SourceMed · Shelf #8472 in the ask interface
Salivary cortisol reference values — time-of-day intervals of 3.6–35.1 nmol/L at awakening and down to the detection limit–10.3 nmol/L in the late afternoon in 120 healthy Danes (RIA), a late-night LC-MS/MS interval of 0.17–0.97 µg/L (≈0.47–2.68 nmol/L) in 100 volunteers with a +51.8% immunoassay bias, and nighttime reproducibility ICC 0.78
Shelf #8472 · Diabetes, glucose & metabolism
PHYSIOLOGY — ESTABLISHED — a salivary cortisol number is meaningless without its clock time and assay, and the intervals print by both: by radioimmunoassay, 3.6–35.1 nmol/L at awakening, 7.6–39.4 nmol/L at the 20-minute post-awakening peak and from the detection limit (1.59 nmol/L) to 10.3 nmol/L in the late afternoon; late-night by LC-MS/MS, 0.17–0.97 µg/L (≈0.47–2.68 nmol/L), with the immunoassay showing a +51.8% positive bias over LC-MS/MS printed at weight; nighttime values were reproducible in healthy volunteers (ICC 0.78), and non-pregnant salivary ranges transferred to pregnancy and oral-contraceptive users even though serum ranges do not
Stamped: 2026-11-28.
Evidence published: 2003–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy people, what are the salivary cortisol reference values — what time-of-day intervals did 120 healthy Danes give, what late-night interval did 100 healthy volunteers give by LC-MS/MS, how reproducible is nighttime salivary cortisol in healthy volunteers, and do healthy pregnant women and women on oral contraceptives stay inside the healthy women's ranges?
Balance of the evidence
4 reports: a radioimmunoassay reference-interval derivation (120 healthy Danes), an LC-MS/MS late-night interval and method-comparison study (100 healthy volunteers + 50 consecutive patients), a nighttime reproducibility study (20 healthy volunteers with Cushing's, obese, referral and late-pregnancy comparison groups) and a pregnancy / oral-contraceptive transferability study (41 pregnant women, 42 controls, 12 women on oral contraceptives — its abstract prints no salivary values and none are printed from it; its carded content is the transferability finding). Cross-points in prose only, never re-carded: late-night salivary cortisol diagnostic accuracy for Cushing's syndrome (#6484), the cortisol awakening response (#7084), cortisol pulsatility / circadian pattern (#6498) and the serum steroid panel by LC-MS/MS (#7322). Urinary free cortisol reference values were searched inside this census and did not compose separately.
MeSH: Adult · Age Factors · Body Mass Index · Circadian Rhythm · Denmark · Female · Humans · Hydrocortisone/analysis* · Male · Radioimmunoassay/methods*,standards* · Reference Values · Saliva/chemistry* · Sex Factors · Smoking · Surveys and Questionnaires · Adolescent · Case-Control Studies · Chromatography, Liquid/standards · Circadian Rhythm/physiology · Cortisone/analysis*,metabolism · Cushing Syndrome/diagnosis*,metabolism · Healthy Volunteers · Hydrocortisone/analysis*,metabolism · Middle Aged · Pituitary-Adrenal Function Tests/methods,standards · Predictive Value of Tests · Reproducibility of Results · Saliva/chemistry*,metabolism · Tandem Mass Spectrometry/methods,standards* · Young Adult · Anti-Inflammatory Agents* · Area Under Curve · Creatinine/metabolism,urine · Cushing Syndrome/drug therapy,metabolism,urine · Dexamethasone* · Hydrocortisone/chemistry,metabolism*,urine · Obesity/metabolism,urine · Pregnancy · Prospective Studies · ROC Curve · Saliva/chemistry,metabolism* · Adrenal Insufficiency/blood,diagnosis · Contraceptives, Oral · Cushing Syndrome/blood,diagnosis · Hydrocortisone/analysis*,blood*
Cards (5)
Card 1 — Time-of-day RIA intervals (Hansen 2003, Scand J Clin Lab Invest — 120 healthy Danes): 3.6–35.1 nmol/L at awakening, late afternoon down to 10.3 nmol/L
Study: Reference-interval derivation study (primary report)
Population: 120 healthy individuals performing their routine work; commercial radioimmunoassay evaluated against certified reference material (recovery 97%, detection limit 1.59 nmol/L).
Summary: Time-of-day RIA intervals (Hansen 2003, Scand J Clin Lab Invest — 120 healthy Danes): 3.6–35.1 nmol/L at awakening, late afternoon down to 10.3 nmol/L
Result: Reference intervals: 3.6–35.1 nmol/L at awakening (05:27–07:27), 7.6–39.4 nmol/L for the peak 20 minutes after awakening, and from the detection limit (1.59 nmol/L) to 10.3 nmol/L in the late afternoon (17:00–19:00). Awakening-to-peak reactivity was 82%, 18% of subjects decreased after awakening, and values were not affected by age, BMI, gender or smoking.
Watch out: Radioimmunoassay-era intervals — the LC-MS/MS card below shows immunoassays read high against mass spectrometry, so these nmol/L limits must not be applied to LC-MS/MS results. Sampling windows are clock-bound; a value outside its window has no interval here.
Source: Hansen AM et al. Evaluation of a radioimmunoassay and establishment of a reference interval for salivary cortisol in healthy subjects in Denmark. Scandinavian journal of clinical and laboratory investigation. 2003. PMID: 12940639. Registry ID: none in the record. MeSH: Adult · Age Factors · Body Mass Index · Circadian Rhythm · Denmark · Female · Humans · Hydrocortisone/analysis* · Male · Radioimmunoassay/methods*,standards* · Reference Values · Saliva/chemistry* · Sex Factors · Smoking · Surveys and Questionnaires
Card 2 — Late-night LC-MS/MS interval (Ponzetto 2020, J Endocrinol Invest — 100 healthy volunteers): cortisol 0.17–0.97 µg/L (≈0.47–2.68 nmol/L); immunoassay bias +51.8%
Study: Reference-interval and method-comparison study
Population: 100 healthy volunteers and 50 consecutive patients with suspected hypercortisolism; LC-MS/MS compared with electrochemiluminescence immunoassay.
Summary: Late-night LC-MS/MS interval (Ponzetto 2020, J Endocrinol Invest — 100 healthy volunteers): cortisol 0.17–0.97 µg/L (≈0.47–2.68 nmol/L); immunoassay bias +51.8%
Result: Late-night salivary reference intervals by LC-MS/MS: cortisol 0.17–0.97 µg/L (≈0.47–2.68 nmol/L at ×2.76), cortisone 0.84–4.85 µg/L and cortisol:cortisone ratio 0.08–0.30. The method comparison showed a positive bias of 51.8% for the immunoassay over LC-MS/MS.
Watch out: The +51.8% immunoassay bias is headline material: a late-night value near an immunoassay-derived threshold can be a method artefact. The patient limb of this study is diagnostic-accuracy material for pack #6484's question and is not carded here.
Source: Ponzetto F et al. Reference ranges of late-night salivary cortisol and cortisone measured by LC-MS/MS and accuracy for the diagnosis of Cushing's syndrome. Journal of endocrinological investigation. 2020. PMID: 32772255. Registry ID: none in the record. MeSH: Adolescent · Adult · Case-Control Studies · Chromatography, Liquid/standards · Circadian Rhythm/physiology · Cortisone/analysis*,metabolism · Cushing Syndrome/diagnosis*,metabolism · Female · Healthy Volunteers · Humans · Hydrocortisone/analysis*,metabolism · Male · Middle Aged · Pituitary-Adrenal Function Tests/methods,standards · Predictive Value of Tests · Reference Values · Reproducibility of Results · Saliva/chemistry*,metabolism · Tandem Mass Spectrometry/methods,standards* · Young Adult
Card 3 — Nighttime reproducibility (Viardot 2005, J Clin Endocrinol Metab — repeated sampling in 20 healthy volunteers): intraclass correlation 0.78
Study: Reproducibility study with comparison groups
Population: 20 healthy volunteers with repeated nighttime salivary cortisol, compared with 12 Cushing's patients, 14 referrals in whom Cushing's was excluded, 16 obese patients and 20 women in late pregnancy.
Summary: Nighttime reproducibility (Viardot 2005, J Clin Endocrinol Metab — repeated sampling in 20 healthy volunteers): intraclass correlation 0.78
Result: Nighttime salivary cortisol showed low day-to-day variability in healthy volunteers (intraclass correlation coefficient 0.78). The ROC-estimated cutoff of 6.1 nmol/L (0.22 µg/dL as printed) gave sensitivity and specificity of 100% in that sample for Cushing's syndrome; in late pregnancy, preserved but higher diurnal variation reduced specificity to 75%.
Watch out: The 100% sensitivity / specificity rests on 12 Cushing's patients against small comparison groups — a spectrum-limited diagnostic limb printed for its reproducibility content (ICC 0.78 in 20 volunteers), not as a settled diagnostic accuracy figure; that question is homed at #6484.
Source: Viardot A et al. Reproducibility of nighttime salivary cortisol and its use in the diagnosis of hypercortisolism compared with urinary free cortisol and overnight dexamethasone suppression test. The Journal of clinical endocrinology and metabolism. 2005. PMID: 16014408. Registry ID: none in the record. MeSH: Adult · Anti-Inflammatory Agents* · Area Under Curve · Creatinine/metabolism,urine · Cushing Syndrome/drug therapy,metabolism,urine · Dexamethasone* · Female · Humans · Hydrocortisone/chemistry,metabolism*,urine · Obesity/metabolism,urine · Pregnancy · Prospective Studies · ROC Curve · Reproducibility of Results · Saliva/chemistry,metabolism*
Card 4 — Pregnancy and oral contraceptives (Ambroziak 2015, Clin Endocrinol — Roche ECLIA): salivary ranges from healthy women transferred, serum ranges did not
Study: Transferability study (figure-free at abstract level)
Population: 41 healthy pregnant women (each trimester and postpartum), 42 healthy women controls and 12 healthy women on oral contraceptives.
Summary: Pregnancy and oral contraceptives (Ambroziak 2015, Clin Endocrinol — Roche ECLIA): salivary ranges from healthy women transferred, serum ranges did not
Result: Despite elevation of morning serum cortisol in the second and third trimesters, morning and late-night salivary cortisol did not differ significantly from controls in any trimester (P > 0.5), postpartum values fell below late-pregnancy values, and values in women on oral contraceptives also did not differ from healthy women. The abstract prints no salivary values, and none are printed from this anchor — its carded content is the transferability finding.
Watch out: Small oral-contraceptive group (n = 12) and a single immunoassay platform (Roche ECLIA) — the transfer finding is about salivary versus serum behaviour, and does not extend these ranges to LC-MS/MS measurement.
Source: Ambroziak U et al. The morning and late-night salivary cortisol ranges for healthy women may be used in pregnancy. Clinical endocrinology. 2015. PMID: 26173372. Registry ID: none in the record. MeSH: Adrenal Insufficiency/blood,diagnosis · Adult · Contraceptives, Oral · Cushing Syndrome/blood,diagnosis · Female · Humans · Hydrocortisone/analysis*,blood* · Pregnancy · Prospective Studies · Saliva/chemistry*
Card 5 — Synthesis — salivary cortisol reference values
Study: Synthesis
Population: 4 reports: 120 healthy Danes (RIA intervals), 100 healthy volunteers (LC-MS/MS late-night interval), 20 healthy volunteers (reproducibility) and 95 women across pregnancy / control / oral-contraceptive groups (transferability, figure-free abstract).
Summary: Synthesis — salivary cortisol reference values
Result: Intervals exist by clock time and by platform, and the two must travel together: morning values are an order of magnitude above late-night values, and immunoassays read about 52% above LC-MS/MS at night. Non-pregnant salivary ranges may be used in pregnancy and in oral-contraceptive users. No report was refused; diagnostic-accuracy (#6484), awakening-response (#7084), circadian-pattern (#6498) and serum-panel (#7322) packs are cross-pointed in prose only.
Watch out: One anchor is figure-free at abstract level and one diagnostic limb is spectrum-limited — both print as such on their cards, and neither carries a number on this pack.
Source: Synthesis of the reports carded above; no additional source.