SourceMed · Shelf #8595 in the ask interface

Exercise electrocardiogram accuracy for coronary artery disease — 3 syntheses, 1989–2012: mean sensitivity 68% / specificity 77% with ranges 23–100% / 17–100%, women sensitivity 0.61 / specificity 0.70, no modern pooled pair

Shelf #8595 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — modest and highly variable: across 147 reports the exercise ECG's mean sensitivity was 68% and mean specificity 77%, but with ranges of 23–100% and 17–100% that make the centre a description of a literature, not a property of the test; in women the pooled pair was lower (0.61 / 0.70, LR+ 2.25); the prospective no-known-CAD pool prints likelihood ratios only (treadmill ECG LR+ 3.57 / LR− 0.38) — no modern pooled pair exists and none is manufactured here

Stamped: 2026-11-28.

Evidence published: 1989–2012.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients without known coronary artery disease undergoing exercise testing against coronary angiography, how accurate is the exercise electrocardiogram (ST depression) — overall, by exercise modality, and in women?

Balance of the evidence

3 syntheses spanning 1989–2012 with overlapping primary pools; no primary reports and no modern pooled pair. One TYPE-FLAG (Gianrossi 1989 typed Review only, a meta-analysis on substance, counted on substance). Likelihood ratios are labelled as such wherever printed; the women-only and modality limbs print separately, never merged into a single pair. Work-up bias in the angiography-referred primaries is the family's standing caveat.

MeSH: Coronary Disease/diagnosis* · Electrocardiography* · Exercise Test* · Humans · Meta-Analysis as Topic* · Regression Analysis · Sensitivity and Specificity · Statistics as Topic · Coronary Angiography · Coronary Disease/diagnosis*,diagnostic imaging · Echocardiography · Electrocardiography · Female · Likelihood Functions · Middle Aged · Physical Exertion/physiology · Predictive Value of Tests · ROC Curve · Radionuclide Imaging · Radiopharmaceuticals · Thallium Radioisotopes · Aged · Coronary Artery Disease/diagnosis* · Echocardiography, Stress/methods · Exercise Test/standards* · Male · Myocardial Perfusion Imaging/methods · Prospective Studies

Cards (4)

Card 1 — Founding pool (Gianrossi 1989, Circulation — meta-analysis of 147 consecutively published reports / 24,074 patients): mean sensitivity 68% (range 23–100%, SD 16%) and mean specificity 77% (range 17–100%, SD 17%) — the variability itself is the finding — TYPE-FLAG: typed Review only at PubMed, a meta-analysis on substance

Study: Meta-analysis (synthesis, counted as a synthesis) — TYPE-FLAG: the record is typed Journal Article / Review only although a meta-analysis on substance; counted on substance

Population: 147 consecutively published reports involving 24,074 patients who underwent both exercise ECG (exercise-induced ST depression) and coronary angiography.

Summary: Founding pool (Gianrossi 1989, Circulation — meta-analysis of 147 consecutively published reports / 24,074 patients): mean sensitivity 68% (range 23–100%, SD 16%) and mean specificity 77% (range 17–100%, SD 17%) — the variability itself is the finding — TYPE-FLAG: typed Review only at PubMed, a meta-analysis on substance

Result: Wide variability in sensitivity and specificity was found (mean sensitivity 68%, range 23–100%, SD 16%; mean specificity 77%, range 17–100%, SD 17%). Four study characteristics were significantly and independently related to sensitivity (treatment of equivocal results, comparison with a 'better' test such as thallium scintigraphy, exclusion of patients on digitalis, publication year) and four to specificity. Stepwise linear regression explained less than 35% of the variance in the reported sensitivities and specificities.

Watch out: A mean of 68% / 77% over ranges of 23–100% and 17–100% is a description of a literature, not a property of the test — the pack prints the ranges at the same weight as the means. Angiography-referred primaries carry work-up (verification) bias, the standing caveat of this whole family.

Source: Gianrossi R et al. Exercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis. Circulation. 1989. PMID: 2661056. Registry ID: none in the record. MeSH: Coronary Disease/diagnosis* · Electrocardiography* · Exercise Test* · Humans · Meta-Analysis as Topic* · Regression Analysis · Sensitivity and Specificity · Statistics as Topic

Card 2 — Women-only pool (Kwok 1999, American Journal of Cardiology — meta-analysis in women, 19 exercise-ECG studies): exercise ECG weighted sensitivity 0.61 (95% CI 0.54–0.68) / specificity 0.70 (0.64–0.75), LR+ 2.25, LR− 0.55

Study: Meta-analysis (synthesis, counted as a synthesis — exercise-ECG limb only)

Population: Women who underwent both an exercise test and coronary angiography: 19 studies for exercise electrocardiography, 5 for exercise thallium and 3 for exercise echo (studies required data on at least 50 women); only the exercise-ECG limb is counted here.

Summary: Women-only pool (Kwok 1999, American Journal of Cardiology — meta-analysis in women, 19 exercise-ECG studies): exercise ECG weighted sensitivity 0.61 (95% CI 0.54–0.68) / specificity 0.70 (0.64–0.75), LR+ 2.25, LR− 0.55

Result: Exercise ECG weighted mean sensitivity 0.61 (95% CI 0.54–0.68), specificity 0.70 (0.64–0.75), positive likelihood ratio (labelled as such) 2.25 (1.84–2.66) and negative likelihood ratio 0.55 (0.47–0.62). The same pool's exercise-thallium (0.78 / 0.64) and exercise-echo (0.86 / 0.79) limbs are cross-points to the stress-echocardiography and perfusion packs, not counted here. The authors concluded the available exercise tests were only moderately sensitive and specific in women.

Watch out: The women-only pool sits below the all-comers mean on both limbs (0.61 / 0.70 vs 68% / 77%) — a spectrum finding, printed, not adjusted away. Likelihood ratios are labelled as such wherever printed on this pack.

Source: Kwok Y et al. Meta-analysis of exercise testing to detect coronary artery disease in women. The American journal of cardiology. 1999. PMID: 10080415. Registry ID: none in the record. MeSH: Coronary Angiography · Coronary Disease/diagnosis*,diagnostic imaging · Echocardiography · Electrocardiography · Exercise Test* · Female · Humans · Likelihood Functions · Middle Aged · Physical Exertion/physiology · Predictive Value of Tests · ROC Curve · Radionuclide Imaging · Radiopharmaceuticals · Sensitivity and Specificity · Thallium Radioisotopes

Card 3 — Prospective, no-known-CAD pool (Banerjee 2012, International Journal of Clinical Practice — systematic review and meta-analysis of prospective studies in patients without known CAD, 34 studies / 3,352 participants across five exercise modalities): the abstract prints likelihood ratios, not a pooled ECG pair — treadmill ECG LR+ 3.57 / LR− 0.38

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis — likelihood-ratio limb only)

Population: 34 prospective studies, 3,352 participants without known coronary artery disease, comparing exercise stress testing with coronary angiography across five modalities (treadmill ECG, treadmill echo, bicycle ECG, bicycle echo, myocardial perfusion imaging); CAD prevalence across studies ranged 12–83%.

Summary: Prospective, no-known-CAD pool (Banerjee 2012, International Journal of Clinical Practice — systematic review and meta-analysis of prospective studies in patients without known CAD, 34 studies / 3,352 participants across five exercise modalities): the abstract prints likelihood ratios, not a pooled ECG pair — treadmill ECG LR+ 3.57 / LR− 0.38

Result: The record prints likelihood ratios (labelled as such), not a pooled sensitivity/specificity pair for the ECG: treadmill ECG LR+ 3.57 / LR− 0.38; treadmill echo LR+ 7.94 / LR− 0.19; bicycle echo LR+ 11.34. A positive test was more helpful in younger patients (LR+ 4.74) than older patients (LR+ 2.8). Positive and negative likelihood ratios increased in low-prevalence settings. No sensitivity/specificity pair may be printed from this anchor.

Watch out: The echo and perfusion limbs of this pool are cross-points to the stress-echocardiography and perfusion packs. A prevalence range of 12–83% across primaries means the likelihood ratios travel with the setting that produced them.

Source: Banerjee A et al. Diagnostic accuracy of exercise stress testing for coronary artery disease: a systematic review and meta-analysis of prospective studies. International journal of clinical practice. 2012. PMID: 22512607. Registry ID: none in the record. MeSH: Aged · Coronary Angiography · Coronary Artery Disease/diagnosis* · Echocardiography, Stress/methods · Electrocardiography · Exercise Test/standards* · Female · Humans · Male · Middle Aged · Myocardial Perfusion Imaging/methods · Prospective Studies · Sensitivity and Specificity

Card 4 — Synthesis — 3 syntheses spanning 1989–2012 with overlapping primary pools: there is no modern pooled pair for the exercise ECG, and this pack does not manufacture one

Study: Synthesis

Population: 3 syntheses: Gianrossi 1989 (147 reports / 24,074 patients; TYPE-FLAG — typed Review only, a meta-analysis on substance), Kwok 1999 (19 exercise-ECG studies in women), Banerjee 2012 (34 prospective studies / 3,352 participants without known CAD, likelihood ratios only). The primary pools overlap across the three.

Summary: Synthesis — 3 syntheses spanning 1989–2012 with overlapping primary pools: there is no modern pooled pair for the exercise ECG, and this pack does not manufacture one

Result: The honest summary is a mean sensitivity of 68% and specificity of 77% (Gianrossi) with ranges so wide (sensitivity 23–100%, specificity 17–100%) that the pooled centre describes a literature rather than a test property; the women-only pool sits lower (0.61 / 0.70, LR+ 2.25 / LR− 0.55); and the prospective no-known-CAD pool expresses performance as likelihood ratios (treadmill ECG LR+ 3.57 / LR− 0.38), with a positive test more helpful in younger (LR+ 4.74) than older patients (LR+ 2.8). Cross-points: Kwok's exercise-thallium and exercise-echo limbs belong with the perfusion and stress-echocardiography packs; Banerjee's echo and perfusion limbs likewise.

Watch out: Work-up (verification) bias in angiography-referred primaries is the standing caveat of this whole family and prints here: patients reach the reference standard because of their test results and symptoms, which inflates sensitivity and deflates specificity relative to an unselected population. Likelihood ratios are labelled as such throughout.

Source: Synthesis of the reports carded above; no additional source.