SourceMed · Shelf #8666 in the ask interface

Faecal immunochemical test (FIT) for colorectal cancer screening — 3 syntheses: pooled sensitivity 0.79 / specificity 0.94, threshold-bound (CRC sensitivity 80% at ≤10 µg/g vs 69% at >10–≤20 µg/g; advanced-adenoma sensitivity only 31% vs 21%), and 93% / 91% in increased-risk people on very-low-GRADE evidence

Shelf #8666 · Liver & gut

PREDICTIVE PERFORMANCE — diagnostic accuracy: threshold-bound (pooled CRC sensitivity 0.79 / specificity 0.94 in the 2014 pool; lowering the threshold to ≤10 µg/g raises CRC sensitivity from 69% to 80% and advanced-adenoma sensitivity from 21% to 31% while specificity falls 94% → 91%); advanced-adenoma sensitivity is poor at every threshold (21–48%) — FIT is a cancer test that largely misses the precursors screening exists to find, and that prints at headline weight; the increased-risk pool's 93% sensitivity carries a 53–99% interval and a very-low GRADE rating and prints at reduced weight

Stamped: 2026-11-28.

Evidence published: 2014–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In asymptomatic adults undergoing colorectal cancer screening, how accurately does a single faecal immunochemical test (FIT) detect colorectal cancer and advanced adenoma/neoplasia against colonoscopy or registry follow-up — overall, by positivity threshold, and in people at increased (personal/familial) risk?

Balance of the evidence

The composition is 3 syntheses with overlapping pools in two different risk spectra (average-risk screening vs increased personal/familial risk) — spectra print per anchor and their pairs are never merged. Reference standards differ (colonoscopy vs registry follow-up); the 2019 pool's finding that the two give similar CRC sensitivity (74% vs 75%) prints on its card. Brand and assay differences sit inside the threshold effect and are not separable in these pools. Cross-points in prose only: pack #2622 (multitarget stool DNA vs FIT comparative detection) and pack #3381 (FIT screening intervals) ask different questions. PROSPERO CRD42017068760 is printed in the Selby record's abstract text only (its databank list is empty) and is carried verbatim, flagged on the card. No registry IDs in the other two records' databank lists.

MeSH: Adult · Colorectal Neoplasms/diagnosis* · Early Detection of Cancer/methods · Feces/chemistry* · Humans · Immunochemistry/standards* · Occult Blood · Sensitivity and Specificity · Adenoma/diagnosis* · Age Factors · Colonoscopy · Early Detection of Cancer/methods,standards* · Hemoglobins/analysis · Mass Screening/methods,standards* · Occult Blood* · Reference Standards · Sex Factors · Colorectal Neoplasms*/diagnosis,pathology · Dimensional Measurement Accuracy · Early Detection of Cancer*/methods,standards · Feces* · Immunochemistry/methods · Neoplasm Staging · Risk Assessment/methods

Cards (4)

Card 1 — Average-risk pool (Lee 2014, Annals of Internal Medicine — systematic review and meta-analysis, 19 studies in asymptomatic average-risk adults): pooled CRC sensitivity 0.79 (95% CI 0.69–0.86) / specificity 0.94 (0.92–0.95), LR+ 13.10, LR− 0.23 (likelihood ratios, labelled as such); sensitivity 0.89 at cut-offs <20 µg/g vs 0.70 at 20–50 µg/g; single-sample FIT performed like multiple samples

Study: Systematic review and meta-analysis (synthesis)

Population: Asymptomatic, average-risk adults in 19 eligible studies of FIT accuracy for colorectal cancer (1996–2013 literature), as printed in the record; no pooled participant N is printed in the abstract.

Summary: Average-risk pool (Lee 2014, Annals of Internal Medicine — systematic review and meta-analysis, 19 studies in asymptomatic average-risk adults): pooled CRC sensitivity 0.79 (95% CI 0.69–0.86) / specificity 0.94 (0.92–0.95), LR+ 13.10, LR− 0.23 (likelihood ratios, labelled as such); sensitivity 0.89 at cut-offs <20 µg/g vs 0.70 at 20–50 µg/g; single-sample FIT performed like multiple samples

Result: The pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio of FITs for CRC were 0.79 (95% CI, 0.69 to 0.86), 0.94 (CI, 0.92 to 0.95), 13.10 (CI, 10.49 to 16.35) and 0.23 (CI, 0.15 to 0.33) (likelihood ratios, labelled as such), with overall diagnostic accuracy 95% (CI, 93% to 97%). There was substantial heterogeneity in both pooled estimates. Sensitivity improved with lower cut-offs (0.89 [CI, 0.80 to 0.95] at <20 µg/g vs 0.70 [CI, 0.55 to 0.81] at 20 to 50 µg/g) with a corresponding decrease in specificity. A single-sample FIT had similar sensitivity and specificity as several samples, independent of FIT brand.

Watch out: Only English-language articles were included, and lack of data prevented complete subgroup analyses by FIT brand — the threshold effect and the brand effect cannot be separated in this pool. Substantial heterogeneity stands behind both pooled figures.

Source: Lee JK et al. Accuracy of fecal immunochemical tests for colorectal cancer: systematic review and meta-analysis. Annals of internal medicine. 2014. PMID: 24658694. Registry ID: none in the record. MeSH: Adult · Colorectal Neoplasms/diagnosis* · Early Detection of Cancer/methods · Feces/chemistry* · Humans · Immunochemistry/standards* · Occult Blood · Sensitivity and Specificity

Card 2 — Threshold pool (Selby 2019, Gastroenterology — systematic review and meta-analysis by threshold, sex and age, 46 studies / 2.4 million participants / 6,478 cancers): CRC sensitivity 80% (76–83) at ≤10 µg/g vs 69% (63–75) at >10–≤20 µg/g; advanced-adenoma sensitivity 31% vs 21%; specificity 91% vs 94%; colonoscopy and 2-year registry follow-up gave similar CRC sensitivity (74% vs 75%)

Study: Systematic review and meta-analysis (synthesis)

Population: 2.4 million asymptomatic adults undergoing screening in 46 studies, with 6,478 detected cancers, as printed in the record; thresholds in µg haemoglobin/g faeces as the record prints them.

Summary: Threshold pool (Selby 2019, Gastroenterology — systematic review and meta-analysis by threshold, sex and age, 46 studies / 2.4 million participants / 6,478 cancers): CRC sensitivity 80% (76–83) at ≤10 µg/g vs 69% (63–75) at >10–≤20 µg/g; advanced-adenoma sensitivity 31% vs 21%; specificity 91% vs 94%; colonoscopy and 2-year registry follow-up gave similar CRC sensitivity (74% vs 75%)

Result: Sensitivity for CRC increased from 69% (95% CI, 63%–75%) at thresholds >10 μg/g and ≤20 μg/g to 80% (95% CI, 76%–83%) at thresholds ≤10 μg/g. At these thresholds, sensitivity for advanced adenomas increased from 21% (95% CI, 18%–25%) to 31% (95% CI, 27%–35%), whereas specificity decreased from 94% (95% CI, 93%–96%) to 91% (95% CI, 89%–93%). In 3 studies stratified by sex, CRC sensitivity was 77% in men (95% CI, 75%–79%) and 81% in women (95% CI, 60%–100%) (P = .68); by age, 85% at 50–59 years vs 73% at 60–69 years (P = .10). Colonoscopy follow-up and 2-year registry follow-up studies gave similar CRC sensitivity (74%; 95% CI, 68%–78% vs 75%; 95% CI, 73%–77%).

Watch out: The advanced-adenoma limb is the honest limit of FIT screening: even at the lowest threshold, 69% of advanced adenomas are missed. Sex and age strata rest on only 3 studies each, and the women's interval (60%–100%) shows it.

Source: Selby K et al. Effect of Sex, Age, and Positivity Threshold on Fecal Immunochemical Test Accuracy: A Systematic Review and Meta-analysis. Gastroenterology. 2019. PMID: 31472152. Registry ID: CRD42017068760 (PROSPERO — printed in the record's abstract text only; none in the record's databank list). MeSH: Adenoma/diagnosis* · Age Factors · Colonoscopy · Colorectal Neoplasms/diagnosis* · Early Detection of Cancer/methods,standards* · Hemoglobins/analysis · Humans · Mass Screening/methods,standards* · Occult Blood* · Reference Standards · Sensitivity and Specificity · Sex Factors

Card 3 — Increased-risk pool (Katsoula 2017, JAMA Internal Medicine — meta-analysis in asymptomatic people at above-average personal/familial risk, 12 studies / 6,204 participants, colonoscopy reference): CRC sensitivity 93% (95% CI 53–99) / specificity 91% (89–92) — the sensitivity interval spans nearly the whole scale and the evidence was GRADEd very low by the authors; printed with both warnings, at reduced weight; advanced neoplasia 48% (39–57) / 93% (91–94)

Study: Meta-analysis (synthesis) — reduced-weight limb (very-low-GRADE evidence, as rated in the record)

Population: 6,204 asymptomatic participants with a personal or familial history of colorectal cancer in 12 studies, colonoscopy as the reference standard; 7 studies were deemed at high or unclear risk of bias, as printed in the record.

Summary: Increased-risk pool (Katsoula 2017, JAMA Internal Medicine — meta-analysis in asymptomatic people at above-average personal/familial risk, 12 studies / 6,204 participants, colonoscopy reference): CRC sensitivity 93% (95% CI 53–99) / specificity 91% (89–92) — the sensitivity interval spans nearly the whole scale and the evidence was GRADEd very low by the authors; printed with both warnings, at reduced weight; advanced neoplasia 48% (39–57) / 93% (91–94)

Result: The average sensitivity of FIT for CRC was 93% (95% CI, 53%–99%) and average specificity 91% (95% CI, 89%–92%), yielding LR+ 10.30 (CI 7.7–13.9) and LR− 0.08 (95% CI, 0.01–0.75) (likelihood ratios, labelled as such) (GRADE: very low). For advanced neoplasia, sensitivity was 48% (95% CI, 39%–57%) and specificity 93% (95% CI, 91%–94%), LR+ 6.55, LR− 0.57 (GRADE: very low). Subgroup analysis indicated cut-offs of 15–25 µg/g faeces gave the best combination for CRC (93% and 94%). The authors conclude FIT has high overall accuracy for CRC but moderate accuracy for advanced neoplasia in this population, with heterogeneity and wide confidence intervals limiting trustworthiness.

Watch out: A 93% sensitivity whose interval runs 53–99% is not a precise claim; this card is never the pack's headline. The spectrum also differs — increased-risk patients under colonoscopy surveillance are not the average-risk screening population of the other two cards, and the pairs are never merged.

Source: Katsoula A et al. Diagnostic Accuracy of Fecal Immunochemical Test in Patients at Increased Risk for Colorectal Cancer: A Meta-analysis. JAMA internal medicine. 2017. PMID: 28628706. Registry ID: none in the record. MeSH: Colorectal Neoplasms*/diagnosis,pathology · Dimensional Measurement Accuracy · Early Detection of Cancer*/methods,standards · Feces* · Humans · Immunochemistry/methods · Neoplasm Staging · Risk Assessment/methods

Card 4 — Synthesis — FIT's accuracy is a dial, not a constant: every point of cancer sensitivity bought by lowering the threshold is paid for in specificity and colonoscopies, and advanced adenomas are missed at every setting

Study: Synthesis

Population: 3 syntheses: Lee 2014 (19 studies, average-risk; no pooled N printed), Selby 2019 (46 studies / 2.4 million participants / 6,478 cancers), Katsoula 2017 (12 studies / 6,204 increased-risk participants, reduced weight).

Summary: Synthesis — FIT's accuracy is a dial, not a constant: every point of cancer sensitivity bought by lowering the threshold is paid for in specificity and colonoscopies, and advanced adenomas are missed at every setting

Result: CRC pairs by threshold: 0.79 / 0.94 overall (2014); 80% / 91% at ≤10 µg/g vs 69% / 94% at >10–≤20 µg/g (2019). Advanced-adenoma sensitivity: 21–31% by threshold (2019), 48% for advanced neoplasia in increased-risk patients (2017). Refused: nothing refused at build; packs #2622 and #3381 cross-pointed in prose only. The Selby PROSPERO ID (CRD42017068760) is carried from the record's abstract text, flagged on its card, because the record's databank list is empty. Stamp justification: PREDICTIVE PERFORMANCE with the threshold trade and the precursor miss printed inside the stamp sentence.

Watch out: Thresholds are in µg haemoglobin/g faeces as the records print them; a figure quoted without its threshold is not a figure from this pack.

Source: Synthesis of the reports carded above; no additional source.