SourceMed · Shelf #8568 in the ask interface

Transcranial Doppler for vasospasm after aneurysmal SAH — 3 syntheses answering two distinct questions: the 2001 angiography-referenced pool (MCA specificity 99%, sensitivity 67%) and the 2026 pool (76%/77%) disagree, unresolved; TCD vasospasm predicting delayed cerebral ischaemia pools at 90%/71%

Shelf #8568 · Critical care & sepsis

PREDICTIVE PERFORMANCE — the 2001 and 2026 pools disagree on middle cerebral artery specificity (99% vs 75–77%) and the disagreement prints unresolved: the 2001 pool is 317 angiography-paired tests from an earlier era with acknowledged possible data recycling, the 2026 pool is 3,594 patients across mixed thresholds and reference standards (sensitivity 76%, specificity 77%, AUC 0.82; Lindegaard-ratio subgroup 82%/88%). Against the different target of delayed cerebral ischaemia, TCD vasospasm pooled at sensitivity 90% / specificity 71% (PPV 57%, NPV 92%) — and no study in that pool reported functional outcome or mortality. The two target conditions are never merged.

Stamped: 2026-11-28.

Evidence published: 2001–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with aneurysmal subarachnoid haemorrhage, how accurately does transcranial Doppler detect cerebral vasospasm — against angiography, and as a predictor of delayed cerebral ischaemia — during monitoring?

Balance of the evidence

3 syntheses answering two related but distinct questions — detecting angiographic vasospasm (2001, 2026) and predicting delayed cerebral ischaemia (2016) — built as a monitoring row with both limbs labelled. Cross-points: pack #7508 (TCD normal velocities — the values question) and #6202 (cerebral autoregulation physiology); the vasospasm treatment packs are different questions. No registry IDs in the databank lists; the 2026 synthesis's PROSPERO registration CRD42024542692 is printed in its abstract and carried in its card body.

MeSH: Humans · Ultrasonography, Doppler, Transcranial*/methods,standards · Subarachnoid Hemorrhage*/complications,physiopathology · Vasospasm, Intracranial*/diagnosis,diagnostic imaging · Sensitivity and Specificity · ROC Curve · Brain Ischemia/diagnostic imaging*,mortality · Clinical Trials as Topic · Disability Evaluation · Prognosis · Safety · Survival Analysis · Treatment Outcome · Ultrasonography, Doppler, Transcranial* · Vasospasm, Intracranial/diagnostic imaging*,mortality · Blood Flow Velocity · Cerebral Angiography* · Cerebrovascular Circulation · Clinical Trials as Topic/statistics & numerical data · Predictive Value of Tests · Reproducibility of Results · Sample Size · Subarachnoid Hemorrhage/complications,diagnosis* · Vasospasm, Intracranial/diagnosis*,etiology

Cards (4)

Card 1 — Contemporary synthesis (Fujimoto 2026, Critical Care — 32 studies / 3,594 patients, middle cerebral artery focus): pooled sensitivity 76% (95% CI 70–81) / specificity 77% (68–84) for vasospasm, AUC 0.82, LR+ 3.4, LR− 0.3; MCA velocity subgroup (28 studies, 3,161) 76%/75%; Lindegaard ratio subgroup (7 studies, 1,162) 82%/88%; low-risk-of-bias studies (9, 1,223) 79%/82%. PROSPERO CRD42024542692, printed in the record

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 32 studies including 3,594 patients with aneurysmal subarachnoid haemorrhage, searched through 16 December 2025, quality assessed with QUADAS-2; the MCA is the vessel most frequently evaluated.

Summary: Contemporary synthesis (Fujimoto 2026, Critical Care — 32 studies / 3,594 patients, middle cerebral artery focus): pooled sensitivity 76% (95% CI 70–81) / specificity 77% (68–84) for vasospasm, AUC 0.82, LR+ 3.4, LR− 0.3; MCA velocity subgroup (28 studies, 3,161) 76%/75%; Lindegaard ratio subgroup (7 studies, 1,162) 82%/88%; low-risk-of-bias studies (9, 1,223) 79%/82%. PROSPERO CRD42024542692, printed in the record

Result: Pooled sensitivity and specificity were 76% (95% CI 70–81%) and 77% (68–84%) for cerebral vasospasm; area under the ROC curve 0.82; positive likelihood ratio 3.4 (2.8–4.7) and negative likelihood ratio 0.3 (0.24–0.40). Subgroups: MCA blood-flow velocity (28 studies, n = 3,161) 76% (69–81) / 75% (66–83); Lindegaard ratio (7 studies, n = 1,162) 82% (58–94) / 88% (64–97); low risk of bias (9 studies, n = 1,223) 79% (72–85) / 82% (66–91). The authors conclude TCD shows promising accuracy and may improve management within multimodal neuromonitoring. Registration printed in the record: PROSPERO CRD42024542692.

Watch out: Mixed velocity thresholds and reference standards across 32 studies are the likely engine of its specificity gap against the 2001 pool; the Lindegaard subgroup intervals are very wide (specificity 64–97%) on 7 studies.

Source: Fujimoto Y et al. Diagnostic accuracy of transcranial Doppler for cerebral vasospasm in aneurysmal subarachnoid hemorrhage: a systematic review and meta-analysis. Critical care (London, England). 2026. PMID: 41630057. Registry ID: none in the record. MeSH: Humans · Ultrasonography, Doppler, Transcranial*/methods,standards · Subarachnoid Hemorrhage*/complications,physiopathology · Vasospasm, Intracranial*/diagnosis,diagnostic imaging · Sensitivity and Specificity · ROC Curve

Card 2 — DCI-prediction synthesis (Kumar 2016, Journal of Neurosurgery — 17 studies / 2,870 patients): TCD vasospasm predicting delayed cerebral ischaemia at pooled sensitivity 90% (95% CI 77–96) / specificity 71% (51–84), PPV 57% (38–71), NPV 92% (83–96); heterogeneity I² > 50% for all syntheses; no study reported the impact of TCD vasospasm on functional outcome or mortality

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 17 studies (n = 2,870 patients) of TCD evidence of vasospasm as a predictor of delayed cerebral ischaemia after aneurysmal subarachnoid haemorrhage, searched through September 2014.

Summary: DCI-prediction synthesis (Kumar 2016, Journal of Neurosurgery — 17 studies / 2,870 patients): TCD vasospasm predicting delayed cerebral ischaemia at pooled sensitivity 90% (95% CI 77–96) / specificity 71% (51–84), PPV 57% (38–71), NPV 92% (83–96); heterogeneity I² > 50% for all syntheses; no study reported the impact of TCD vasospasm on functional outcome or mortality

Result: Pooled estimates for TCD diagnosis of vasospasm (for DCI) were sensitivity 90% (95% CI 77–96%), specificity 71% (51–84%), positive predictive value 57% (38–71%) and negative predictive value 92% (83–96%). The amount of variance attributable to heterogeneity was significant (I² > 50%) for all syntheses. No studies reported the impact of TCD evidence of vasospasm on functional outcome or mortality. The authors conclude TCD vasospasm is predictive of DCI with high accuracy, but is not a mandated standard of care because of the paucity of evidence on clinically relevant outcomes, and call for trials of TCD monitoring on patient-centred outcomes.

Watch out: A different target condition from the other two cards — predicting DCI, not detecting angiographic spasm — and it prints as such, never merged. Its empty outcome limb (no functional-outcome or mortality data in any study) is part of this pack's headline.

Source: Kumar G et al. Vasospasm on transcranial Doppler is predictive of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: a systematic review and meta-analysis. Journal of neurosurgery. 2016. PMID: 26495942. Registry ID: none in the record. MeSH: Brain Ischemia/diagnostic imaging*,mortality · Clinical Trials as Topic · Disability Evaluation · Humans · Prognosis · Safety · Survival Analysis · Treatment Outcome · Ultrasonography, Doppler, Transcranial* · Vasospasm, Intracranial/diagnostic imaging*,mortality

Card 3 — Angiography-referenced synthesis (Lysakowski 2001, Stroke — 26 reports comparing TCD with angiography, 7 meta-analysable): middle cerebral artery (5 trials, 317 tests) sensitivity 67% (95% CI 48–87) / specificity 99% (98–100), PPV 97%, NPV 78%; anterior cerebral artery (3 trials, 171 tests) 42%/76%; median validity score 4.5 of 10, and for 4 of the 7 trials data recycling could not be disproved

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 26 reports comparing transcranial Doppler with angiography in patients with vasospasm due to a ruptured cerebral aneurysm, searched through 31 January 2001; meta-analysis possible for 7 trials; three of the 7 reported on the same patients, each on another artery.

Summary: Angiography-referenced synthesis (Lysakowski 2001, Stroke — 26 reports comparing TCD with angiography, 7 meta-analysable): middle cerebral artery (5 trials, 317 tests) sensitivity 67% (95% CI 48–87) / specificity 99% (98–100), PPV 97%, NPV 78%; anterior cerebral artery (3 trials, 171 tests) 42%/76%; median validity score 4.5 of 10, and for 4 of the 7 trials data recycling could not be disproved

Result: For the middle cerebral artery (5 trials, 317 tests), sensitivity was 67% (95% CI 48–87%), specificity 99% (98–100%), PPV 97% (95–98%) and NPV 78% (65–91%). For the anterior cerebral artery (3 trials, 171 tests), sensitivity was 42% (11–72%), specificity 76% (53–100%), PPV 56% and NPV 69%. Median validity score was 4.5 (range 1–8) of 10, and for 4 of the 7 trials data recycling could not be disproved. The authors conclude that for the MCA, TCD is not likely to indicate spasm when angiography does not show one (high specificity) and may identify patients with spasm (high PPV), while for all other situations and arteries there is lack of evidence of accuracy or usefulness, most data are of low methodological quality, and bias cannot be ruled out.

Watch out: The specificity disagreement with 2026 prints unresolved at headline weight: this pool is 317 angiography-paired tests from an earlier scanner/threshold era, with low validity scores and possible data recycling the authors themselves flag — its 99% specificity is not averaged with the 2026 figure and does not overrule it.

Source: Lysakowski C et al. Transcranial Doppler versus angiography in patients with vasospasm due to a ruptured cerebral aneurysm: A systematic review. Stroke. 2001. PMID: 11588316. Registry ID: none in the record. MeSH: Blood Flow Velocity · Cerebral Angiography* · Cerebrovascular Circulation · Clinical Trials as Topic/statistics & numerical data · Humans · Predictive Value of Tests · Reproducibility of Results · Sample Size · Sensitivity and Specificity · Subarachnoid Hemorrhage/complications,diagnosis* · Ultrasonography, Doppler, Transcranial* · Vasospasm, Intracranial/diagnosis*,etiology

Card 4 — Synthesis — two target conditions, one unresolved specificity disagreement

Study: Synthesis

Population: 3 syntheses: angiographic-vasospasm detection in 2001 (7 meta-analysable trials; MCA limb 317 tests) and 2026 (32 studies / 3,594 patients), and DCI prediction in 2016 (17 studies / 2,870 patients). No primary was carded from inside a pool.

Summary: Synthesis — two target conditions, one unresolved specificity disagreement

Result: Sensitivity moved up across eras and targets (67% for MCA spasm in 2001; 76% in 2026; 90% for predicting DCI in 2016) while specificity moved down (99% → 77% for detection; 71% for prediction) — plausibly threshold, era and reference-standard drift, but the records do not adjudicate the cause, so the disagreement is printed, not explained away. The Lindegaard-ratio subgroup (82%/88%) is the 2026 pool's best limb on small numbers.

Watch out: Accuracy is not outcome benefit: the 2016 synthesis found no study linking TCD findings to functional outcome or mortality, and that absence prints on this pack's face beside every accuracy figure.

Source: Synthesis of the reports carded above; no additional source.