SourceMed · Shelf #8565 in the ask interface

Intussusception ultrasound accuracy — 3 syntheses with overlapping pools plus 1 paired primary: pooled sensitivity 0.96–0.98 / specificity 0.97–0.98, and POCUS 97.7% accurate against radiology US 99.3% for clinically important intussusception in 256 children

Shelf #8565 · Children’s health

PREDICTIVE PERFORMANCE — ultrasound detects intussusception in children at pooled sensitivity 0.96 (95% CI 0.95–0.97) / specificity 0.97 (0.97–0.98) in the 37-study pool and 0.98/0.98 in the 30-study pool (5,249 children), with no significant POCUS-vs-radiology difference in either synthesis; in the one paired primary, POCUS accuracy for clinically important intussusception was 97.7% against radiology ultrasound's 99.3% (difference 1.5 points, inside the 4-point noninferiority margin). The history and examination barely move the probability (positive likelihood ratios 1–2) — which is why the imaging question exists.

Stamped: 2026-11-28.

Evidence published: 2019–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children with suspected intussusception, how accurately does ultrasonography — point-of-care and radiology-performed — detect intussusception, and clinically important intussusception requiring reduction?

Balance of the evidence

3 syntheses with overlapping pools + 1 primary multicentre study, printed as such. The primary's target is narrower than the syntheses' (clinically important intussusception requiring reduction, not any intussusception) and the distinction prints. The 2022 synthesis is carded for its POCUS limb and its examination/radiograph counterweight limbs from the same record. No registry IDs in any record.

MeSH: Adolescent · Area Under Curve · Child · Child, Preschool · Emergency Service, Hospital/standards · Female · Humans · Infant · Infant, Newborn · Intussusception/diagnosis* · Male · Point-of-Care Systems/standards* · Predictive Value of Tests · Prospective Studies · Retrospective Studies · Ultrasonography/standards* · Clinical Competence · Emergency Medicine/standards* · Intussusception/diagnostic imaging*,therapy · Point-of-Care Testing/standards* · Diagnostic Imaging · Diagnostic Tests, Routine · Intussusception*/diagnostic imaging · Physical Examination · Sensitivity and Specificity · Ultrasonography

Cards (5)

Card 1 — Ultrasound synthesis (Rahmani 2023, Archives of Academic Emergency Medicine — 37 studies): pooled sensitivity 0.96 (95% CI 0.95–0.97) / specificity 0.97 (0.97–0.98), positive likelihood ratio 24.57, negative LR 0.05; no significant POCUS-vs-radiologist difference (P = 0.06). TYPE-FLAG: typed Review only at PubMed although a systematic review and meta-analysis on substance — counted on substance

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis) — TYPE-FLAG (typed 'Review' only at PubMed; a meta-analysis on substance)

Population: 37 studies of ultrasonography for intussusception in children, searched to 1 December 2022, quality assessed with QUADAS-2; the record prints no single pooled patient total for the 37 studies.

Summary: Ultrasound synthesis (Rahmani 2023, Archives of Academic Emergency Medicine — 37 studies): pooled sensitivity 0.96 (95% CI 0.95–0.97) / specificity 0.97 (0.97–0.98), positive likelihood ratio 24.57, negative LR 0.05; no significant POCUS-vs-radiologist difference (P = 0.06). TYPE-FLAG: typed Review only at PubMed although a systematic review and meta-analysis on substance — counted on substance

Result: Pooled sensitivity 0.96 (95% CI 0.95–0.97) and specificity 0.97 (0.97–0.98); pooled positive likelihood ratio 24.57 (8.26–73.03) and negative likelihood ratio 0.05 (0.04–0.08); area under the HSROC curve 0.989. Meta-regression showed no significant difference between point-of-care ultrasound and radiologist-performed ultrasound (p = 0.06; relative diagnostic odds ratio 4.38, 0.92–20.89).

Watch out: Its pool overlaps the 2019 pool carded below and the two are not independent confirmations; the POCUS-vs-radiology comparison is a between-study meta-regression, not a paired head-to-head — the paired evidence is the 2021 primary below.

Source: Rahmani E et al. Diagnostic Accuracy of Ultrasonography for Detection of Intussusception in Children; a Systematic Review and Meta-Analysis. Archives of academic emergency medicine. 2023. PMID: 36919137. Registry ID: none in the record. MeSH: none in the record

Card 2 — POCUS-vs-radiology synthesis (Tsou 2019, American Journal of Emergency Medicine — 30 studies / 5,249 children): sensitivity 0.98 (95% CI 0.96–0.98) / specificity 0.98 (0.95–0.99), LR+ 43.8, LR− 0.03, AUROC 0.99; meta-regression no significant POCUS-vs-RADUS difference (AUROC 0.95 vs 1.00, P = 0.128)

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 30 primary studies (n = 5,249 children) of ultrasound diagnostic accuracy for intussusception, searched to February 2018, reported to PRISMA-DTA.

Summary: POCUS-vs-radiology synthesis (Tsou 2019, American Journal of Emergency Medicine — 30 studies / 5,249 children): sensitivity 0.98 (95% CI 0.96–0.98) / specificity 0.98 (0.95–0.99), LR+ 43.8, LR− 0.03, AUROC 0.99; meta-regression no significant POCUS-vs-RADUS difference (AUROC 0.95 vs 1.00, P = 0.128)

Result: Ultrasonography sensitivity 0.98 (95% CI 0.96–0.98), specificity 0.98 (0.95–0.99), positive likelihood ratio 43.8 (18.0–106.7), negative likelihood ratio 0.03 (0.02–0.04), AUROC 0.99 (0.98–1.00). Meta-regression suggested no significant difference between POCUS and radiology-performed ultrasound (AUROC 0.95 vs 1.00, p = 0.128). The authors conclude POCUS has high diagnostic accuracy not significantly different from RADUS.

Watch out: Overlaps the 2023 pool; the near-perfect AUROC is a pooled figure across mostly retrospective primary studies and prints as a synthesis estimate, not as any single service's performance.

Source: Tsou PY et al. Accuracy of point-of-care ultrasound and radiology-performed ultrasound for intussusception: A systematic review and meta-analysis. The American journal of emergency medicine. 2019. PMID: 31182360. Registry ID: none in the record. MeSH: Adolescent · Area Under Curve · Child · Child, Preschool · Emergency Service, Hospital/standards · Female · Humans · Infant · Infant, Newborn · Intussusception/diagnosis* · Male · Point-of-Care Systems/standards* · Predictive Value of Tests · Prospective Studies · Retrospective Studies · Ultrasonography/standards*

Card 3 — Paired multicentre primary (Bergmann 2021, Annals of Emergency Medicine — 256 children at 17 sites, 58 (22.7%) with clinically important intussusception): POCUS accuracy 97.7% (95% CI 94.9–99.0) vs radiology US 99.3% (96.8–99.9), absolute difference 1.5 percentage points (−0.6 to 3.6) inside the 4-point noninferiority margin; POCUS sensitivity 96.6% / specificity 98.0%

Study: Primary multicentre noninferiority study (paired diagnostic tests)

Population: 256 children aged 3 months to 6 years in a convenience sample at 17 tertiary-care emergency departments across North and Central America, Europe and Australia; 35 experienced clinician sonologists; target condition was clinically important intussusception, defined as intussusception requiring radiographic or surgical reduction.

Summary: Paired multicentre primary (Bergmann 2021, Annals of Emergency Medicine — 256 children at 17 sites, 58 (22.7%) with clinically important intussusception): POCUS accuracy 97.7% (95% CI 94.9–99.0) vs radiology US 99.3% (96.8–99.9), absolute difference 1.5 percentage points (−0.6 to 3.6) inside the 4-point noninferiority margin; POCUS sensitivity 96.6% / specificity 98.0%

Result: POCUS identified 60 (23.4%) children with clinically important intussusception. Diagnostic accuracy was 97.7% (95% CI 94.9–99.0) for POCUS against 99.3% (96.8–99.9) for radiology ultrasound; the absolute difference was 1.5 percentage points (95% CI −0.6 to 3.6), inside the pre-set 4-percentage-point noninferiority margin. POCUS sensitivity was 96.6% (87.2–99.1) and specificity 98.0% (94.7–99.2). Agreement between POCUS and RADUS was high for trapped free fluid (83.3%, 40/48) and decreased colour Doppler signal (95.7%, 22/23).

Watch out: The row's only paired head-to-head, and its limits are the authors' own: convenience sampling and spectrum bias, experienced sonologists only, and a narrower target condition than the syntheses' — its accuracy pair does not transport to any-intussusception detection or to novice operators; the authors call for a larger randomised trial.

Source: Bergmann KR et al. Diagnostic Accuracy of Point-of-Care Ultrasound for Intussusception: A Multicenter, Noninferiority Study of Paired Diagnostic Tests. Annals of emergency medicine. 2021. PMID: 34226072. Registry ID: none in the record. MeSH: Child · Child, Preschool · Clinical Competence · Emergency Medicine/standards* · Female · Humans · Infant · Intussusception/diagnostic imaging*,therapy · Male · Point-of-Care Testing/standards* · Prospective Studies · Ultrasonography/standards*

Card 4 — Examination-and-imaging synthesis (Hom 2022, Pediatric Emergency Care — 13 primary studies): history/examination positive LRs 1–2 and negative LRs 0.4–0.8, abnormal abdominal radiograph LR+ 2.5 / LR− 0.20, POCUS LR+ 19.7 / LR− 0.10 (diagnostic odds ratio 213, labelled as such)

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 13 primary studies of children under 18 presenting to the emergency department with abdominal complaints consistent with intussusception, searched to June 2019, bias assessed with QUADAS-2.

Summary: Examination-and-imaging synthesis (Hom 2022, Pediatric Emergency Care — 13 primary studies): history/examination positive LRs 1–2 and negative LRs 0.4–0.8, abnormal abdominal radiograph LR+ 2.5 / LR− 0.20, POCUS LR+ 19.7 / LR− 0.10 (diagnostic odds ratio 213, labelled as such)

Result: Abdominal pain, vomiting and bloody stools had positive likelihood ratios between 1 and 2 and negative likelihood ratios between 0.4 and 0.8. An abnormal abdominal radiograph had LR+ 2.5 and LR− 0.20 (diagnostic odds ratio 13). Point-of-care ultrasound had LR+ 19.7 and LR− 0.10, with a diagnostic odds ratio of 213. The authors conclude history and physical examination had low diagnostic accuracy, radiographs low accuracy despite moderate discrimination, and POCUS the highest accuracy to rule in or rule out intussusception.

Watch out: Carded for its POCUS limb and as the row's honest counterweight: the clinical examination limbs (LRs ~1–2) show why imaging carries this diagnosis; its 13-study pool is small beside the two large ultrasound pools and overlaps them.

Source: Hom J et al. Evidence-Based Diagnostic Test Accuracy of History, Physical Examination, and Imaging for Intussusception: A Systematic Review and Meta-analysis. Pediatric emergency care. 2022. PMID: 32941364. Registry ID: none in the record. MeSH: Child · Diagnostic Imaging · Diagnostic Tests, Routine · Humans · Intussusception*/diagnostic imaging · Physical Examination · Sensitivity and Specificity · Ultrasonography

Card 5 — Synthesis — overlapping syntheses, one paired primary, a narrower target on the primary

Study: Synthesis

Population: 3 syntheses (37 studies; 30 studies / 5,249 children; 13 primary studies) with overlapping pools + 1 primary multicentre paired study (256 children, 17 sites). No report was refused; no additional primary was carded from inside the syntheses' pools (that would double-count).

Summary: Synthesis — overlapping syntheses, one paired primary, a narrower target on the primary

Result: Every slice agrees: ultrasound in children's intussusception is a 0.96–0.98 sensitive, 0.97–0.98 specific test, POCUS by experienced operators is noninferior to radiology ultrasound for clinically important disease in the one paired study, and the history, examination and plain radiograph are weak (LRs 1–2.5) beside it. The syntheses' target (any intussusception) and the primary's target (disease requiring reduction) are kept distinct on every card.

Watch out: Pooled near-perfection (AUROC 0.99) is a synthesis figure over mostly retrospective studies; the prospective paired figure — 97.7% vs 99.3% accuracy, with the authors' convenience-sampling caveat — is the transportable one.

Source: Synthesis of the reports carded above; no additional source.