SourceMed · Shelf #8626 in the ask interface

Spontaneous baroreflex sensitivity reference values — 3 independent cohorts in 4 reports (Hoorn pair counted once), 1,134 + 262 + 191 healthy subjects: BRS falls steeply with age, is log-normally distributed, and reproducibility is only moderate (coefficients of variation 34–59%)

Shelf #8626 · Brain, stroke & mind

PHYSIOLOGY — ESTABLISHED — spontaneous BRS falls with age in all 3 independent cohorts (1,134 healthy volunteers aged 18–60; 262 volunteers in six age groups; 191 randomly selected Hoorn subjects aged 50–75, in 2 reports of one programme): BRS is log-normally distributed, its sequence-technique lower limit at rest is the printed log-scale formula (−0.0283 × age) + 2.5198, and the measurement is method-dependent with only moderate reproducibility (reliability 43–81%, coefficients of variation 34–59%) — any single BRS value is a range wearing a point estimate's clothes.

Stamped: 2026-11-28.

Evidence published: 1979–2003.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the reference values for spontaneous baroreflex sensitivity (BRS) — the sequence-technique and spectral alpha-index slopes in ms/mmHg — how steeply do they fall with age, and how reproducible and method-dependent are they?

Balance of the evidence

Composition prints as 3 independent cohorts in 4 reports: the two Gerritsen reports are one Hoorn programme (191 healthy subjects within 631 participants) and are counted once. Method-dependence is the row's honest centre — breathing mode, frequency band, coherence threshold and index choice all move the number. The Valsalva pack (#6634) homes a manoeuvre-response question, not spontaneous-BRS reference values. No registry IDs in any record.

MeSH: Adolescent · Adult · Age Factors · Baroreflex*/genetics · Blood Pressure · Body Mass Index · Electrocardiography · Female · Heart Rate · Humans · Male · Middle Aged · Multivariate Analysis · Pulse · Reference Values · Smoking · White People · Aged · Blood Pressure/physiology · Child · Diastole · Heart Rate/physiology · Pressoreceptors/physiology* · Reflex/physiology* · Sex Factors · Systole · Baroreflex/physiology* · Mathematical Computing* · Regression Analysis · Reproducibility of Results · Research Design · Respiratory Physiological Phenomena* · Aging/physiology* · Autonomic Nervous System/physiology* · Cardiovascular Physiological Phenomena* · Heart/innervation,physiology · Netherlands

Cards (5)

Card 1 — Reference-value cohort (Kardos 2001, Hypertension — 1,134 healthy volunteers aged 18–60, 10-minute Finapres/ECG recordings): spontaneous BRS measurable in 90% of subjects; age, heart rate, systolic and diastolic pressure, BMI, smoking and sex were independent predictors jointly explaining 47% of variance; lnBRS fell with age (3.24 − 0.03 × age, r² = 0.23)

Study: Normative reference study (primary report)

Population: 1,134 healthy volunteers aged 18 to 60 years; BRS measured as the slope of spontaneous changes in systolic blood pressure and pulse interval from 10 minutes of Finapres blood pressure and ECG recording (spontaneous sequence technique).

Summary: Reference-value cohort (Kardos 2001, Hypertension — 1,134 healthy volunteers aged 18–60, 10-minute Finapres/ECG recordings): spontaneous BRS measurable in 90% of subjects; age, heart rate, systolic and diastolic pressure, BMI, smoking and sex were independent predictors jointly explaining 47% of variance; lnBRS fell with age (3.24 − 0.03 × age, r² = 0.23)

Result: Measurement of BRS could be obtained in 90% of subjects; those with unmeasurable BRS had a slightly lower heart rate but were otherwise not different. BRS was inversely related to age (lnBRS, 3.24−0.03xage; r² = 0.23; P < 0.0001) in both genders. Univariate analysis showed significant inverse correlations with heart rate, BMI and blood pressure; sedentary lifestyle and regular alcohol consumption were also associated with lower BRS. In the multivariate model only age, heart rate, systolic and diastolic BP, BMI, smoking and gender were independent predictors, accounting for 47% of the variance.

Watch out: A healthy working (white) population aged 18–60 — its reference values do not extend past 60. Ten percent of healthy subjects had unmeasurable spontaneous BRS, so absence of a measurable slope is itself a normal finding at this rate.

Source: Kardos A et al. Determinants of spontaneous baroreflex sensitivity in a healthy working population. Hypertension (Dallas, Tex. : 1979). 2001. PMID: 11244017. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Baroreflex*/genetics · Blood Pressure · Body Mass Index · Electrocardiography · Female · Heart Rate · Humans · Male · Middle Aged · Multivariate Analysis · Pulse · Reference Values · Smoking · White People

Card 2 — Age-group reference study (Tank 2000, American Journal of Hypertension — 262 healthy volunteers in six age groups): because BRS is log-normally distributed, the lower limit for impaired baroreflex function at rest (P = .025) on log data was (−0.0283 × age) + 2.5198 for the sequence technique; the age fall was steepest between the <40 and <50 groups; no sex difference

Study: Normative reference study (primary report)

Population: 262 healthy volunteers in six age groups (<20 years: 11 women, 9 men; 20–29: 42/37; 30–39: 23/37; 40–49: 27/22; 50–59: 19/17; 60–69: 5/13); ECG and finger arterial BP supine (7 min) and during deep breathing (6/min, 15 cycles); sequence technique and spectral alpha coefficients.

Summary: Age-group reference study (Tank 2000, American Journal of Hypertension — 262 healthy volunteers in six age groups): because BRS is log-normally distributed, the lower limit for impaired baroreflex function at rest (P = .025) on log data was (−0.0283 × age) + 2.5198 for the sequence technique; the age fall was steepest between the <40 and <50 groups; no sex difference

Result: Due to the normal logarithmic distribution of BRS, limits for impaired baroreflex function at rest were defined from logarithmic data: the limit (P = .025) was calculated as (−0.0283 x age) + 2.5198 for the sequence technique. No significant differences in BRS were found between female and male volunteers. BRS decreased significantly with age, most prominently at the transition from group III (<40 years) to group IV (<50 years). BRS at rest and during deep breathing, and sequential and spectral indices, differed significantly from each other.

Watch out: The limit formula is printed exactly as the record gives it, on its log scale — it is not a ms/mmHg value and must not be read as one. The oldest age cell is small (5 women, 13 men).

Source: Tank J et al. Reference values of indices of spontaneous baroreceptor reflex sensitivity. American journal of hypertension. 2000. PMID: 10777031. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Blood Pressure/physiology · Child · Diastole · Electrocardiography · Female · Heart Rate/physiology · Humans · Male · Middle Aged · Pressoreceptors/physiology* · Reference Values · Reflex/physiology* · Sex Factors · Systole

Card 3 — Hoorn Study methods report (Gerritsen 2000, Clinical Science — 191 randomly selected healthy subjects aged 50–75): BRS values ranged 5.0–8.9 ms/mmHg; slow metronome breathing gave higher values than fast, spectral alpha exceeded transfer-function gain, and reproducibility was only moderate (reliability coefficients 43–81%, coefficients of variation 34–59%)

Study: Normative reference study (primary report; Hoorn programme, report 1 of 2)

Population: 191 healthy subjects randomly selected from the 50–75-year-old general population (the Hoorn Study); non-invasive blood pressure and heart rate recorded during spontaneous breathing (3 min), slow metronome breathing (6 breaths/min) and fast metronome breathing (15 breaths/min), all supine; BRS as transfer gain and alpha coefficient.

Summary: Hoorn Study methods report (Gerritsen 2000, Clinical Science — 191 randomly selected healthy subjects aged 50–75): BRS values ranged 5.0–8.9 ms/mmHg; slow metronome breathing gave higher values than fast, spectral alpha exceeded transfer-function gain, and reproducibility was only moderate (reliability coefficients 43–81%, coefficients of variation 34–59%)

Result: BRS values ranged from 5.0 to 8.9 ms.mmHg⁻¹. Slow metronome breathing resulted in higher BRS values than fast breathing; during spontaneous breathing BRS in the low-frequency band was lower than in the high-frequency band. BRS values decreased with lower coherence criteria. BRS-alpha was significantly higher than BRS-gain. There were no gender differences; BRS decreased with age, and age-specific reference values were calculated. Reproducibility was in general moderate, with reliability coefficients ranging from 43 to 81% and coefficients of variation ranging from 34 to 59%.

Watch out: Same Hoorn programme as the 2003 report below — one cohort in two reports, counted once. The 5.0–8.9 ms/mmHg range spans methods and breathing modes; it is not a single-method reference interval.

Source: Gerritsen J et al. Baroreflex sensitivity in the elderly: influence of age, breathing and spectral methods. Clinical science (London, England : 1979). 2000. PMID: 11052917. Registry ID: none in the record. MeSH: Age Factors · Aged · Baroreflex/physiology* · Female · Humans · Male · Mathematical Computing* · Middle Aged · Reference Values · Regression Analysis · Reproducibility of Results · Research Design · Respiratory Physiological Phenomena* · Sex Factors

Card 4 — Hoorn Study autonomic battery (Gerritsen 2003, Diabetologia — 631 subjects aged 50–75, healthy subgroup n = 191): age- and sex-specific reference values for ten autonomic measures including BRS; agreement between measures ranged 0–87% and reproducibility was around 50% reliability — TYPE-FLAG: typed 'Clinical Trial' in PubMed for an observational cohort analysis

Study: Normative reference study (Hoorn programme, report 2 of 2; TYPE-FLAG: PubMed types this observational cohort analysis as 'Clinical Trial')

Population: 631 subjects aged 50 to 75 years in the Hoorn Study; cardiac cycle duration and continuous finger arterial pressure measured during spontaneous breathing, six deep breaths over 1 min, and lying-to-standing; ten autonomic measures assessed (mean heart rate, three Ewing measures, five heart-rate-variability measures, one BRS measure); healthy subgroup n = 191 (the same Hoorn healthy cohort as the 2000 report).

Summary: Hoorn Study autonomic battery (Gerritsen 2003, Diabetologia — 631 subjects aged 50–75, healthy subgroup n = 191): age- and sex-specific reference values for ten autonomic measures including BRS; agreement between measures ranged 0–87% and reproducibility was around 50% reliability — TYPE-FLAG: typed 'Clinical Trial' in PubMed for an observational cohort analysis

Result: In the healthy subgroup, sex differences were found for two of the ten measures and seven measures decreased with age; age-specific and sex-specific reference values were calculated. Reproducibility (n = 39) of most measures was moderate, with a reliability coefficient of around 50%. Agreement between the measures of autonomic nervous function varied greatly, between 0% and 87%; the HRV-power ratio and the lying-to-standing blood pressure changes showed the lowest agreement with all other measures.

Watch out: Not a second cohort: the healthy subgroup (n = 191) is the same Hoorn population as the 2000 methods report. Only its BRS/autonomic-battery limb is carded; the diabetes-population frame of the parent study is context only.

Source: Gerritsen J et al. Measures of cardiovascular autonomic nervous function: agreement, reproducibility, and reference values in middle age and elderly subjects. Diabetologia. 2003. PMID: 12687330. Registry ID: none in the record. MeSH: Aged · Aging/physiology* · Autonomic Nervous System/physiology* · Blood Pressure/physiology · Body Mass Index · Cardiovascular Physiological Phenomena* · Female · Heart/innervation,physiology · Heart Rate/physiology · Humans · Male · Middle Aged · Netherlands · Reference Values · Reproducibility of Results

Card 5 — Synthesis — 3 independent cohorts in 4 reports: BRS falls steeply with age, and the method moves the number as much as the person does

Study: Synthesis

Population: Composition: 3 independent cohorts in 4 reports — Kardos 1,134 (aged 18–60), Tank 262 (six age groups), and the Hoorn programme counted once (191 healthy subjects aged 50–75, reported in 2000 and 2003). No report was refused.

Summary: Synthesis — 3 independent cohorts in 4 reports: BRS falls steeply with age, and the method moves the number as much as the person does

Result: All cohorts agree BRS falls with age (steepest around the 40s in the age-group study; lnBRS slope −0.03 per year in the flagship), is log-normally distributed, and shows no consistent sex difference. They also agree on the caveat: breathing mode, frequency band, coherence threshold and index (sequence vs alpha vs transfer gain) all move the value, and reproducibility is moderate at best (coefficients of variation up to 59%). Cross-point: the founding QSART/Valsalva autonomic dataset (Low 1997) is homed at pack #6634 and is not this question.

Watch out: Stamp justification: PHYSIOLOGY — ESTABLISHED on the age fall and log-normal distribution replicated across three independent cohorts; the method-dependence and moderate reproducibility print at headline weight and bound any clinical use of a single BRS value.

Source: Synthesis of the reports carded above; no additional source.