SourceMed · Shelf #8467 in the ask interface
Sweat chloride reference values — age-banded medians rose from 13 mmol/L at 5–9 years to 23 mmol/L at 20+ years in 282 healthy subjects (Macroduct, ion-selective electrode), healthy babies' conductivity range reached the 60 mmol/L decision level, and 50 healthy volunteers averaged 15.7 mM by ICP-MS
Shelf #8467 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED — sweat chloride rises with age to about 19 years and healthy values sit below the conventional 60 mmol/L confirmatory threshold, with the measurand split printed on the face: by Macroduct collection with ion-selective electrodes, estimated median (95% reference interval) sweat chloride was 13 mmol/L (1–39) at 5–9 years, 18 (3–47) at 10–14, 20 (3–51) at 15–19 and 23 (5–56) at 20+ years (mmol/L is numerically identical to the US mEq/L for chloride); the three anchors measure three different things under one name — chloride itself, sodium-chloride conductivity, and chloride by ICP-MS — and are never merged into one 'normal sweat chloride'
Stamped: 2026-11-28.
Evidence published: 2002–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy people, what are the normal sweat chloride values — what age-banded reference intervals did 282 healthy subjects give on the Macroduct system, what 95% ranges did the biological-variation study calculate for healthy babies, and what distribution did 50 healthy volunteers give on an ICP-MS assay?
Balance of the evidence
3 reports, three different measurands: the age-banded chloride reference-interval derivation (282 healthy subjects + 40 pancreatic-insufficient CF patients, Macroduct / ion-selective electrode), a biological-variation study of sweat sodium-chloride conductivity (15 healthy volunteers, 20 healthy infants, 20 CF patients, weekly for 5 weeks) and an ICP-MS chloride assay study (50 healthy volunteers). The beta-adrenergic sweat test (PMID 36193559) is a different measurand (evaporimetry sweat rate) and is named in prose only, not carded. This row overturns Slate 36 Audit B4, which had found only method papers at search level. Electrolyte mmol/L values print as the records give them; for chloride, mmol/L and mEq/L are numerically identical.
MeSH: Adolescent · Adult · Aged · Aging/metabolism* · Child · Child, Preschool · Chlorides/metabolism* · Cohort Studies · Cystic Fibrosis/diagnosis*,genetics,metabolism* · Cystic Fibrosis Transmembrane Conductance Regulator/genetics*,isolation & purification · Female · Humans · Male · Middle Aged · Mutation · Reference Values · Sodium/metabolism* · Sweat/chemistry* · Young Adult · Case-Control Studies · Cystic Fibrosis/diagnosis,metabolism* · Electric Conductivity · Infant · Predictive Value of Tests · Reproducibility of Results · Sodium Chloride/metabolism* · Sweat/metabolism* · Chlorides/analysis* · Cystic Fibrosis/diagnosis* · Limit of Detection · Mass Spectrometry/methods*
Cards (4)
Card 1 — Age-banded reference intervals (Mishra 2008, J Pediatr — Macroduct, direct ion-selective electrodes): median sweat chloride 13 mmol/L at 5–9 years rising to 23 mmol/L at 20+ years
Study: Reference-interval derivation study (primary report)
Population: 282 healthy unrelated subjects aged 5 to >50 years, plus 40 pancreatic-insufficient cystic fibrosis patients; Wescor Macroduct collection.
Summary: Age-banded reference intervals (Mishra 2008, J Pediatr — Macroduct, direct ion-selective electrodes): median sweat chloride 13 mmol/L at 5–9 years rising to 23 mmol/L at 20+ years
Result: There was no overlap of sweat chloride between the CF and non-CF groups (sweat sodium did overlap). Sweat chloride increased with age, the rate of increase slowing progressively to zero after 19 years. Estimated median (95% reference interval): 13 mmol/L (1–39) at 5–9 years, 18 mmol/L (3–47) at 10–14, 20 mmol/L (3–51) at 15–19 and 23 mmol/L (5–56) at 20+ years.
Watch out: The derivation starts at age 5 — it gives no interval for the infants in whom sweat testing is most often done, and its upper limits (to 56 mmol/L in adults) approach the conventional diagnostic threshold, so an adult value in the 40s is inside this healthy interval, not automatically borderline disease.
Source: Mishra A et al. Diagnosis of cystic fibrosis by sweat testing: age-specific reference intervals. The Journal of pediatrics. 2008. PMID: 18589442. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aging/metabolism* · Child · Child, Preschool · Chlorides/metabolism* · Cohort Studies · Cystic Fibrosis/diagnosis*,genetics,metabolism* · Cystic Fibrosis Transmembrane Conductance Regulator/genetics*,isolation & purification · Female · Humans · Male · Middle Aged · Mutation · Reference Values · Sodium/metabolism* · Sweat/chemistry* · Young Adult
Card 2 — Biological variation of sweat conductivity (van der Merwe 2002, Ann Clin Biochem — weekly for 5 weeks): calculated 95% range 18–60 mmol/L in healthy babies
Study: Biological-variation study
Population: 15 healthy volunteers, 20 healthy infants and 20 known CF patients; sweat sodium-chloride conductivity measured weekly for 5 consecutive weeks.
Summary: Biological variation of sweat conductivity (van der Merwe 2002, Ann Clin Biochem — weekly for 5 weeks): calculated 95% range 18–60 mmol/L in healthy babies
Result: Within-subject biological variation was 12.0% and between-subject 30.0% in healthy controls (18% and 20% in healthy infants; 7.3% and 6.5% in CF patients). Calculated 95% ranges were 18–60 mmol/L for healthy babies and 96–144 mmol/L for CF patients, supporting a decision level of >60 mmol/L for confirmatory testing. (The record prints the unit as 'mmoL/L' in places — a typography defect in the record, noted here and never reproduced as a figure; values print as mmol/L.)
Watch out: This anchor measures conductivity — a sodium-chloride screening equivalent, not chloride itself — and must never be merged with the chloride intervals. Its healthy-baby range reaches exactly the 60 mmol/L decision level, so conductivity screening in babies will flag some healthy infants for confirmatory testing. This PMID was named at search level in Slate 36's Audit B and is carded here for the first time.
Source: van der Merwe DE et al. Biological variation in sweat sodium chloride conductivity. Annals of clinical biochemistry. 2002. PMID: 11858217. Registry ID: none in the record. MeSH: Adolescent · Adult · Case-Control Studies · Child · Child, Preschool · Cystic Fibrosis/diagnosis,metabolism* · Electric Conductivity · Female · Humans · Infant · Male · Middle Aged · Predictive Value of Tests · Reproducibility of Results · Sodium Chloride/metabolism* · Sweat/metabolism*
Card 3 — ICP-MS sweat chloride (Marvelli 2020, Anal Bioanal Chem — candidate reference method): mean 15.7 mM in 50 healthy volunteers, range 2.8–37.4 mM
Study: Assay / reference-method study with a healthy-volunteer distribution
Population: 50 healthy volunteers; cross-validation against coulometric titration on 50 samples spanning 10–131 mM, plus two patients with suspected cystic fibrosis (65.6 mM and 81.2 mM).
Summary: ICP-MS sweat chloride (Marvelli 2020, Anal Bioanal Chem — candidate reference method): mean 15.7 mM in 50 healthy volunteers, range 2.8–37.4 mM
Result: Healthy volunteers showed a mean chloride concentration of 15.7 mM (25th–75th percentile 10.1–19.3 mM, range 2.8–37.4 mM). The ICP-MS method was linear with precision RSD <6% and accuracy 99.7–103.8%, and agreed with coulometric titration across the cross-validation range.
Watch out: A method paper with a healthy distribution attached — 50 volunteers, no age banding — so it corroborates the healthy range's centre, not its age-specific limits; mM here is mmol/L.
Source: Marvelli A et al. Sweat chloride assay by inductively coupled plasma mass spectrometry: a confirmation test for cystic fibrosis diagnosis. Analytical and bioanalytical chemistry. 2020. PMID: 32691087. Registry ID: none in the record. MeSH: Adult · Case-Control Studies · Chlorides/analysis* · Cystic Fibrosis/diagnosis* · Humans · Limit of Detection · Mass Spectrometry/methods* · Middle Aged · Reproducibility of Results · Sweat/chemistry*
Card 4 — Synthesis — sweat chloride reference values
Study: Synthesis
Population: 3 reports on 3 different measurands: chloride by ion-selective electrode (282 healthy subjects), sodium-chloride conductivity (35 healthy subjects) and chloride by ICP-MS (50 healthy volunteers).
Summary: Synthesis — sweat chloride reference values
Result: Healthy sweat chloride centres in the teens-to-low-20s mmol/L and rises with age until about 19; no healthy group overlapped the CF range on chloride itself. The tension that prints at weight: healthy babies' conductivity range (18–60 mmol/L) reaches the 60 mmol/L decision level, so the screening measurand and the confirmatory measurand behave differently at the threshold. No report was refused; the beta-adrenergic sweat test (PMID 36193559, evaporimetry) is a different measurand, named in prose only.
Watch out: No anchor covers healthy infants' chloride by the reference collection method — the infant limb rests on conductivity, and that substitution prints wherever infant values are quoted.
Source: Synthesis of the reports carded above; no additional source.