SourceMed · Shelf #8606 in the ask interface
FRAX fracture-risk prediction performance — 2 syntheses + 2 primary validations: hip-fracture AUC 0.81–0.84 with good hip calibration but consistent underestimation of major osteoporotic fractures, and a near-chance male limb (AUC 0.54–0.57) in the small Australian validation
Shelf #8606 · Bones & joints
PREDICTIVE PERFORMANCE — FRAX discriminates hip fracture moderately well (AUC 0.81 with BMD in the adjusted synthesis; 0.841 in the large Belgian cohort) and calibrates well for hip fracture, but consistently underestimates major osteoporotic fractures (calibration slope 2.12) with lower discrimination for that outcome (0.708–0.77), and the small Australian validation found near-chance discrimination in men (AUC 0.54–0.57). There is no single FRAX AUC — performance is outcome-bound and sex-bound. Base: 2 syntheses + 2 primary validations.
Stamped: 2026-11-28.
Evidence published: 2010–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In older adults, how well does the FRAX fracture risk tool predict 10-year hip and major osteoporotic fracture — discrimination (AUC) and calibration — with and without bone mineral density, and how does it compare with the Garvan and QFracture tools?
Balance of the evidence
4 reports: 2 syntheses (45 and 53 validation studies across 13–14 tools, with heavily overlapping primary pools — one literature read twice, never two independent confirmations) + 2 primary external validations (n=3,560 women; n=200 retrospectively sampled). The Marques synthesis prints no FRAX-specific pooled AUC and none is taken from it. Calibration and discrimination split on this pack and are never merged: the hip AUC may not be borrowed to vouch for the major-fracture probability. Cross-point only: live pack #797 asks whether FRAX-based community screening reduces fractures (SCOOP/ROSE) — a strategy question whose outcomes are not borrowed here.
MeSH: Absorptiometry, Photon · Area Under Curve · Decision Support Techniques* · Female · Humans · Male · Osteoporosis/complications,diagnostic imaging* · Osteoporotic Fractures/epidemiology*,etiology · ROC Curve · Risk Assessment/methods · Risk Factors · Sex Factors · Bone Density/physiology · Hip Fractures/etiology,physiopathology · Osteoporosis/complications,physiopathology · Osteoporotic Fractures/etiology*,physiopathology · Predictive Value of Tests · Validation Studies as Topic · Aged · Aged, 80 and over · Algorithms* · Bone Density · Epidemiologic Methods · Middle Aged · Nomograms · Osteoporotic Fractures/diagnosis*,physiopathology · Prognosis
Cards (5)
Card 1 — Tool census synthesis (Marques 2015, Annals of the Rheumatic Diseases — systematic review and meta-analysis, 45 studies / 13 tools): only FRAX (26 studies, 9 countries), Garvan (6) and QFracture (3) had repeated population-based external validation; overall tool accuracy was satisfactory (>0.70 AUC), QFracture reaching 0.89 (95% CI 0.88–0.89) — the abstract prints NO FRAX-specific pooled AUC, and none is printed from this card
Study: Systematic review and meta-analysis (synthesis)
Population: 45 studies of 13 fracture risk prediction tools; 20 studies of FRAX, Garvan and QFracture entered 17 meta-analyses (for hip or major osteoporotic fractures; men or women; with or without bone mineral density).
Summary: Tool census synthesis (Marques 2015, Annals of the Rheumatic Diseases — systematic review and meta-analysis, 45 studies / 13 tools): only FRAX (26 studies, 9 countries), Garvan (6) and QFracture (3) had repeated population-based external validation; overall tool accuracy was satisfactory (>0.70 AUC), QFracture reaching 0.89 (95% CI 0.88–0.89) — the abstract prints NO FRAX-specific pooled AUC, and none is printed from this card
Result: Only three tools had been tested more than once in a population-based setting: FRAX (26 studies in 9 countries), Garvan (6 studies in 3 countries) and QFracture (3 studies in the UK, 1 also including Irish participants). The overall accuracy of the different tools is satisfactory (>0.70), with QFracture reaching 0.89 (95% CI 0.88 to 0.89). Significant methodological limitations were observed in many studies, suggesting caution when comparing tools based solely on the AUC.
Watch out: No FRAX-specific pooled AUC appears in this record's abstract and none may be printed from it — this card establishes the validation census (FRAX is the most externally validated tool), not a FRAX number.
Source: Marques A et al. The accuracy of osteoporotic fracture risk prediction tools: a systematic review and meta-analysis. Annals of the rheumatic diseases. 2015. PMID: 26248637. Registry ID: none in the record. MeSH: Absorptiometry, Photon · Area Under Curve · Decision Support Techniques* · Female · Humans · Male · Osteoporosis/complications,diagnostic imaging* · Osteoporotic Fractures/epidemiology*,etiology · ROC Curve · Risk Assessment/methods · Risk Factors · Sex Factors
Card 2 — Adjusted synthesis (Beaudoin 2019, Osteoporosis International — systematic review, meta-analysis and meta-regression, 53 validation studies / 14 tools): unadjusted, QFracture had the best hip-fracture discrimination (AUC 0.88); adjusted, FRAX with BMD (0.81) and Garvan with BMD (0.79) were highest for hip fracture; for major osteoporotic fracture QFracture led (0.77); FRAX with BMD beat FRAX without for osteoporotic/any fracture (0.72 vs 0.69); substantial heterogeneity throughout
Study: Systematic review and meta-analysis (synthesis)
Population: 53 validation studies assessing the discriminative ability of 14 tools in populations independent of their derivation cohorts; only FRAX, Garvan and QFracture had enough studies for meta-regression comparison, adjusted for gender, mean age, age range and study quality.
Summary: Adjusted synthesis (Beaudoin 2019, Osteoporosis International — systematic review, meta-analysis and meta-regression, 53 validation studies / 14 tools): unadjusted, QFracture had the best hip-fracture discrimination (AUC 0.88); adjusted, FRAX with BMD (0.81) and Garvan with BMD (0.79) were highest for hip fracture; for major osteoporotic fracture QFracture led (0.77); FRAX with BMD beat FRAX without for osteoporotic/any fracture (0.72 vs 0.69); substantial heterogeneity throughout
Result: For hip fracture in the unadjusted analyses, the best discriminative ability was QFracture's (AUC = 0.88). In the adjusted analysis, the highest AUCs were FRAX with BMD's (AUC = 0.81) and Garvan with BMD's (AUC = 0.79). For major osteoporotic fracture, QFracture's discriminative ability was again the best (AUC = 0.77). For osteoporotic or any fracture, the versions with BMD of FRAX and Garvan discriminated better than their versions without BMD (Garvan: AUC = 0.72 vs 0.65, FRAX: AUC = 0.72 vs 0.69). Heterogeneity was present in the analyses in significant amount.
Watch out: The adjusted AUCs come from meta-regression across different study sets, not head-to-head comparison in the same individuals — the authors themselves call for same-individual comparisons. Heterogeneity was substantial throughout.
Source: Beaudoin C et al. Performance of predictive tools to identify individuals at risk of non-traumatic fracture: a systematic review, meta-analysis, and meta-regression. Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA. 2019. PMID: 30877348. Registry ID: none in the record. MeSH: Bone Density/physiology · Hip Fractures/etiology,physiopathology · Humans · Osteoporosis/complications,physiopathology · Osteoporotic Fractures/etiology*,physiopathology · Predictive Value of Tests · Risk Assessment/methods · Risk Factors · Validation Studies as Topic
Estimate type: unadjusted estimate, as stated in the card.
Card 3 — FRISBEE validation (Baleanu 2021, JBMR Plus — primary external validation, 3,560 postmenopausal women aged 60–85, 5-year follow-up): FRAX well calibrated for hip fracture (slope 1.09; intercept −0.001) but consistently UNDERESTIMATED major osteoporotic fractures (slope 2.12); FRAX AUC 0.841 (95% CI 0.795–0.887) for hip vs Garvan 0.769 (P = 0.01), and 0.708 (0.675–0.741) for major osteoporotic fracture
Study: Validation study (primary report, external cohort)
Population: 3,560 postmenopausal volunteer women aged 60–85 years at baseline in the population-based FRISBEE cohort (Brussels), followed for 5 years; baseline data were used to calculate estimated 10-year FRAX (Belgium) risk of hip and major osteoporotic fractures, and 5-year Garvan risk with BMD.
Summary: FRISBEE validation (Baleanu 2021, JBMR Plus — primary external validation, 3,560 postmenopausal women aged 60–85, 5-year follow-up): FRAX well calibrated for hip fracture (slope 1.09; intercept −0.001) but consistently UNDERESTIMATED major osteoporotic fractures (slope 2.12); FRAX AUC 0.841 (95% CI 0.795–0.887) for hip vs Garvan 0.769 (P = 0.01), and 0.708 (0.675–0.741) for major osteoporotic fracture
Result: The FRAX tool was well calibrated for hip fractures (slope 1.09, p < 0.001; intercept −0.001, p = 0.46), but it consistently underestimated the incidence of major osteoporotic fractures (slope 2.12, p < 0.001; intercept −0.02, p = 0.06). The predictive value for hip fractures was better for FRAX (AUC 0.841, 95% CI 0.795–0.887) than for Garvan (AUC 0.769, 95% CI 0.702–0.836, p = 0.01). The FRAX AUC for major osteoporotic fractures was 0.708 (95% CI 0.675–0.741).
Watch out: Women only, one country (Belgium FRAX calibration), and 10-year FRAX risks judged against 5-year follow-up. The record prints no MeSH. The calibration split is the finding: the same tool that calibrates for hip fracture underestimates major fractures by a slope of 2.12.
Source: Baleanu F et al. Independent External Validation of FRAX and Garvan Fracture Risk Calculators: A Sub-Study of the FRISBEE Cohort. JBMR plus. 2021. PMID: 34532617. Registry ID: none in the record. MeSH: none in the record
Card 4 — Australian validation (Sandhu 2010, Osteoporosis International — primary retrospective validation, 144 women and 56 men aged 60–90, case-control sampling — labelled): in women, AUCs Garvan 0.84, FRAX-US 0.77, FRAX-UK 0.78; in men, FRAX-US 0.54 and FRAX-UK 0.57 — near chance — against Garvan 0.76; FRAX predicted probabilities in men did not even rank fracture above non-fracture cases
Study: Validation study (primary report; retrospective, case-control sampling — reduced weight, labelled)
Population: 144 women (69 fractures, 75 controls) and 56 men (31 fractures, 25 controls) aged 60–90 years in an Australian clinical setting, retrospectively sampled; predicted 10-year probabilities of major fracture were calculated from the Garvan and FRAX algorithms using US (FRAX-US) and UK (FRAX-UK) databases.
Summary: Australian validation (Sandhu 2010, Osteoporosis International — primary retrospective validation, 144 women and 56 men aged 60–90, case-control sampling — labelled): in women, AUCs Garvan 0.84, FRAX-US 0.77, FRAX-UK 0.78; in men, FRAX-US 0.54 and FRAX-UK 0.57 — near chance — against Garvan 0.76; FRAX predicted probabilities in men did not even rank fracture above non-fracture cases
Result: In women, AUC for the Garvan, FRAX-US and FRAX-UK algorithms were 0.84, 0.77 and 0.78 respectively, vs 0.76, 0.54 and 0.57 respectively in men. In men, although the Garvan model yielded higher average probability of major fracture in the fracture group (0.32 vs 0.14), the FRAX algorithm did not: FRAX-US 0.17 vs 0.19 and FRAX-UK 0.09 vs 0.12 (fracture vs non-fracture).
Watch out: A small (n=200), retrospectively sampled warning printed at reduced weight but never omitted: the male limb rests on 56 men. Its near-chance FRAX AUCs in men contradict the pooled picture and bound any claim that FRAX performance transports across sexes.
Source: Sandhu SK et al. Prognosis of fracture: evaluation of predictive accuracy of the FRAX algorithm and Garvan nomogram. Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA. 2010. PMID: 19633880. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Algorithms* · Bone Density · Epidemiologic Methods · Female · Humans · Male · Middle Aged · Nomograms · Osteoporotic Fractures/diagnosis*,physiopathology · Prognosis · Sex Factors
Card 5 — Synthesis — FRAX discrimination is outcome-bound (hip 0.81–0.84; major osteoporotic fracture 0.71–0.77) and sex-bound (near chance in one small male sample), and its calibration splits the same way: good for hip, underestimating for major fractures
Study: Synthesis
Population: 4 reports: 2 syntheses (45 and 53 validation studies, overlapping pools) + 2 primary validations (3,560 women prospectively followed; 200 retrospectively sampled patients). No single pooled FRAX AUC exists in this base and none is manufactured.
Summary: Synthesis — FRAX discrimination is outcome-bound (hip 0.81–0.84; major osteoporotic fracture 0.71–0.77) and sex-bound (near chance in one small male sample), and its calibration splits the same way: good for hip, underestimating for major fractures
Result: Hip fracture: adjusted synthesis AUC 0.81 (FRAX with BMD); FRISBEE AUC 0.841 with good calibration (slope 1.09). Major osteoporotic fracture: AUC 0.708–0.77 with consistent underestimation in FRISBEE (calibration slope 2.12). Men: AUC 0.54–0.57 in the small Australian sample against 0.77–0.78 in its women. BMD adds modestly (0.72 vs 0.69 for osteoporotic/any fracture). No report was refused on this row. Cross-point: live pack #797 (FRAX-based screening strategy, SCOOP/ROSE) is a different question.
Watch out: AUCs are discrimination only — no anchor here validates the treatment thresholds FRAX outputs are used with. Performance figures from women-dominated cohorts must not be extended to men on this evidence.
Source: Synthesis of the reports carded above; no additional source.
Estimate type: adjusted estimate, as stated in the card.