SourceMed · Shelf #8558 in the ask interface

Pattern-reversal VEP normative values — 4 cohorts, 260 volunteers: mean P100 latency spans 94.6–104.6 ms and tracks check size and protocol; women show shorter latency and higher amplitude

Shelf #8558 · Brain, stroke & mind

PHYSIOLOGY — ESTABLISHED — the P100 scale is established with a protocol warning at headline weight: mean P100 latency spans 94.6–104.6 ms across four cohorts totalling 260 volunteers, and the spread tracks check size and equipment/protocol (the 26′ Indonesian cohort ~104 ms against 95–98 ms at 15′/60′ in Brazil and 32′ in India), so a P100 limit imported from another laboratory's protocol misclassifies; the sex pattern replicates — latency ~2–3 ms shorter and amplitude higher in women where sex-split values are printed. One record defect prints on its card: the 1989 record's female P100 dispersion ('± 49 msec') is implausible and is flagged, not reproduced as a figure. This pack carries the #7081 caveat on its face (see balance).

Stamped: 2026-11-28.

Evidence published: 1989–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the normative values for pattern-reversal visual evoked potentials (VEPs) — N75, P100 and N135 latencies and N75–P100 amplitude — how do they move with check size, sex and age, and what did 120 Indonesian, 59 Iranian, 54 Brazilian and 27 Indian volunteers give?

Balance of the evidence

4 reports, 260 healthy volunteers (120 + 54 + 59 + 27). Standing caveat, printed pack #7081 homes direct motor/sensory conduction velocity and amplitude in median, ulnar and sural nerves — this pack asks a different measurand that #7081 does not ask about, and the two packs cross-point. Developer ruling recorded as open. Distinct from pack #7251 (auditory brainstem response norms) and pack #7546 (optic nerve sheath diameter, a structural measure): this pack is the visual pathway's functional normative values. The 'visual evoked' pack hits in the library are therapy packs in multiple sclerosis (#3696, #6372) — no normative VEP question was homed.

MeSH: Adolescent · Adult · Aged · Cross-Sectional Studies · Evoked Potentials, Visual* · Female · Humans · Male · Middle Aged · Visual Acuity · Visual Cortex* · Visual Pathways · Young Adult · Evoked Potentials, Visual/physiology* · Healthy Volunteers · Photic Stimulation · Reference Values · Sex Factors · Vision, Binocular/physiology* · Vision, Monocular/physiology · Visual Acuity/physiology · Analysis of Variance · Iran · Reaction Time · Vision, Binocular/physiology · Visual Pathways/physiology* · India

Cards (5)

Card 1 — Indonesian norms (Ekayanti et al. 2021, Indian Journal of Ophthalmology — 120 healthy subjects, 26′ checkerboard, each eye alternately): mean P100 latency 104.6 ± 3.4 ms (left eye) and 104.1 ± 3.4 ms (right); amplitudes 9.8 ± 4.7 µV and 10.3 ± 5.4 µV

Study: Normative-data study (primary cohort report)

Population: 120 healthy subjects (60 men, 60 women) aged 18–65; VEP with a 26' checkerboard pattern, left and right eyes alternately.

Summary: Indonesian norms (Ekayanti et al. 2021, Indian Journal of Ophthalmology — 120 healthy subjects, 26′ checkerboard, each eye alternately): mean P100 latency 104.6 ± 3.4 ms (left eye) and 104.1 ± 3.4 ms (right); amplitudes 9.8 ± 4.7 µV and 10.3 ± 5.4 µV

Result: Mean P100 latency was 104.6 ± 3.4 ms (left eye) and 104.1 ± 3.4 ms (right eye), with amplitudes 9.8 ± 4.7 µV and 10.3 ± 5.4 µV. Sex and age did not significantly affect P100 latency; women had significantly higher P100 amplitude than men, and amplitude fell significantly with age. Height, weight, BMI, head circumference and visual acuity affected neither latency nor amplitude.

Watch out: The slowest P100 means on this pack (~104 ms) come from the largest cohort — the gap to the ~95–98 ms cohorts is protocol/check-size territory, not population pathology; this cohort's limits must not be applied to another laboratory's setup.

Source: Ekayanti MS et al. Normative values of visual evoked potential in adults. Indian journal of ophthalmology. 2021. PMID: 34427213. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Cross-Sectional Studies · Evoked Potentials, Visual* · Female · Humans · Male · Middle Aged · Visual Acuity · Visual Cortex* · Visual Pathways · Young Adult

Card 2 — Brazilian ISCEV-standard norms (Dotto et al. 2017, Documenta Ophthalmologica — 54 healthy adults): mean P100 latency for 15′ / 60′ checks 94.6 ± 4.7 / 96.1 ± 4.2 ms in women and 97.4 ± 4.9 / 97.7 ± 4.2 ms in men; 15′ amplitude larger in women (12.8 ± 5.7 µV) than men (8.6 ± 2.5 µV)

Study: Normative-data study (primary cohort report)

Population: 54 healthy adults (28 women; mean age 40.4 ± 13.7 years); ISCEV-standard pattern-reversal and flash VEPs under binocular and monocular stimulation.

Summary: Brazilian ISCEV-standard norms (Dotto et al. 2017, Documenta Ophthalmologica — 54 healthy adults): mean P100 latency for 15′ / 60′ checks 94.6 ± 4.7 / 96.1 ± 4.2 ms in women and 97.4 ± 4.9 / 97.7 ± 4.2 ms in men; 15′ amplitude larger in women (12.8 ± 5.7 µV) than men (8.6 ± 2.5 µV)

Result: Mean P100 latencies for 15' and 60' stimuli were 94.6 ± 4.7 ms and 96.1 ± 4.2 ms in women, and 97.4 ± 4.9 ms and 97.7 ± 4.2 ms in men. The 15' N75–P100 amplitude was larger in women (12.8 ± 5.7 µV) than men (8.6 ± 2.5 µV), with similar sex differences in flash-VEP amplitudes. The authors recommend gender-based normative values.

Watch out: The pack's protocol anchor (ISCEV standard): its check-size pair shows latency moving with stimulus size within one laboratory, which is the cleanest evidence on the pack that P100 limits are protocol-bound.

Source: Dotto PF et al. Gender-based normative values for pattern-reversal and flash visually evoked potentials under binocular and monocular stimulation in healthy adults. Documenta ophthalmologica. Advances in ophthalmology. 2017. PMID: 28560498. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Cross-Sectional Studies · Evoked Potentials, Visual/physiology* · Female · Healthy Volunteers · Humans · Male · Middle Aged · Photic Stimulation · Reference Values · Sex Factors · Vision, Binocular/physiology* · Vision, Monocular/physiology · Visual Acuity/physiology · Young Adult

Card 3 — Iranian norms (Mahjoob et al. 2019, Journal of Optometry — 59 healthy participants, 15′ and 60′ checks): viewing condition significantly affected N75–P100 amplitude and check size significantly affected N75, P100 and N135 latencies and amplitude — significance tests, not latency values

Study: Normative-data study (primary cohort report); figure-light at abstract level

Population: 59 healthy participants (mean age 22.55 ± 3.79 years); monocular and binocular pattern-reversal VEPs at 15 and 60 minutes of arc.

Summary: Iranian norms (Mahjoob et al. 2019, Journal of Optometry — 59 healthy participants, 15′ and 60′ checks): viewing condition significantly affected N75–P100 amplitude and check size significantly affected N75, P100 and N135 latencies and amplitude — significance tests, not latency values

Result: Viewing condition significantly affected N75–P100 amplitude (p < 0.001). Check size significantly affected the latencies of N75, P100 and N135, the N75–P100 amplitude, and the intraocular difference of P100 latency and amplitude. Amplitude differed significantly between sexes at both check sizes. The authors conclude each population needs its own normative values. This abstract prints significance tests, not the latency values themselves — no millisecond figure is printed from it.

Watch out: A young cohort (mean age ~22.6 years) whose abstract supports the determinants (check size, viewing condition, sex) but contributes no cardable latency figure; it is counted for structure, not values.

Source: Mahjoob M et al. Normative values of visual evoked potentials in Northeastern of Iran. Journal of optometry. 2019. PMID: 31028015. Registry ID: none in the record. MeSH: Adolescent · Adult · Analysis of Variance · Evoked Potentials, Visual/physiology* · Female · Humans · Iran · Male · Reaction Time · Reference Values · Vision, Binocular/physiology · Vision, Monocular/physiology · Visual Pathways/physiology* · Young Adult

Card 4 — Indian young-adult norms (Tandon & Sharma 1989, Indian Journal of Physiology and Pharmacology — 27 healthy adults aged 17–35, 32′ pattern reversal): P100 latency 95.37 ± 6.85 ms in men (amplitude 6.4 ± 2.38 µV) and 91.07 ms in women (amplitude 6.88 ± 2.79 µV) — the record's female dispersion is a defect and is not reproduced

Study: Normative-data study (primary cohort report); small cohort

Population: 27 healthy young adults (20 men, 7 women) aged 17–35; pattern-reversal VEP with 32' checks, 256 stimuli averaged.

Summary: Indian young-adult norms (Tandon & Sharma 1989, Indian Journal of Physiology and Pharmacology — 27 healthy adults aged 17–35, 32′ pattern reversal): P100 latency 95.37 ± 6.85 ms in men (amplitude 6.4 ± 2.38 µV) and 91.07 ms in women (amplitude 6.88 ± 2.79 µV) — the record's female dispersion is a defect and is not reproduced

Result: P100 latency was 95.37 +/- 6.85 ms in men with amplitude 6.4 +/- 2.38 µV, and 91.07 ms in women with amplitude 6.88 +/- 2.79 µV (female latency mean printed without its dispersion — see watchOut). The authors report the values are similar to age- and sex-matched Western subjects, indicating no ethnic variation in P100.

Watch out: RECORD DEFECT, flagged not reproduced: the record prints the female P100 latency as '91.07 +/- 49 msec' — a 49 ms standard deviation is implausible on its face (likely a typographical loss of a decimal point in the source), so the female mean prints without the dispersion and the '49' figure is not quoted as a standard deviation anywhere on this pack. Small N (27, only 7 women) and 1989 equipment.

Source: Tandon OP et al. Visual evoked potential in young adults: a normative study. Indian journal of physiology and pharmacology. 1989. PMID: 2620968. Registry ID: none in the record. MeSH: Adolescent · Adult · Evoked Potentials, Visual* · Female · Humans · India · Male · Reference Values

Card 5 — Synthesis — P100 norms are established per protocol, not per planet: check size moves the mean by ~10 ms, and the sex pattern is the most robust finding; the #7081 caveat stands on this pack

Study: Synthesis

Population: 4 cohorts, 260 healthy volunteers (120 Indonesian + 54 Brazilian + 59 Iranian + 27 Indian).

Summary: Synthesis — P100 norms are established per protocol, not per planet: check size moves the mean by ~10 ms, and the sex pattern is the most robust finding; the #7081 caveat stands on this pack

Result: Mean P100 latency spans 94.6–104.6 ms and the spread tracks check size and protocol: ~104 ms at 26′ (Indonesia), 94.6–97.7 ms at 15′/60′ (Brazil), 91.07–95.37 ms at 32′ (India, 1989). The sex pattern replicates across the cohorts that print it — latency ~2–3 ms shorter and amplitude higher in women — and amplitude falls with age in the largest cohort while latency does not. The stamp is PHYSIOLOGY — ESTABLISHED for the P100 scale read within its own protocol. One anchor (Iran) contributes determinants only, and one (India 1989) carries a flagged record defect in its female dispersion. Caveat restated: if the developer judges pack #7081 to have taken electrodiagnostic norms as a whole, this pack falls to cross-point status inside it.

Watch out: Importing a P100 upper limit across check sizes or equipment misclassifies healthy people; each cohort's values print with its check size attached, and no pooled 'normal P100' is printed.

Source: Synthesis of the reports carded above; no additional source.