FLAG: typed Clinical Trial at PubMed for an observational questionnaire study, counted on substance; same 5-week, 100-adult design): reliability ICC 0.93 vs RQLQ 0.97, responsiveness BETTER than the RQLQ (P = 0.044), concordance ICC 0.87
Result: In stable patients, reliability was very acceptable for the MiniRQLQ (ICC = 0.93) but not quite as good as for the RQLQ (ICC = 0.97). Responsiveness to change was better with the MiniRQLQ than the RQLQ (P = 0.044). Construct validity was strong for both and concordance between the instruments was high (ICC = 0.87), as published.
Watch out: Same 100-adult design as the standardized-version card — the two programme reports are not independent samples.
Source: Juniper EF et al. Development and validation of the mini Rhinoconjunctivitis Quality of Life Questionnaire.. Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology. 2000. PMID: 10606940. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Conjunctivitis/physiopathology*,psychology* · Cross-Sectional Studies · Female · Humans · Longitudinal Studies · Male · Middle Aged · Quality of Life* · Reproducibility of Results · Rhinitis/physiopathology*,psychology* · Surveys and Questionnaires*
Card 3 — Paediatric RQLQ development (Juniper 1998, Journal of Allergy and Clinical Immunology — programme report): 34 children generated the item pool; validation in 75 children — reliability ICC 0.93, responsiveness p < 0.001, differentiated stable from changed patients (p = 0.005)
Study: Development and validation study (primary report; programme — Juniper group)
Population: 34 children with seasonal allergic rhinoconjunctivitis in the development study (item pool from summer camps, media notices and an allergy clinic); 75 children with symptomatic seasonal allergic rhinoconjunctivitis in the validation study, assessed at 0, 1 and 3 weeks. The Paediatric RQLQ has 23 items in five domains on a seven-point scale.
Summary: Paediatric RQLQ development (Juniper 1998, Journal of Allergy and Clinical Immunology — programme report): 34 children generated the item pool; validation in 75 children — reliability ICC 0.93, responsiveness p < 0.001, differentiated stable from changed patients (p = 0.005)
Result: In stable patients the Paediatric RQLQ demonstrated good reliability (ICC = 0.93). The questionnaire was very responsive to change (p < 0.001) and differentiated patients in a stable clinical state from those whose state changed (p = 0.005). Correlations with diary scores were close to predicted, supporting cross-sectional and longitudinal validity, as published.
Watch out: Seasonal allergic rhinoconjunctivitis only — the validation does not cover perennial disease or other ages beyond the studied children.
Source: Juniper EF et al. Measuring quality of life in children with rhinoconjunctivitis.. The Journal of allergy and clinical immunology. 1998. PMID: 9500748. Registry ID: none in the record. MeSH: Child · Conjunctivitis, Allergic* · Female · Humans · Male · Quality of Life · Reproducibility of Results · Rhinitis, Allergic, Seasonal* · Surveys and Questionnaires*
Card 4 — Spanish version in regular practice (Soler 2004, Revista Clínica Española — 284 adults at 37 Spanish centres): domain Cronbach alpha 0.85–0.96, ICC 0.68–0.89, effect sizes for change 0.76–1.46 — but mean completion 9.67 (SD 6.25) minutes with 85.6% of patients needing assistance to complete it
Study: Validation study (primary report; independent language validation)
Population: 284 adult patients with rhinoconjunctivitis (seasonal or perennial) at 37 Spanish allergy or ENT centres, in clinically non-stable (treated) and stable groups, assessed at baseline and 15 days with the RQLQ and EQ-5D.
Summary: Spanish version in regular practice (Soler 2004, Revista Clínica Española — 284 adults at 37 Spanish centres): domain Cronbach alpha 0.85–0.96, ICC 0.68–0.89, effect sizes for change 0.76–1.46 — but mean completion 9.67 (SD 6.25) minutes with 85.6% of patients needing assistance to complete it
Result: Mean administration time was 9.67 (SD 6.25) minutes and 85.6% of patients needed assistance to complete the RQLQ, especially selecting the patient-specific activities (62.5%). Domain Cronbach alpha ranged 0.85–0.96 and ICC 0.68–0.89; sensitivity to change (effect size between visits) ranged 0.76–1.46. The authors concluded the Spanish version is valid for assessing health-related quality of life in regular practice, as published.
Watch out: The 85.6% assistance rate is a feasibility warning for self-administration — the patient-selected activity items are the main difficulty, which is precisely what the standardized version was built to remove.
Source: Soler R et al. [Validation of the Spanish version of the Rhinoconjunctivitis Quality of Life Questionnaire (RQLQ)].. Revista clinica espanola. 2004. PMID: 15025979. Registry ID: none in the record. MeSH: Activities of Daily Living · Adolescent · Adult · Conjunctivitis/psychology* · Female · Humans · Male · Prospective Studies · Quality of Life* · Reproducibility of Results · Rhinitis/psychology* · Sickness Impact Profile* · Socioeconomic Factors · Spain · Surveys and Questionnaires · Translations
Card 5 — Greek versions (Katsimpris 2022, Journal of Laryngology and Otology — 98 patients with allergic rhinitis, adult and paediatric): internal consistency and test–retest reliability of both the RQLQ and MiniRQLQ high, with convergent and discriminative validity against SF-36, Beck Depression Inventory and Total 5 Symptoms Score — the abstract prints NO coefficient, and none is printed here
Study: Validation study (primary report; independent language validation; no coefficient printed)
Population: 98 patients with allergic rhinitis across adult and paediatric populations, assessed with the Greek RQLQ and MiniRQLQ, the SF-36, the Beck Depression Inventory and the Total 5 Symptoms Score, before and after treatment.
Summary: Greek versions (Katsimpris 2022, Journal of Laryngology and Otology — 98 patients with allergic rhinitis, adult and paediatric): internal consistency and test–retest reliability of both the RQLQ and MiniRQLQ high, with convergent and discriminative validity against SF-36, Beck Depression Inventory and Total 5 Symptoms Score — the abstract prints NO coefficient, and none is printed here
Result: Internal consistency and test–retest reliability of both questionnaires was high. Convergent validity showed statistically significant negative correlations of total RQLQ and MiniRQLQ scores with overall SF-36 score and positive correlations with the Beck Depression Inventory and Total 5 Symptoms Score. Discriminative validity showed significant improvement for all instruments and domains after treatment; females had higher scores and age was positively correlated with total scores, as published.
Watch out: Qualitative support only — with no coefficient in the abstract, this card can corroborate the family's transportability but cannot carry a number.
Source: Katsimpris P et al. The Rhinoconjunctivitis Quality of Life Questionnaire and its modified short version validation in adults and children with allergic rhinitis.. The Journal of laryngology and otology. 2022. PMID: 34847975. Registry ID: none in the record. MeSH: Adolescent · Adult · Child · Female · Humans · Male · Quality of Life · Reproducibility of Results · Rhinitis, Allergic*/diagnosis · Rhinitis, Allergic, Seasonal* · Surveys and Questionnaires
Card 6 — Synthesis: a coherent family with one feasibility warning — 3 programme reports (two sharing one 100-adult design) + 2 independent language validations (284 + 98 patients)
Study: Synthesis
Population: 5 reports. No report was refused on this row; the Greek card is coefficient-free by its own abstract and prints as such.
Summary: Synthesis: a coherent family with one feasibility warning — 3 programme reports (two sharing one 100-adult design) + 2 independent language validations (284 + 98 patients)
Result: Standardization and shortening cost the RQLQ family little: concordance 0.996 for the RQLQ(S), reliability 0.93–0.97 across forms, and responsiveness preserved or improved in the Mini. The Spanish feasibility limb (85.6% needing assistance) is the family's practical caveat. The stamp is MEASUREMENT PROPERTIES with the composition on the face.
Watch out: Programme reports dominate this family — independent replication is two language validations, one of them coefficient-free — so the figures describe the developers' instruments as validated, not as independently re-derived.
Source: Synthesis of the reports carded above; no additional source.