SourceMed · Shelf #8489 in the ask interface

Serum ferritin for iron deficiency and overload — three overlapping syntheses: a specific rule-in test at ~30 µg/L (Cochrane pooled sensitivity 79% / specificity 98%, DOR 140) whose threshold is unsettled, with a much weaker overload limb (DOR 8, very low certainty)

Shelf #8489 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — a specific rule-in test whose threshold is unsettled: at a fixed 30 µg/L threshold in non-healthy adults the Cochrane pool gives sensitivity 79% (95% CI 58–91) and specificity 98% (91–100), diagnostic odds ratio 140 (low-certainty) — ferritin misses roughly one in five iron-deficient patients while rarely flagging the iron-replete; the 2013 cut-off meta-analysis likewise finds the 25–30 µg/L band best (0.877 / 0.944, DOR 101.42, summary ROC area 0.9497), and the 1992 overview found ferritin radioimmunoassay by far the most powerful test reviewed (ROC area 0.95) with likelihood-ratio lines that split by inflammatory, liver or neoplastic comorbidity — ferritin is an acute-phase reactant, and that confound is headline material. The iron-overload limb rests on very-low-certainty evidence (modelled sensitivity ~80% at a supposed 65% specificity, DOR 8) and prints at that weight.

Stamped: 2026-11-28.

Evidence published: 1992–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In people being assessed for iron status, how accurately does serum/plasma ferritin diagnose iron deficiency (against bone-marrow iron) and iron overload (against liver iron) — and at what threshold?

Balance of the evidence

3 syntheses, all counted as syntheses, with overlapping primary pools (the 2013 meta-analysis's pool overlaps the Cochrane pool) — no combined N is printed; the pools report 55 studies against bone-marrow histology (1992), 108 studies with 72 studies / 6,059 participants for iron deficiency and 36 studies / 1,927 participants for overload (Cochrane 2021), and 14 studies grouped by cut-off band (2013). No single sensitivity/specificity pair is printed in the 1992 record, and none is taken from it — it contributes the ROC area and the population-split likelihood-ratio structure only. Nothing in this base supports ferritin screening of asymptomatic people, per the Cochrane authors' own conclusion (healthy-screenee evidence sparse and very low-certainty).

MeSH: Anemia, Hypochromic/blood,diagnosis* · Clinical Laboratory Techniques · Ferritins/blood · Humans · Likelihood Functions · ROC Curve · Adolescent · Adult · Aged · Anemia, Iron-Deficiency/blood*,diagnosis · Bias · Biomarkers/blood · Child · Child, Preschool · Female · Ferritins/blood* · Infant · Iron Overload/blood*,diagnosis · Male · Middle Aged · Pregnancy · Pregnant People · Sensitivity and Specificity · Young Adult · Anemia, Iron-Deficiency/blood,diagnosis* · Iron Deficiencies* · Randomized Controlled Trials as Topic · Reference Standards

Cards (4)

Card 1 — Systematic overview (Guyatt 1992, Journal of General Internal Medicine — 55 studies vs bone-marrow histology): ferritin radioimmunoassay by far the most powerful test, ROC area 0.95; likelihood-ratio lines split by inflammatory/liver/neoplastic disease

Study: Systematic overview (synthesis)

Population: 55 studies (from 1,179 citations) reporting laboratory tests against histologic bone-marrow examination in at least 50% of an identifiable patient group, with duplicate quality assessment and extraction.

Summary: Systematic overview (Guyatt 1992, Journal of General Internal Medicine — 55 studies vs bone-marrow histology): ferritin radioimmunoassay by far the most powerful test, ROC area 0.95; likelihood-ratio lines split by inflammatory/liver/neoplastic disease

Result: Serum ferritin radioimmunoassay was by far the most powerful test reviewed, with an area under the receiver operating characteristic curve of 0.95. Test properties differed for patients with inflammatory, liver or neoplastic disease vs patients without these conditions, and likelihood-ratio lines allowing interpretation across the full range of ferritin values were constructed separately for the individual populations. The authors conclude ferritin radioimmunoassay, appropriately interpreted, can be applied to the complete range of patients.

Watch out: No single sensitivity/specificity pair is printed in this record and none may be quoted from it — any pair attributed to Guyatt 1992 would be invented. The durable finding is structural: one ferritin value does not mean one thing — the interpretation lines split by comorbidity because ferritin rises with inflammation. 1992 radioimmunoassay era.

Source: Guyatt GH et al. Laboratory diagnosis of iron-deficiency anemia: an overview. Journal of general internal medicine. 1992. PMID: 1487761. Registry ID: none in the record. MeSH: Anemia, Hypochromic/blood,diagnosis* · Clinical Laboratory Techniques · Ferritins/blood · Humans · Likelihood Functions · ROC Curve

Card 2 — Cochrane review (Garcia-Casal 2021, Cochrane Database of Systematic Reviews — 108 studies): at 30 µg/L in non-healthy adults, sensitivity 79% (58–91) / specificity 98% (91–100), DOR 140; overload limb DOR 8, very low certainty

Study: Systematic review and meta-analysis (Cochrane synthesis)

Population: 108 studies of serum/plasma ferritin against bone-marrow iron (iron deficiency) or liver iron (iron overload): 72 studies / 6,059 participants for iron deficiency (63 studies in 5,042 adults presenting for medical care; 5 studies in apparently healthy people) and 36 studies / 1,927 participants for iron overload, all in non-healthy populations; QUADAS-2 and GRADE applied.

Summary: Cochrane review (Garcia-Casal 2021, Cochrane Database of Systematic Reviews — 108 studies): at 30 µg/L in non-healthy adults, sensitivity 79% (58–91) / specificity 98% (91–100), DOR 140; overload limb DOR 8, very low certainty

Result: For iron deficiency in non-healthy adults at a fixed 30 µg/L threshold (9 studies, 512 participants, low-certainty): pooled sensitivity 79% (95% CI 58–91), specificity 98% (91–100), diagnostic odds ratio 140. Author-proposed thresholds across studies ranged 12–200 µg/L; in adults presenting for care the estimated DOR was 50. In apparently healthy adults, three studies reported sensitivities of 63–100% at study-specific optimum cut-offs with specificities of 92–98%, at very low certainty. For iron overload (very low-certainty): for 1,000 subjects at 42% prevalence and a supposed 65% specificity, the modelled sensitivity was ~80%, DOR 8. The authors conclude there is insufficient evidence that ferritin performs similarly when screening asymptomatic people.

Watch out: The fixed-threshold pair rests on 9 studies and 512 participants at low certainty, with a wide sensitivity interval (58–91) — the 'misses one in five' reading is the point estimate, not a bound. The overload limb is very-low-certainty and modelled (a supposed specificity), and prints at that weight, never beside the deficiency pair as an equal.

Source: Garcia-Casal MN et al. Serum or plasma ferritin concentration as an index of iron deficiency and overload. The Cochrane database of systematic reviews. 2021. PMID: 34028001. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Anemia, Iron-Deficiency/blood*,diagnosis · Bias · Biomarkers/blood · Child · Child, Preschool · Female · Ferritins/blood* · Humans · Infant · Iron Overload/blood*,diagnosis · Male · Middle Aged · Pregnancy · Pregnant People · Sensitivity and Specificity · Young Adult

Card 3 — Cut-off meta-analysis (Yu 2013, Journal of Hygiene Research — 14 studies by cut-off band): the 25–30 µg/L band performed best (sensitivity 0.877 / specificity 0.944, DOR 101.42, summary ROC area 0.9497) — TYPE-FLAG: typed in part 'Randomized Controlled Trials as Topic', a meta-analysis on substance

Study: Meta-analysis (synthesis) — TYPE-FLAG: the record is typed in part 'Randomized Controlled Trials as Topic' although a meta-analysis on substance; counted as a synthesis

Population: 14 studies of serum ferritin cut-off values for identifying iron deficiency, grouped into 12–20 µg/L, 25–30 µg/L and 36–60 µg/L bands, with pooled diagnostic indicators and summary ROC curves per band.

Summary: Cut-off meta-analysis (Yu 2013, Journal of Hygiene Research — 14 studies by cut-off band): the 25–30 µg/L band performed best (sensitivity 0.877 / specificity 0.944, DOR 101.42, summary ROC area 0.9497) — TYPE-FLAG: typed in part 'Randomized Controlled Trials as Topic', a meta-analysis on substance

Result: The 12–20 µg/L band had the lowest pooled sensitivity (0.767, 95% CI 0.705–0.821) but the highest specificity (0.959, 0.934–0.976). The 25–30 µg/L band had the highest sensitivity (0.877, 0.799–0.933) with specificity 0.944 (0.888–0.977), the highest diagnostic odds ratio (101.42, 36.137–284.64), the largest summary ROC area (0.9497 ± 0.039) and the Q* index nearest 1 (0.8901 ± 0.052). The 36–60 µg/L band was lower on both (0.836 / 0.876). The band ranking survived removing studies with samples under 50 and studies from Chinese authors.

Watch out: Its primary pool overlaps the Cochrane pool — the convergence on ~30 µg/L is convergence of overlapping syntheses, not independent replication. Chinese-language journal with English abstract, fetched and verified. Band-level pooling cannot name a single best cut-off within the 25–30 band.

Source: Yu D et al. [Meta-analysis of studies on cut-off value of serum ferritin for identifying iron deficiency]. Wei sheng yan jiu = Journal of hygiene research. 2013. PMID: 23654098. Registry ID: none in the record. MeSH: Anemia, Iron-Deficiency/blood,diagnosis* · Ferritins/blood* · Humans · Iron Deficiencies* · Randomized Controlled Trials as Topic · Reference Standards

Card 4 — Synthesis — specific, threshold-unsettled, comorbidity-confounded; the overload limb is weak

Study: Synthesis

Population: 3 syntheses with overlapping pools (55 studies; 108 studies; 14 studies) — counted as syntheses, never summed.

Summary: Synthesis — specific, threshold-unsettled, comorbidity-confounded; the overload limb is weak

Result: Three decades of synthesis agree on the shape: ferritin is the strongest single laboratory test for iron deficiency (ROC area 0.95 in 1992), highly specific at ~30 µg/L (0.94–0.98 across pools) but imperfectly sensitive (0.79–0.88), so a low ferritin rules iron deficiency in far better than a normal ferritin rules it out. The threshold is genuinely unsettled — author-proposed cut-offs span 12–200 µg/L — and the 1992 overview's population-split likelihood lines state why: inflammation, liver and neoplastic disease move ferritin independently of iron stores. The overload limb (DOR 8, very low certainty) prints at a fraction of the deficiency limb's weight. Stamp PREDICTIVE PERFORMANCE — a specific rule-in test whose threshold is unsettled. Cross-point in prose only: ferritin reference intervals (pack #7254) are a values question, not this accuracy question.

Watch out: Healthy-screenee evidence is sparse and very low-certainty in the Cochrane pool; nothing here supports screening asymptomatic people. All accuracy is against invasive reference standards (bone-marrow / liver iron) in mostly non-healthy, care-presenting populations.

Source: Synthesis of the reports carded above; no additional source.