SourceMed · Shelf #8624 in the ask interface
Normal 12-lead ECG limits — 5 population derivations on four continents, never pooled: low-risk reference heart rate 48–98/min, PR 113–212 ms, QRS 69–109 ms (trial-screened flagship); QTc is formula-bound in every cohort
Shelf #8624 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — ESTABLISHED — normal 12-lead ECG limits are established per population across five large derivations (79,743 trial-screened individuals; 152,180 Dutch cohort members; 486,014 Brazilian primary-care ECGs; 5,360 healthy Chinese subjects; 1,261 healthy Nigerians): in the flagship's low-cardiovascular-risk subgroup the 2nd–98th percentile ranges were heart rate 48–98 beats/min, PR 113–212 ms and QRS 69–109 ms; every cohort finds marked age and sex variation, median QTc is higher in women, and QTc values are formula-bound — the limits print per population and are never pooled.
Stamped: 2026-11-28.
Evidence published: 2003–2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people without heart disease, what are the normal limits of the standard 12-lead electrocardiogram — heart rate, PR, QRS and QTc intervals and amplitudes — by age and sex, and how much do the limits differ between populations?
Balance of the evidence
5 population derivations spanning four continents and three measurement eras (cardiologist-read digital ECGs; Glasgow programme automated measurement; validated computer programme), printed per population and never pooled. Composition: one pharmaceutical-trial-database derivation (its source population is trial-screened volunteers, not a community sample, and prints as such), one Dutch population cohort, one Brazilian tele-ECG primary-care database, and Chinese and Nigerian healthy-subject derivations. QTc formulae differ by cohort (Bazett and Fridericia in the flagship; Hodges in the Nigerian cohort) and are never merged. No registry IDs in any record.
MeSH: Adolescent · Adult · Age Distribution · Aged · Aged, 80 and over · Child · Child, Preschool · Electrocardiography, Ambulatory/standards*,statistics & numerical data* · Female · Heart Rate/physiology* · Humans · Infant · Male · Middle Aged · Nevada/epidemiology · Reference Values · Reproducibility of Results · Sensitivity and Specificity · Sex Distribution · Action Potentials · Age Factors · Arrhythmias, Cardiac/diagnosis*,epidemiology*,physiopathology · Electrocardiography* · Follow-Up Studies · Heart Conduction System/physiopathology* · Heart Rate · Netherlands/epidemiology · Predictive Value of Tests · Prevalence · Prospective Studies · Sex Factors · White People · Young Adult · Brazil/epidemiology · Cardiovascular Diseases/diagnosis*,epidemiology,physiopathology · Data Mining/methods* · Databases, Factual · Electrocardiography/standards* · Heart Rate* · Infant, Newborn · Pattern Recognition, Automated · Primary Health Care* · Retrospective Studies · Signal Processing, Computer-Assisted · Software · China · Statistics, Nonparametric · Diagnosis, Computer-Assisted/standards*,statistics & numerical data* · Electrocardiography/standards*,statistics & numerical data* · Heart Conduction System/physiology* · Nigeria/epidemiology
Cards (6)
Card 1 — Trial-database derivation (Mason 2007, Journal of Electrocardiology — 79,743 individuals, ages 3 months–99 years, cardiologist-read digital ECGs): in the low-cardiovascular-risk subgroup of 46,129, 2nd–98th percentile ranges were heart rate 48–98 beats/min, PR 113–212 ms, QRS 69–109 ms, QT 325–452 ms, QTc-Bazett 361–457 ms and QTc-Fridericia 359–445 ms
Study: Normative reference study (primary report)
Population: 79,743 individuals (48% women) from pharmaceutical company-sponsored clinical trials, single baseline ECGs interpreted by cardiologists using digital technology; a subgroup of 46,129 individuals with a very low probability of cardiovascular disease provided the reference ranges.
Summary: Trial-database derivation (Mason 2007, Journal of Electrocardiology — 79,743 individuals, ages 3 months–99 years, cardiologist-read digital ECGs): in the low-cardiovascular-risk subgroup of 46,129, 2nd–98th percentile ranges were heart rate 48–98 beats/min, PR 113–212 ms, QRS 69–109 ms, QT 325–452 ms, QTc-Bazett 361–457 ms and QTc-Fridericia 359–445 ms
Result: Reference ranges (2nd–98th percentiles) in the low-risk subgroup: heart rate 48 to 98 beats/min; PR interval 113 to 212 ms; QRS interval 69 to 109 ms; frontal plane QRS axis −40 degrees to 91 degrees; QT interval 325 to 452 ms; QTc-Bazett 361 to 457 ms; QTc-Fridericia 359 to 445 ms. Marked age- and sex-related variations were observed, and the ranges differ substantially from previously reported norms.
Watch out: The source population is trial-screened volunteers, not a community sample — the limits inherit that screening. QTc is printed per formula (Bazett vs Fridericia ranges differ by up to 12 ms at the upper limit) and the two must not be merged.
Source: Mason JW et al. Electrocardiographic reference ranges derived from 79,743 ambulatory subjects. Journal of electrocardiology. 2007. PMID: 17276451. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Distribution · Aged · Aged, 80 and over · Child · Child, Preschool · Electrocardiography, Ambulatory/standards*,statistics & numerical data* · Female · Heart Rate/physiology* · Humans · Infant · Male · Middle Aged · Nevada/epidemiology · Reference Values · Reproducibility of Results · Sensitivity and Specificity · Sex Distribution
Card 2 — LifeLines cohort (van der Ende 2017, Clinical Cardiology — ECG data on 152,180 individuals aged 18–93): median P-wave, PQ and QRS durations longer in men, median QTc higher in women, most parameters rising with age; Dutch-adjusted atrial fibrillation prevalence 0.9%
Study: Normative reference study (observational cohort)
Population: 152,180 individuals aged 18 to 93 years in the LifeLines Cohort (general Dutch population); individuals with cardiovascular risk factors were excluded to analyse the healthy population, whose size the record does not state separately.
Summary: LifeLines cohort (van der Ende 2017, Clinical Cardiology — ECG data on 152,180 individuals aged 18–93): median P-wave, PQ and QRS durations longer in men, median QTc higher in women, most parameters rising with age; Dutch-adjusted atrial fibrillation prevalence 0.9%
Result: Median heart rate was highest in the youngest and oldest individuals of the healthy population. Median duration of P wave, PQ interval and QRS duration were longer in males than females; median QT interval corrected for heart rate was higher in females. In general the parameters increased with age. Prevalences of ECG abnormalities adjusted for the Dutch population: atrial fibrillation or flutter 0.9%, premature atrial complexes 1.4%, myocardial infarction 0.5%, ventricular premature complexes 2.1%, left ventricular hypertrophy 1.0%, P-R interval >200 ms 8.1%, bundle branch block 0.8%.
Watch out: The record prints directions and prevalences at abstract level rather than a full numeric limit table, and the healthy-subset N is not stated — no numeric limit is manufactured from this card. Abnormality prevalences are population-adjusted figures, not healthy-subset rates.
Source: van der Ende MY et al. Population-based values and abnormalities of the electrocardiogram in the general Dutch population: The LifeLines Cohort Study. Clinical cardiology. 2017. PMID: 28605034. Registry ID: none in the record. MeSH: Action Potentials · Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · Arrhythmias, Cardiac/diagnosis*,epidemiology*,physiopathology · Electrocardiography* · Female · Follow-Up Studies · Heart Conduction System/physiopathology* · Heart Rate · Humans · Male · Middle Aged · Netherlands/epidemiology · Predictive Value of Tests · Prevalence · Prospective Studies · Sex Factors · White People · Young Adult
Estimate type: adjusted estimate, as stated in the card.
Card 3 — Brazilian tele-ECG database (Palhares 2017, BMC Cardiovascular Disorders — 486,014 ECGs analysed after exclusions from 1,493,905 recorded, Glasgow programme): 1st–99th percentile normal values by age and sex for a Latin American primary-care population
Study: Normative reference study (retrospective database)
Population: All consecutive 12-lead digital ECGs of primary care patients at least 1 year old in Minas Gerais state, Brazil, 2010–2015; 1,493,905 ECGs recorded, 1,007,891 excluded (technical problems, selected abnormalities, self-declared comorbidities or drug therapy), 486,014 analysed; only the first ECG per patient; measurements by the University of Glasgow ECG analysis program.
Summary: Brazilian tele-ECG database (Palhares 2017, BMC Cardiovascular Disorders — 486,014 ECGs analysed after exclusions from 1,493,905 recorded, Glasgow programme): 1st–99th percentile normal values by age and sex for a Latin American primary-care population
Result: Normal values (1st, 2nd, 50th, 98th and 99th percentiles by age and sex) were provided for heart rate, P, QRS and T frontal axis, P and QRS overall duration, PR and QT overall intervals and QTc corrected by the Hodges, Bazett, Fridericia and Framingham formulae. Overall results were similar to studies in other populations, with differences at extreme ages and in specific measurements.
Watch out: A primary-care database derivation, not a screened-healthy cohort: exclusions relied partly on self-declared comorbidity. The record prints its percentile tables in the full text, not the abstract, so no per-variable numeric limit is taken from this card beyond the design and scale. Four QTc formulae are reported — formula-bound, never merged.
Source: Palhares DMF et al. Normal limits of the electrocardiogram derived from a large database of Brazilian primary care patients. BMC cardiovascular disorders. 2017. PMID: 28610624. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Distribution · Age Factors · Aged · Aged, 80 and over · Brazil/epidemiology · Cardiovascular Diseases/diagnosis*,epidemiology,physiopathology · Child · Child, Preschool · Data Mining/methods* · Databases, Factual · Electrocardiography/standards* · Female · Heart Rate* · Humans · Infant · Infant, Newborn · Male · Middle Aged · Pattern Recognition, Automated · Predictive Value of Tests · Primary Health Care* · Reference Values · Retrospective Studies · Sex Distribution · Sex Factors · Signal Processing, Computer-Assisted · Software · Young Adult
Card 4 — Chinese derivation (Wu 2003, International Journal of Cardiology — 5,360 apparently healthy Chinese subjects, computer-measured): significant age trends in P-wave duration, QTc and frontal QRS axis, and sex differences in heart rate, intervals and Sokolow/Cornell indices
Study: Normative reference study (primary report)
Population: 5,360 apparently healthy Chinese subjects (3,614 men and 1,746 women, ages 18–84 years); standard simultaneous 12-lead ECGs recorded with a modern digital recorder and processed with a validated ECG computer program; medians and 2nd/98th percentile limits calculated.
Summary: Chinese derivation (Wu 2003, International Journal of Cardiology — 5,360 apparently healthy Chinese subjects, computer-measured): significant age trends in P-wave duration, QTc and frontal QRS axis, and sex differences in heart rate, intervals and Sokolow/Cornell indices
Result: Significant age trends were present in P-wave duration, QTc interval and frontal QRS axis, with concomitant changes of R amplitudes in the extremity leads. Sex differences existed for heart rate, interval durations, the Sokolow and Cornell indices, and QRS and ST-T amplitudes in different leads. Left-precordial R-wave amplitudes in women increased with age; the Sokolow index showed a clearer age trend for men than for women, the reverse being true for the Cornell index. Some findings are at odds with established diagnostic ECG criteria, supporting age- and sex-specific criteria for a Chinese population.
Watch out: The record's abstract reports the pattern of age/sex effects qualitatively; its numeric limit tables sit in the full text and no numeric limit is manufactured here. Computer-programme measurements are not interchangeable with cardiologist-read values.
Source: Wu J et al. Normal limits of the electrocardiogram in Chinese subjects. International journal of cardiology. 2003. PMID: 12468053. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · China · Electrocardiography* · Female · Humans · Male · Middle Aged · Reference Values · Sex Factors · Signal Processing, Computer-Assisted · Statistics, Nonparametric
Card 5 — Nigerian derivation (Katibi 2013, Journal of Electrocardiology — 1,261 apparently healthy Nigerians, automated measurement): mean QRS duration 87.9 ± 9.4 ms in men vs 83.4 ± 7.6 ms in women (P < .0001) and mean QTc (Hodges) 393 ± 16 vs 406 ± 16 ms
Study: Normative reference study (primary report)
Population: 1,261 apparently healthy Nigerians (782 males and 479 females, aged 20–87 years); ECGs recorded and analysed using automated methods; age- and sex-based normal ranges established.
Summary: Nigerian derivation (Katibi 2013, Journal of Electrocardiology — 1,261 apparently healthy Nigerians, automated measurement): mean QRS duration 87.9 ± 9.4 ms in men vs 83.4 ± 7.6 ms in women (P < .0001) and mean QTc (Hodges) 393 ± 16 vs 406 ± 16 ms
Result: Mean QRS duration in males was 87.9 ± 9.4 ms and 83.4 ± 7.6 ms in females (P < .0001). Mean QTc (Hodges) was 393 ± 16 ms in males and 406 ± 16 ms in females (P < .0001). The Cornell index (SV3+RaVL) was higher in males and decreased with increasing age in males, the reverse being true in females (P < .0001). STj amplitude was lower in older compared with younger males and higher in males.
Watch out: QTc here is Hodges-formula only; its means must not be compared numerically with Bazett or Fridericia values from other cards. The smallest derivation in the row — its limits carry the widest sampling uncertainty.
Source: Katibi I et al. Normal limits of the electrocardiogram in Nigerians. Journal of electrocardiology. 2013. PMID: 23702151. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Diagnosis, Computer-Assisted/standards*,statistics & numerical data* · Electrocardiography/standards*,statistics & numerical data* · Female · Heart Conduction System/physiology* · Heart Rate/physiology* · Humans · Male · Middle Aged · Nigeria/epidemiology · Reference Values
Card 6 — Synthesis — 5 derivations, four continents, three measurement eras: limits print per population, QTc per formula, never pooled
Study: Synthesis
Population: Composition: 5 independent population derivations — 79,743 trial-screened individuals (low-risk subgroup 46,129), 152,180 Dutch cohort members (healthy subset analysed, N not stated separately), 486,014 Brazilian primary-care ECGs, 5,360 healthy Chinese subjects and 1,261 healthy Nigerians. No report was refused.
Summary: Synthesis — 5 derivations, four continents, three measurement eras: limits print per population, QTc per formula, never pooled
Result: Every derivation finds marked age and sex variation: intervals and durations generally longer in men, QTc higher in women, most parameters rising with age. The flagship's low-risk 2nd–98th percentile ranges (heart rate 48–98/min, PR 113–212 ms, QRS 69–109 ms) are the row's only full abstract-level limit set; the other cohorts contribute their printed means, directions and prevalences. Cross-points: long-QT syndrome treatment packs elsewhere in the library home a disease question, not these normative limits.
Watch out: Stamp justification: PHYSIOLOGY — ESTABLISHED on five large independent derivations agreeing on the age/sex structure; the per-population, per-formula printing rule is part of the stamp — a pooled 'normal ECG' number does not exist in this evidence.
Source: Synthesis of the reports carded above; no additional source.