SourceMed · Shelf #8713 in the ask interface

Ottawa Heart Failure Risk Scale — 3 reports, all from the developing programme (derivation 559 visits; explicit validation 1,100 patients; the successor HEARTRISK6 re-derived on the pooled 2,246): a >1 admission threshold raised sensitivity for serious adverse events from practice's 71.8% to 91.8% (95.8% with NT-proBNP) while raising admissions from 57.2% to 77.6% (88.0% with NT-proBNP)

Shelf #8713 · Emergency & first hours

PREDICTIVE PERFORMANCE — a sensitive disposition aid whose cost is admissions: the derivation risk gradient ran 2.8% to 89.0% across the scale, and on explicit validation a >1 admission threshold raised sensitivity for serious adverse events from actual practice's 71.8% to 91.8% (95.8% with NT-proBNP) while raising admissions from 57.2% to 77.6% (88.0% with NT-proBNP). Every report is the developing programme's, and the successor scale is re-derived on substantially the same patients — there is no independent-group validation of either scale in this base, and that single-programme weakness prints with the stamp.

Stamped: 2026-11-28.

Evidence published: 2013–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In emergency-department patients with acute heart failure, how well does the Ottawa Heart Failure Risk Scale (10 clinical elements) stratify the risk of serious adverse events after the ED visit — at derivation, on prospective explicit validation (with and without quantitative NT-proBNP), and in its pooled re-derivation as the six-item HEARTRISK6 scale?

Balance of the evidence

3 reports, all from one programme (Stiell and colleagues): the derivation cohort (559 visits, 6 Canadian EDs), the programme's own prospective explicit validation (1,100 patients, 6 tertiary EDs), and the HEARTRISK6 successor scale derived by pooling those two cohorts with one new 587-patient cohort (2,246 patients total) — the third report re-uses the first two's patients and is not an independent validation of the OHFRS, and its figures belong to the new scale. No report from any independent group is in this base. The outcome (serious adverse events) is partly disposition-contingent — monitored-unit admission and relapse admission are themselves decisions — which is printed as a caveat on every card. Cross-points in prose only: the heart-failure neighbours in the library are treatment questions and the general early-warning instruments NEWS2 (pack #7542) and MEWS (pack #7824) — different instruments and populations.

MeSH: Aged · Aged, 80 and over · Analysis of Variance · Cause of Death* · Cohort Studies · Disease Progression · Emergency Medicine/standards,trends · Emergency Service, Hospital/statistics & numerical data* · Emergency Treatment/adverse effects*,methods · Female · Heart Failure/diagnosis,mortality*,therapy* · Hospital Mortality/trends · Humans · Logistic Models · Male · Multivariate Analysis · Odds Ratio · Patient Admission/statistics & numerical data · Patient Discharge/statistics & numerical data* · Retrospective Studies · Risk Assessment · Severity of Illness Index · Survival Rate · Time Factors · Acute Disease · Biomarkers/blood · Decision Support Techniques* · Emergency Service, Hospital · Heart Failure/diagnosis* · Hospitalization/statistics & numerical data* · Middle Aged · Natriuretic Peptide, Brain/blood* · Peptide Fragments/blood* · Prognosis · Prospective Studies · Risk Assessment* · Sensitivity and Specificity

Cards (4)

Card 1 — Derivation (Stiell 2013, Academic Emergency Medicine — prospective cohort, 6 Canadian EDs, 559 visits): serious adverse events in 65 (11.6%), with 47.7% of events in patients not initially admitted; the 10-element scale's risk ranged 2.8% to 89.0% with good calibration, internal bootstrap validation only; admission thresholds of 1, 2 or 3 points would have given sensitivities of 95.2%, 80.6% and 64.5% — programme-labelled: the scale's own derivation, with no external validation in this report

Study: Derivation study (prospective cohort; programme report)

Population: 559 visits by adult patients presenting with acute decompensated heart failure at six large Canadian EDs; 38.1% of visits resulted in admission. Serious adverse events were defined as death, intubation, admission to a monitored unit, or relapse requiring admission.

Summary: Derivation (Stiell 2013, Academic Emergency Medicine — prospective cohort, 6 Canadian EDs, 559 visits): serious adverse events in 65 (11.6%), with 47.7% of events in patients not initially admitted; the 10-element scale's risk ranged 2.8% to 89.0% with good calibration, internal bootstrap validation only; admission thresholds of 1, 2 or 3 points would have given sensitivities of 95.2%, 80.6% and 64.5% — programme-labelled: the scale's own derivation, with no external validation in this report

Result: Of 65 (11.6%) serious adverse event cases, 31 (47.7%) occurred in patients not initially admitted. The multivariate model and resultant Ottawa Heart Failure Risk Scale consists of 10 elements, and the risk of serious adverse events varied from 2.8% to 89.0%, with good calibration between observed and expected probabilities. Internal validation showed the risk scores to be very accurate across 1,000 replications using the bootstrap method. A threshold of 1, 2, or 3 total scores for admission would be associated with sensitivities of 95.2, 80.6, or 64.5%, respectively, all better than current practice.

Watch out: Internal (bootstrap) validation only — the 2.8%-to-89.0% gradient and the threshold sensitivities are the developers' figures on their own derivation data. The outcome is partly disposition-contingent (monitored-unit admission and relapse admission are decisions, not only events), which can flatter a disposition tool.

Source: Stiell IG et al. A risk scoring system to identify emergency department patients with heart failure at high risk for serious adverse events. Academic emergency medicine : official journal of the Society for Academic Emergency Medicine. 2013. PMID: 23570474. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Analysis of Variance · Cause of Death* · Cohort Studies · Disease Progression · Emergency Medicine/standards,trends · Emergency Service, Hospital/statistics & numerical data* · Emergency Treatment/adverse effects*,methods · Female · Heart Failure/diagnosis,mortality*,therapy* · Hospital Mortality/trends · Humans · Logistic Models · Male · Multivariate Analysis · Odds Ratio · Patient Admission/statistics & numerical data · Patient Discharge/statistics & numerical data* · Retrospective Studies · Risk Assessment · Severity of Illness Index · Survival Rate · Time Factors

Card 2 — Prospective explicit validation (Stiell 2017, Academic Emergency Medicine — prospective observational cohort, 6 tertiary EDs, 1,100 patients, mean age 77.7): serious adverse events in 170 (15.5%); against actual practice, an OHFRS >1 threshold would have raised sensitivity from 71.8% to 91.8% and admissions from 57.2% to 77.6%; in the 684 patients with NT-proBNP, sensitivity 95.8% with admissions of 88.0% — programme-labelled: the developers' own validation

Study: Validation study (prospective, explicit; programme report)

Population: 1,100 patients with acute heart failure evaluated by ED physicians for the 10 OHFRS criteria at six tertiary hospital EDs and followed for 30 days; quantitative NT-proBNP was measured in 684. Serious adverse event was defined as death within 30 days, admission to a monitored unit, intubation, noninvasive ventilation, myocardial infarction, or relapse resulting in hospital admission within 14 days.

Summary: Prospective explicit validation (Stiell 2017, Academic Emergency Medicine — prospective observational cohort, 6 tertiary EDs, 1,100 patients, mean age 77.7): serious adverse events in 170 (15.5%); against actual practice, an OHFRS >1 threshold would have raised sensitivity from 71.8% to 91.8% and admissions from 57.2% to 77.6%; in the 684 patients with NT-proBNP, sensitivity 95.8% with admissions of 88.0% — programme-labelled: the developers' own validation

Result: Serious adverse events occurred in 170 (15.5%) cases (19.4% if admitted and 10.2% if discharged). Compared to actual practice, using an admission threshold of OHFRS score > 1 would have increased sensitivity (71.8% vs. 91.8%) but increased admissions (57.2% vs. 77.6%). For the 684 cases with NT-proBNP values, using a threshold score > 1 would have significantly increased sensitivity (69.8% vs. 95.8%) while increasing admissions (60.8% vs. 88.0%). In only 11.9% of cases did physicians indicate discomfort with use of the OHFRS.

Watch out: The sensitivity gain is bought with a 20-point admission increase, and the NT-proBNP limb's 88.0% admission rate approaches admit-almost-everyone — the trade-off, not the sensitivity, is the clinically operative figure. This is still the developing programme validating its own scale; no independent group has validated it in this base.

Source: Stiell IG et al. Prospective and Explicit Clinical Validation of the Ottawa Heart Failure Risk Scale, With and Without Use of Quantitative NT-proBNP. Academic emergency medicine : official journal of the Society for Academic Emergency Medicine. 2017. PMID: 27976497. Registry ID: none in the record. MeSH: Acute Disease · Aged · Aged, 80 and over · Biomarkers/blood · Decision Support Techniques* · Emergency Service, Hospital · Female · Heart Failure/diagnosis* · Hospitalization/statistics & numerical data* · Humans · Male · Middle Aged · Natriuretic Peptide, Brain/blood* · Peptide Fragments/blood* · Prognosis · Prospective Studies · Risk Assessment* · Sensitivity and Specificity

Card 3 — Successor-scale re-derivation (Stiell 2024, JACC: Advances — pooled derivation of the six-item HEARTRISK6 scale from 3 prospective cohorts totalling 2,246 patients: the 559-visit and 1,100-patient cohorts above plus one new 587-patient cohort): 281 (12.5%) short-term serious outcomes including 70 deaths (3.1%); at thresholds ≥1 and ≥2, sensitivities 88.3% (83.9–91.8) / 71.5% (65.9–76.7) and specificities 24.7% (22.8–26.7) / 50.1% (47.9–52.4) — same-programme re-derivation on overlapping data, printed as such: not an independent validation of the OHFRS, and its figures belong to the new scale

Study: Derivation study (pooled re-derivation of a successor scale; programme report)

Population: 2,246 patients pooled from 3 prospective cohorts (N = 559; 1,100; 587) of patients who required treatment for acute heart failure at 10 tertiary care hospital EDs; mean age 77.4 years, 54.5% male, 48.6% admitted. The primary outcome was short-term serious outcome: death <30 days, intubation or noninvasive ventilation, myocardial infarction, or relapse to ED <14 days.

Summary: Successor-scale re-derivation (Stiell 2024, JACC: Advances — pooled derivation of the six-item HEARTRISK6 scale from 3 prospective cohorts totalling 2,246 patients: the 559-visit and 1,100-patient cohorts above plus one new 587-patient cohort): 281 (12.5%) short-term serious outcomes including 70 deaths (3.1%); at thresholds ≥1 and ≥2, sensitivities 88.3% (83.9–91.8) / 71.5% (65.9–76.7) and specificities 24.7% (22.8–26.7) / 50.1% (47.9–52.4) — same-programme re-derivation on overlapping data, printed as such: not an independent validation of the OHFRS, and its figures belong to the new scale

Result: There were 281 (12.5%) short-term serious outcomes including 70 deaths (3.1%), with many in discharged patients. The final HEARTRISK6 Scale included 6 variables: valvular heart disease, tachycardia, need for noninvasive ventilation, creatinine, troponin, and failed reassessment (walk test). Choosing HEARTRISK6 total-point admission thresholds of ≥1 or ≥2 would yield, respectively, sensitivities of 88.3% (95% CI: 83.9%-91.8%) and 71.5% (95% CI: 65.9%-76.7%) and specificities of 24.7% (95% CI: 22.8%-26.7%) and 50.1% (95% CI: 47.9%-52.4%) for short-term serious outcomes.

Watch out: Two of the three pooled cohorts are the OHFRS derivation and validation cohorts carded above — this report cannot corroborate them. Its outcome definition also differs slightly from the earlier reports' (relapse to ED <14 days rather than relapse requiring admission), so its sensitivities are not directly comparable with the OHFRS figures.

Source: Stiell IG et al. The HEARTRISK6 Scale: Predicting Short-Term Serious Outcomes in Emergency Department Acute Heart Failure Patients. JACC. Advances. 2024. PMID: 39129980. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis — Ottawa Heart Failure Risk Scale: 3 reports, all from the developing programme, with the third re-using the first two's cohorts; no independent-group validation exists in this base

Study: Synthesis

Population: 3 reports: derivation (Stiell 2013, 559 visits), prospective explicit validation (Stiell 2017, 1,100 patients, 684 with NT-proBNP), and the HEARTRISK6 successor derivation (Stiell 2024, 2,246 pooled patients of whom 1,659 are the first two cohorts' patients plus 587 new).

Summary: Synthesis — Ottawa Heart Failure Risk Scale: 3 reports, all from the developing programme, with the third re-using the first two's cohorts; no independent-group validation exists in this base

Result: The scale stratifies risk across a wide gradient (2.8% to 89.0% at derivation) and, applied at a >1 threshold in the programme's own validation, would have caught substantially more serious adverse events than actual practice (sensitivity 91.8% vs 71.8%; 95.8% with NT-proBNP) — at the price of admitting 77.6% rather than 57.2% of patients (88.0% with NT-proBNP). The six-item successor, re-derived on substantially the same patients, trades some of that sensitivity back (88.3% at ≥1) for a usable specificity gradient. No report was refused on this row; the composition's weakness is independence, not size: every figure comes from the scale's own developers, and the outcome is partly disposition-contingent in all three reports. Cross-points in prose only: NEWS2 (pack #7542) and MEWS (pack #7824) are general early-warning instruments, not heart-failure disposition scales.

Watch out: PREDICTIVE PERFORMANCE is justified as a within-programme finding: sensitive, at a steep admission price. The stamp carries the single-programme weakness on its face — until an independent group validates either scale, the 91.8%/95.8% sensitivities should be read as the developers' best case, not as transported performance.

Source: Synthesis of the reports carded above; no additional source.