SourceMed · Shelf #8453 in the ask interface
CARAT / CARAT10 for combined rhinitis and asthma control — development by consensus (111 experts, 60 patients), reduction to 10 items (alpha 0.85, AUC 0.82), MCID 3.5 (whole-point 4), and a COSMIN synthesis (alpha 0.83; test–retest ICC 0.91 with I² = 93.7%)
Shelf #8453 · Eyes, skin, nose & allergy
MEASUREMENT PROPERTIES — good internal consistency, reliability, construct validity and responsiveness for combined rhinitis–asthma control: CARAT10 alpha 0.85 with AUC 0.82 against physician rating; test–retest ICC 0.82 and Guyatt responsiveness index 1.54 longitudinally; Dutch MCID 3.50 by Global Rating of Change (whole-point MCID 4 on the integer scale, SEM 2.83); the COSMIN synthesis (16 studies) pooled alpha 0.83 (95% CI 0.80–0.86) and ICC 0.91 (95% CI 0.64–0.98) with very high reliability heterogeneity (I² = 93.7%), which prints beside the pooled ICC wherever it is quoted; the development report claims face and content validity only and no psychometric figure is printed from it
Stamped: 2026-11-28.
Evidence published: 2009–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with allergic rhinitis and asthma, what are the measurement properties of CARAT (reduced to the 10-item CARAT10) — its development, factor structure, reliability, validity against physician ratings and the ACQ, responsiveness, and minimal clinically important difference?
Balance of the evidence
5 reports: 3 programme reports from the Fonseca group (consensus development; reduction to CARAT10 in 193 adults; longitudinal study in 62 adults, 51 completing both visits), 1 independent Dutch language / MCID study (92 patients), and 1 COSMIN systematic synthesis (16 studies, counted as a synthesis). The MCID prints as the pair 3.5 (anchor-based) / 4 (usable whole-point value), never as a single unqualified figure. Distinct from the ACT pack (asthma only) and the homed ACQ question (Slate 33 row S33-2-01): CARAT is the only instrument here scoring rhinitis and asthma control together; cross-points in prose only. The CARATkids paediatric variant is a different form and is not carded.
MeSH: Adult · Aged · Asthma/diagnosis*,therapy* · Feasibility Studies · Female · Humans · Male · Middle Aged · Portugal · Rhinitis, Allergic, Perennial/diagnosis*,therapy* · Rhinitis, Allergic, Seasonal/diagnosis*,therapy* · Surveys and Questionnaires* · Young Adult · Asthma/complications,diagnosis,physiopathology,therapy* · Cross-Sectional Studies · Rhinitis, Allergic, Perennial/complications,diagnosis,physiopathology,therapy* · Rhinitis, Allergic, Seasonal/complications,diagnosis,physiopathology,therapy* · Severity of Illness Index · Adolescent · Asthma/prevention & control* · Cross-Cultural Comparison · Primary Health Care · Reproducibility of Results · Rhinitis, Allergic/prevention & control* · Surveys and Questionnaires
Cards (6)
Card 1 — Development (Nogueira-Silva 2009, Respiratory Research — consensus development; 111 experts, 60 patients, 25 physicians at the final meeting, feasibility study in 31 patients): 34 candidate items reduced to 17 questions — face and content validity only, no psychometric figure
Study: Development report (programme report)
Population: 111 experts and 60 patients in a web-based consensus process, 25 primary- and secondary-care physicians at the final meeting, and 31 patients in a qualitative feasibility study.
Summary: Development (Nogueira-Silva 2009, Respiratory Research — consensus development; 111 experts, 60 patients, 25 physicians at the final meeting, feasibility study in 31 patients): 34 candidate items reduced to 17 questions — face and content validity only, no psychometric figure
Result: A literature review generated 34 potentially important items; the consensus process was completed in 2.5 months and formulated 17 questions; the feasibility study corrected wording and format problems and chose a semi-tabular format. The authors conclude the steps ensured design quality and face and content validity, and that psychometric validation studies had started, as published.
Watch out: A development report — it claims face and content validity only; no reliability, validity coefficient or cut-point may be printed from it.
Source: Nogueira-Silva L et al. Control of allergic rhinitis and asthma test--a formal approach to the development of a measuring tool. Respiratory research. 2009. PMID: 19534774. Registry ID: none in the record. MeSH: Adult · Aged · Asthma/diagnosis*,therapy* · Feasibility Studies · Female · Humans · Male · Middle Aged · Portugal · Rhinitis, Allergic, Perennial/diagnosis*,therapy* · Rhinitis, Allergic, Seasonal/diagnosis*,therapy* · Surveys and Questionnaires* · Young Adult
Card 2 — Reduction to CARAT10 (Fonseca 2010, Allergy — cross-sectional study, 193 adults with allergic rhinitis and asthma at 15 Portuguese clinics): 10 items, 2 factors, Cronbach alpha 0.85, correlations 0.58–0.79, AUC 0.82 against physician rating
Study: Validation study (programme report)
Population: 193 adults with allergic rhinitis and asthma from 15 outpatient clinics in Portugal.
Summary: Reduction to CARAT10 (Fonseca 2010, Allergy — cross-sectional study, 193 adults with allergic rhinitis and asthma at 15 Portuguese clinics): 10 items, 2 factors, Cronbach alpha 0.85, correlations 0.58–0.79, AUC 0.82 against physician rating
Result: The reduced CARAT10 has 10 questions and 2 factors; Cronbach alpha was 0.85; all correlation coefficients with the medical evaluation and other control measures met a priori predictions, ranging from 0.58 to 0.79; AUC was 0.82 against physician rating of control; mean CARAT10 scores were 24, 21 and 15 across the physician decision groups reduce / maintain / increase treatment, as published.
Watch out: Programme report from the derivation group in Portuguese clinics; the physician-rating reference and the ACQ / VAS comparators are limbs of this study, not independent validations.
Source: Fonseca JA et al. Validation of a questionnaire (CARAT10) to assess rhinitis and asthma in patients with asthma. Allergy. 2010. PMID: 20121755. Registry ID: none in the record. MeSH: Adult · Asthma/complications,diagnosis,physiopathology,therapy* · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Portugal · Rhinitis, Allergic, Perennial/complications,diagnosis,physiopathology,therapy* · Rhinitis, Allergic, Seasonal/complications,diagnosis,physiopathology,therapy* · Severity of Illness Index · Surveys and Questionnaires* · Young Adult
Card 3 — Longitudinal use (Fonseca 2012, Clinical and Translational Allergy — 62 adults, 51 completing both visits 4–6 weeks apart): test–retest ICC 0.82, Guyatt responsiveness index 1.54, change correlations 0.49–0.65 with ACQ5 / VAS and 0.31–0.41 with physician assessment
Study: Longitudinal validation study (programme-linked report)
Population: 62 adults with asthma and allergic rhinitis enrolled at 4 Portuguese central-hospital outpatient clinics; 51 completely filled out CARAT10 at both visits.
Summary: Longitudinal use (Fonseca 2012, Clinical and Translational Allergy — 62 adults, 51 completing both visits 4–6 weeks apart): test–retest ICC 0.82, Guyatt responsiveness index 1.54, change correlations 0.49–0.65 with ACQ5 / VAS and 0.31–0.41 with physician assessment
Result: Test–retest reliability (ICC) was 0.82; a significant change in CARAT10 score was seen in clinically unstable patients (p = 0.002) and the Guyatt responsiveness index was 1.54; correlations of score changes with ACQ5 and symptom-VAS changes ranged from 0.49 to 0.65, and with physician assessment changes from 0.31 to 0.41, as published.
Watch out: Programme-linked (the derivation group's own clinics) and small for a longitudinal claim — 51 completers; the record carries no MeSH in the record, printed as such in the source line.
Source: Fonseca JA et al. Control of Allergic Rhinitis and Asthma Test (CARAT) can be used to assess individual patients over time. Clinical and translational allergy. 2012. PMID: 22935298. Registry ID: none in the record. MeSH: none in the record
Card 4 — Dutch version and MCID (van der Leeuw 2015, NPJ Primary Care Respiratory Medicine — 92 patients, three measurements at 1-month intervals): MCID 3.50 by Global Rating of Change, SEM 2.83, whole-point MCID 4; alpha 0.82; ICC 0.81 and 0.80
Study: Cross-cultural validation study (primary report)
Population: 92 patients diagnosed with asthma and/or rhinitis, measured three times at 1-month intervals.
Summary: Dutch version and MCID (van der Leeuw 2015, NPJ Primary Care Respiratory Medicine — 92 patients, three measurements at 1-month intervals): MCID 3.50 by Global Rating of Change, SEM 2.83, whole-point MCID 4; alpha 0.82; ICC 0.81 and 0.80
Result: The MCID of CARAT was 3.50 based on Global Rating of Change scores; the standard error of measurement was 2.83; Cronbach alpha was 0.82; correlations with ACQ5 and VAS ranged from 0.64 to 0.76; test–retest ICC was 0.81 and 0.80; because CARAT uses a whole-point scale, the authors conclude the MCID is 4 points, as published.
Watch out: The MCID is method-dependent — 3.5 by anchor-based estimation and 4 as the usable whole-point value — and prints as that pair, never as one unqualified figure.
Source: van der Leeuw S et al. The minimal clinically important difference of the Control of Allergic Rhinitis and Asthma Test (CARAT): cross-cultural validation and relation with pollen counts. NPJ primary care respiratory medicine. 2015. PMID: 25569880. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Asthma/prevention & control* · Cross-Cultural Comparison · Female · Humans · Male · Middle Aged · Primary Health Care · Reproducibility of Results · Rhinitis, Allergic/prevention & control* · Surveys and Questionnaires · Young Adult
Card 5 — COSMIN synthesis (Vieira 2022, Clinical and Translational Allergy — systematic review and meta-analysis, 16 studies): pooled alpha 0.83 (95% CI 0.80–0.86, I² = 62.6%), pooled test–retest ICC 0.91 (95% CI 0.64–0.98, I² = 93.7%), minimal important difference 3.5
Study: Systematic review and meta-analysis (synthesis)
Population: 16 studies of the development, validation and cultural adaptation of CARAT, assessed under PRISMA and COSMIN guidelines.
Summary: COSMIN synthesis (Vieira 2022, Clinical and Translational Allergy — systematic review and meta-analysis, 16 studies): pooled alpha 0.83 (95% CI 0.80–0.86, I² = 62.6%), pooled test–retest ICC 0.91 (95% CI 0.64–0.98, I² = 93.7%), minimal important difference 3.5
Result: CARAT displayed sufficient content validity and very good consistency (meta-analytical Cronbach alpha 0.83; 95% CI 0.80–0.86; I² = 62.6%); the meta-analytical ICC was 0.91 (95% CI 0.64–0.98; I² = 93.7%); construct validity was good, especially against asthma patient-reported measures (absolute Spearman correlations 0.67–0.73, moderate quality of evidence); responsiveness was good; minimal important difference 3.5, as published.
Watch out: Counted as a synthesis, printed as such. The pooled ICC's heterogeneity is very high (I² = 93.7%) and its interval is wide (0.64–0.98) — it is not a transportable constant. The record carries no MeSH in the record.
Source: Vieira RJ et al. Control of Allergic Rhinitis and Asthma Test: A systematic review of measurement properties and COSMIN analysis. Clinical and translational allergy. 2022. PMID: 36178185. Registry ID: none in the record. MeSH: none in the record
Card 6 — Synthesis: a valid combined-airway control test whose MCID is a pair (3.5 / 4) and whose pooled reliability is heterogeneous — 3 programme reports + 1 independent Dutch study + 1 synthesis (16 studies)
Study: Synthesis
Population: 5 reports carded above. No report was refused on this row; the CARATkids paediatric variant is a different form and is not carded.
Summary: Synthesis: a valid combined-airway control test whose MCID is a pair (3.5 / 4) and whose pooled reliability is heterogeneous — 3 programme reports + 1 independent Dutch study + 1 synthesis (16 studies)
Result: Development established content validity only; CARAT10 (alpha 0.85, AUC 0.82) tracks physician ratings and changes over time (ICC 0.82, Guyatt 1.54); the Dutch study and the COSMIN synthesis agree on a minimal important difference of 3.5, usable as 4 whole points. The stamp is MEASUREMENT PROPERTIES at the level above, with the synthesis heterogeneity printed at weight.
Watch out: Do not pool the programme and synthesis figures into one reliability number, and do not quote the MCID as a single figure — the 3.5 / 4 pair is the finding.
Source: Synthesis of the reports carded above; no additional source.