SourceMed · Shelf #8497 in the ask interface
EORTC QLQ-EN24 (endometrial cancer module) measurement properties — 3 reports, combined N=665: three convergent validations (alphas 0.74–0.97, Mexican floor 0.659), with sexuality items missing or unanswered in 19–65% of respondents in every anchor
Shelf #8497 · Cancer
MEASUREMENT PROPERTIES — supported, with a sexuality-item caveat that runs through every anchor — three validations (combined N=665) agree on structure and reliability (alphas 0.74–0.86 at derivation, 0.77–0.97 independently, 0.659–0.887 in the Mexican transport, the 0.659 floor printed), and all three independently surface the same weakness: sexuality items are missing or unanswered in 19–65% of respondents, so the sexual/vaginal scales carry that completion caveat.
Stamped: 2026-11-28.
Evidence published: 1990–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the EORTC QLQ-EN24 (the 24-item endometrial cancer module — lymphoedema, urological, gastrointestinal, body-image, sexual/vaginal and treatment-related scales) supplementing the QLQ-C30, in women with endometrial cancer?
Balance of the evidence
3 reports, combined N=665 (268 + 208 + 189) as printed per report. Composition: the EORTC group's own multicentre psychometric validation (2011, typed Validation Study, programme-labelled), one independent three-centre validation (2018, typed Validation Study) and one Mexican-Spanish single-centre validation (2021). Never counted: the Polish report (PMID 24966799, 2014) is a translation-and-pilot report (12 pilot patients, no psychometric coefficients) — a translation limb, never a fourth validation. The Mexican report's five scales associated with overall survival are a prognostic limb, printed as such.
MeSH: Adult · Aged · Aged, 80 and over · Endometrial Neoplasms/psychology* · Female · Humans · Karnofsky Performance Status · Middle Aged · Patient Satisfaction · Psychometrics · Quality of Life* · Reproducibility of Results · Sensitivity and Specificity · Socioeconomic Factors · Surveys and Questionnaires/standards* · Psychiatric Status Rating Scales/standards · Endometrial Neoplasms/diagnosis,psychology* · Language · Mexico · Prospective Studies
Cards (4)
Card 1 — Programme psychometric validation (Greimel 2011, European Journal of Cancer — 268 women across treatment phases; typed Validation Study): multi-trait scaling confirmed the hypothesised structure with no scaling errors; Cronbach alpha 0.74–0.86; item completion <2% missing EXCEPT the sexuality items (19% missing) — programme-labelled: the EORTC group's own validation
Study: Validation study (programme's own, multicentre) — derivation/validation limb
Population: 268 women with endometrial cancer recruited after pelvic surgery, during adjuvant chemotherapy and/or radiotherapy, or after completion of treatment, completing the QLQ-C30, the QLQ-EN24 and a debriefing questionnaire.
Summary: Programme psychometric validation (Greimel 2011, European Journal of Cancer — 268 women across treatment phases; typed Validation Study): multi-trait scaling confirmed the hypothesised structure with no scaling errors; Cronbach alpha 0.74–0.86; item completion <2% missing EXCEPT the sexuality items (19% missing) — programme-labelled: the EORTC group's own validation
Result: Multi-trait scaling confirmed the hypothesised scale structure; internal consistency was good, with Cronbach's alpha 0.74–0.86 (lymphoedema 0.80, urological symptoms 0.75, gastrointestinal symptoms 0.74, body image problems 0.86, sexual/vaginal problems 0.86). Convergent and discriminant validity showed no scaling errors, the module discriminated between clinically different groups, and all items had less than 2% missing values except the sexuality items (19%).
Watch out: Programme-labelled: the developing group's own validation. The 19% sexuality-item missingness appears already here, in the instrument's home sample — it is a property of the items, not of any one translation.
Source: Greimel E et al. Psychometric validation of the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire-Endometrial Cancer Module (EORTC QLQ-EN24). European journal of cancer (Oxford, England : 1990). 2011. PMID: 20851597. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Endometrial Neoplasms/psychology* · Female · Humans · Karnofsky Performance Status · Middle Aged · Patient Satisfaction · Psychometrics · Quality of Life* · Reproducibility of Results · Sensitivity and Specificity · Socioeconomic Factors · Surveys and Questionnaires/standards*
Card 2 — Independent validation (Stukan 2018, European Journal of Cancer Care — 208 women at three centres; typed Validation Study): 100% completion except sexuality items (answered by only 35%); all item-scale correlations exceeded 0.4 for their own scale; Cronbach alpha 0.77–0.97; sexuality data 'should be interpreted with caution', as the authors state
Study: Validation study (independent, three-centre)
Population: 208 women with endometrial cancer before surgery, during adjuvant treatment and in follow-up at three cancer centres, completing the QLQ-C30 and QLQ-EN24.
Summary: Independent validation (Stukan 2018, European Journal of Cancer Care — 208 women at three centres; typed Validation Study): 100% completion except sexuality items (answered by only 35%); all item-scale correlations exceeded 0.4 for their own scale; Cronbach alpha 0.77–0.97; sexuality data 'should be interpreted with caution', as the authors state
Result: The completion rate was 100% except sexuality items, answered by 35% of patients. All item-scale correlations for the multi-item scales exceeded the 0.4 criterion against their own scale and were low against other scales. Internal consistency was satisfactory (Cronbach's alpha 0.77–0.97); discriminance for single-item scales was low. The module discriminated well between clinically different patients, with no scale differences by body mass index ≤30 vs >30.
Watch out: Only 35% answering the sexuality items means the sexual/vaginal scale estimates rest on a self-selected minority — the strongest form of this family's recurring caveat. Single-item-scale discriminance was low, printed as the record states.
Source: Stukan M et al. Independent psychometric validation of European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Endometrial Cancer Module (EORTC QLQ-EN24). European journal of cancer care. 2018. PMID: 28058740. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Endometrial Neoplasms/psychology* · Female · Humans · Middle Aged · Psychiatric Status Rating Scales/standards · Psychometrics · Quality of Life* · Surveys and Questionnaires/standards*
Card 3 — Mexican-Spanish validation (Gallardo-Rincón 2021, Archives of Gynecology and Obstetrics — 189 women, single centre): Cronbach alpha for the five multi-item scales 0.659–0.887 — the 0.659 floor prints; adequate convergent/divergent validity; five scales associated with overall survival (a prognostic limb, printed as such). Slate-vs-record: the slate named this limb 'Coronado'; the fetched record's first author is Gallardo-Rincón — the record governs
Study: Validation study (independent language validation, single centre)
Population: 189 women with endometrial cancer at a single Mexican cancer centre, assessed prospectively with the QLQ-C30 and QLQ-EN24.
Summary: Mexican-Spanish validation (Gallardo-Rincón 2021, Archives of Gynecology and Obstetrics — 189 women, single centre): Cronbach alpha for the five multi-item scales 0.659–0.887 — the 0.659 floor prints; adequate convergent/divergent validity; five scales associated with overall survival (a prognostic limb, printed as such). Slate-vs-record: the slate named this limb 'Coronado'; the fetched record's first author is Gallardo-Rincón — the record governs
Result: Most functional scales reported high values and most symptom scales low; compliance was high and internal-consistency tests demonstrated adequate convergent and divergent validity. Cronbach's alpha coefficients of the five multi-item scales ranged 0.659–0.887. Scales distinguished clinically distinct groups, particularly by serum albumin; the urological, gastrointestinal, body-image, pelvic-pain and taste-change scales were significantly associated with overall survival. The authors caution that conclusions from sexual-function scales should be handled carefully.
Watch out: One scale falls below alpha 0.70 (0.659) in this transport — printed. The survival associations are prognostic, not psychometric, and the single-centre sample is the base's narrowest spectrum.
Source: Gallardo-Rincón D et al. Validation of the QLQ-EN24 instrument for the assessment of health-related quality of life for women with endometrial cancer in México. Archives of gynecology and obstetrics. 2021. PMID: 33582853. Registry ID: none in the record. MeSH: Endometrial Neoplasms/diagnosis,psychology* · Female · Humans · Language · Mexico · Prospective Studies · Psychometrics · Quality of Life* · Reproducibility of Results · Surveys and Questionnaires/standards*
Card 4 — Synthesis — three validations, one recurring caveat: MEASUREMENT PROPERTIES — supported, with a sexuality-item caveat
Study: Synthesis
Population: 3 reports, combined N=665 (268 + 208 + 189). One programme validation, two independent validations (one three-centre, one single-centre).
Summary: Synthesis — three validations, one recurring caveat: MEASUREMENT PROPERTIES — supported, with a sexuality-item caveat
Result: All three reports confirm the scale structure and acceptable-to-strong reliability, and all three independently surface the same weakness — sexuality items missing in 19% (programme sample) or answered by only 35% (independent sample) — so the caveat is a property of the instrument, printed on the stamp. Refused: PMID 24966799 (translation-and-pilot report, 12 pilot patients, no coefficients — never a validation). One slate-vs-record author discrepancy (33582853) resolved in favour of the record, noted on its card.
Watch out: With only three reports and one of them the programme's own, independent replication is thinner than for the OV28/BM22 modules; no responsiveness or MCID anchor is in this base.
Source: Synthesis of the reports carded above; no additional source.