Fetal Doppler reference ranges in normal pregnancy — 3 cohorts in 4 reports (130 longitudinal + 72,387 cross-sectional + 2,516 nomogram pregnancies): umbilical PI falls continuously, middle cerebral PI peaks at ~32 weeks and cerebroplacental ratio at ~34 weeks, and umbilical values depend on the insonation site
Shelf #8688 · Women’s health
PHYSIOLOGY — ESTABLISHED — for the shapes, replicated by three independent cohorts (longitudinal, cross-sectional and nomogram designs): umbilical artery pulsatility index falls continuously through the second half of pregnancy without plateau or term rise; middle cerebral artery PI rises to a peak at ~32 weeks and cerebroplacental ratio at ~34 weeks, then falls; umbilical velocities and PI are higher at the intra-abdominal portion and fetal end than at the placental end; and measurement variability is material (intraobserver coefficients of variation 6.8–13.0%). No carded record prints a numeric centile table, so the stamp claims the shapes and the method warnings — including that charts can share a median and differ in spread — and no centile value is printed.
Stamped: 2026-11-28.
Evidence published: 2005–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In normal pregnancy, what are the reference ranges for fetal Doppler indices — umbilical artery pulsatility index, middle cerebral artery pulsatility index and the cerebroplacental ratio — how do they change with gestational age, and how much does the insonation site move the umbilical values?
Balance of the evidence
4 reports, 3 independent cohorts: the Tromsø longitudinal cohort (130 low-risk singleton pregnancies, 513 observations) reported twice — insonation-site ranges and free-loop indices — counted as one cohort in two reports everywhere on this shelf; the Fetal Medicine Foundation cross-sectional study (72,387 pregnancies, deliberately all-comers — reference ranges, not normal ranges, printed as such); and the Rizzo nomograms (2,516 low-risk pregnancies). Total pregnancies across cohorts = 75,033, never pooled into a combined centile. No registry IDs in any record. Cross-points in prose only: fetal growth standards and cord blood gases home different measurands.
MeSH: Blood Flow Velocity · Female · Fetus/blood supply* · Gestational Age · Humans · Placenta/blood supply* · Pregnancy · Prospective Studies · Pulsatile Flow · Reference Values · Ultrasonography, Doppler/methods,standards · Ultrasonography, Prenatal/methods,standards · Umbilical Arteries/diagnostic imaging,physiology* · Adolescent · Adult · Birth Weight · Infant, Newborn · Longitudinal Studies · Male · Observer Variation · Pregnancy Trimester, Second · Pregnancy Trimester, Third · Sex Factors · Ultrasonography, Doppler · Umbilical Arteries/anatomy & histology,diagnostic imaging* · Cross-Sectional Studies · Middle Cerebral Artery/diagnostic imaging*,embryology · Pulsatile Flow* · Ultrasonography, Doppler, Color* · Ultrasonography, Prenatal* · Umbilical Arteries/diagnostic imaging* · Middle Cerebral Artery/diagnostic imaging · Nomograms* · Placenta · Ultrasonography, Prenatal/methods · Umbilical Arteries*/diagnostic imaging
Cards (5)
Card 1 — Tromsø longitudinal cohort, site report (Acharya 2005, Ultrasound in Obstetrics & Gynecology — 130 low-risk singleton pregnancies, 513 observations at 4-weekly intervals, 19–42 weeks): umbilical artery velocities and pulsatility index were higher at the intra-abdominal portion and fetal end than at the placental end, with site differences themselves changing with gestation — same Tromsø cohort as the next card, counted as one cohort in two reports
Study: Reference-range derivation (longitudinal cohort, insonation-site report)
Population: 130 low-risk singleton pregnancies in a prospective longitudinal study; umbilical artery blood flow velocities measured at the intra-abdominal portion, fetal end and placental end at 4-weekly intervals at 19–42 weeks of gestation; 513 observations used to construct the reference ranges.
Summary: Tromsø longitudinal cohort, site report (Acharya 2005, Ultrasound in Obstetrics & Gynecology — 130 low-risk singleton pregnancies, 513 observations at 4-weekly intervals, 19–42 weeks): umbilical artery velocities and pulsatility index were higher at the intra-abdominal portion and fetal end than at the placental end, with site differences themselves changing with gestation — same Tromsø cohort as the next card, counted as one cohort in two reports
Result: Umbilical artery blood velocities and pulsatility index were higher at the intra-abdominal portion and fetal end than at the placental end. The gestational age-related increase of end-diastolic velocity was greater than the corresponding increase of peak systolic velocity at all locations. The mean differences (delta values) of velocities between the fetal and placental ends increased, and that of pulsatility index decreased, with advancing gestational age. Reference ranges for velocities and PI at the standardized locations were established from the longitudinal observations.
Watch out: Same cohort as the next card — the pair is one cohort in two reports and is never counted twice. The record prints no numeric centile table at abstract level, and none is taken from it: this card establishes site-dependence and direction of travel, not centile values.
Source: Acharya G et al. Reference ranges for serial measurements of blood velocity and pulsatility index at the intra-abdominal portion, and fetal and placental ends of the umbilical artery. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2005. PMID: 15883983. Registry ID: none in the record. MeSH: Blood Flow Velocity · Female · Fetus/blood supply* · Gestational Age · Humans · Placenta/blood supply* · Pregnancy · Prospective Studies · Pulsatile Flow · Reference Values · Ultrasonography, Doppler/methods,standards · Ultrasonography, Prenatal/methods,standards · Umbilical Arteries/diagnostic imaging,physiology*
Card 2 — Tromsø longitudinal cohort, free-loop report (Acharya 2005, American Journal of Obstetrics and Gynecology — same 130 pregnancies, same 513 observations): longitudinal percentiles for pulsatility index, resistance index and systolic:diastolic ratio fell continuously through the second half of pregnancy without plateau or term rise, differing slightly from cross-sectional charts; intraobserver coefficients of variation 10.5% (PI), 6.8% (RI), 13.0% (S/D) — same-cohort second report, counted as such
Study: Reference-range derivation (longitudinal cohort, same-cohort second report)
Population: The same 130 low-risk singleton pregnancies and 513 observations as the preceding card; umbilical artery Doppler indices obtained serially at the free loop of the umbilical cord at 4-week intervals at 19 to 42 weeks of gestation.
Summary: Tromsø longitudinal cohort, free-loop report (Acharya 2005, American Journal of Obstetrics and Gynecology — same 130 pregnancies, same 513 observations): longitudinal percentiles for pulsatility index, resistance index and systolic:diastolic ratio fell continuously through the second half of pregnancy without plateau or term rise, differing slightly from cross-sectional charts; intraobserver coefficients of variation 10.5% (PI), 6.8% (RI), 13.0% (S/D) — same-cohort second report, counted as such
Result: Longitudinally established percentiles of the Doppler indices showed a continuous reduction throughout the second half of pregnancy without any plateau or increase near term, as reported previously in cross-sectional studies. There was a significant negative association between Doppler indices and placental weight and neonatal birth weight, but not with gender. The intraobserver coefficients of variation for umbilical artery pulsatility index, resistance index and systolic:diastolic ratio were 10.5%, 6.8% and 13.0% respectively.
Watch out: Same-cohort second report — counted as one cohort with the preceding card in every total on this shelf. Measurement variability is material (CVs ~7–13%): a single PI reading carries that much observer noise before any biology is invoked.
Source: Acharya G et al. Reference ranges for serial measurements of umbilical artery Doppler indices in the second half of pregnancy. American journal of obstetrics and gynecology. 2005. PMID: 15746695. Registry ID: none in the record. MeSH: Adolescent · Adult · Birth Weight · Female · Humans · Infant, Newborn · Longitudinal Studies · Male · Observer Variation · Pregnancy · Pregnancy Trimester, Second · Pregnancy Trimester, Third · Prospective Studies · Reference Values · Sex Factors · Ultrasonography, Doppler · Umbilical Arteries/anatomy & histology,diagnostic imaging*
Card 3 — Fetal Medicine Foundation reference ranges (Ciobanu 2019, Ultrasound in Obstetrics & Gynecology — cross-sectional study of 72,387 pregnancies at routine examinations): umbilical artery PI fell linearly with gestational age while middle cerebral artery PI and cerebroplacental ratio rose to peaks at ~32 and ~34 weeks respectively and fell thereafter; maternal age, BMI, racial origin, conception method and parity all shifted the multiples of the median — the cohort deliberately included pregnancies with maternal disease and complications, because it built reference (not 'normal') ranges, and prints as such
Study: Reference-range derivation (cross-sectional, all-comers by design)
Population: 72,387 singleton pregnancies undergoing routine ultrasound examination at 20+0 to 22+6 weeks (n = 3,712), 31+0 to 33+6 weeks (n = 29,035), 35+0 to 36+6 weeks (n = 37,252) or 41+0 to 41+6 weeks (n = 2,388), with dating by crown-rump length, live birth of a morphologically normal neonate, and measurements by Fetal Medicine Foundation-certificated sonographers. All pregnancies having routine examinations were included irrespective of pre-existing maternal medical conditions or pregnancy complications.
Summary: Fetal Medicine Foundation reference ranges (Ciobanu 2019, Ultrasound in Obstetrics & Gynecology — cross-sectional study of 72,387 pregnancies at routine examinations): umbilical artery PI fell linearly with gestational age while middle cerebral artery PI and cerebroplacental ratio rose to peaks at ~32 and ~34 weeks respectively and fell thereafter; maternal age, BMI, racial origin, conception method and parity all shifted the multiples of the median — the cohort deliberately included pregnancies with maternal disease and complications, because it built reference (not 'normal') ranges, and prints as such
Result: The relationship between the median and gestational age was linear for umbilical artery PI and cubic for middle cerebral artery PI and cerebroplacental ratio. MCA-PI and CPR increased with gestational age from 20 weeks to reach a peak at around 32 and 34 weeks respectively and decreased thereafter, whereas UA-PI decreased linearly with gestational age from 20 to 42 weeks. Compared with the general population, significant deviations in multiples of the median values of UA-PI, MCA-PI and CPR were observed in subgroups of maternal age, body mass index, racial origin, method of conception and parity.
Watch out: Reference ranges, not normal ranges — the all-comers composition (maternal disease and pregnancy complications included) is the price of the cohort's size and prints on the face. The record prints shapes and peak timings, not a numeric centile table, and none is taken from it.
Source: Ciobanu A et al. Fetal Medicine Foundation reference ranges for umbilical artery and middle cerebral artery pulsatility index and cerebroplacental ratio. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2019. PMID: 30353583. Registry ID: none in the record. MeSH: Adult · Cross-Sectional Studies · Female · Gestational Age · Humans · Infant, Newborn · Middle Cerebral Artery/diagnostic imaging*,embryology · Pregnancy · Prospective Studies · Pulsatile Flow* · Reference Values · Ultrasonography, Doppler, Color* · Ultrasonography, Prenatal* · Umbilical Arteries/diagnostic imaging*
Card 4 — Quantile-regression nomograms (Rizzo 2022, Journal of Maternal-Fetal & Neonatal Medicine — prospective cross-sectional study of 2,516 low-risk singleton pregnancies at 24–40 weeks): nomograms for uterine, umbilical and middle cerebral artery PI and cerebroplacental ratio; intra- and inter-observer ICCs >0.92 and >0.91; medians matched earlier charts while the distributions around the median differed from them
Study: Reference-range derivation (prospective cross-sectional nomograms)
Population: 2,516 low-risk singleton pregnancies between 24 and 40 weeks of gestation in a prospective cross-sectional study using a standardized methodology and quantile regression.
Summary: Quantile-regression nomograms (Rizzo 2022, Journal of Maternal-Fetal & Neonatal Medicine — prospective cross-sectional study of 2,516 low-risk singleton pregnancies at 24–40 weeks): nomograms for uterine, umbilical and middle cerebral artery PI and cerebroplacental ratio; intra- and inter-observer ICCs >0.92 and >0.91; medians matched earlier charts while the distributions around the median differed from them
Result: There was good intra- and inter-observer agreement for each explored vessel (ICC >0.92 and >0.91 for a single and two observers respectively). The 5th, 10th, 50th, 90th and 95th centiles were constructed by quantile regression; all Doppler indices significantly changed with gestation, with second-degree polynomial models better describing cerebroplacental ratio and MCA PI and a linear model better predicting the other indices. Compared with previously published reference ranges, the new charts showed similar median values but different distribution from the median.
Watch out: The warning in this report is distributional: two charts can share a median and differ in spread, so a centile read off the wrong chart misclassifies even when the median agrees. The record prints no numeric centiles at abstract level and none is taken from it.
Source: Rizzo G et al. Modeling Pulsatility Index nomograms from different maternal and fetal vessels by quantile regression at 24-40 weeks of gestation: a prospective cross-sectional study. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2022. PMID: 35343350. Registry ID: none in the record. MeSH: Cross-Sectional Studies · Female · Gestational Age · Humans · Middle Cerebral Artery/diagnostic imaging · Nomograms* · Placenta · Pregnancy · Prospective Studies · Ultrasonography, Prenatal/methods · Umbilical Arteries*/diagnostic imaging
Card 5 — Synthesis — fetal Doppler reference ranges: 3 independent cohorts in 4 reports (the Acharya pair is one Tromsø cohort of 130 pregnancies in two reports; plus 72,387 FMF pregnancies and 2,516 nomogram pregnancies)
Study: Synthesis
Population: 4 reports, 3 cohorts: the Tromsø longitudinal cohort (130 low-risk pregnancies, 513 observations, reported twice — site-dependence and free-loop indices), the Fetal Medicine Foundation cross-sectional reference study (72,387 pregnancies, all-comers by design), and the Rizzo quantile-regression nomograms (2,516 low-risk pregnancies).
Summary: Synthesis — fetal Doppler reference ranges: 3 independent cohorts in 4 reports (the Acharya pair is one Tromsø cohort of 130 pregnancies in two reports; plus 72,387 FMF pregnancies and 2,516 nomogram pregnancies)
Result: The shapes replicate across three designs on three programmes: umbilical artery PI falls with gestational age (linearly in the FMF data; continuously without plateau or term rise in the longitudinal data), MCA-PI peaks at ~32 weeks and cerebroplacental ratio at ~34 weeks before falling, umbilical values depend on insonation site (higher at the intra-abdominal portion and fetal end than at the placental end), measurement variability is ~7–13% (intraobserver CVs; ICCs >0.91 in the nomogram study), and two charts can share a median while differing in spread. No anchor prints a numeric centile table in its record, so this is a shape-and-method shelf: no centile value may be added from anywhere else. No report was refused. Fetal growth standards (size, not flow) and umbilical cord blood gases are homed on their own shelves — different measurands.
Watch out: PHYSIOLOGY — ESTABLISHED for the shapes, which three designs replicate; the stamp claims directions of travel, peak timings, site-dependence and measurement variability — not centile values, none of which any carded record prints.
Source: Synthesis of the reports carded above; no additional source.