SourceMed · Shelf #8722 in the ask interface

WISCI and WISCI II (Walking Index for Spinal Cord Injury) — 3 reports, split by version: the original 19-item WISCI's international construction study (expert concordance W = 0.843–0.860; 100% inter-rater agreement on 40 videotaped clips) and two WISCI II reports from one Swiss/European programme — validity against timed walking tests (moderate overall, |r| > .60, collapsing to |r| < .35 in poor walkers) and responsiveness (the WISCI II missed change between 3 and 6 months that the timed tests caught)

Shelf #8722 · Brain, stroke & mind

MEASUREMENT PROPERTIES — SPLIT by property: ranking and rating are solid, responsiveness is not — expert concordance and video inter-rater agreement are near-ceiling at construction (W = 0.843–0.860; 100% agreement), but the revised scale correlates only moderately with timed walking (|r| > .60), decouples from it in poor walkers (|r| < .35), and missed change between 3 and 6 months that the 10-metre and 6-minute walk tests caught. The composition mixes versions by design and prints them apart: original-WISCI construction evidence (2000) and WISCI II transport evidence (2005–2006, both from one Swiss/European programme).

Stamped: 2026-11-28.

Evidence published: 2000–2006.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the Walking Index for Spinal Cord Injury (a hierarchical rank-ordered scale of walking capacity in SCI, graded by devices, braces and physical assistance) — the original 19-item WISCI at its international construction and reliability study, and the revised WISCI II for validity against timed walking tests and for responsiveness in incomplete SCI?

Balance of the evidence

3 reports, split by version — the split is the composition: the 2000 international study (Ditunno; eight SCI centres in seven countries) validates the original 19-item WISCI, while both van Hedel reports (2005 validity in 75 patients, reliability in 22; 2006 responsiveness in 22 subjects with incomplete SCI) measure the revised WISCI II. No figure from a WISCI II report is printed as the original scale's evidence, and vice versa. TYPE-FLAGs print on their cards: the 2000 record is typed 'Clinical Trial' for a Delphi construction and reliability study, and the 2006 record is typed 'Controlled Clinical Trial' for a prospective longitudinal study; both are counted on substance. The timed-test limbs of the van Hedel reports (TUG, 10MWT, 6MWT performance) are comparators and are counted nowhere here. Cross-point in prose only: the SCIM pack (#8370) is a different instrument (independence, not walking capacity).

MeSH: Australia · Brazil · Canada · Consensus Statements as Topic · Humans · Italy · Korea · Observer Variation · Orthotic Devices/classification,standards · Pilot Projects · Reproducibility of Results · Spinal Cord Injuries/classification*,rehabilitation* · Statistics, Nonparametric · Trauma Severity Indices* · United Kingdom · United States · Videotape Recording · Walking/standards* · Adolescent · Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Female · Health Status Indicators · Male · Middle Aged · Spinal Cord Injuries/physiopathology,rehabilitation* · Task Performance and Analysis · Walking · Gait Disorders, Neurologic/classification,diagnosis*,etiology,rehabilitation · Outcome Assessment, Health Care/methods* · Recovery of Function* · Sensitivity and Specificity · Severity of Illness Index* · Spinal Cord Injuries/classification,complications,diagnosis*,rehabilitation · Task Performance and Analysis* · Treatment Outcome · Walking*

Cards (4)

Card 1 — International construction study, original WISCI (Ditunno 2000, Spinal Cord — items built by experts at Italian and US centres and blindly rank-ordered at eight SCI centres in seven countries): Kendall concordance for the pilot ranking W = 0.843 (P < 0.001) and for the international blind ranking W = 0.860 (P < 0.001); concurrent comparison with the FIM gave Spearman 0.765 (P < 0.001); inter-rater reliability on 40 videotaped walking clips showed 100% agreement; the final consensus was a 19-item hierarchical scale — programme-labelled: the developers' own study. TYPE-FLAG: typed 'Clinical Trial' at PubMed for a Delphi construction and reliability study; counted on substance. The authors state responsiveness still needed clinical assessment, and that prints

Study: Construction and reliability study (original WISCI) — TYPE-FLAG: typed 'Clinical Trial' in the record for a Delphi construction study; counted on substance

Population: Experts at eight SCI centers in Canada (2), Australia, Brazil, Korea, Italy, the UK and the US: experts at two centers (Italy and the US) constructed the original items and ranked them blindly in hierarchical order (pilot data); all eight centers then completed independent blind rank ordering (24 individuals and eight teams); data on inter-rater reliability came from a videotape of 40 clips showing patients walking, forwarded to all eight centers.

Summary: International construction study, original WISCI (Ditunno 2000, Spinal Cord — items built by experts at Italian and US centres and blindly rank-ordered at eight SCI centres in seven countries): Kendall concordance for the pilot ranking W = 0.843 (P < 0.001) and for the international blind ranking W = 0.860 (P < 0.001); concurrent comparison with the FIM gave Spearman 0.765 (P < 0.001); inter-rater reliability on 40 videotaped walking clips showed 100% agreement; the final consensus was a 19-item hierarchical scale — programme-labelled: the developers' own study. TYPE-FLAG: typed 'Clinical Trial' at PubMed for a Delphi construction and reliability study; counted on substance. The authors state responsiveness still needed clinical assessment, and that prints

Result: For the pilot data, Kendall coefficient of concordance reached significance (W=0.843, P<0.001), showing that experts agreed when rank ordering the original items. Comparison with the FIM (Spearman's rank correlation coefficient=0.765, P<0.001) pointed to a theoretical relationship, yet each scale measures something practically different. Significance also held for Kendall coefficient of concordance in the international blind hierarchical ranking (W=0.860, P<0.001), showing rank ordering agreement across all eight centers. The consensus meeting finalised the scale as the 'Walking Index for Spinal Cord Injury (WISCI)': a 19 item hierarchy with items rank ordered. All centers scored the same 40 videotaped walks and assigned identical levels to them: 100% agreement. The WISCI, the authors conclude, showed good validity and reliability, but its responsiveness still has to be assessed in clinical settings.

Watch out: What is validated here is the ordering — that experts agree which walking level is above which, and that raters assign the same level to the same videotaped walk. Perfect agreement on 40 curated video clips is a ceiling-friendly test, and the scale's behaviour in live clinical assessment, and its responsiveness, were explicitly left untested by this report. This card's evidence belongs to the original 19-item WISCI only.

Source: Ditunno JF et al. Walking index for spinal cord injury (WISCI): an international multicenter validity and reliability study. Spinal cord. 2000. PMID: 10822394. Registry ID: none in the record. MeSH: Australia · Brazil · Canada · Consensus Statements as Topic · Humans · Italy · Korea · Observer Variation · Orthotic Devices/classification,standards · Pilot Projects · Reproducibility of Results · Spinal Cord Injuries/classification*,rehabilitation* · Statistics, Nonparametric · Trauma Severity Indices* · United Kingdom · United States · Videotape Recording · Walking/standards*

Card 2 — WISCI II validity against timed tests (van Hedel 2005, Archives of Physical Medicine and Rehabilitation — typed Validation Study; validity data in 75 patients with SCI and reliability in 22): the three timed tests (TUG, 10MWT, 6MWT) correlated excellently with each other (|r| > .88) but only moderately with the WISCI II (|r| > .60), and in patients with poor walking ability the timed tests stayed highly correlated (|r| > .70) while their correlation with WISCI II fell to |r| < .35 — shared report, printed as shared: the timed-test limbs are counted nowhere here; the WISCI II limb is the revised version's evidence, and its poor-walker collapse prints at full weight

Study: Validation study (WISCI II limb of a shared three-test report)

Population: Patients with spinal cord injury at the SCI center of a university hospital in Switzerland: validity assessed using data of 75 patients with SCI, and reliability determined with 22 patients with SCI. Patients performed the timed tests and the Walking Index for Spinal Cord Injury II (WISCI II) on the same day; three measurements within 7 days were taken to assess reliability.

Summary: WISCI II validity against timed tests (van Hedel 2005, Archives of Physical Medicine and Rehabilitation — typed Validation Study; validity data in 75 patients with SCI and reliability in 22): the three timed tests (TUG, 10MWT, 6MWT) correlated excellently with each other (|r| > .88) but only moderately with the WISCI II (|r| > .60), and in patients with poor walking ability the timed tests stayed highly correlated (|r| > .70) while their correlation with WISCI II fell to |r| < .35 — shared report, printed as shared: the timed-test limbs are counted nowhere here; the WISCI II limb is the revised version's evidence, and its poor-walker collapse prints at full weight

Result: Overall, correlation of the 3 timed walking tests was excellent with each other (| r |>.88) and moderate with the WISCI II (| r |>.60). The correlation between the timed tests for patients with poor walking ability remained high (| r |>.70) but decreased in WISCI II (| r |<.35). High correlation coefficients ( r >.97) were found for intra- and interrater reliability of the timed tests. However, TUG and 10MWT reliability were negatively influenced by a poor walking function. The authors conclude the 3 timed tests are valid and reliable measures for assessing walking function in patients with SCI.

Watch out: This report's purpose was validating the timed tests, and the WISCI II enters as their comparator — its moderate correlations are partly a construct difference (an ordinal capacity grade vs continuous speed/endurance measures), not pure measurement failure. But the poor-walker collapse (|r| < .35) is a real boundary: exactly where walking is worst, the grade and the timed performance stop tracking each other.

Source: van Hedel HJ et al. Assessing walking ability in subjects with spinal cord injury: validity and reliability of 3 walking tests. Archives of physical medicine and rehabilitation. 2005. PMID: 15706542. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Female · Health Status Indicators · Humans · Male · Middle Aged · Reproducibility of Results · Spinal Cord Injuries/physiopathology,rehabilitation* · Task Performance and Analysis · Walking

Card 3 — WISCI II responsiveness (van Hedel 2006, Spinal Cord — prospective longitudinal study in the European Multicenter Study of SCI; 22 subjects with incomplete SCI who achieved functional ambulation, tested at 3, 6 and 12 months): all tests detected improvement in the first 3 months, but between 3 and 6 months only the 10MWT and 6MWT remained responsive — the WISCI II did not; correlations between tests were good within the first month and became poorer over time — the negative responsiveness limb prints at headline weight. TYPE-FLAG: typed 'Controlled Clinical Trial' at PubMed for this longitudinal study; counted on substance

Study: Responsiveness study (prospective longitudinal; WISCI II) — TYPE-FLAG: typed 'Controlled Clinical Trial' in the record for a longitudinal study; counted on substance

Population: 22 subjects with incomplete spinal cord injury (iSCI) who achieved functional ambulation and could stand or walk within 1 month after injury, in the European Multicenter Study of Human Spinal Cord Injury; the walking tests (WISCI II, 6-minute walk test, 10-meter walk test) were analyzed at 3, 6 and 12 months after injury, with responsiveness assessed by differences between time intervals and validity against the lower extremity motor score (LEMS).

Summary: WISCI II responsiveness (van Hedel 2006, Spinal Cord — prospective longitudinal study in the European Multicenter Study of SCI; 22 subjects with incomplete SCI who achieved functional ambulation, tested at 3, 6 and 12 months): all tests detected improvement in the first 3 months, but between 3 and 6 months only the 10MWT and 6MWT remained responsive — the WISCI II did not; correlations between tests were good within the first month and became poorer over time — the negative responsiveness limb prints at headline weight. TYPE-FLAG: typed 'Controlled Clinical Trial' at PubMed for this longitudinal study; counted on substance

Result: All walking tests were able to assess the improvement of walking capacity within the first 3 months after injury. Between 3 and 6 months, only the 10MWT and 6MWT were responsive to the ongoing improvement in locomotor capacity. Overall, correlations between the tests were good within the first month, but became poorer over time. The authors conclude the 6MWT and 10MWT were more responsive in demonstrating an improvement in walking capacity compared to the WISCI II, and recommend the additional use of timed tests to monitor improvement in locomotor capacity in iSCI subjects with walking ability.

Watch out: Only 22 subjects, all selected for having achieved functional ambulation — a coarse ordinal grade has few steps left to climb in exactly this recovering subgroup, so part of the non-responsiveness is ceiling mechanics. It remains the only responsiveness evidence in this base, it is negative after month 3, and the original scale's authors had already flagged responsiveness as the untested property.

Source: van Hedel HJ et al. Improving walking assessment in subjects with an incomplete spinal cord injury: responsiveness. Spinal cord. 2006. PMID: 16304565. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Female · Gait Disorders, Neurologic/classification,diagnosis*,etiology,rehabilitation · Humans · Male · Middle Aged · Outcome Assessment, Health Care/methods* · Recovery of Function* · Reproducibility of Results · Sensitivity and Specificity · Severity of Illness Index* · Spinal Cord Injuries/classification,complications,diagnosis*,rehabilitation · Task Performance and Analysis* · Treatment Outcome · Walking*

Card 4 — Synthesis — WISCI / WISCI II: near-ceiling construction evidence for the original scale; moderate validity and failed mid-course responsiveness for the revised scale; versions printed apart throughout

Study: Synthesis

Population: 3 reports: the international construction study of the original 19-item WISCI (Ditunno 2000; eight centres, 40 videotaped clips), the WISCI II validity study (van Hedel 2005; 75 patients for validity, 22 for reliability) and the WISCI II responsiveness study (van Hedel 2006; 22 subjects with incomplete SCI) — the two WISCI II reports are from one Swiss/European programme.

Summary: Synthesis — WISCI / WISCI II: near-ceiling construction evidence for the original scale; moderate validity and failed mid-course responsiveness for the revised scale; versions printed apart throughout

Result: The original scale's ordering and rating are as solid as construction evidence gets (concordance W = 0.843–0.860 across independent expert groups; 100% inter-rater agreement on video). The revised scale's transport evidence is weaker and partly negative: moderate correlation with timed walking overall (|r| > .60), decoupling in poor walkers (|r| < .35), and no responsiveness between 3 and 6 months where both timed tests responded. No report was refused on this row; the version split is honoured on every card — no WISCI II figure is printed as the original scale's evidence or vice versa. Cross-point in prose only: SCIM (pack #8370) measures independence, a different construct; the timed walking tests' own measurement homes, where they exist, are separate questions and their limbs in these reports are counted nowhere here.

Watch out: MEASUREMENT PROPERTIES — SPLIT by property is the honest stamp: a scale can be a reliable rank-order of walking capacity and still be the wrong instrument for tracking recovery, and this base shows both halves. Any use of WISCI II as a trial endpoint for change over time outruns its evidence; the developers of the timed-test comparison recommend pairing it with timed tests.