Pleural-fluid adenosine deaminase for tuberculous effusion — 3 overlapping syntheses, stable 0.92–0.93 / 0.90–0.92, largest pool 27,009 patients all at high risk of bias
Shelf #8575 · Lungs, breathing & sleep
PREDICTIVE PERFORMANCE — stable, rule-in-leaning, threshold-unresolved: pleural-fluid ADA pooled at sensitivity 0.92–0.93 / specificity 0.90–0.92 in every synthesis (largest: 174 publications / 27,009 patients, 0.92 / 0.90; at 40 ± 4 IU/L, 0.93 / 0.90), with likelihood ratios LR+ 9–12 and LR− 0.08–0.10 — but all included studies in the largest synthesis were at high risk of bias and it could draw no firm inference on the best threshold, so no cut-off is recommended here.
Stamped: 2026-11-28.
Evidence published: 2008–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with pleural effusion, how accurately does pleural-fluid adenosine deaminase diagnose tuberculous pleural effusion — overall, by assay technique, and across threshold bands around 40 IU/L?
Balance of the evidence
3 syntheses with overlapping pools: Liang 2008 (63 studies), Aggarwal 2019 (174 publications / 27,009 patients) and Palma 2019 (16 Spanish studies / 4,147 patients, a geographic slice). Estimates are unusually stable across 11 years; the bias verdict and the prevalence-transport warning (in low-prevalence settings ~90% specificity yields mostly false positives) print at the same weight. Accuracy only. No registry IDs in any record.
MeSH: Adenosine Deaminase/analysis* · Biomarkers/analysis · Clinical Enzyme Tests · Humans · Mycobacterium tuberculosis* · Odds Ratio · Pleural Effusion/enzymology* · ROC Curve · Sensitivity and Specificity · Tuberculosis, Pleural/diagnosis* · Animals · Female · Male · Pleural Effusion/diagnosis*,enzymology* · Tuberculosis, Pleural/pathology* · Clinical Enzyme Tests* · Likelihood Functions · Pleural Effusion/diagnosis* · Prospective Studies · Retrospective Studies · Spain
Cards (4)
Card 1 — Meta-analysis (Liang 2008, Respiratory Medicine — 63 studies): summary sensitivity 0.92 (95% CI 0.90–0.93) / specificity 0.90 (0.89–0.91), LR+ 9.03, LR− 0.10, diagnostic odds ratio 110.08 (likelihood ratios labelled as such)
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: 63 studies of pleural-fluid adenosine deaminase for tuberculous pleurisy. The abstract prints no total N — N not documented as a pooled total in this record.
Summary: Meta-analysis (Liang 2008, Respiratory Medicine — 63 studies): summary sensitivity 0.92 (95% CI 0.90–0.93) / specificity 0.90 (0.89–0.91), LR+ 9.03, LR− 0.10, diagnostic odds ratio 110.08 (likelihood ratios labelled as such)
Result: Summary sensitivity 0.92 (95% CI 0.90–0.93), specificity 0.90 (0.89–0.91), positive likelihood ratio 9.03 (7.19–11.35), negative likelihood ratio 0.10 (0.07–0.14) and diagnostic odds ratio 110.08 (69.96–173.20), as published.
Watch out: An early pool now nested inside the much larger 2019 synthesis — overlapping pools, never independent confirmations.
Source: Liang QL et al. Diagnostic accuracy of adenosine deaminase in tuberculous pleurisy: a meta-analysis. Respiratory medicine. 2008. PMID: 18222681. Registry ID: none in the record. MeSH: Adenosine Deaminase/analysis* · Biomarkers/analysis · Clinical Enzyme Tests · Humans · Mycobacterium tuberculosis* · Odds Ratio · Pleural Effusion/enzymology* · ROC Curve · Sensitivity and Specificity · Tuberculosis, Pleural/diagnosis*
Card 2 — Systematic review and meta-analysis (Aggarwal 2019, PLoS ONE — 174 publications / 27,009 patients; the largest synthesis): summary 0.92 (0.90–0.93) / 0.90 (0.88–0.91); at 40 ± 4 IU/L (65 studies) 0.93 (0.90–0.95) / 0.90 (0.87–0.91); at >65 IU/L (4 studies) 0.86 (0.61–0.96) / 0.94 (0.80–0.99); ALL included studies at high risk of bias, and no firm inference on the best threshold was possible
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: 174 publications with 27,009 patients with pleural effusion evaluated for tuberculous pleural effusion, as published.
Summary: Systematic review and meta-analysis (Aggarwal 2019, PLoS ONE — 174 publications / 27,009 patients; the largest synthesis): summary 0.92 (0.90–0.93) / 0.90 (0.88–0.91); at 40 ± 4 IU/L (65 studies) 0.93 (0.90–0.95) / 0.90 (0.87–0.91); at >65 IU/L (4 studies) 0.86 (0.61–0.96) / 0.94 (0.80–0.99); ALL included studies at high risk of bias, and no firm inference on the best threshold was possible
Result: Summary sensitivity 0.92 (95% CI 0.90–0.93), specificity 0.90 (0.88–0.91), diagnostic odds ratio 97.42 (74.90–126.72). By threshold band: 40 ± 4 IU/L (65 studies) 0.93 (0.90–0.95) / 0.90 (0.87–0.91); >65 IU/L (4 studies) 0.86 (0.61–0.96) / 0.94 (0.80–0.99). All included studies showed high risk of bias, as published.
Watch out: No threshold recommendation may be printed from this pack: the largest synthesis itself concludes no firm inference on the best threshold is possible, and every included study was at high risk of bias — that caps how far the stable estimates can be trusted.
Source: Aggarwal AN et al. Adenosine deaminase for diagnosis of tuberculous pleural effusion: A systematic review and meta-analysis. PloS one. 2019. PMID: 30913213. Registry ID: none in the record. MeSH: Adenosine Deaminase/analysis* · Animals · Female · Humans · Male · Pleural Effusion/diagnosis*,enzymology* · Tuberculosis, Pleural/pathology*
Card 3 — Meta-analysis of Spanish studies (Palma 2019, Archivos de Bronconeumología — 16 studies / 4,147 patients, 1,172 tuberculous effusions): sensitivity 93% / specificity 92%, LR+ 12, LR− 0.08, AUC 0.968; no accuracy differences by technique (Giusti, manual or automated kinetic) or cut-off; 73 non-Spanish studies trended lower (88% / 88%, not significant)
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis) — a geographic slice of the global pools, overlapping with them
Population: 4,147 patients in 16 Spanish studies, 1,172 with tuberculous pleural effusions, as published.
Summary: Meta-analysis of Spanish studies (Palma 2019, Archivos de Bronconeumología — 16 studies / 4,147 patients, 1,172 tuberculous effusions): sensitivity 93% / specificity 92%, LR+ 12, LR− 0.08, AUC 0.968; no accuracy differences by technique (Giusti, manual or automated kinetic) or cut-off; 73 non-Spanish studies trended lower (88% / 88%, not significant)
Result: Pleural-fluid ADA sensitivity 93%, specificity 92%, positive likelihood ratio 12, negative likelihood ratio 0.08 and area under the curve 0.968 for identifying tuberculosis. No differences in diagnostic accuracy between measurement techniques or selected cut-offs. In 73 non-Spanish studies sensitivity and specificity trended lower (88% / 88%) without reaching significance, as published.
Watch out: ADA is a rule-in-leaning test in high-TB-prevalence effusion populations (LR+ 9–12, LR− 0.08–0.10); in low-prevalence settings the same ~90% specificity yields mostly false positives — the pairs are prevalence-context-bound and do not transport unchanged.
Source: Palma RM et al. Diagnostic Accuracy of Pleural Fluid Adenosine Deaminase for Diagnosing Tuberculosis. Meta-analysis of Spanish Studies. Archivos de bronconeumologia. 2019. PMID: 30612601. Registry ID: none in the record. MeSH: Adenosine Deaminase/analysis* · Biomarkers/analysis · Clinical Enzyme Tests* · Humans · Likelihood Functions · Pleural Effusion/diagnosis* · Prospective Studies · Retrospective Studies · Sensitivity and Specificity · Spain · Tuberculosis, Pleural/diagnosis*
Card 4 — Synthesis — pleural-fluid ADA for tuberculous effusion: an unusually stable 0.92–0.93 / 0.90–0.92 across 11 years and 27,009 patients, on a base the largest synthesis rates entirely high risk of bias
Study: Synthesis
Population: 3 syntheses with overlapping pools: Liang 2008 (63 studies), Aggarwal 2019 (174 publications / 27,009 patients) and Palma 2019 (16 Spanish studies / 4,147 patients — a geographic slice of the global pools).
Summary: Synthesis — pleural-fluid ADA for tuberculous effusion: an unusually stable 0.92–0.93 / 0.90–0.92 across 11 years and 27,009 patients, on a base the largest synthesis rates entirely high risk of bias
Result: Every pool lands in the same narrow band: 0.92 / 0.90 (2008), 0.92 / 0.90 overall and 0.93 / 0.90 at the 40 ± 4 IU/L band (2019 global), 93% / 92% (2019 Spanish). Likelihood ratios are consistently rule-in-leaning (LR+ 9.03–12, LR− 0.08–0.10, labelled as likelihood ratios). No report was refused on this pack.
Watch out: Stability is not the same as trustworthiness: Aggarwal 2019 found all included studies at high risk of bias and could draw no firm threshold inference, so this pack prints no recommended cut-off.
Source: Synthesis of the reports carded above; no additional source.