Adnexal torsion imaging accuracy — 3 syntheses slicing one literature three ways (by sign, by modality, by age band): specificity is the strength (Doppler findings LR+ 11.0) while sensitivity never exceeds ~0.80 in any pool — preserved flow does not exclude torsion
Shelf #8567 · Women’s health
PREDICTIVE PERFORMANCE — every slice of this literature agrees on the asymmetry: specificity is the test's strength (ovarian Doppler findings specificity 95%, positive likelihood ratio 11.0; paediatric colour Doppler specificity 92.4%, LR+ 10.3) while sensitivity never exceeds ~0.80 in any pool (ultrasound by modality 0.79; colour Doppler in girls 78.6%; individual signs 53–69%) — so preserved Doppler flow does not exclude torsion, as the 2026 synthesis states in its own conclusion. No single sign composes a pair with any other, and the signs are never summed into a combined accuracy figure.
Stamped: 2026-11-28.
Evidence published: 2021–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In girls and women with suspected adnexal (ovarian) torsion, how accurately do ultrasound signs and imaging modalities — grey-scale, Doppler, CT and MRI — detect torsion against surgical findings?
Balance of the evidence
3 syntheses slicing one literature three ways — by individual sign, by modality, by age band — with heavily overlapping pools, printed as overlapping. The homed TWIST score pack #7929 is a clinical score for testicular torsion — a different organ, score and question, cross-point only. No registry IDs in any record.
MeSH: Female · Pregnancy · Humans · Ovarian Torsion · Torsion Abnormality/diagnostic imaging · Adnexal Diseases*/diagnostic imaging,surgery · Ovarian Diseases* · Edema · Magnetic Resonance Imaging · Ovarian Torsion/diagnostic imaging* · Sensitivity and Specificity · Tomography, X-Ray Computed · Ultrasonography
Cards (4)
Card 1 — Sign-by-sign synthesis (Garde 2023, Ultrasound in Obstetrics & Gynecology — 18 studies): ovarian oedema (8 studies, 809 patients) sensitivity 58% / specificity 86%, LR+ 4.0, LR− 0.49; adnexal mass (8, 1,044) 69%/46%, LR+ 1.3; whirlpool sign (6, 545) 65%/91%, LR+ 7.6, LR− 0.38; ovarian Doppler findings (14, 1,742) 53%/95%, LR+ 11.0, LR− 0.49; pelvic fluid (7, 981) 55%/69%; heterogeneity high for all analyses
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: 18 studies (1990–November 2021) of ultrasound signs for adnexal torsion against surgical findings as reference standard; per-sign study and patient counts as on the headline; study quality mostly moderate or good, with high risk of bias in the patient-selection and index-test domains in a significant proportion.
Summary: Sign-by-sign synthesis (Garde 2023, Ultrasound in Obstetrics & Gynecology — 18 studies): ovarian oedema (8 studies, 809 patients) sensitivity 58% / specificity 86%, LR+ 4.0, LR− 0.49; adnexal mass (8, 1,044) 69%/46%, LR+ 1.3; whirlpool sign (6, 545) 65%/91%, LR+ 7.6, LR− 0.38; ovarian Doppler findings (14, 1,742) 53%/95%, LR+ 11.0, LR− 0.49; pelvic fluid (7, 981) 55%/69%; heterogeneity high for all analyses
Result: Pooled sensitivity, specificity and positive/negative likelihood ratios by sign: ovarian oedema 58%, 86%, 4.0 and 0.49; adnexal mass 69%, 46%, 1.3 and 0.67; whirlpool sign 65%, 91%, 7.6 and 0.38; ovarian Doppler findings 53%, 95%, 11.0 and 0.49; pelvic fluid 55%, 69%, 1.7 and 0.66. The authors conclude an adnexal mass and pelvic fluid have poor diagnostic accuracy, while ovarian oedema, the whirlpool sign and decreased or absent Doppler flow have good specificity but only moderate sensitivity.
Watch out: Each sign is pooled separately and no combined sign-pair exists in this record — the signs must never be summed into a combined accuracy figure; heterogeneity was high for every analysis.
Source: Garde I et al. Diagnostic accuracy of ultrasound signs for detecting adnexal torsion: systematic review and meta-analysis. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2023. PMID: 35751902. Registry ID: none in the record. MeSH: Female · Pregnancy · Humans · Ovarian Torsion · Torsion Abnormality/diagnostic imaging · Adnexal Diseases*/diagnostic imaging,surgery · Ovarian Diseases* · Edema
Card 2 — Modality synthesis (Wattar 2021, BJOG — 18 studies / 1,654 women, 665 cases; 15 meta-analysed): ultrasound pooled sensitivity 0.79 (95% CI 0.63–0.92) / specificity 0.76 (0.54–0.93), LR+ 4.35, LR− 0.29 (12 studies, 1,187 women); ultrasound with Doppler 0.80/0.88 (7 studies, 845); MRI 0.81 (0.63–0.91) / 0.91 (0.80–0.96) (3 studies, 99 women); CT not meta-analysable (3 studies, 232 women; sensitivity range 0.74–0.95, specificity 0.80–0.90)
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: Female patients (paediatric and adult) with suspected adnexal torsion, imaging compared against surgical diagnosis and/or standard clinical/radiological follow-up to resolution of symptoms; searched to December 2019; QUADAS-2 assessed.
Summary: Modality synthesis (Wattar 2021, BJOG — 18 studies / 1,654 women, 665 cases; 15 meta-analysed): ultrasound pooled sensitivity 0.79 (95% CI 0.63–0.92) / specificity 0.76 (0.54–0.93), LR+ 4.35, LR− 0.29 (12 studies, 1,187 women); ultrasound with Doppler 0.80/0.88 (7 studies, 845); MRI 0.81 (0.63–0.91) / 0.91 (0.80–0.96) (3 studies, 99 women); CT not meta-analysable (3 studies, 232 women; sensitivity range 0.74–0.95, specificity 0.80–0.90)
Result: Ultrasound pooled sensitivity (12 studies, 1,187 women) was 0.79 (95% CI 0.63–0.92) and specificity 0.76 (0.54–0.93), with likelihood ratios LR− 0.29 (0.13–0.66) and LR+ 4.35 (2.03–9.32). Adding Doppler (7 studies, 845 women) yielded sensitivity 0.80 and specificity 0.88. MRI (3 studies, 99 women) pooled 0.81 (0.63–0.91) / 0.91 (0.80–0.96). A meta-analysis for CT was not possible (3 studies, 232 women; sensitivity range 0.74–0.95, specificity 0.80–0.90). The authors conclude ultrasound performs well as a first-line test and MRI could offer improved specificity, with more evidence needed.
Watch out: The modality intervals are wide (ultrasound specificity 0.54–0.93) and the MRI limb is 99 women in 3 studies — its 0.81/0.91 pair is the frailest figure on this pack and prints with its denominator.
Source: Wattar B et al. Accuracy of imaging modalities for adnexal torsion: a systematic review and meta-analysis. BJOG : an international journal of obstetrics and gynaecology. 2021. PMID: 32570294. Registry ID: none in the record. MeSH: Female · Humans · Magnetic Resonance Imaging · Ovarian Torsion/diagnostic imaging* · Sensitivity and Specificity · Tomography, X-Ray Computed · Ultrasonography
Card 3 — Paediatric synthesis (Alsabri 2026, International Journal of Emergency Medicine — girls 0–18, 13 studies / 10,457 patients): colour Doppler (10 studies, pooled N = 10,112) sensitivity 78.6% (95% CI 70.2–85.2) / specificity 92.4% (86.1–96.0), LR+ 10.3, LR− 0.23; grey-scale alone (5 studies, N = 345) 65.3%/88.7%; adolescent sensitivity lower than in younger children (71.4% vs 82.1%, P = 0.04). TYPE-FLAG: typed Review only at PubMed although a bivariate diagnostic meta-analysis on substance — counted on substance
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis) — TYPE-FLAG (typed 'Review' only at PubMed; a bivariate diagnostic meta-analysis on substance)
Population: 13 studies encompassing 10,457 paediatric patients (girls aged 0–18) presenting to emergency and acute care settings, searched through December 2025; QUADAS-2 and GRADE applied; certainty moderate for sensitivity and high for specificity.
Summary: Paediatric synthesis (Alsabri 2026, International Journal of Emergency Medicine — girls 0–18, 13 studies / 10,457 patients): colour Doppler (10 studies, pooled N = 10,112) sensitivity 78.6% (95% CI 70.2–85.2) / specificity 92.4% (86.1–96.0), LR+ 10.3, LR− 0.23; grey-scale alone (5 studies, N = 345) 65.3%/88.7%; adolescent sensitivity lower than in younger children (71.4% vs 82.1%, P = 0.04). TYPE-FLAG: typed Review only at PubMed although a bivariate diagnostic meta-analysis on substance — counted on substance
Result: For colour Doppler ultrasound (10 studies, pooled N = 10,112), pooled sensitivity was 78.6% (95% CI 70.2–85.2) and specificity 92.4% (86.1–96.0), LR+ 10.3 (6.1–17.4), LR− 0.23 (0.16–0.33), diagnostic odds ratio 43.7, HSROC area 0.924. Grey-scale alone (5 studies, N = 345) gave 65.3% / 88.7%. Specificity was higher in emergency-department studies (94.1% vs 88.9%, p = 0.03) and with prespecified thresholds (93.8% vs 85.2%, p = 0.02); sensitivity was lower in adolescents than younger children (71.4% vs 82.1%, p = 0.04). The authors conclude colour Doppler has high specificity, but moderate sensitivity means preserved Doppler flow does not reliably exclude torsion and a negative study should not delay surgical consultation when suspicion is high.
Watch out: One large pool dominates (10,112 of 10,457 patients in the colour-Doppler limb) while the grey-scale limb is only 345 patients — the two limbs' precision differs by an order of magnitude and prints as such.
Source: Alsabri M et al. Diagnostic accuracy of ultrasound for pediatric adnexal torsion: a systematic review and meta-analysis. International journal of emergency medicine. 2026. PMID: 41947044. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis — three slices of one literature, one agreed asymmetry
Study: Synthesis
Population: 3 syntheses (18 sign studies; 18 modality studies / 1,654 women; 13 paediatric studies / 10,457 patients) with heavily overlapping pools, slicing the same literature by sign, by modality and by age band. No primary was carded from inside a pool, and no sign combination was constructed.
Summary: Synthesis — three slices of one literature, one agreed asymmetry
Result: Specificity carries the test (Doppler findings 95% / LR+ 11.0; paediatric colour Doppler 92.4% / LR+ 10.3; whirlpool sign 91%) and sensitivity caps at ~0.80 everywhere (best pool: ultrasound-with-Doppler 0.80; weakest signs: Doppler findings alone 53%, pelvic fluid 55%). Grey-scale alone in girls (65.3%) and adolescents specifically (71.4% sensitive) are the weak limbs.
Watch out: The clinical consequence prints at full weight, in the newest synthesis's own words: preserved Doppler flow does not reliably exclude torsion, and a negative study should not delay surgical consultation when clinical suspicion is high.