SourceMed · Shelf #8538 in the ask interface
Distress Thermometer in cancer — 3 reports: a 121-patient feasibility pilot printing no accuracy coefficient, a pooled analysis of 38 analyses (6,414 patients) and a 962-patient Spanish validation, both accuracy anchors showing the same shape — NPV 93–97% against PPV ~34–35% for depression
Shelf #8538 · Cancer
PREDICTIVE PERFORMANCE — a rule-out screen, poor at ruling in: across both accuracy anchors the pattern is identical — for depression, pooled negative predictive value 93.4% against a positive predictive value of 34.2%, and in the Spanish validation NPV 97% against PPV 35% at cut-off 5 — so roughly two of three screen-positives are not cases. The Distress Thermometer is a first-stage screen only, exactly as the pooled analysis's author concludes; it cannot be used alone to diagnose depression, anxiety or distress.
Stamped: 2026-11-28.
Evidence published: 1998–2013.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with cancer, how accurately does the Distress Thermometer (a single-item 0–10 visual-analogue distress rating, with its Problem List) screen for depression, anxiety and distress — and is the two-stage approach feasible in clinic?
Balance of the evidence
3 reports: 1 feasibility pilot (121 patients, no accuracy coefficient printed and none may be printed from it), 1 pooled analysis counted as a synthesis (38 analyses of ultra-short methods, 19 of the Distress Thermometer alone, 6,414 unique patients — the printed pairs are the ultra-short-method pools, labelled as such on the card, with DT-alone results stated by the record to be similar), and 1 validation study (962 patients). Composition prints as such: the derivation-era limb is a feasibility pilot in older men with prostate cancer, not an accuracy study. No registry IDs in any record.
MeSH: Aged · Aged, 80 and over · Feasibility Studies · Humans · Male · Mass Screening/methods* · Middle Aged · Patient Compliance · Pilot Projects · Prostatic Neoplasms/psychology* · Psychiatric Status Rating Scales* · Quality of Life · Surveys and Questionnaires · Time Factors · Anxiety/diagnosis · Depression/diagnosis · Mental Disorders/diagnosis · Mood Disorders/complications*,diagnosis* · Neoplasms/complications*,psychology* · Predictive Value of Tests · Psychiatric Status Rating Scales · Reproducibility of Results · Treatment Outcome · Adult · Affective Symptoms/diagnosis*,etiology,psychology · Anxiety/diagnosis,etiology,psychology · Counseling/statistics & numerical data · Depression/diagnosis,etiology,psychology · Female · Neoplasms/complications,psychology*,therapy · Psychometrics/methods,standards* · ROC Curve · Sensitivity and Specificity · Spain · Stress, Psychological/diagnosis*,etiology,psychology · Surveys and Questionnaires/standards*
Cards (4)
Card 1 — Feasibility pilot (Roth 1998, Cancer — prostate carcinoma clinic two-stage pilot, 121 patients): 8 (6.6%) refused; 31% of evaluable patients referred on HADS ≥15 or Thermometer ≥5; 17 of 29 referred patients evaluated, 8 of 17 meeting DSM-IV criteria — a feasibility pilot printing no accuracy coefficient, and none may be printed from it
Study: Feasibility pilot study (two-stage screening programme report) — no accuracy coefficient is printed in this record
Population: 121 men with prostate carcinoma in an oncology clinic pilot of a two-stage approach: the Hospital Anxiety and Depression Scale (HADS) and the Distress Thermometer as first-stage pencil-and-paper screens, with referral to the psychiatric liaison for patients scoring HADS ≥15 or Thermometer ≥5.
Summary: Feasibility pilot (Roth 1998, Cancer — prostate carcinoma clinic two-stage pilot, 121 patients): 8 (6.6%) refused; 31% of evaluable patients referred on HADS ≥15 or Thermometer ≥5; 17 of 29 referred patients evaluated, 8 of 17 meeting DSM-IV criteria — a feasibility pilot printing no accuracy coefficient, and none may be printed from it
Result: Compliance was excellent: only 8 of 121 patients (6.6%) refused. Thirty-one percent of evaluable patients were referred on elevated scores. Seventeen of 29 referred patients were actually evaluated, and 8 of 17 met DSM-IV criteria for a psychiatric disorder. The authors note these older men were reluctant to agree to evaluation and treatment, and that the method needs further testing.
Watch out: A pilot in one prostate-cancer clinic of older men: it establishes that patients will complete the screen, not how accurately the Thermometer performs — and the referral chain leaked (17 of 29 evaluated), which is itself part of the feasibility finding.
Source: Roth AJ et al. Rapid screening for psychologic distress in men with prostate carcinoma: a pilot study. Cancer. 1998. PMID: 9587123. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Feasibility Studies · Humans · Male · Mass Screening/methods* · Middle Aged · Patient Compliance · Pilot Projects · Prostatic Neoplasms/psychology* · Psychiatric Status Rating Scales* · Quality of Life · Surveys and Questionnaires · Time Factors
Card 2 — Pooled analysis (Mitchell 2007, Journal of clinical oncology — 38 analyses of ultra-short methods, 19 of the Distress Thermometer alone, 6,414 unique patients): pooled depression sensitivity 78.4% / specificity 66.8% / PPV 34.2% / NPV 93.4%; anxiety 77.3% / 56.6%; distress 78.3% / 66.5% — the printed pairs are the ultra-short-method pools, labelled as such; results using the DT alone were similar, as the record states
Study: Pooled analysis / meta-analysis of diagnostic accuracy studies — counted as a synthesis, never as a primary validation
Population: 6,414 unique patients with cancer across 38 diagnostic-validity analyses of ultra-short screening methods (fewer than five questions), 19 of them assessing the Distress Thermometer alone, identified by a literature search limited to diagnostic validity studies in cancer settings.
Summary: Pooled analysis (Mitchell 2007, Journal of clinical oncology — 38 analyses of ultra-short methods, 19 of the Distress Thermometer alone, 6,414 unique patients): pooled depression sensitivity 78.4% / specificity 66.8% / PPV 34.2% / NPV 93.4%; anxiety 77.3% / 56.6%; distress 78.3% / 66.5% — the printed pairs are the ultra-short-method pools, labelled as such; results using the DT alone were similar, as the record states
Result: The pooled ability of ultra-short methods to detect depression was sensitivity 78.4%, specificity 66.8%, positive predictive value 34.2% and negative predictive value 93.4% — very good at excluding possible cases, poor at confirming a suspected diagnosis. For anxiety: sensitivity 77.3%, specificity 56.6% (PPV 55.2%, NPV 80.25%); for distress: sensitivity 78.3%, specificity 66.5% (PPV 59.7%, NPV 82.8%). Results using the Distress Thermometer alone were similar. The author concludes ultra-short methods cannot be used alone to diagnose depression, anxiety or distress but may be considered a first-stage screen to rule out cases of depression.
Watch out: The pooled pairs pool all ultra-short methods, not the Thermometer alone; the record states DT-alone results were similar but prints no separate DT-alone pair, so no DT-specific coefficient may be quoted from this card beyond that statement.
Source: Mitchell AJ et al. Pooled results from 38 analyses of the accuracy of distress thermometer and other ultra-short methods of detecting cancer-related mood disorders. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 2007. PMID: 17846453. Registry ID: none in the record. MeSH: Anxiety/diagnosis · Depression/diagnosis · Humans · Mass Screening/methods* · Mental Disorders/diagnosis · Mood Disorders/complications*,diagnosis* · Neoplasms/complications*,psychology* · Predictive Value of Tests · Psychiatric Status Rating Scales · Reproducibility of Results · Time Factors · Treatment Outcome
Card 3 — Spanish validation (Martínez 2013, Supportive care in cancer — 962 adult cancer patients): DT correlated with BSI-18 symptoms and Problem List emotional problems; AUC 0.82 (95% CI 0.79–0.85); at cut-off 5, sensitivity 90% / specificity 64% / PPV 35% / NPV 97%; 81.3% of clinically distressed patients had not sought or were not receiving psychosocial support
Study: Validation study (primary report)
Population: 962 adult cancer patients (a heterogeneous sample) in Spain completing the Distress Thermometer, its Problem List, the Brief Symptom Inventory-18 (BSI-18) and a psychosocial questionnaire.
Summary: Spanish validation (Martínez 2013, Supportive care in cancer — 962 adult cancer patients): DT correlated with BSI-18 symptoms and Problem List emotional problems; AUC 0.82 (95% CI 0.79–0.85); at cut-off 5, sensitivity 90% / specificity 64% / PPV 35% / NPV 97%; 81.3% of clinically distressed patients had not sought or were not receiving psychosocial support
Result: The DT was significantly correlated with BSI-18 symptoms and the emotional problems listed on the Problem List. ROC analysis showed diagnostic accuracy with area under the curve 0.82 (95% CI 0.79–0.85). At the selected cut-off of 5: sensitivity 90%, specificity 64%, positive predictive value 35% and negative predictive value 97% — adequate for screening, limited for case-finding, in the authors' framing. Finally, 81.30% of patients with clinical distress had not sought or were not receiving professional psychosocial support.
Watch out: A single-country validation against another self-report instrument (BSI-18), not against a diagnostic interview: its PPV of 35% at cut-off 5 means most screen-positives are not BSI-18 cases, which is the pack's headline pattern, not a defect of this one study.
Source: Martínez P et al. The Distress Thermometer in Spanish cancer patients: convergent validity and diagnostic accuracy. Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer. 2013. PMID: 23832312. Registry ID: none in the record. MeSH: Adult · Affective Symptoms/diagnosis*,etiology,psychology · Aged · Anxiety/diagnosis,etiology,psychology · Counseling/statistics & numerical data · Depression/diagnosis,etiology,psychology · Female · Humans · Male · Middle Aged · Neoplasms/complications,psychology*,therapy · Psychometrics/methods,standards* · ROC Curve · Reproducibility of Results · Sensitivity and Specificity · Spain · Stress, Psychological/diagnosis*,etiology,psychology · Surveys and Questionnaires/standards*
Card 4 — Synthesis — a feasible first-stage screen whose accuracy anchors agree: it rules out far better than it rules in
Study: Synthesis
Population: 3 reports: a 121-patient feasibility pilot (no accuracy coefficient), a pooled analysis of 38 analyses / 6,414 unique patients (counted as a synthesis), and a 962-patient validation — 1998–2013.
Summary: Synthesis — a feasible first-stage screen whose accuracy anchors agree: it rules out far better than it rules in
Result: Feasibility is established by the pilot (6.6% refusal). Accuracy rests on the two later anchors, which agree in shape: negative predictive values of 93.4% (pooled, depression) and 97% (Spanish, cut-off 5) against positive predictive values of 34.2% and 35% — roughly two of three screen-positives are not cases. The stamp is therefore PREDICTIVE PERFORMANCE — a rule-out screen, poor at ruling in, as rowed, and the face presents the Thermometer as a first-stage screen only. No report was refused on this pack; the pilot's absence of any accuracy coefficient is printed on its card rather than filled in from the later literature.
Watch out: Neither accuracy anchor validates the Thermometer against a structured diagnostic interview in a primary sample — the pool synthesises other studies and the Spanish study uses a self-report criterion — so the rule-out performance is the supported claim and any case-finding use goes beyond this base.
Source: Synthesis of the reports carded above; no additional source.