Digital breast tomosynthesis — 3 overlapping syntheses: DBT 88% / 84% vs digital mammography 79% / 79% per examination, with no programme recall or false-positive improvement

Shelf #8577 · Women’s health

PREDICTIVE PERFORMANCE — more sensitive per examination, no programme false-positive gain: DBT alone pooled sensitivity 88% / specificity 84% vs digital mammography alone 79% / 79% in the 38-study DTA pool (488,099 patients), adding DM to DBT gave no additional benefit, and in dense breasts DBT sensitivity was 84–90% vs 69–86% — yet in the population-screening pool DBT did not improve recall, false-positive or false-negative rates, and the dense-breast recall benefit (relative rate 0.72, labelled relative) existed only retrospectively, not prospectively (1.12).

Stamped: 2026-11-28.

Evidence published: 2018–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In asymptomatic women attending breast screening, how accurately does digital breast tomosynthesis — alone, or combined with digital mammography — detect breast cancer compared with digital mammography alone, including in women with dense breasts?

Balance of the evidence

3 syntheses with overlapping pools: Alabousi 2020 (DTA pair), Phi 2018 (dense breasts; detection/recall rates) and Giampietro 2020 (population screening rates). The two frames print separately and never merge. Accuracy ≠ benefit fence: live #940 (TOSYMA/TMIST) is the programme-effectiveness question, cross-point only; no outcome claim leaks onto this face. No registry IDs in any record (PROSPERO CRD 42018111287 printed in the 2020 record).

MeSH: Breast Neoplasms/diagnosis* · Early Detection of Cancer/methods* · Female · Humans · Mammography/methods* · Reproducibility of Results · Breast Density* · Breast Neoplasms/diagnosis*,diagnostic imaging,pathology · Early Detection of Cancer · Mammography*/methods · Mass Screening · Odds Ratio · Publication Bias · Quality Assurance, Health Care · Breast Neoplasms/diagnosis,epidemiology* · Mammography/methods*,standards* · Sensitivity and Specificity

Cards (4)

Card 1 — Diagnostic test accuracy systematic review and meta-analysis (Alabousi 2020, European Radiology — 38 studies / 488,099 patients, 13,923 with breast cancer, average-risk women): DBT alone sensitivity 88% (83–92) / specificity 84% (76–89); DBT + digital mammography 88% (83–92) / 81% (73–88); digital mammography alone 79% (75–82) / 79% (71–85); sensitivity advantage persisted in meta-regression (P = 0.003–0.006); adding DM to DBT gave no additional benefit (P = 0.175–0.581); 11 studies at low risk of bias

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 488,099 average-risk women in 38 comparative studies (13,923 with breast cancer), as published. PROSPERO CRD 42018111287 is printed in the record.

Summary: Diagnostic test accuracy systematic review and meta-analysis (Alabousi 2020, European Radiology — 38 studies / 488,099 patients, 13,923 with breast cancer, average-risk women): DBT alone sensitivity 88% (83–92) / specificity 84% (76–89); DBT + digital mammography 88% (83–92) / 81% (73–88); digital mammography alone 79% (75–82) / 79% (71–85); sensitivity advantage persisted in meta-regression (P = 0.003–0.006); adding DM to DBT gave no additional benefit (P = 0.175–0.581); 11 studies at low risk of bias

Result: DBT alone sensitivity 88% (95% CI 83–92) / specificity 84% (76–89); combined DBT + DM 88% (83–92) / 81% (73–88); DM alone 79% (75–82) / 79% (71–85). The greater sensitivity of DBT with or without DM was preserved in meta-regression (P = 0.003–0.006); no significant difference between DBT alone and DBT + DM (P = 0.175–0.581), as published.

Watch out: Specificity intervals are wide (76–89% for DBT) and the pair averages mixed screening/diagnostic spectra within the included comparative studies, as the record describes them. The record's own conclusion notes specificity of DBT was no different from DM — the gain is sensitivity.

Source: Alabousi M et al. Digital breast tomosynthesis for breast cancer detection: a diagnostic test accuracy systematic review and meta-analysis. European radiology. 2020. PMID: 31900699. Registry ID: none in the record. MeSH: Breast Neoplasms/diagnosis* · Early Detection of Cancer/methods* · Female · Humans · Mammography/methods* · Reproducibility of Results

Card 2 — Systematic review and meta-analysis in dense breasts (Phi 2018, BMC Cancer — 16 studies, 11 screening and 5 diagnostic): in diagnosis DBT sensitivity 84–90% vs DM 69–86% with no specificity gain; in screening DBT + DM raised cancer detection rate vs DM alone (relative rate 1.33 (1.20–1.47) retrospective, 1.52 (1.08–2.11) prospective — labelled relative); recall rate fell retrospectively (relative rate 0.72 (0.64–0.80)) but not in the two prospective studies (1.12 (0.76–1.63))

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: Women with mammographically dense breasts in 16 studies (11 screening, 5 diagnostic), as published.

Summary: Systematic review and meta-analysis in dense breasts (Phi 2018, BMC Cancer — 16 studies, 11 screening and 5 diagnostic): in diagnosis DBT sensitivity 84–90% vs DM 69–86% with no specificity gain; in screening DBT + DM raised cancer detection rate vs DM alone (relative rate 1.33 (1.20–1.47) retrospective, 1.52 (1.08–2.11) prospective — labelled relative); recall rate fell retrospectively (relative rate 0.72 (0.64–0.80)) but not in the two prospective studies (1.12 (0.76–1.63))

Result: In diagnosis, DBT increased sensitivity (84–90%) versus DM alone (69–86%) but not specificity; DBT improved cancer detection rate versus DM (relative rate 1.16, 95% CI 1.02–1.31 as printed in the record). In screening, DBT + DM increased detection (relative rate 1.33 retrospective; 1.52 prospective). Recall fell in retrospective studies (relative rate 0.72) but not prospectively (1.12), as published. All relative rates are labelled relative.

Watch out: The dense-breast recall benefit exists only in retrospective studies and vanishes prospectively (relative rate 1.12, interval 0.76–1.63) — that split prints at headline weight. Detection and recall rates are programme rates, not a sensitivity/specificity pair, and never merge with the 2020 DTA pair.

Source: Phi XA et al. Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts - a systematic review and meta-analysis. BMC cancer. 2018. PMID: 29615072. Registry ID: none in the record. MeSH: Breast Density* · Breast Neoplasms/diagnosis*,diagnostic imaging,pathology · Early Detection of Cancer · Female · Humans · Mammography*/methods · Mass Screening · Odds Ratio · Publication Bias · Quality Assurance, Health Care

Card 3 — Systematic review and meta-analysis for population-based screening (Giampietro 2020, Scientific Reports): per 1,000 screens DBT + digital mammography increased overall cancer detection by 3 and invasive cancer by 2 (relative rate 1.36 (1.18–1.58) and 1.51 (1.27–1.79) — labelled relative), DBT + synthetic mammography by 2 and 2 (1.38 and 1.37); DBT did NOT improve recall, false-positive or false-negative rates; low quality of evidence due to heterogeneity

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: Women attending population-based breast cancer screenings in controlled studies comparing DBT with digital mammography. The abstract prints no single total N — N not documented as a pooled total in this record.

Summary: Systematic review and meta-analysis for population-based screening (Giampietro 2020, Scientific Reports): per 1,000 screens DBT + digital mammography increased overall cancer detection by 3 and invasive cancer by 2 (relative rate 1.36 (1.18–1.58) and 1.51 (1.27–1.79) — labelled relative), DBT + synthetic mammography by 2 and 2 (1.38 and 1.37); DBT did NOT improve recall, false-positive or false-negative rates; low quality of evidence due to heterogeneity

Result: Per 1,000 screens, DBT plus digital mammography increased overall and invasive cancer detection rates by 3 and 2 (relative rates 1.36 and 1.51); DBT plus synthetic mammography by 2 and 2 (relative rates 1.38 and 1.37). DBT did not improve recall, false-positive or false-negative rates. Quality of evidence was low due to heterogeneity (moderate for the detection rates as the record grades them), as published. All relative rates are labelled relative.

Watch out: The tension is real and prints: DBT is more sensitive per examination, yet programme-level false-positive and recall rates did not improve in this population pool. Detection-rate gains are not a mortality claim.

Source: Giampietro RR et al. Accuracy and Effectiveness of Mammography versus Mammography and Tomosynthesis for Population-Based Breast Cancer Screening: A Systematic Review and Meta-Analysis. Scientific reports. 2020. PMID: 32409756. Registry ID: none in the record. MeSH: Breast Neoplasms/diagnosis,epidemiology* · Early Detection of Cancer · Female · Humans · Mammography/methods*,standards* · Mass Screening · Publication Bias · Reproducibility of Results · Sensitivity and Specificity

Card 4 — Synthesis — digital breast tomosynthesis: +9 points of sensitivity over digital mammography in the DTA pool (88% vs 79%), no added benefit from combining DM, and no programme-level recall or false-positive improvement

Study: Synthesis

Population: 3 syntheses with overlapping pools: Alabousi 2020 (38 studies / 488,099 patients, the accuracy pair), Phi 2018 (16 dense-breast studies, detection/recall rates) and Giampietro 2020 (population screening, detection/recall rates). The two accuracy frames — per-examination pairs vs programme rates — are never merged.

Summary: Synthesis — digital breast tomosynthesis: +9 points of sensitivity over digital mammography in the DTA pool (88% vs 79%), no added benefit from combining DM, and no programme-level recall or false-positive improvement

Result: DBT alone 88% / 84%, DBT + DM 88% / 81%, DM alone 79% / 79% (2020 DTA pool). Dense breasts: DBT sensitivity 84–90% vs DM 69–86% in diagnosis, detection relative rate 1.33–1.52 in screening, recall benefit retrospective only. Population screening: +3 overall and +2 invasive cancers per 1,000 screens for DBT + DM, with no improvement in recall, false-positive or false-negative rates. No report was refused; live #940 (TOSYMA/TMIST) asks the programme-effectiveness question within two trial programmes — a different question, cross-point only, per the accuracy ≠ benefit fence.

Watch out: Accuracy is not benefit: nothing on this pack shows DBT screening reduces mortality or advanced cancer. Specificity intervals in the DTA pool are wide (76–89%).

Source: Synthesis of the reports carded above; no additional source.