SourceMed · Shelf #8633 in the ask interface
Bithermal caloric test responses in healthy subjects — 4 reports, N=183: a variability-and-medium row — day-to-day scores wander within 55–170% of baseline, test–retest limits 24% (right–left difference) and 22% (directional preponderance), water gives larger slow-phase velocities than air while canal-paresis percentages are medium-robust
Shelf #8633 · Brain, stroke & mind
PHYSIOLOGY — ESTABLISHED — the caloric test's normal behaviour is a variability statement, not a velocity table: in 4 reports (N=183 healthy subjects) individual scores stayed within 55–170% of their initial value with very little habituation, the upper normal limits of test–retest variation were 24% for right–left difference and 22% for directional preponderance, water slow-phase velocities exceeded air at every temperature while canal-paresis values did not differ by medium (95% CI ranges 8–12% water, 10–15% air), and wet air agreed with water at medium-to-high intraclass correlation. No electrode-era velocity table is printed: two anchors are 1970s–80s reports whose abstracts print methods and variability limits, not numeric velocity ranges.
Stamped: 2026-11-28.
Evidence published: 1977–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy subjects, what are the normal responses to bithermal caloric irrigation — peak slow-phase velocity ranges, the normal limits for canal paresis (unilateral weakness) and directional preponderance, and day-to-day variability — and how do water, dry-air and wet-air irrigation compare?
Balance of the evidence
4 reports, combined N=183 healthy subjects (43 + 30 + 60 + 50). Composition: one 1977 electronystagmography-era normative derivation whose abstract prints no numeric values (carded for its methods and distributions, with no figure taken from it), one serial-variability study (30 subjects over three successive days, 10 on 11 further occasions), one randomised water-vs-air crossover (60 subjects, Chinese-language journal, English abstract), and one prospective wet-air/dry-air/water comparison by video-oculography (50 volunteers). Fence: the 140-normal-subject air-caloric series (PMID 6968084, 1980) has a 0-character abstract and is named here in prose only; it is never carded. The homed vestibular neighbours — video head impulse test, vestibular evoked myogenic potentials, subjective visual vertical and posturography — ask different stimulus questions; this pack homes the caloric measurand only.
MeSH: Electrooculography · Hot Temperature · Humans · Posture · Reference Values · Statistics as Topic · Time Factors · Vestibular Function Tests*/methods · Caloric Tests/standards · Gait · Habituation, Psychophysiologic · Postural Balance · Vestibular Function Tests*/standards · Vestibule, Labyrinth/physiology · Adolescent · Adult · Aged · Air · Caloric Tests/methods* · Ear Canal/physiopathology* · Electronystagmography · Eye Movements/physiology* · Female · Follow-Up Studies · Male · Middle Aged · Prospective Studies · Reproducibility of Results · Therapeutic Irrigation/methods* · Vestibular Diseases/diagnosis*,physiopathology · Water* · Young Adult
Cards (5)
Card 1 — Founding normative derivation (Sills 1977, Annals of Otology, Rhinology & Laryngology Supplement — 43 normal subjects, all four irrigations): distributions tested for normality and transformed where needed, means, standard deviations and 95% confidence intervals derived, with temperature, sidedness and directionality effects identified — the abstract prints no numeric values and none is printed here
Study: Normative derivation study (primary report)
Population: 43 normal subjects examined over the four irrigations of a caloric test, with care taken at every step of testing and analysis to eliminate as much variance as possible.
Summary: Founding normative derivation (Sills 1977, Annals of Otology, Rhinology & Laryngology Supplement — 43 normal subjects, all four irrigations): distributions tested for normality and transformed where needed, means, standard deviations and 95% confidence intervals derived, with temperature, sidedness and directionality effects identified — the abstract prints no numeric values and none is printed here
Result: The normality of each variable's distribution was examined using the Wilk-Shapiro W test and corrected where necessary by the best of several transformations; the means, standard deviation and 95% confidence intervals of the resultant data were derived, and statistical tests of temperature, sidedness and directionality found several important sources of variance. The record's abstract prints no numeric caloric values.
Watch out: Electronystagmography-era methods report: it anchors the test's statistical handling (non-normal distributions, transformation, sidedness and directionality as variance sources), not any velocity figure. Any pack or reader needing a numeric peak slow-phase velocity must look to the modern anchors, not to this record.
Source: Sills AW et al. Caloric testing 2. results in normal subjects. The Annals of otology, rhinology & laryngology. Supplement. 1977. PMID: 410352. Registry ID: none in the record. MeSH: Electrooculography · Hot Temperature · Humans · Posture · Reference Values · Statistics as Topic · Time Factors · Vestibular Function Tests*/methods
Card 2 — Serial variability limits (Proctor 1986, Annals of Otology, Rhinology, and Laryngology — 30 normal subjects on three successive days, 10 on 11 further occasions): individual caloric scores generally stayed within 55–170% of their initial value, with very little habituation; upper normal limits of test–retest variation 24% for right–left difference and 22% for directional preponderance
Study: Normative variability study (primary report)
Population: 30 normal subjects tested with a short-acting caloric test on three successive days; 10 of these subjects were also tested on 11 additional occasions. Nystagmus intensity was measured by an interactive computerized technique.
Summary: Serial variability limits (Proctor 1986, Annals of Otology, Rhinology, and Laryngology — 30 normal subjects on three successive days, 10 on 11 further occasions): individual caloric scores generally stayed within 55–170% of their initial value, with very little habituation; upper normal limits of test–retest variation 24% for right–left difference and 22% for directional preponderance
Result: Individual caloric test scores generally remained between 55% and 170% of their initial value; narrower ranges resulted when scores were averaged together. There was very little habituation of caloric responses. The upper normal limits of test–retest variation in scores for right–left difference and directional preponderance of caloric responses were 24% and 22%, respectively.
Watch out: The honest centre of caloric normativity: a single score can wander by nearly half in either direction in a healthy person, so canal-paresis and preponderance percentages near these limits cannot bear much diagnostic weight on one testing occasion.
Source: Proctor L et al. Reference values for serial vestibular testing. The Annals of otology, rhinology, and laryngology. 1986. PMID: 3484929. Registry ID: none in the record. MeSH: Caloric Tests/standards · Gait · Habituation, Psychophysiologic · Humans · Postural Balance · Posture · Reference Values · Vestibular Function Tests*/standards · Vestibule, Labyrinth/physiology
Card 3 — Water vs air crossover (Liang 2018, Journal of Clinical Otorhinolaryngology Head and Neck Surgery (China) — randomised crossover, 60 healthy individuals): canal-paresis values did not differ by medium (85% (51/60) concordance as printed), water slow-phase velocities were significantly higher than air at every temperature, and the canal-paresis 95% CI ranges were 8–12% (mean 10%) for water and 10–15% (mean 12%) for air, with the air upper limit 0.21 vs the water standard 0.25 as printed
Study: Randomized crossover comparison (primary report)
Population: 60 healthy individuals randomised to two sequences (water caloric test first or air caloric test first, with a one-day interval for the elution effect); slow-phase velocity (SPV), canal paresis (CP) and their 95% CIs were the evaluation indexes. Chinese-language journal; English abstract fetched and verified.
Summary: Water vs air crossover (Liang 2018, Journal of Clinical Otorhinolaryngology Head and Neck Surgery (China) — randomised crossover, 60 healthy individuals): canal-paresis values did not differ by medium (85% (51/60) concordance as printed), water slow-phase velocities were significantly higher than air at every temperature, and the canal-paresis 95% CI ranges were 8–12% (mean 10%) for water and 10–15% (mean 12%) for air, with the air upper limit 0.21 vs the water standard 0.25 as printed
Result: The CP value did not differ statistically between the two media (concordance 85%, 51/60). The SPV value of the water caloric test was obviously higher than that of the air caloric test at each temperature. The range of water CP 95% CI was 8%–12% (average 10%); the air CP 95% CI was 10%–15% (average 12%). The study provided corresponding SPV 95% CI reference values (figures not printed in the abstract). 98.33% (59/60) of questionnaire respondents selected the air test, which was shorter and more comfortable. The upper limit of the air CP value in healthy individuals was 0.21, differing from the water standard value of 0.25, and the authors recommend each laboratory establish its own reference values.
Watch out: Canal-paresis percentages travel across media; slow-phase velocities do not — a laboratory switching from water to air inherits different velocity norms and, on this study, a different canal-paresis upper limit (0.21 vs 0.25). The record prints no MeSH (its source line reads "none in the record", as fetched) and its SPV reference intervals are stated to exist but are not printed at abstract level, so none is carded.
Source: Liang YF et al. [Clinical comparative study of caloric test with water or air in healthyindividuals and diagnosing study on air caloric test]. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery. 2018. PMID: 30282142. Registry ID: none in the record. MeSH: none in the record
Card 4 — Wet-air comparison (Gudziol 2012, The Laryngoscope — prospective comparison with reference standard, 50 volunteers with normal ear and balance function): wet-air agreed with water at medium-to-high intraclass correlation for all four irrigations, dry-air agreed less, and wet air was better tolerated than water
Study: Prospective method-comparison study (primary report)
Population: 50 volunteers with normal ear and balance function; after side-specific warm and cold dry-air, wet-air and water irrigations, experimental nystagmuses were recorded using video-oculography and peak slow-phase velocity at culmination and subjective tolerance (visual analog scale) were analysed.
Summary: Wet-air comparison (Gudziol 2012, The Laryngoscope — prospective comparison with reference standard, 50 volunteers with normal ear and balance function): wet-air agreed with water at medium-to-high intraclass correlation for all four irrigations, dry-air agreed less, and wet air was better tolerated than water
Result: The three methods differed significantly with respect to warm versus cold stimulation and stimulus side, with one exception (cold stimulation on the left side, where slow-phase velocity did not differ between dry air and wet air). The intraclass correlation coefficients of water versus wet air indicated medium-to-high agreement with the slow-phase velocity data for all four individual irrigations; the water/dry-air comparison coefficients were usually smaller, and Bland-Altman plots showed smaller individual differences for wet air vs water than for dry air vs water. Wet air had better subjective tolerability than water.
Watch out: Agreement is correlation, not interchangeability of absolute velocities: even the best-matching air method is an alternative for selected patients (anxious subjects, suspected ear-canal or tympanic-membrane findings), and its values remain method-bound.
Source: Gudziol H et al. Wet air as an alternative to traditional water irrigation during caloric vestibular testing. The Laryngoscope. 2012. PMID: 22253042. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Air · Caloric Tests/methods* · Ear Canal/physiopathology* · Electronystagmography · Eye Movements/physiology* · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prospective Studies · Reproducibility of Results · Therapeutic Irrigation/methods* · Vestibular Diseases/diagnosis*,physiopathology · Water* · Young Adult
Card 5 — Synthesis — a variability-and-medium row, not a velocity table
Study: Synthesis
Population: 4 reports, combined N=183 healthy subjects (43 + 30 + 60 + 50), spanning 1977–2018 and three recording eras (electronystagmography, computerized nystagmus measurement, video-oculography).
Summary: Synthesis — a variability-and-medium row, not a velocity table
Result: Composition restated: one founding normative derivation printing no abstract-level numbers (Sills 1977), one serial-variability study setting the test–retest limits (24% right–left difference, 22% directional preponderance; individual scores within 55–170% of initial), and two modern medium comparisons agreeing that water produces the largest slow-phase velocities while canal-paresis percentages are comparatively medium-robust (95% CI 8–12% water, 10–15% air; air upper limit 0.21 vs water standard 0.25 in the crossover study). Refused: PMID 6968084 (1980, 140 normal subjects, air caloric) — 0-character abstract, named in prose only under the standing no-abstract fence, never carded. The stamp is PHYSIOLOGY — ESTABLISHED because the variability limits and the medium effects replicate across eras and methods, even though no single peak-velocity table can honestly be printed from this base.
Watch out: Two of four anchors predate video-oculography and print limits rather than velocity tables; the modern anchors agree on direction (water largest) but each laboratory's reference values remain its own, as the crossover study itself concludes.
Source: Synthesis of the reports carded above; no additional source.