Asthma Control Test measurement properties — the ≤19 cut-point is population-dependent: 71% / 71% in 313 patients new to specialist care, 89% / 78% in 220 Turkish outpatients (AUC 0.91), 98% / 89% in 100 Greek outpatients, and ROC area 0.76 in 151 smoking asthmatics — never one pooled figure
Shelf #8451 · Lungs, breathing & sleep
MEASUREMENT PROPERTIES — reliable, valid and responsive, with a population-dependent cut-point: in patients new to specialist care (n = 313), internal consistency was 0.85 at baseline and 0.79 at follow-up, test–retest reliability 0.77, correlation with specialists' ratings r = 0.52 and with the ACQ r = −0.89, responsiveness against changes in specialist ratings (r = 0.44), ACQ (r = −0.69) and % predicted FEV1 (r = 0.29), and ≤19 gave sensitivity 71% and specificity 71% for uncontrolled asthma. The Turkish version (220 outpatients) found alpha 0.84, test–retest 0.85, AUC 0.91 with 89.06% / 78.26% at ≤19 and a minimally important difference of 3 points; the Greek version (100 outpatients) found alpha 0.72, test–retest 0.85 and 98.46% / 88.57% at ≤19 — materially more favourable, printed beside the derivation-population figures, never averaged; in smoking asthmatics (151 adults) alpha was 0.81, test–retest ICC 0.68 and ROC area for ≤19 was 0.76. Composition: 1 programme-linked longitudinal validation + 3 independent validations
Stamped: 2026-11-28.
Evidence published: 2006–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the ACT (Asthma Control Test — five patient-completed items on activity limitation, shortness of breath, night-time symptoms, rescue-medication use and self-rated control over the previous 4 weeks, scored 5–25, conventionally uncontrolled at ≤19) — what reliability, validity, responsiveness and cut-point did the longitudinal validation in patients new to specialist care find, and what did the Turkish, Greek and smoking-asthmatic validations find?
Balance of the evidence
4 reports: 1 programme-linked longitudinal validation (the Nathan group's validation in patients new to specialist care; the development report in routine specialist care is not carded here) + 3 independent validations (Turkish and Greek language versions; a spectrum extension to smoking asthmatics). Distinct from the ACQ question homed at slate 33 row S33-2-01 (the seven-item Juniper questionnaire including FEV1, scored 0–6): the ACT is the five-item patient-only test scored 5–25; the two instruments' correlation (r = −0.89) prints on the lead card as a comparator limb, and cross-points run both ways in prose.
MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Asthma/diagnosis,therapy* · Child · Humans · Longitudinal Studies · Mass Screening · Middle Aged · Reproducibility of Results · Respiratory Function Tests · Severity of Illness Index* · Surveys and Questionnaires* · Adrenal Cortex Hormones/administration & dosage · Asthma/diagnosis,psychology*,therapy · Female · Male · Prospective Studies · Quality of Life/psychology* · Sensitivity and Specificity · Severity of Illness Index · Sickness Impact Profile · Surveys and Questionnaires/standards* · Translating · Turkey · Asthma/diagnosis*,physiopathology · Forced Expiratory Volume · Greece · Young Adult · Asthma/diagnosis*,epidemiology · Cigarette Smoking/adverse effects* · Ethnicity · Spirometry · United States
Cards (5)
Card 1 — Longitudinal validation (Schatz 2006, Journal of Allergy and Clinical Immunology — programme-linked; 313 patients new to an asthma specialist, two visits 4–12 weeks apart): internal consistency 0.85 / 0.79, test–retest 0.77, r = −0.89 with the ACQ, and ≤19 at sensitivity 71% / specificity 71% for uncontrolled asthma
Study: Validation study (primary report; programme-linked longitudinal validation)
Population: 313 patients new to the care of an asthma specialist, completing the ACT and the Asthma Control Questionnaire at two visits 4–12 weeks apart, with spirometry and specialist control ratings.
Summary: Longitudinal validation (Schatz 2006, Journal of Allergy and Clinical Immunology — programme-linked; 313 patients new to an asthma specialist, two visits 4–12 weeks apart): internal consistency 0.85 / 0.79, test–retest 0.77, r = −0.89 with the ACQ, and ≤19 at sensitivity 71% / specificity 71% for uncontrolled asthma
Result: Internal consistency was 0.85 (baseline) and 0.79 (follow-up); test–retest reliability 0.77. Baseline ACT scores correlated with specialists' ratings (r = 0.52, P <.001) and ACQ scores (r = −0.89, P <.001). Changes in ACT scores correlated with changes in specialists' ratings (r = 0.44), ACQ (r = −0.69) and % predicted FEV1 (r = 0.29), all P <.001. An ACT score of 19 or less gave sensitivity 71% and specificity 71% for uncontrolled asthma, as published.
Watch out: The derivation-population cut-point performance (71% / 71%) is the family's most modest — later language validations report far better figures in different spectra, and the contrast is population, not progress.
Source: Schatz M et al. Asthma Control Test: reliability, validity, and responsiveness in patients not previously followed by asthma specialists.. The Journal of allergy and clinical immunology. 2006. PMID: 16522452. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Asthma/diagnosis,therapy* · Child · Humans · Longitudinal Studies · Mass Screening · Middle Aged · Reproducibility of Results · Respiratory Function Tests · Severity of Illness Index* · Surveys and Questionnaires*
Card 2 — Turkish version (Uysal 2013, Quality of Life Research — multicentre prospective study, 220 outpatients, visits at admission, 10 ± 2 days and 5 ± 1 weeks): Cronbach alpha 0.84, test–retest 0.85, AUC 0.91 with sensitivity 89.06% / specificity 78.26% at ≤19, minimally important difference 3 points
Study: Validation study (primary report; independent language validation)
Population: 220 asthma outpatients in Turkish clinics completing the Turkish ACT at three visits, with physician assessment of control at each visit.
Summary: Turkish version (Uysal 2013, Quality of Life Research — multicentre prospective study, 220 outpatients, visits at admission, 10 ± 2 days and 5 ± 1 weeks): Cronbach alpha 0.84, test–retest 0.85, AUC 0.91 with sensitivity 89.06% / specificity 78.26% at ≤19, minimally important difference 3 points
Result: Internal consistency was 0.84 (Cronbach alpha) and test–retest reliability 0.85 in stable patients. ACT scores correlated with physicians' assessments at admission (r = 0.68, p < 0.001). The AUC was 0.91, with sensitivity 89.06% and specificity 78.26% at a score of ≤19 for 'uncontrolled' asthma. A minimally important difference of three points was consistent with the GINA physician assessment between visits, as published.
Watch out: Outpatient spectrum with physician-assessed control as the comparator — its 89% sensitivity at ≤19 is not comparable head-to-head with the new-to-specialist 71%.
Source: Uysal MA et al. The validation of the Turkish version of Asthma Control Test.. Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation. 2013. PMID: 23143589. Registry ID: none in the record. MeSH: Adrenal Cortex Hormones/administration & dosage · Adult · Asthma/diagnosis,psychology*,therapy · Female · Humans · Male · Middle Aged · Prospective Studies · Quality of Life/psychology* · Reproducibility of Results · Sensitivity and Specificity · Severity of Illness Index · Sickness Impact Profile · Surveys and Questionnaires/standards* · Translating · Turkey
Card 3 — Greek version (Grammatopoulou 2011, Journal of Asthma — 100 outpatients under specialist care): one-factor solution (RMSEA <0.001), Cronbach alpha 0.72, 2-month test–retest 0.85, correlation with specialists' rating r = 0.89, and at ≤19 sensitivity 98.46% / specificity 88.57% for 'not controlled' asthma
Study: Validation study (primary report; independent language validation)
Population: 100 Greek asthma outpatients under a specialist's care, with construct, convergent and discriminant validity testing against specialists' ratings, FEV1% predicted and disability.
Summary: Greek version (Grammatopoulou 2011, Journal of Asthma — 100 outpatients under specialist care): one-factor solution (RMSEA <0.001), Cronbach alpha 0.72, 2-month test–retest 0.85, correlation with specialists' rating r = 0.89, and at ≤19 sensitivity 98.46% / specificity 88.57% for 'not controlled' asthma
Result: A one-factor solution fit (RMSEA <0.001). Internal consistency was Cronbach alpha 0.72 and 2-month test–retest reliability 0.85. The ACT score correlated with specialists' rating (r = 0.89, p < .001), FEV1% predicted (r = 0.57) and dyspnoea (r = −0.71). A score of 19 or less gave sensitivity 98.46% and specificity 88.57% for 'not controlled' asthma, as published.
Watch out: The most favourable cut-point figures on the row, from the smallest sample (n = 100) — printed beside the derivation figures, never averaged with them.
Source: Grammatopoulou EP et al. Validity and reliability evidence of the Asthma Control Test--ACT in Greece.. The Journal of asthma : official journal of the Association for the Care of Asthma. 2011. PMID: 21039187. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Asthma/diagnosis*,physiopathology · Female · Forced Expiratory Volume · Greece · Humans · Male · Middle Aged · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires* · Young Adult
Card 4 — Smoking-asthmatic validity (Soler 2018, Journal of Allergy and Clinical Immunology: In Practice — 151 adults who smoked, followed 6 weeks, physician global assessment as standard): Cronbach alpha 0.81 (95% CI 0.76–0.85), test–retest ICC 0.68 (0.57–0.78) in stable participants, ROC area 0.76 (0.67–0.84) for ≤19
Study: Validation study (primary report; independent spectrum extension)
Population: 151 adults with asthma who smoked (median 11 pack-years), classified by physician global assessment as well controlled (24%), not well controlled (42%) or very poorly controlled (34%) at enrolment; 93 with stable asthma contributed test–retest data.
Summary: Smoking-asthmatic validity (Soler 2018, Journal of Allergy and Clinical Immunology: In Practice — 151 adults who smoked, followed 6 weeks, physician global assessment as standard): Cronbach alpha 0.81 (95% CI 0.76–0.85), test–retest ICC 0.68 (0.57–0.78) in stable participants, ROC area 0.76 (0.67–0.84) for ≤19
Result: Cronbach alpha at enrolment was 0.81 (95% CI 0.76–0.85). The intraclass correlation for scores at enrolment and 6 weeks was 0.68 (0.57–0.78) in participants with stable asthma. ACT scores were associated with global assessment (P < .001). The area under the ROC curve for a cut-off of ≤19 (not well controlled) was 0.76 (0.67–0.84), and the score with maximum ROC area was 18.6, as published.
Watch out: Smokers are the spectrum where asthma control is hardest to judge clinically — the lower ROC area (0.76) and test–retest (0.68) describe this population, not a failure of the test elsewhere.
Source: Soler X et al. Validity of the Asthma Control Test Questionnaire Among Smoking Asthmatics.. The journal of allergy and clinical immunology. In practice. 2018. PMID: 28669892. Registry ID: none in the record. MeSH: Adult · Asthma/diagnosis*,epidemiology · Cigarette Smoking/adverse effects* · Ethnicity · Female · Humans · Male · Reproducibility of Results · Sensitivity and Specificity · Spirometry · Surveys and Questionnaires* · United States
Card 5 — Synthesis: one test, four populations, four cut-point performances — 1 programme-linked validation (313) + 3 independent validations (220 + 100 + 151)
Study: Synthesis
Population: 4 reports. No report was refused on this row; the development report in routine specialist care is not carded and is named in the balance only.
Summary: Synthesis: one test, four populations, four cut-point performances — 1 programme-linked validation (313) + 3 independent validations (220 + 100 + 151)
Result: The ACT is reliable (alpha 0.72–0.85), valid against specialist ratings and the ACQ, and responsive — but its ≤19 cut-point performs very differently by population (71% / 71% new to specialist care; 89% / 78% Turkish; 98% / 89% Greek; ROC area 0.76 in smokers). The stamp is MEASUREMENT PROPERTIES with the four estimates printed by population.
Watch out: Never quote a single sensitivity/specificity for the ACT cut-point — the honest figure is the range across spectra, anchored by the derivation population's modest 71% / 71%.
Source: Synthesis of the reports carded above; no additional source.