SourceMed · Shelf #8561 in the ask interface
Oxygen uptake efficiency slope (OUES) and plateau (OUEP) reference values — 3 cohorts, 5,429 adults: age, sex and body size determine both; absolute OUES is substantially heterogeneous between nations
Shelf #8561 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — ESTABLISHED — the determinants of OUES are established across three cohorts totalling 5,429 adults (age, sex and body size in all three), with two honest limits at headline weight: two of the three abstracts withhold their numeric tables, so the only cardable numbers here are Sun et al.'s printed prediction equations, and no pooled 'normal OUES' is printed; and the Brazilian cohort's own international comparison found substantial heterogeneity in absolute OUES between national datasets, reduced but not abolished by body-surface-area normalisation, so the equations print as population-bound.
Stamped: 2026-11-28.
Evidence published: 2012–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what are the reference values for the oxygen uptake efficiency slope (OUES) and the related oxygen uptake efficiency plateau (OUEP) — what equations and distributions did 1,411 Belgian, 3,544 Brazilian and 474 US adults give, and how large is the international heterogeneity?
Balance of the evidence
3 reports, 5,429 healthy adults (1,411 Belgian cycle + 3,544 Brazilian treadmill + 474 US). Cycle and treadmill modes are never merged. Distinct from pack #7079 (FRIEND VO2peak percentiles — a maximal-effort measure) and pack #7157 (VE/VCO2 slope — the reciprocal ventilatory-efficiency framing): OUES is the submaximal VO2-versus-log-ventilation slope, usable without maximal effort. The paediatric OUES reference report (PMID 30354736) is homed on pack #8562 (paediatric CPET) — one home per report — and is cross-pointed there, not carded here.
MeSH: Adult · Age Factors · Bicycling · Body Surface Area · Cross-Sectional Studies · Exercise Test* · Female · Healthy Volunteers · Humans · Linear Models · Male · Middle Aged · Multivariate Analysis · Muscle Contraction* · Muscle Fatigue · Muscle, Skeletal/metabolism* · Oxygen Consumption* · Predictive Value of Tests · Reference Values · Reproducibility of Results · Sex Factors · Time Factors · White People* · Young Adult · Oxygen · Brazil · Adolescent · Aged · Aged, 80 and over · Anaerobic Threshold/physiology · Efficiency/physiology · Exercise/physiology · Exercise Test/methods,standards · Oxygen/metabolism,pharmacokinetics* · Oxygen Consumption/physiology* · Physical Fitness/physiology
Cards (4)
Card 1 — Belgian reference values (Buys et al. 2015, European Journal of Preventive Cardiology — 1,411 healthy adults aged 20–60, maximal cycle ergometry): age, sex and body surface area significant determinants; sex-specific prediction equations established and cross-validated — the abstract prints no OUES values
Study: Normative-data study (primary cohort report); figure-light at abstract level
Population: 1,411 healthy Caucasian adults (877 men; mean age 38.6 years, range 20–60) completing a maximal graded cycle exercise test.
Summary: Belgian reference values (Buys et al. 2015, European Journal of Preventive Cardiology — 1,411 healthy adults aged 20–60, maximal cycle ergometry): age, sex and body surface area significant determinants; sex-specific prediction equations established and cross-validated — the abstract prints no OUES values
Result: Multivariate regression revealed age, sex and body surface area as statistically significant determinants of the OUES. Sex-specific prediction equations were established and cross-validated, and reference values were described by age for each sex. The abstract prints the determinants and the equations' existence, not the OUES values themselves — no OUES number is printed from this anchor.
Watch out: A working-age (20–60), Caucasian, cycle-ergometry cohort: its equations do not cover older adults, other populations or treadmill testing, however comprehensive the internal cross-validation.
Source: Buys R et al. The oxygen uptake efficiency slope in 1411 Caucasian healthy men and women aged 20-60 years: reference values. European journal of preventive cardiology. 2015. PMID: 25147346. Registry ID: none in the record. MeSH: Adult · Age Factors · Bicycling · Body Surface Area · Cross-Sectional Studies · Exercise Test* · Female · Healthy Volunteers · Humans · Linear Models · Male · Middle Aged · Multivariate Analysis · Muscle Contraction* · Muscle Fatigue · Muscle, Skeletal/metabolism* · Oxygen Consumption* · Predictive Value of Tests · Reference Values · Reproducibility of Results · Sex Factors · Time Factors · White People* · Young Adult
Card 2 — Brazilian reference values and international comparison (Milani et al. 2023, Journal of Cardiopulmonary Rehabilitation and Prevention — 3,544 treadmill CPETs, ages 20–80): men higher than women on absolute, weight- and BSA-normalised OUES; values fell with ageing on a quadratic curve; substantial international heterogeneity in absolute OUES
Study: Normative-data study (primary cohort report); figure-light at abstract level
Population: 3,544 treadmill cardiopulmonary exercise tests in healthy Brazilian adults (1,970 men, 1,574 women) aged 20–80.
Summary: Brazilian reference values and international comparison (Milani et al. 2023, Journal of Cardiopulmonary Rehabilitation and Prevention — 3,544 treadmill CPETs, ages 20–80): men higher than women on absolute, weight- and BSA-normalised OUES; values fell with ageing on a quadratic curve; substantial international heterogeneity in absolute OUES
Result: Men had higher values than women for OUES, OUES/kg and OUES/BSA. Lower values were found with ageing and the data followed a quadratic regression curve. International comparisons of absolute OUES among Brazilian, European and Japanese data revealed substantial heterogeneity; the OUES/BSA measure minimised the discrepancies between Brazilian and European data. The abstract prints the pattern and the heterogeneity finding, not the reference tables.
Watch out: The heterogeneity finding is this card's headline: absolute OUES does not travel between national datasets, and BSA normalisation reduces rather than removes the gap. Treadmill mode — never merged with the cycle cohorts.
Source: Milani JGPO et al. Oxygen Uptake Efficiency Slope in South American Healthy Adults: COMPREHENSIVE REFERENCE VALUES AND INTERNATIONAL COMPARISONS. Journal of cardiopulmonary rehabilitation and prevention. 2023. PMID: 36862113. Registry ID: none in the record. MeSH: Male · Female · Humans · Adult · Reference Values · Cross-Sectional Studies · Oxygen Consumption* · Exercise Test* · Oxygen · Brazil
Card 3 — OUE plateau and slope equations (Sun, Hansen & Stringer 2012, European Journal of Applied Physiology — 474 healthy subjects aged 17–78; equations derived in 417): OUEP (mL/L) = 42.18 − 0.189 × years + 0.036 × cm (men) and 39.16 − 0.189 × years + 0.036 × cm (women); OUEP less variable than OUES (p < 0.0001)
Study: Normative-data / methods study (primary report) — the OUEP plateau is a variant measure of the same VO2/ventilation relationship, printed as a variant. TYPE note: typed 'Clinical Trial' at PubMed for a reference-values analysis; counted on substance
Population: 474 healthy subjects aged 17–78 (57 highly fit); prediction equations derived in 417 of them.
Summary: OUE plateau and slope equations (Sun, Hansen & Stringer 2012, European Journal of Applied Physiology — 474 healthy subjects aged 17–78; equations derived in 417): OUEP (mL/L) = 42.18 − 0.189 × years + 0.036 × cm (men) and 39.16 − 0.189 × years + 0.036 × cm (women); OUEP less variable than OUES (p < 0.0001)
Result: The printed equations are: for men, OUEP (mL/L) = 42.18 - 0.189 × years + 0.036 × cm and OUES [L/min/log(L/min)] = -0.610 - 0.032 × years + 0.023 × cm + 0.008 × kg; for women, OUEP (mL/L) = 39.16 - 0.189 × years + 0.036 × cm and OUES [L/min/log(L/min)] = -1.178 - 0.032 × years + 0.023 × cm + 0.008 × kg. The plateau measure (OUEP) and OUE at the anaerobic threshold were similar, highly reproducible and less variable than OUES (p < 0.0001), unaffected by study site or ergometer type, and extreme fitness had minimal effect on OUEP.
Watch out: VARIANT MEASURE: OUEP is the plateau of the same relationship, not the slope — its equations must not be used as OUES values. This is the only anchor printing cardable coefficients at abstract level, from 417 of its 474 subjects.
Source: Sun XG et al. Oxygen uptake efficiency plateau: physiology and reference values. European journal of applied physiology. 2012. PMID: 21695524. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Anaerobic Threshold/physiology · Efficiency/physiology · Exercise/physiology · Exercise Test/methods,standards · Female · Humans · Male · Middle Aged · Oxygen/metabolism,pharmacokinetics* · Oxygen Consumption/physiology* · Physical Fitness/physiology · Reference Values · Young Adult
Card 4 — Synthesis — OUES determinants are established and its absolute values are population-bound; only one anchor's equations are cardable, and no pooled normal OUES exists on this pack
Study: Synthesis
Population: 3 cohorts, 5,429 healthy adults (1,411 Belgian cycle + 3,544 Brazilian treadmill + 474 US).
Summary: Synthesis — OUES determinants are established and its absolute values are population-bound; only one anchor's equations are cardable, and no pooled normal OUES exists on this pack
Result: Age, sex and body size determine OUES in all three cohorts — that structure is established. The values are not pooled: two abstracts withhold their tables, the one printed equation set (Sun et al., derived in 417 subjects) prints as that cohort's, and the Brazilian cohort's international comparison found substantial heterogeneity in absolute OUES between Brazilian, European and Japanese data, minimised but not abolished by BSA normalisation. The OUEP plateau prints as a variant measure — similar to OUE at the anaerobic threshold, less variable than the slope, and independent of site and ergometer on its own record. The stamp is PHYSIOLOGY — ESTABLISHED for the determinants and the population-bound equations. Cross-point: the paediatric OUES report (PMID 30354736) is homed on pack #8562, not here.
Watch out: Applying one nation's OUES equation to another population misclassifies; mode (cycle vs treadmill) and normalisation (absolute, per kg, per BSA) must travel with any quoted value.
Source: Synthesis of the reports carded above; no additional source.