SourceMed · Shelf #8705 in the ask interface
ISTH Bleeding Assessment Tool (ISTH-BAT) — 3 reports: normal ranges from merged data on 1,040 adults and 328 children (abnormal ≥4 men, ≥6 women, ≥3 children), haemophilia-carrier scores 5.7 vs 1.43 in controls, and a median score of 7 in Omani type 1 von Willebrand disease
Shelf #8705 · Critical care & sepsis
MEASUREMENT PROPERTIES — supported for standardised bleeding-symptom assessment, on known-groups and normal-range evidence rather than diagnostic accuracy: abnormal cut-offs of ≥4 (adult males), ≥6 (adult females) and ≥3 (children) from merged Vicenza-family data on 1,040 normal adults and 328 children; haemophilia carriers score 5.7 versus 1.43 in age-matched controls (P<0.0001), between type 3 and type 1 VWD comparators; median score 7 (IQR 2–11) in 48 Omani type 1 VWD patients with 10-minute administration. No sensitivity/specificity pair exists in this base and none is claimed; the normal-range limb is merged across four BAT versions and prints as merged.
Stamped: 2026-11-28.
Evidence published: 2014–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the International Society on Thrombosis and Haemostasis Bleeding Assessment Tool (ISTH-BAT) — its normal range and abnormal cut-offs in adults and children, its scores in haemophilia carriers versus controls and von Willebrand disease comparators, and its scores and administration time in type 1 von Willebrand disease?
Balance of the evidence
3 reports: a merged-data normal-range study, a multinational carrier utility study and a single-country VWD series. NOT counted: the Self-BAT validation (a self-administered variant, prose only). No registry IDs in any record.
MeSH: Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · Child · Child, Preschool · Computational Biology/methods · Female · Hemophilia A/blood,diagnosis · Hemorrhage/blood*,diagnosis*,etiology · Humans · Infant · Male · Middle Aged · Reference Values · Severity of Illness Index · Surveys and Questionnaires · Young Adult · von Willebrand Diseases/blood,diagnosis · Cross-Sectional Studies · Hemophilia A · Hemorrhage/diagnosis* · Prospective Studies · von Willebrand Disease, Type 1/complications* · von Willebrand Factor/analysis
Cards (4)
Card 1 — Normal-range study (Elbatarny 2014, Haemophilia — the Merging Project): merged legacy Vicenza-family BAT data on 1,040 normal adults and 328 children; normal range 0–3 for adult males, 0–5 for adult females and 0–2 for children, giving abnormal cut-offs of ≥4, ≥6 and ≥3 respectively, as published — merged legacy data across four BAT versions, printed as merged, never as ISTH-BAT-only data
Study: Normal-range study (merged legacy data across four BAT versions — printed as merged)
Population: 1,040 normal adults and 328 children whose data were merged from four different (all Vicenza-based) bleeding assessment tools — the MCMDM-1 VWD Bleeding Questionnaire, the Condensed MCMDM-1 VWD BQ, the Pediatric Bleeding Questionnaire and the ISTH-BAT — through the Merging Project bioinformatics system.
Summary: Normal-range study (Elbatarny 2014, Haemophilia — the Merging Project): merged legacy Vicenza-family BAT data on 1,040 normal adults and 328 children; normal range 0–3 for adult males, 0–5 for adult females and 0–2 for children, giving abnormal cut-offs of ≥4, ≥6 and ≥3 respectively, as published — merged legacy data across four BAT versions, printed as merged, never as ISTH-BAT-only data
Result: The normal range of bleeding scores was 0–3 for adult males, 0–5 for adult females and 0–2 in children of both sexes; the cut-off for a positive or abnormal bleeding score is therefore ≥4 in adult males, ≥6 in adult females and ≥3 in children. The authors present these ranges as the reference against which bleeding symptoms can be objectively assessed as normal or abnormal in future studies.
Watch out: The normal ranges rest on merged data from four related instruments, only one of which is the ISTH-BAT itself. No card may present these cut-offs as derived from ISTH-BAT-only administrations.
Source: Elbatarny M et al. Normal range of bleeding scores for the ISTH-BAT: adult and pediatric data from the merging project. Haemophilia : the official journal of the World Federation of Hemophilia. 2014. PMID: 25196510. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · Child · Child, Preschool · Computational Biology/methods · Female · Hemophilia A/blood,diagnosis · Hemorrhage/blood*,diagnosis*,etiology · Humans · Infant · Male · Middle Aged · Reference Values · Severity of Illness Index · Surveys and Questionnaires · Young Adult · von Willebrand Diseases/blood,diagnosis
Card 2 — Haemophilia-carrier utility study (James 2016, Haemophilia — multinational, prospective cross-sectional): 168 haemophilia carriers had mean bleeding score 5.7 versus 1.43 in 46 age-matched controls (P<0.0001), above type 3 VWD comparators (3.0; P=0.009) and below women with type 1 VWD (8.7; P<0.0001); 15 carriers reported haemarthrosis, 6 of them with normal factor levels
Study: Prospective cross-sectional utility study (multinational)
Population: 168 unselected consecutive haemophilia carriers (155 haemophilia A, 13 haemophilia B; mean age 40 years, range 20–82) recruited by the Global Emerging HEmostasis Panel, with 46 age-matched controls and VWD comparator groups (32 type 3 VWD, 83 women with type 1 VWD) as printed in the record.
Summary: Haemophilia-carrier utility study (James 2016, Haemophilia — multinational, prospective cross-sectional): 168 haemophilia carriers had mean bleeding score 5.7 versus 1.43 in 46 age-matched controls (P<0.0001), above type 3 VWD comparators (3.0; P=0.009) and below women with type 1 VWD (8.7; P<0.0001); 15 carriers reported haemarthrosis, 6 of them with normal factor levels
Result: Carriers had higher mean bleeding scores than age-matched controls (5.7 vs 1.43; P<0.0001) and than type 3 VWD comparators (3.0; P=0.009), but lower scores than women with type 1 VWD (8.7; P<0.0001) — an ordering of type 1 VWD > haemophilia carriers > type 3 VWD > controls. Fifteen carriers reported haemarthrosis, six of them with normal factor VIII/IX levels. There was a significant but weak negative correlation between bleeding score and factor level (Spearman's r2 = −0.36 as printed, P<0.001).
Watch out: A known-groups utility study, not a diagnostic-accuracy study: there is no sensitivity/specificity pair in this record and none may be manufactured. The score–factor-level correlation is weak, so the score does not proxy factor level.
Source: James PD et al. Evaluation of the utility of the ISTH-BAT in haemophilia carriers: a multinational study. Haemophilia : the official journal of the World Federation of Hemophilia. 2016. PMID: 27868369. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Female · Hemophilia A · Hemorrhage/diagnosis* · Humans · Middle Aged · Prospective Studies · Young Adult
Card 3 — Omani type 1 VWD series (Pathare 2018, International Journal of Laboratory Hematology): 48 index cases and 52 normal subjects; median bleeding score 7 (IQR 2–11) in cases, individual scores 0–36; median administration time 10 minutes (IQR 8–17), as published
Study: Case series with normal comparators (single-country transport)
Population: 48 Omani patients with type 1 von Willebrand disease (mean age 27 years, range 6–49; 60% female) and 52 normal subjects, interviewed with the ISTH-BAT questionnaire covering bleeding symptoms from 12 sites; laboratory parameters came from medical records.
Summary: Omani type 1 VWD series (Pathare 2018, International Journal of Laboratory Hematology): 48 index cases and 52 normal subjects; median bleeding score 7 (IQR 2–11) in cases, individual scores 0–36; median administration time 10 minutes (IQR 8–17), as published
Result: The median bleeding score in type 1 VWD cases was 7 (IQR 2–11), with individual scores ranging from 0 to 36 — wide overlap in range despite the group separation. The score was negatively correlated with VWF antigen (Spearman rho −0.15), VWF ristocetin cofactor (−0.08) and VWF collagen binding (−0.22); the record's conclusion states the score significantly correlated with VWF antigen and collagen binding. Median administration time was 10 minutes (IQR 8–17).
Watch out: Small, single-country series: the correlations with laboratory parameters are weak (rho −0.08 to −0.22) and print at that weight; the 0–36 individual range in cases shows the score's spread, not a clean separation from normal.
Source: Pathare A et al. Bleeding score in Type 1 von Willebrand disease patients using the ISTH-BAT questionnaire. International journal of laboratory hematology. 2018. PMID: 29115727. Registry ID: none in the record. MeSH: Adolescent · Adult · Child · Female · Hemorrhage/diagnosis* · Humans · Male · Middle Aged · Severity of Illness Index · Surveys and Questionnaires · Young Adult · von Willebrand Disease, Type 1/complications* · von Willebrand Factor/analysis
Card 4 — Synthesis — ISTH-BAT: normal ranges from merged legacy data (1,040 adults + 328 children), carrier utility (168 + 46 controls) and an Omani type 1 VWD series (48 + 52)
Study: Synthesis
Population: 3 reports: Elbatarny 2014 (merged normal-range data), James 2016 (multinational carrier utility) and Pathare 2018 (Omani type 1 VWD). NOT counted: PMID 26179127 (the Self-BAT) — a self-administered variant's validation (ICC 0.87 against the ISTH-BAT; test–retest ICC 0.95), never the parent instrument's evidence, named here in prose only.
Summary: Synthesis — ISTH-BAT: normal ranges from merged legacy data (1,040 adults + 328 children), carrier utility (168 + 46 controls) and an Omani type 1 VWD series (48 + 52)
Result: MEASUREMENT PROPERTIES rests on three distinct limbs that are never merged into an accuracy pair: defined normal ranges and abnormal cut-offs (≥4 adult males, ≥6 adult females, ≥3 children) from merged Vicenza-family data; known-groups separation in the population where the tool is hardest to judge (carriers 5.7 vs controls 1.43); and a transport series showing a median score of 7 in type 1 VWD with 10-minute administration. No sensitivity or specificity for any bleeding disorder is printed anywhere in this base, and none is claimed. No registry IDs in any record.
Watch out: Weakest points, printed: the normal-range limb is merged across four instrument versions, the carrier limb is known-groups only, and the VWD limb is small (48 cases) with weak laboratory correlations.