Presepsin (soluble CD14 subtype, sCD14-ST) diagnostic accuracy for sepsis — 4 syntheses with heavily overlapping pools, 2015–2019: pooled sensitivity 0.83–0.86 / specificity 0.73–0.78, AUC 0.87–0.89, statistically indistinguishable from procalcitonin in the head-to-head pools

Shelf #8656 · Critical care & sepsis

PREDICTIVE PERFORMANCE — good on paper and statistically indistinguishable from procalcitonin, capped by heterogeneity and absent prespecified thresholds: pooled presepsin sensitivity 0.83–0.86 / specificity 0.73–0.78 with AUC 0.87–0.89 across four syntheses (2015–2019, heavily overlapping pools — one literature read four ways); in the head-to-head pools there was no significant difference from procalcitonin (Kondo: presepsin 0.84 / 0.73, AUC 0.87 vs PCT 0.80 / 0.75, AUC 0.84), and in ICU studies presepsin's sensitivity exceeded PCT's (0.88 vs 0.75) at lower specificity (0.58 vs 0.75). No anchor validates a single prespecified cut-off, so no cut-off-specific pair is claimed. 4 syntheses.

Stamped: 2026-11-28.

Evidence published: 2015–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with systemic inflammation or critical illness, how accurately does presepsin (soluble CD14 subtype, sCD14-ST) diagnose sepsis — and how does its accuracy compare head-to-head with procalcitonin and C-reactive protein?

Balance of the evidence

4 syntheses, all counted as syntheses, with heavily overlapping pools from one five-year window (2015–2019): 11 studies (Zhang J 2015), 8 studies / 1,815 patients (Zhang X 2015), 18 studies / 3,470 patients (Wu 2017) and 19 observational studies / 3,012 patients (Kondo 2019). Their convergence (sensitivity 0.83–0.86, specificity 0.73–0.78, AUC 0.87–0.89) is one literature read four ways, never four independent confirmations, and prints as such. Two TYPE-FLAGs print on their cards: Wu 2017 and Kondo 2019 are typed 'Journal Article' only at PubMed although systematic reviews/meta-analyses on substance — counted on substance. One-home discipline: Kondo's procalcitonin limb is a cross-point on pack #8655 in prose only and is not carded there; the Liang 2023 comparison synthesis is carded once, on pack #8657 (MR-proADM), and its presepsin limb (0.86 / 0.79 across 33 studies) is a cross-point here in prose only. Standing caveats from the records themselves: lack of prespecified thresholds and patient-selection bias were the major deficits of the included studies (Zhang J), and heterogeneity ran I² 88–91% (Wu).

MeSH: Biomarkers · Emergency Service, Hospital · Humans · Lipopolysaccharide Receptors/blood* · Peptide Fragments/blood* · ROC Curve · Sensitivity and Specificity · Sepsis/blood*,diagnosis* · Adult · Biomarkers/blood · Reproducibility of Results · Sepsis/blood,diagnosis* · Systemic Inflammatory Response Syndrome/blood,diagnosis

Cards (5)

Card 1 — First synthesis (Zhang J 2015, Medicine — systematic review and meta-analysis, 11 studies): presepsin for sepsis sensitivity 0.83 (95% CI 0.77–0.88) / specificity 0.78 (0.72–0.83), AUC 0.88; the included studies' major deficits were lack of prespecified thresholds and patient-selection bias, as the authors state

Study: Systematic review and meta-analysis (synthesis)

Population: Patients in 11 studies published in English before November 7, 2014 assessing the diagnostic accuracy of presepsin for sepsis; the record's abstract prints a pretest probability of sepsis of 0.56 among all subjects and no pooled patient total (N not documented in the abstract).

Summary: First synthesis (Zhang J 2015, Medicine — systematic review and meta-analysis, 11 studies): presepsin for sepsis sensitivity 0.83 (95% CI 0.77–0.88) / specificity 0.78 (0.72–0.83), AUC 0.88; the included studies' major deficits were lack of prespecified thresholds and patient-selection bias, as the authors state

Result: The overall diagnostic sensitivity of presepsin for sepsis was 0.83 (95% CI: 0.77–0.88) and specificity was 0.78 (95% CI: 0.72–0.83); the area under the summary receiver operating characteristic curve was 0.88 (95% CI: 0.84–0.90). With a pretest probability of sepsis of 0.56, the posttest probabilities were 0.81 for a positive result and 0.19 for a negative result. The major design deficits of the included studies were lack of prespecified thresholds and patient selection bias; the publication bias assessment was negative. The authors conclude presepsin is an effective adjunct biomarker for the diagnosis of sepsis, but insufficient to detect or rule out sepsis when used alone.

Watch out: Post-hoc thresholds inflate accuracy: when each primary study's cut-off is chosen from its own data, the pooled pair describes the literature's best-case performance, not a test a clinician can order at a fixed cut-off. The authors' own 'insufficient alone' conclusion is part of the card, not a footnote.

Source: Zhang J et al. Diagnostic Value of Presepsin for Sepsis: A Systematic Review and Meta-Analysis. Medicine. 2015. PMID: 26632748. Registry ID: none in the record. MeSH: Biomarkers · Emergency Service, Hospital · Humans · Lipopolysaccharide Receptors/blood* · Peptide Fragments/blood* · ROC Curve · Sensitivity and Specificity · Sepsis/blood*,diagnosis*

Card 2 — SIRS-population synthesis (Zhang X 2015, Critical Care — meta-analysis, 8 studies / 1,815 patients with systemic inflammatory response syndrome): presepsin sensitivity 0.86 (95% CI 0.79–0.91) / specificity 0.78 (0.68–0.85), positive likelihood ratio 3.8 and negative likelihood ratio 0.18 (likelihood ratios, labelled as such), AUC 0.89

Study: Meta-analysis (synthesis)

Population: 1,815 adult patients with systemic inflammatory response syndrome (SIRS) in 8 studies assessing the diagnostic accuracy of presepsin for sepsis.

Summary: SIRS-population synthesis (Zhang X 2015, Critical Care — meta-analysis, 8 studies / 1,815 patients with systemic inflammatory response syndrome): presepsin sensitivity 0.86 (95% CI 0.79–0.91) / specificity 0.78 (0.68–0.85), positive likelihood ratio 3.8 and negative likelihood ratio 0.18 (likelihood ratios, labelled as such), AUC 0.89

Result: The pooled sensitivity, specificity, diagnostic odds ratio, positive likelihood ratio and negative likelihood ratio were 0.86 (95% CI: 0.79–0.91), 0.78 (95% CI: 0.68–0.85), 22 (95% CI: 10–48), 3.8 (95% CI: 2.6–5.7) and 0.18 (95% CI: 0.11–0.28) respectively. The area under the summary receiver operator characteristic curve was 0.89 (95% CI: 0.86–0.92). Meta-regression revealed that consecutive patient selection, sample size and setting significantly accounted for the heterogeneity of sensitivity. The authors conclude presepsin exhibits very good diagnostic accuracy for sepsis, while noting that an overall assessment of all clinical indexes and continual re-evaluation are needed.

Watch out: A likelihood ratio of 3.8 (positive) / 0.18 (negative) moves probability moderately, not decisively — the pair and the ratios describe the same modest discrimination, and neither may be read as rule-in/rule-out performance. The specificity interval (0.68–0.85) is wide for an 8-study pool, and the meta-regression's finding that patient selection drives sensitivity heterogeneity is the transport warning.

Source: Zhang X et al. The accuracy of presepsin (sCD14-ST) for the diagnosis of sepsis in adults: a meta-analysis. Critical care (London, England). 2015. PMID: 26357898. Registry ID: none in the record. MeSH: Adult · Biomarkers/blood · Humans · Lipopolysaccharide Receptors/blood* · Peptide Fragments/blood* · Reproducibility of Results · Sepsis/blood,diagnosis* · Systemic Inflammatory Response Syndrome/blood,diagnosis

Card 3 — Head-to-head synthesis (Wu 2017, Annals of Intensive Care — systematic review and meta-analysis, 18 studies / 3,470 patients; TYPE-FLAG: typed 'Journal Article' only at PubMed, a meta-analysis on substance): presepsin 0.84 (95% CI 0.80–0.87) / 0.76 (0.67–0.82), AUC 0.88; no significant difference vs procalcitonin or CRP overall; in ICU studies presepsin sensitivity exceeded PCT's (0.88 vs 0.75) at lower specificity (0.58 vs 0.75); heterogeneity I² 88–91%

Study: Systematic review and meta-analysis (synthesis) — TYPE-FLAG: typed Journal Article only at PubMed; counted on substance

Population: 3,470 adult patients in 18 studies evaluating the diagnostic accuracy of presepsin for sepsis, with head-to-head comparison against C-reactive protein (CRP) and procalcitonin (PCT) within the same pool.

Summary: Head-to-head synthesis (Wu 2017, Annals of Intensive Care — systematic review and meta-analysis, 18 studies / 3,470 patients; TYPE-FLAG: typed 'Journal Article' only at PubMed, a meta-analysis on substance): presepsin 0.84 (95% CI 0.80–0.87) / 0.76 (0.67–0.82), AUC 0.88; no significant difference vs procalcitonin or CRP overall; in ICU studies presepsin sensitivity exceeded PCT's (0.88 vs 0.75) at lower specificity (0.58 vs 0.75); heterogeneity I² 88–91%

Result: The pooled sensitivity and specificity of presepsin for sepsis were 0.84 (95% CI 0.80–0.87) and 0.76 (95% CI 0.67–0.82), with diagnostic odds ratio 16 (95% CI 10–25), positive likelihood ratio 3.4 (2.5–4.6), negative likelihood ratio 0.22 (0.17–0.27) (likelihood ratios, labelled as such) and AUC 0.88 (95% CI 0.85–0.90). Significant heterogeneity was found in both sensitivities (I² = 87.63%) and specificities (I² = 90.60%). There was no significant difference between presepsin and PCT or between presepsin and CRP in AUC. However, for studies conducted in ICU, the pooled sensitivity of presepsin was higher than PCT (0.88, 95% CI 0.82–0.92 vs 0.75, 0.68–0.81), while its pooled specificity was lower (0.58, 0.42–0.73 vs 0.75, 0.65–0.83). The record prints no MeSH; that absence is printed, not filled in.

Watch out: The ICU limb is a trade, not a win: sensitivity 0.88 bought at specificity 0.58 means roughly four in ten non-septic ICU patients test positive. With I² near 90% for both sensitivity and specificity, the pooled pair is an average over discordant studies; the authors themselves caution that too few studies were included and results should be interpreted carefully.

Source: Wu CC et al. Comparison of diagnostic accuracy in sepsis between presepsin, procalcitonin, and C-reactive protein: a systematic review and meta-analysis. Annals of intensive care. 2017. PMID: 28875483. Registry ID: none in the record. MeSH: none in the record

Card 4 — Head-to-head synthesis in critical illness (Kondo 2019, Journal of Intensive Care — systematic review and meta-analysis, 19 observational studies / 3,012 critically ill adults; TYPE-FLAG: typed 'Journal Article' only at PubMed, a meta-analysis on substance): only its presepsin limb is counted here — presepsin 0.84 (95% CI 0.80–0.88) / 0.73 (0.61–0.82), AUC 0.87, with no statistically significant difference from procalcitonin in pooled sensitivity (p = 0.48) or specificity (p = 0.57)

Study: Systematic review and meta-analysis (synthesis) — TYPE-FLAG: typed Journal Article only at PubMed; counted on substance

Population: 3,012 critically ill adult patients in 19 observational studies (no randomized controlled trials) differentiating sepsis from other non-infectious causes of systemic inflammation.

Summary: Head-to-head synthesis in critical illness (Kondo 2019, Journal of Intensive Care — systematic review and meta-analysis, 19 observational studies / 3,012 critically ill adults; TYPE-FLAG: typed 'Journal Article' only at PubMed, a meta-analysis on substance): only its presepsin limb is counted here — presepsin 0.84 (95% CI 0.80–0.88) / 0.73 (0.61–0.82), AUC 0.87, with no statistically significant difference from procalcitonin in pooled sensitivity (p = 0.48) or specificity (p = 0.57)

Result: Analyses of summary receiver operating characteristic curves revealed an area under the curve of 0.87 for presepsin. The pooled sensitivity and specificity for presepsin were 0.84 (95% confidence interval 0.80 to 0.88) and 0.73 (95% confidence interval 0.61 to 0.82) respectively. There were no statistically significant differences in pooled sensitivities (p = 0.48) or specificities (p = 0.57) between procalcitonin and presepsin — the procalcitonin limb's own figures are a prose cross-point on pack #8655 and are not printed here, per one-home discipline. The authors conclude the diagnostic accuracy of procalcitonin and presepsin in detecting infection was similar and that both are useful for early diagnosis of sepsis in critically ill adult patients. The record prints no MeSH; that absence is printed, not filled in. PROSPERO registration CRD42016035784 is printed in the record's abstract text only (no databank registry entry).

Watch out: One-home discipline: this report is carded here only; its procalcitonin limb is a prose cross-point on pack #8655, never a second home. 'No significant difference' in overlapping observational pools is not proof of equivalence — the presepsin specificity interval (0.61–0.82) is wide enough to include materially worse performance.

Source: Kondo Y et al. Diagnostic value of procalcitonin and presepsin for sepsis in critically ill adult patients: a systematic review and meta-analysis. Journal of intensive care. 2019. PMID: 31016020. Registry ID: none in the record (PROSPERO CRD42016035784 printed in the abstract text only). MeSH: none in the record

Card 5 — Synthesis — one literature read four ways; parity with PCT is the honest headline

Study: Synthesis

Population: 4 syntheses with heavily overlapping pools, 2015–2019 (11 studies; 8 studies / 1,815 patients; 18 studies / 3,470 patients; 19 studies / 3,012 patients). Study and patient totals overlap and are never summed.

Summary: Synthesis — one literature read four ways; parity with PCT is the honest headline

Result: Composition restated: four meta-analytic reads of substantially the same primary literature converge on presepsin sensitivity 0.83–0.86 / specificity 0.73–0.78, AUC 0.87–0.89 — convergence that reflects shared primary studies, not independent replication. The head-to-head evidence (Wu; Kondo) finds no significant overall advantage over procalcitonin, and the one subgroup advantage (ICU sensitivity 0.88 vs 0.75) is paid for in specificity (0.58 vs 0.75). The stamp is therefore PREDICTIVE PERFORMANCE — good on paper, parity with the incumbent marker — capped by the deficits the records themselves name: no prespecified thresholds in the primary studies, patient-selection bias, and heterogeneity I² 88–91%. Cross-point in prose only: the Liang 2023 comparison synthesis is carded on pack #8657, and its presepsin limb (sensitivity 0.86 / specificity 0.79, AUC 0.90, across 33 studies) extends this same literature without changing the parity picture. No report was refused on this row.

Watch out: Nothing carded here shows presepsin-guided management improving any patient outcome, and no anchor validates a cut-off a laboratory could adopt as-is. A newer marker matching an older one's accuracy is not, by itself, a reason to switch — that judgement is the developer's, and the face makes no such claim.

Source: Synthesis of the reports carded above; no additional source.