SourceMed · Shelf #8723 in the ask interface

GRASSP (Graded Redefined Assessment of Strength, Sensibility and Prehension) — 4 reports, all from the instrument's own programme (two companion 2012 reports, a responsiveness study and the Version 2 Rasch study): reliability 0.84–0.98 and roughly 50% greater sensitivity than the ISNCSCI, with no fully independent validation in the base

Shelf #8723 · Brain, stroke & mind

MEASUREMENT PROPERTIES — supported as the more sensitive upper-limb impairment measure in tetraplegia, on a single-programme base — all four reports are the GRASSP programme's own (the two 2012 papers are companion reports whose identical reliability ranges, inter-rater 0.84–0.96 and test–retest 0.86–0.98, are one programme's finding, never two independent replications); the sensitivity claim is relative to the ISNCSCI examination, not to a functional gold standard; the interval-level property belongs to the Rasch-modified Version 2, not the original form; no fully independent validation is in this composition.

Stamped: 2026-11-28.

Evidence published: 2012–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the GRASSP (the multimodal upper-limb impairment measure for tetraplegia — dorsal and palmar sensation, strength in 10 muscles, and qualitative and quantitative prehension, five subtests per limb) — at its international development, in its reliability and validity study, for responsiveness against the ISNCSCI and SCIM III, and in its Rasch-refined Version 2?

Balance of the evidence

4 reports, all from the GRASSP development programme: a development report and a reliability/validity report published the same year (2012, companion reports with identical reliability ranges), a longitudinal responsiveness report (2016; its record prints no sample size) and a Rasch study deriving Version 2 (2018). Documented samples are 72 individuals with tetraplegia (reliability/validity) and 77 with cervical spinal cord injury (Version 2); the development and responsiveness records print no N and none is borrowed. Cross-point in prose only: the Spinal Cord Independence Measure (SCIM) is a different instrument (independence, not impairment) homed at pack #8370; the SCIM and CUE limbs inside these reports are comparators counted nowhere here. Version discipline: the responsiveness study measures Version 1.0 and the Rasch study's interval property belongs to the modified Version 2; neither is printed as the other's evidence.

MeSH: Activities of Daily Living · Disability Evaluation* · Hand Strength/physiology* · Humans · Muscle Strength/physiology* · Psychometrics · Quadriplegia/etiology,physiopathology,rehabilitation* · Reproducibility of Results · Spinal Cord Injuries/complications,physiopathology,rehabilitation* · Upper Extremity/physiopathology · Adolescent · Adult · Aged · Cross-Sectional Studies · Female · Male · Middle Aged · Quadriplegia/etiology,physiopathology* · Sensitivity and Specificity · Spinal Cord Injuries/complications,physiopathology* · Upper Extremity/physiopathology* · Young Adult · Aged, 80 and over · Longitudinal Studies · Outcome Assessment, Health Care/methods*,standards · Psychometrics/instrumentation* · Spinal Cord Injuries/therapy* · Cervical Vertebrae · Cohort Studies · Muscle Strength/physiology · Prospective Studies · Upper Extremity

Cards (5)

Card 1 — Development study (Kalsi-Ryan 2012, Journal of Neurosurgery: Spine — the International GRASSP Research and Design Team's North American/European multicentre application): inter-rater reliability 0.84–0.96 and test–retest 0.86–0.98 for all subtests, approximately 50% more sensitive than the ISNCSCI in defining sensory and motor integrity; responsiveness was still being tested at publication — the design team's own report, printed as such

Study: Development study (primary report) — programme report

Population: Individuals with complete or incomplete tetraplegia at centres in North America and Europe; the record prints no sample size — N not documented. The GRASSP comprises 5 subtests for each upper limb: dorsal sensation, palmar sensation (tested with Semmes-Weinstein monofilaments), strength (motor grading of 10 muscles), and prehension (qualitative and quantitative grasping).

Summary: Development study (Kalsi-Ryan 2012, Journal of Neurosurgery: Spine — the International GRASSP Research and Design Team's North American/European multicentre application): inter-rater reliability 0.84–0.96 and test–retest 0.86–0.98 for all subtests, approximately 50% more sensitive than the ISNCSCI in defining sensory and motor integrity; responsiveness was still being tested at publication — the design team's own report, printed as such

Result: The established interrater and test-retest reliability for all subtests ranged from 0.84 to 0.96 and from 0.86 to 0.98 respectively. The GRASSP was approximately 50% more sensitive (construct validity) than the International Standards of Neurological Classification of SCI (ISNCSCI) in defining sensory and motor integrity of the upper limb. The subtests showed concurrence with the Spinal Cord Independence Measure (SCIM), SCIM self-care subscales, and Capabilities of Upper Extremity Questionnaire (CUE), the strongest concurrence being with self-perception of function (CUE), 0.57–0.83, p < 0.0001. The authors state responsiveness (follow-up from onset to 1 year postinjury) was currently being tested in international studies.

Watch out: Programme-labelled: the developers' own report, with no sample size in its record. The '50% more sensitive' claim is sensitivity relative to the ISNCSCI neurological examination in defining sensory and motor integrity — not accuracy against a functional gold standard — and responsiveness was untested when this report appeared.

Source: Kalsi-Ryan S et al. Development of the Graded Redefined Assessment of Strength, Sensibility and Prehension (GRASSP): reviewing measurement specific to the upper limb in tetraplegia. Journal of neurosurgery. Spine. 2012. PMID: 22985372. Registry ID: none in the record. MeSH: Activities of Daily Living · Disability Evaluation* · Hand Strength/physiology* · Humans · Muscle Strength/physiology* · Psychometrics · Quadriplegia/etiology,physiopathology,rehabilitation* · Reproducibility of Results · Spinal Cord Injuries/complications,physiopathology,rehabilitation* · Upper Extremity/physiopathology

Card 2 — Reliability and validity study (Kalsi-Ryan 2012, Journal of Neurotrauma — multicentre, typed Validation Study; 72 individuals with tetraplegia): inter-rater and test–retest reliability for all subtests exceeded the hypothesised 0.80 (0.84–0.96 and 0.86–0.98), with the same ~50% sensitivity advantage over the ISNCSCI — a companion report of the development programme, its identical ranges one programme's finding, not an independent replication

Study: Validation study (companion report of the development programme)

Population: 72 individuals with tetraplegia who were neurologically stable, examined by two assessors over a 7-day period; ISNCSCI, CUE and SCIM assessments were also administered.

Summary: Reliability and validity study (Kalsi-Ryan 2012, Journal of Neurotrauma — multicentre, typed Validation Study; 72 individuals with tetraplegia): inter-rater and test–retest reliability for all subtests exceeded the hypothesised 0.80 (0.84–0.96 and 0.86–0.98), with the same ~50% sensitivity advantage over the ISNCSCI — a companion report of the development programme, its identical ranges one programme's finding, not an independent replication

Result: Inter-rater and test-retest reliability for all subtests within the GRASSP were above the hypothesized value of 0.80 (0.84–0.96 and 0.86–0.98, respectively). The GRASSP was about 50% more sensitive (construct validity) than the ISNCSCI when defining sensory and motor integrity of the upper limb; the subtests showed concurrence with the SCIM, SCIM self-care subscale, and CUE, the strongest concurrence to impairment being with self-perception of function (CUE) (0.57–0.83, p<0.0001).

Watch out: Same programme and overlapping property estimates with the development report carded above: the identical reliability ranges must never be summed or cited as two independent replications. The sample was neurologically stable patients — reliability in the acute, changing phase is a different question, addressed only by the programme's own longitudinal report below.

Source: Kalsi-Ryan S et al. The Graded Redefined Assessment of Strength Sensibility and Prehension: reliability and validity. Journal of neurotrauma. 2012. PMID: 21568688. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Cross-Sectional Studies · Disability Evaluation* · Female · Humans · Male · Middle Aged · Quadriplegia/etiology,physiopathology* · Reproducibility of Results · Sensitivity and Specificity · Spinal Cord Injuries/complications,physiopathology* · Upper Extremity/physiopathology* · Young Adult

Card 3 — Responsiveness study (Kalsi-Ryan 2016, Journal of Neurotrauma — multicentre longitudinal observational study of GRASSP Version 1.0, assessments from 0–10 days to 12 months post-injury): standardised response means for GRASSP subtests ranged 0.25 to 0.85 units greater than those for ISNCSCI strength and sensation, SCIM self-care and the CUE-Q, with minimally detectable differences of 2–5 points — the developing group's own responsiveness study; its record prints no sample size

Study: Longitudinal responsiveness study (observational, programme report)

Population: People with acute cervical spinal cord injury assessed at 0–10 days and 1, 3, 6 and 12 months post-injury; the record prints no sample size — N not documented.

Summary: Responsiveness study (Kalsi-Ryan 2016, Journal of Neurotrauma — multicentre longitudinal observational study of GRASSP Version 1.0, assessments from 0–10 days to 12 months post-injury): standardised response means for GRASSP subtests ranged 0.25 to 0.85 units greater than those for ISNCSCI strength and sensation, SCIM self-care and the CUE-Q, with minimally detectable differences of 2–5 points — the developing group's own responsiveness study; its record prints no sample size

Result: Longitudinal construct validity demonstrated GRASSP and all external measures to be responsive to neurological change for 1 year post-injury. Standardized Response Mean values for the GRASSP subtests ranged from 0.25 to 0.85 units greater than that for ISNCSCI strength and sensation, SCIM-SS, and CUE-Q. Minimally detectable difference values for GRASSP subtests ranged from 2–5 points, calculated as the smallest real difference for all subtests.

Watch out: Programme-linked and N-free in its record: the responsiveness advantage is expressed as standardised-response-mean units greater than the comparator measures, as printed — it is not an effect size against a patient-important change standard, and no sample size may be borrowed from the companion reports.

Source: Kalsi-Ryan S et al. Responsiveness, Sensitivity, and Minimally Detectable Difference of the Graded and Redefined Assessment of Strength, Sensibility, and Prehension, Version 1.0. Journal of neurotrauma. 2016. PMID: 26560017. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Female · Humans · Longitudinal Studies · Male · Middle Aged · Outcome Assessment, Health Care/methods*,standards · Psychometrics/instrumentation* · Reproducibility of Results · Sensitivity and Specificity · Spinal Cord Injuries/therapy* · Young Adult

Card 4 — Version 2 Rasch study (Velstra 2018, Journal of Neurotrauma — 77 individuals with cervical SCI, 154 arms, 614 stacked observations across five time points): with minor adjustments the subscales showed good reliability, item fit and ordered response options; local item dependency was found in the strength and sensibility subscales, and item redundancies allowed shortening without reasonable reliability loss — the modified Version 2's evidence, printed as the version's: the interval-level property belongs to the modified form

Study: Rasch analysis (Version 2 derivation study)

Population: 77 individuals with cervical spinal cord injury (n = 154 arms), with GRASSP recorded within 10 days and at 1, 3, 6 and 12 months after injury; stacking left and right sides gave 614 observations based on the repeated measurements.

Summary: Version 2 Rasch study (Velstra 2018, Journal of Neurotrauma — 77 individuals with cervical SCI, 154 arms, 614 stacked observations across five time points): with minor adjustments the subscales showed good reliability, item fit and ordered response options; local item dependency was found in the strength and sensibility subscales, and item redundancies allowed shortening without reasonable reliability loss — the modified Version 2's evidence, printed as the version's: the interval-level property belongs to the modified form

Result: With minor adjustments, the GRASSP subscales showed good reliability, item fit, and ordered response options. Local item dependencies were found in the strength and sensibility subscales. Redundancies among some measurement items allowed shortening of the subscales without reasonable loss of reliability. Absence of differential item functioning for the examination stage supported robustness of the subscales over time. The modified GRASSP, now Version 2, subtest scores can be applied as interval level measurements, and the reduction of items allows shorter assessment times without degrading metric properties.

Watch out: Rasch fit was achieved by modifying the scale — adjusting and shortening subscales — so the interval-level claim attaches to Version 2 as modified, not to the original GRASSP scores clinicians may already hold. The analysis stacks repeated observations from 77 people; 614 is an observation count, not a patient count.

Source: Velstra IM et al. The Graded and Redefined Assessment of Strength, Sensibility, and Prehension Version 2 Provides Interval Measure Properties. Journal of neurotrauma. 2018. PMID: 29160145. Registry ID: none in the record. MeSH: Adult · Aged · Cervical Vertebrae · Cohort Studies · Disability Evaluation* · Female · Humans · Male · Middle Aged · Muscle Strength/physiology · Prospective Studies · Psychometrics · Quadriplegia/etiology,physiopathology* · Reproducibility of Results · Spinal Cord Injuries/complications,physiopathology* · Upper Extremity

Card 5 — Synthesis — GRASSP: 4 reports, all from the instrument's own development programme (documented samples 72 and 77; two records print no N)

Study: Synthesis

Population: Development report (2012, N not documented in its record), reliability and validity report (2012, 72 individuals with tetraplegia), responsiveness report (2016, N not documented in its record) and Version 2 Rasch study (2018, 77 individuals with cervical SCI). The two 2012 reports are companion reports of one programme and are never counted as independent replications.

Summary: Synthesis — GRASSP: 4 reports, all from the instrument's own development programme (documented samples 72 and 77; two records print no N)

Result: Reliability is consistently high in the programme's hands (inter-rater 0.84–0.96, test–retest 0.86–0.98 for all subtests), the GRASSP defines sensory and motor integrity with approximately 50% greater sensitivity than the ISNCSCI examination, its subtests concur with the SCIM and most strongly with the CUE self-perception questionnaire (0.57–0.83), its standardised response means exceeded the comparators' by 0.25–0.85 units with minimally detectable differences of 2–5 points, and Rasch analysis supports interval-level scoring for the modified Version 2 only. Nothing in this composition is a fully independent validation: every limb is the developing programme's, and the sensitivity claim is relative to a neurological examination, not to a functional gold standard. Cross-point in prose only: the SCIM is homed at pack #8370 as a different instrument (independence rather than impairment); the SCIM and CUE limbs inside these reports are comparators counted nowhere here.

Watch out: MEASUREMENT PROPERTIES — supported as the more sensitive upper-limb impairment measure in tetraplegia, on a single-programme base: the stamp's programme caveat is load-bearing — an independent group reproducing the reliability ranges and the sensitivity advantage would strengthen this shelf more than any further report from the programme itself.

Source: Synthesis of the reports carded above; no additional source.