SourceMed · Shelf #8710 in the ask interface

PECARN cervical-spine injury prediction rule in children after blunt trauma — 4 reports, all from the PECARN programme: sensitivity 94.3% in the validation cohort and 93.3% in the three-rule comparison, falling to 88.5% on EMS-collected observations (single-programme base)

Shelf #8710 · Emergency & first hours

PREDICTIVE PERFORMANCE — the best-performing paediatric rule in its own cohort, on a single-programme base (this weakness prints with the stamp): sensitivity 94.3% in the validation cohort (specificity 60.4%, NPV 99.9%) and 93.3% in the three-rule comparison against the Canadian C-Spine Rule (90.8%) and NEXUS (85.7%), stable at 91.7–94.4% across age groups — with two honest decays: 88.5% when the rule's inputs are EMS clinicians' field observations rather than ED assessments, and specificity of only ~60%, so the projected CT reduction (17.2% to 6.9% of children) is the efficiency limb and prints as a projection, not an observed outcome. Three of four reports re-slice one 22,430-child cohort and there is no non-PECARN validation in this base.

Stamped: 2026-11-28.

Evidence published: 2024–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children presenting to the emergency department after blunt trauma, how accurately does the PECARN cervical-spine injury prediction rule (high-risk factors plus classification-tree factors, embedded in an imaging algorithm) identify cervical spine injury — in its derivation/validation cohorts, head-to-head against the NEXUS criteria and the Canadian C-Spine Rule applied to children, on EMS-collected observations, and across age groups?

Balance of the evidence

4 reports, every one from the PECARN programme: 1 derivation/validation report + 2 same-cohort secondary analyses + 1 independent-observation transport study at the same 18 sites.

MeSH: Humans · Prospective Studies · Child · Emergency Service, Hospital* · Wounds, Nonpenetrating*/diagnostic imaging · Child, Preschool · Female · Cervical Vertebrae*/injuries,diagnostic imaging · Male · Infant · Adolescent · Spinal Injuries*/diagnostic imaging,diagnosis · Clinical Decision Rules* · Infant, Newborn · Algorithms · Tomography, X-Ray Computed · Emergency Service, Hospital · Predictive Value of Tests · Sensitivity and Specificity · Spinal Injuries*/diagnosis,diagnostic imaging · Wounds, Nonpenetrating*/diagnosis,diagnostic imaging · Secondary Data Analysis · Cervical Vertebrae*/injuries · Spinal Injuries*/diagnosis · Emergency Medical Services*/methods · Wounds, Nonpenetrating*/diagnosis · Spinal Injuries*/diagnosis,epidemiology · Age Factors · Risk Factors

Cards (5)

Card 1 — Derivation and validation (Leonard 2024, Lancet Child & Adolescent Health — prospective, 18 PECARN EDs, 22,430 children (11,857 derivation / 10,573 validation), 433 (1.9%) with confirmed cervical spine injury): applied to the validation cohort the rule performed with sensitivity 94.3% (95% CI 90.7–97.9), specificity 60.4% (59.4–61.3) and NPV 99.9% (99.8–100.0), and algorithm application was estimated to reduce CT use from 3,856 (17.2%) to 1,549 (6.9%) of 22,430 children. Registry ID: NCT05049330

Study: Prospective derivation and validation study (programme-labelled — derivation with a split-sample validation, counted as one report)

Population: 22,430 children aged 0–17 years presenting with known or suspected blunt trauma at 18 specialised children's EDs (PECARN), enrolled into derivation (9 EDs, 11,857) or validation (9 EDs, 10,573) cohorts; 433 (1.9%) had confirmed cervical spine injury. High-risk factors were altered mental status (GCS 3–8 or unresponsive), abnormal airway/breathing/circulation and focal neurological deficits; classification-tree factors added neck pain, altered mental status (GCS 9–14 and related signs), substantial head or torso injury and midline neck tenderness.

Summary: Derivation and validation (Leonard 2024, Lancet Child & Adolescent Health — prospective, 18 PECARN EDs, 22,430 children (11,857 derivation / 10,573 validation), 433 (1.9%) with confirmed cervical spine injury): applied to the validation cohort the rule performed with sensitivity 94.3% (95% CI 90.7–97.9), specificity 60.4% (59.4–61.3) and NPV 99.9% (99.8–100.0), and algorithm application was estimated to reduce CT use from 3,856 (17.2%) to 1,549 (6.9%) of 22,430 children. Registry ID: NCT05049330

Result: In the derivation cohort, 118 of 928 children (12.7%) with at least one high-risk factor had cervical spine injury (risk ratio 8.9, 95% CI 7.1–11.2, relative). The combined rule applied to the validation cohort performed with 94.3% sensitivity (95% CI 90.7–97.9), 60.4% specificity (59.4–61.3) and 99.9% negative predictive value (99.8–100.0). Had the algorithm guided imaging in all participants, CT use was estimated to fall from 3,856 (17.2%) to 1,549 (6.9%) of 22,430 children without increasing plain radiographs.

Watch out: Single-programme weakness prints: this is the PECARN programme's own derivation with a split-sample (by-site) validation, and every other report on this shelf re-slices the same programme's data. The CT reduction (17.2% to 6.9%) is a projected estimate from algorithm application, not an observed outcome. The authors themselves call for validation in community EDs.

Source: Leonard JC et al. PECARN prediction rule for cervical spine imaging of children presenting to the emergency department with blunt trauma: a multicentre prospective observational study. The Lancet. Child & adolescent health. 2024. PMID: 38843852. Registry ID: NCT05049330. MeSH: Humans · Prospective Studies · Child · Emergency Service, Hospital* · Wounds, Nonpenetrating*/diagnostic imaging · Child, Preschool · Female · Cervical Vertebrae*/injuries,diagnostic imaging · Male · Infant · Adolescent · Spinal Injuries*/diagnostic imaging,diagnosis · Clinical Decision Rules* · Infant, Newborn · Algorithms · Tomography, X-Ray Computed

Card 2 — Three-rule comparison (Lee 2025, JAMA Network Open — planned secondary analysis of the same 22,430-child cohort): sensitivity PECARN 93.3% (90.9–95.7), Canadian C-Spine Rule 90.8% (88.0–93.5), NEXUS 85.7% (82.4–89.0); NPVs 99.8% / 99.7% / 99.6%; projected CT imaging 6.9% (PECARN) vs 13.2% (CCR) vs 10.8% (NEXUS) — only the PECARN limb is counted here

Study: Planned secondary analysis (shared, same-cohort report, printed as such — only the PECARN limb counted here)

Population: The same 22,430 eligible children (median age 8 years; 433, 1.9%, with cervical spine injury; imaging in 12,768, 56.9%) from the derivation study's 18 PECARN EDs. Shared, same-cohort report, printed as such: the adult-derived rules' paediatric limbs are transport data for instruments homed elsewhere and are cross-pointed, never re-homed.

Summary: Three-rule comparison (Lee 2025, JAMA Network Open — planned secondary analysis of the same 22,430-child cohort): sensitivity PECARN 93.3% (90.9–95.7), Canadian C-Spine Rule 90.8% (88.0–93.5), NEXUS 85.7% (82.4–89.0); NPVs 99.8% / 99.7% / 99.6%; projected CT imaging 6.9% (PECARN) vs 13.2% (CCR) vs 10.8% (NEXUS) — only the PECARN limb is counted here

Result: Sensitivity was 93.3% (95% CI 90.9%–95.7%) for the PECARN rule, 90.8% (88.0%–93.5%) for the Canadian C-Spine Rule and 85.7% (82.4%–89.0%) for NEXUS; negative predictive values were 99.8%, 99.7% and 99.6%. Strict application of each rule gave projected CT imaging of 1,549 children (6.9%) for PECARN, 2,968 (13.2%) for CCR and 2,419 (10.8%) for NEXUS.

Watch out: Same cohort as the derivation card — a comparison, not a validation. The PECARN rule's home-field advantage prints: it was derived on these data, while CCR and NEXUS were derived in adults, so the ordering is partly built into the design.

Source: Lee LK et al. Comparison of Cervical Spine Injury Clinical Prediction Rules for Children After Blunt Trauma. JAMA network open. 2025. PMID: 41632125. Registry ID: none in the record. MeSH: Adolescent · Child · Child, Preschool · Female · Humans · Infant · Male · Cervical Vertebrae*/injuries,diagnostic imaging · Clinical Decision Rules* · Emergency Service, Hospital · Predictive Value of Tests · Prospective Studies · Sensitivity and Specificity · Spinal Injuries*/diagnosis,diagnostic imaging · Wounds, Nonpenetrating*/diagnosis,diagnostic imaging · Secondary Data Analysis

Card 3 — EMS-observation transport (Browne 2025, Journal of Trauma and Acute Care Surgery — prospective multicentre, EMS clinicians completed observation forms for 7,721 children transported to the same 18 PECARN EDs): the rule applied to EMS observations performed with sensitivity 88.5% (95% CI 82.9–94.2), specificity 63.1% (62.0–64.2), NPV 99.7% (99.6–99.9), and algorithm adherence would have reduced spinal motion restriction from 41.5% to 37.7% and longboard use from 17.0% to 9.8%

Study: Prospective transport study (independent observation set, same programme and sites)

Population: 7,721 children younger than 18 years with blunt trauma transported by EMS to one of 18 PECARN EDs, in a convenience sample whose EMS clinicians completed case report forms on cervical-spine risk factors from their field observations (forms completed for 57.4% of patients). A different, prospectively collected observation set: the shelf's one genuinely independent transport, and its weakest sensitivity.

Summary: EMS-observation transport (Browne 2025, Journal of Trauma and Acute Care Surgery — prospective multicentre, EMS clinicians completed observation forms for 7,721 children transported to the same 18 PECARN EDs): the rule applied to EMS observations performed with sensitivity 88.5% (95% CI 82.9–94.2), specificity 63.1% (62.0–64.2), NPV 99.7% (99.6–99.9), and algorithm adherence would have reduced spinal motion restriction from 41.5% to 37.7% and longboard use from 17.0% to 9.8%

Result: Applied to EMS observations the rule had sensitivity 88.5% (95% CI 82.9–94.2%), specificity 63.1% (62.0–64.2%), positive predictive value 3.7% (3.0–4.4%) and negative predictive value 99.7% (99.6–99.9%). Had the algorithm been followed, spinal motion restriction would have fallen from 41.5% to 37.7% and longboard use from 17.0% to 9.8%.

Watch out: The decay is the finding: 94.3% sensitivity on ED assessments becomes 88.5% when the inputs are EMS clinicians' field observations. Even this transport is inside the PECARN programme and its sites — there is no non-PECARN, non-US validation anywhere in this base.

Source: Browne LR et al. Performance of the PECARN cervical spine injury prediction rule based on EMS clinician observations. The journal of trauma and acute care surgery. 2025. PMID: 40836370. Registry ID: none in the record. MeSH: Humans · Cervical Vertebrae*/injuries · Male · Female · Prospective Studies · Child · Spinal Injuries*/diagnosis · Emergency Medical Services*/methods · Wounds, Nonpenetrating*/diagnosis · Child, Preschool · Clinical Decision Rules* · Adolescent · Infant · Predictive Value of Tests

Card 4 — Age-group analysis (Corwin 2026, Pediatrics — planned secondary analysis of the same cohort by age group (<2, 2–7, 8–15, 16–<18 years)): the PECARN rule's sensitivity ranged 91.7–94.4% across age groups with NPVs all ≥99.6%, and age-specific re-derived rules performed no better (sensitivity 88.4–97.5%), as published

Study: Planned secondary analysis (same-cohort report, printed as such)

Population: The same 22,430 participants from the PECARN cervical-spine study at 18 children's hospitals, divided into four age groups (<2, 2–7, 8–15 and 16 to <18 years); age-specific rules were derived from the four high-risk predictors plus classification-tree analysis within each group. Same-cohort report, printed as such.

Summary: Age-group analysis (Corwin 2026, Pediatrics — planned secondary analysis of the same cohort by age group (<2, 2–7, 8–15, 16–<18 years)): the PECARN rule's sensitivity ranged 91.7–94.4% across age groups with NPVs all ≥99.6%, and age-specific re-derived rules performed no better (sensitivity 88.4–97.5%), as published

Result: The PECARN rule's sensitivity ranged 91.7%–94.4% across age groups, similar to the age-specific rules' 88.4%–97.5%; its specificity ranged 44.6%–72.3% against the age-specific rules' 45.9%–75.9%. Negative predictive values (all ≥99.6%) were similar across age groups for all rules. Three to eight risk factors were identified as non-negligible in each age group's tree analysis. The authors conclude the findings support use of the single PECARN rule across the paediatric age spectrum.

Watch out: Same cohort again — this card answers an age-transport question inside one dataset, not an external one. The specificity range (44.6–72.3% by age) is wide and prints; the youngest group is where a single rule is most strained, and no age-specific rule rescued it.

Source: Corwin DJ et al. Comparison of Cervical Spine Injury Prediction Rule Across Ages. Pediatrics. 2026. PMID: 42061904. Registry ID: none in the record. MeSH: Humans · Cervical Vertebrae*/injuries · Adolescent · Child · Female · Child, Preschool · Male · Spinal Injuries*/diagnosis,epidemiology · Age Factors · Clinical Decision Rules* · Predictive Value of Tests · Wounds, Nonpenetrating*/diagnosis · Risk Factors · Infant · Sensitivity and Specificity · Emergency Service, Hospital

Card 5 — Synthesis — PECARN cervical-spine rule: 1 derivation/validation report + 2 same-cohort secondary analyses + 1 independent-observation transport — every report is from the PECARN programme and three of four re-slice a single cohort (single-programme weakness, printed)

Study: Synthesis

Population: 4 reports: Leonard 2024 (derivation/validation, 22,430 children, 433 injuries), Lee 2025 (same-cohort three-rule comparison), Browne 2025 (EMS-observation transport, 7,721) and Corwin 2026 (same-cohort age-group analysis). There is no non-PECARN, non-US validation in this base and the face says so in those terms.

Summary: Synthesis — PECARN cervical-spine rule: 1 derivation/validation report + 2 same-cohort secondary analyses + 1 independent-observation transport — every report is from the PECARN programme and three of four re-slice a single cohort (single-programme weakness, printed)

Result: The rule is the best-performing paediatric rule in its own cohort (validation sensitivity 94.3%, three-rule comparison 93.3%, NPV 99.8–99.9% throughout, stable 91.7–94.4% across age groups), with two honest decays: 88.5% when its inputs are EMS field observations rather than ED assessments, and specificity of only ~60% — the projected CT reduction (17.2% to 6.9%) is a projection, not an observed outcome. Cervical spine injury prevalence was 1.9%, so the near-perfect NPVs are substantially prevalence-carried and print beside the sensitivities. Cross-points in prose only: the adult cervical-spine homes (NEXUS and the Canadian C-Spine Rule packs) — different populations; their paediatric limbs enter this shelf only as the comparison report's cross-pointed limbs. One databank registry ID in the base (NCT05049330, derivation record).

Watch out: Weakest pack in this builder's set by independence: a new (2024), large and otherwise unhomed rule whose entire evidence base is one programme's — the stamp is a performance statement about that base, not about transport beyond it. The derivation authors' own call for community-ED validation is unmet and is part of the shelf's honest content.

Source: Synthesis of the reports carded above; no additional source.