SourceMed · Shelf #8609 in the ask interface
HECSI measurement properties and interpretability — 3 reports: derivation ICC 0.79–0.84 (inter-observer) and 0.90 (intra-observer) in 15 patients, photographic-assessment comparison in 30 wet workers, and responsiveness AUC 0.86 with a smallest detectable change of 40.3 points exceeding every minimally-important-change value
Shelf #8609 · Eyes, skin, nose & allergy
MEASUREMENT PROPERTIES — reliable and responsive, with an interpretability warning that prints at headline weight: derivation inter-observer ICC 0.79–0.84 and intra-observer ICC 0.90 (15 patients, 12 dermatologists); responsiveness AUC 0.86 (95% CI 0.81–0.91) in 294 patients; but the smallest detectable change is 40.3 points and every minimally-important-change value obtained was smaller than it, so individual-patient change below ~41 points cannot be distinguished from measurement error on this evidence. Base: 1 programme derivation + 1 photographic-assessment comparison + 1 prospective interpretability study.
Stamped: 2026-11-28.
Evidence published: 2005–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the HECSI (clinician-scored intensity × extent of hand eczema signs) — its observer reliability at derivation, its performance in photographic/teledermatological assessment against the OHSI, and its responsiveness, severity bands and minimally important change?
Balance of the evidence
3 reports: 1 programme derivation (15 patients scored by 12 dermatologists — the developers' own report, programme-labelled) + 1 teledermatology comparison (120 photographic records of 30 male wet workers; a shared report whose OHSI limb is counted nowhere here) + 1 prospective responsiveness/interpretability study (294 patients). The reliability base and the interpretability base are different studies a decade and a half apart and print as such.
MeSH: Adolescent · Adult · Aged · Eczema/complications,pathology* · Female · Hand Dermatoses/complications,pathology* · Humans · Male · Middle Aged · Observer Variation · Reproducibility of Results · Severity of Illness Index* · Single-Blind Method · Dermatitis, Occupational/pathology* · Eczema/pathology* · Hand Dermatoses/pathology* · Metals · Photography · Statistics, Nonparametric · Telemedicine* · Eczema*/diagnosis · Prospective Studies · ROC Curve
Cards (4)
Card 1 — Derivation (Held 2005, British Journal of Dermatology — programme derivation, typed Validation Study): 12 dermatologists assessed 15 hand-eczema patients twice, 30 minutes apart, blinded, hands and wrists only visible; ICC for the total HECSI score 0.79 at the first assessment and 0.84 at the second; intra-observer ICC 0.90
Study: Validation study (primary report, programme derivation)
Population: 15 patients with hand eczema assessed twice (30-minute interval) by 12 dermatologists (observers), blinded, with only the hands and wrists visible.
Summary: Derivation (Held 2005, British Journal of Dermatology — programme derivation, typed Validation Study): 12 dermatologists assessed 15 hand-eczema patients twice, 30 minutes apart, blinded, hands and wrists only visible; ICC for the total HECSI score 0.79 at the first assessment and 0.84 at the second; intra-observer ICC 0.90
Result: ICC for total HECSI score was 0.79 at the first assessment and 0.84 at the second assessment. ICC for intraobserver agreement was 0.90. The authors conclude that overall excellent agreement existed for both inter- and intraobserver reliability and suggest the scoring system for use in future clinical studies on hand eczema; because HECSI is an entirely objective assessment of clinical signs, they add that inclusion of patient-rated symptoms should be considered.
Watch out: The developers' own report; the reliability sample is 15 patients (many raters, few patients) under standardised conditions — hands and wrists only, 30 minutes apart. Reliability in routine clinic conditions is not what this study measured.
Source: Held E et al. The hand eczema severity index (HECSI): a scoring system for clinical assessment of hand eczema. A study of inter- and intraobserver reliability. The British journal of dermatology. 2005. PMID: 15727643. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Eczema/complications,pathology* · Female · Hand Dermatoses/complications,pathology* · Humans · Male · Middle Aged · Observer Variation · Reproducibility of Results · Severity of Illness Index* · Single-Blind Method
Card 2 — Teledermatology comparison (Baumeister 2010, Contact Dermatitis — primary evaluation): 120 photographic records of the hands of 30 male wet workers examined twice with each of the OHSI and HECSI; inter-score correlation moderate (0.651 first examination, 0.642 second); the HECSI showed better overall agreement between first and second examinations in the qualitative assessment — a shared report, printed as shared: the OHSI limb is counted nowhere here
Study: Evaluation study (primary report; shared report — OHSI limb counted nowhere here)
Population: 120 photographic records of the hands of 30 male wet workers, each examined twice with each score (OHSI and HECSI), tested for reproducibility, intra-observer reliability and inter-score correlation in an occupational telemedical screening setting.
Summary: Teledermatology comparison (Baumeister 2010, Contact Dermatitis — primary evaluation): 120 photographic records of the hands of 30 male wet workers examined twice with each of the OHSI and HECSI; inter-score correlation moderate (0.651 first examination, 0.642 second); the HECSI showed better overall agreement between first and second examinations in the qualitative assessment — a shared report, printed as shared: the OHSI limb is counted nowhere here
Result: Examination time, mean score values, and score ranges reached did not differ significantly between the scores. The inter-score-correlation was moderate (correlation coefficients: 0.651 for first examination; 0.642 for second examination). In the qualitative assessment, the HECSI showed a better overall agreement between results of first and second examinations. The authors note the comparability is limited to qualitative assessment, as the strictly objective OHSI measures the extent of hand eczema and the finer graduated HECSI measures the intensity of hand eczema, adding a subjective component.
Watch out: Photographs of 30 male wet workers with early hand eczema — a narrow, mild-disease, single-sex occupational sample. A moderate inter-score correlation (0.65) between two scores the authors say measure different things (extent vs intensity) is not a validation of either against truth.
Source: Baumeister T et al. Spoilt for choice--evaluation of two different scoring systems for early hand eczema in teledermatological examinations. Contact dermatitis. 2010. PMID: 20433445. Registry ID: none in the record. MeSH: Adolescent · Adult · Dermatitis, Occupational/pathology* · Eczema/pathology* · Hand Dermatoses/pathology* · Humans · Male · Metals · Middle Aged · Photography · Reproducibility of Results · Severity of Illness Index* · Statistics, Nonparametric · Telemedicine*
Card 3 — Responsiveness and interpretability (Oosterhaven 2020, British Journal of Dermatology — prospective study, 294 patients at baseline and 4–12 weeks, anchored on the Photographic Guide for severity of hand eczema): responsiveness AUC 0.86 (95% CI 0.81–0.91); severity bands clear 0, almost clear 1–16, moderate 17–37, severe 38–116, very severe ≥117 (κ=0.694 against the anchor); smallest detectable change in 93 unchanged patients 40.3 points, and ALL minimally-important-change values obtained were smaller than the SDC — the authors recommend an improvement of 41 points as the minimally measurable true change
Study: Clinical study (primary report, responsiveness/interpretability)
Population: 294 patients (160 male, mean age 44.9 years) studied prospectively at baseline and after 4–12 weeks; responsiveness used a criterion approach with at least one-step improvement on the Photographic Guide as the anchor for important improvement; the smallest detectable change was calculated in 93 patients indicating no change.
Summary: Responsiveness and interpretability (Oosterhaven 2020, British Journal of Dermatology — prospective study, 294 patients at baseline and 4–12 weeks, anchored on the Photographic Guide for severity of hand eczema): responsiveness AUC 0.86 (95% CI 0.81–0.91); severity bands clear 0, almost clear 1–16, moderate 17–37, severe 38–116, very severe ≥117 (κ=0.694 against the anchor); smallest detectable change in 93 unchanged patients 40.3 points, and ALL minimally-important-change values obtained were smaller than the SDC — the authors recommend an improvement of 41 points as the minimally measurable true change
Result: HECSI scores improved or deteriorated in parallel with the anchor. The area under the ROC curve was 0.86 (95% CI 0.81–0.91). The final severity band for single scores had a κ-coefficient of agreement of 0.694: clear, 0; almost clear, 1–16; moderate, 17–37; severe, 38–116; very severe, ≥117. The SDC in 93 unchanged patients was 40.3 points. The obtained MIC values were all smaller than the SDC. The authors recommend that an improvement of 41 points on the HECSI is regarded as the minimally measurable true change.
Watch out: The interpretability warning prints at headline weight: an MIC smaller than the smallest detectable change (40.3 points) means individual-patient change below ~41 points cannot be distinguished from measurement error on this evidence — a serious limit for a score whose moderate band spans only 17–37 points.
Source: Oosterhaven JAF et al. Responsiveness and interpretability of the Hand Eczema Severity Index. The British journal of dermatology. 2020. PMID: 31260086. Registry ID: none in the record. MeSH: Adult · Eczema*/diagnosis · Female · Humans · Male · Middle Aged · Photography · Prospective Studies · ROC Curve · Reproducibility of Results · Severity of Illness Index
Card 4 — Synthesis — a reliable, responsive group-level instrument whose individual-patient change signal is swamped by measurement error below ~41 points
Study: Synthesis
Population: 3 reports: 1 programme derivation (15 patients, 12 dermatologists), 1 photographic-assessment comparison (30 male wet workers, 120 records), 1 prospective interpretability study (294 patients). No pooled N is meaningful across these limbs and none is printed.
Summary: Synthesis — a reliable, responsive group-level instrument whose individual-patient change signal is swamped by measurement error below ~41 points
Result: Inter-observer ICC 0.79–0.84 and intra-observer 0.90 at derivation; moderate correlation (0.64–0.65) with the extent-based OHSI in photographic assessment; responsiveness AUC 0.86 with defined severity bands — against an SDC of 40.3 points that exceeds every MIC obtained. No report was refused on this row.
Watch out: Group-level trial use and individual-patient monitoring are different claims: this base supports the first and warns against the second below ~41 points of change. The derivation's reliability rests on 15 patients scored under standardised conditions.
Source: Synthesis of the reports carded above; no additional source.