Amputee Mobility Predictor (AMP) — 3 reports (the developer's development study in 191 amputees, a multisite battery reliability study in 44 patients, and a preliminary Italian validation in 28): inter-rater reliability .99 at derivation and discrimination among Medicare K-levels in both the derivation and the Italian sample, with no responsiveness limb in the base
Shelf #8724 · Bones & joints
MEASUREMENT PROPERTIES — supported for grading ambulatory potential in lower-limb amputees, with near-ceiling reliability that partly reflects the instrument's coarse grading — derivation inter-rater reliability was .99 in the developer's hands at one academic centre; the independent limbs are a 44-patient battery study printing only a battery-level ICC range (.83–.97 across the performance measures, no AMP-only coefficient extractable) and a 28-patient preliminary Italian translation (ICC 0.94/0.92). No responsiveness limb is in this composition.
Stamped: 2026-11-28.
Evidence published: 2002–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the Amputee Mobility Predictor (the clinician-rated instrument of ambulatory potential in lower-limb amputees, administered with the prosthesis as AMPPRO or without it as AMPnoPRO) — at its development for reliability and validity against Medicare functional classification levels and the 6-minute walk, in multisite test–retest reliability, and in its Italian validation?
Balance of the evidence
3 reports: the developer's development study (191 subjects: 24 reliability + 167 validity, one academic centre convenience sample), an independent multisite test–retest study of an outcome-measure battery that included the AMP (44 patients — a shared report, printed as shared; its modified Prosthetic Evaluation Questionnaire limb is counted nowhere in this pack), and a preliminary Italian cross-cultural validation (28 individuals). Combined documented N = 263 across three independent samples, never pooled into one claim. The TAPES and PLUS-M families are different instruments and are not counted; PLUS-M appears here only as a concurrent comparator inside the Italian report.
MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Amputees/rehabilitation* · Artificial Limbs · Female · Humans · Leg/physiopathology* · Locomotion/physiology* · Male · Middle Aged · Observer Variation · Predictive Value of Tests · Recovery of Function/physiology · Reproducibility of Results · Amputation, Surgical* · Amputees · Artificial Limbs* · Health Status Indicators · Leg/surgery* · Outcome Assessment, Health Care* · Quality of Life · Surveys and Questionnaires
Cards (4)
Card 1 — Development study (Gailey 2002, Archives of Physical Medicine and Rehabilitation — typed Validation Study; 191 lower-limb amputee subjects who had completed prosthetic training, 24 in the reliability study and 167 in the validity study): inter-rater reliability .99 with and without prosthesis, intra-rater .96 and .97; both AMPnoPRO and AMPPRO distinguished among the four Medicare functional classification levels (P < .0001) and correlated with the 6-minute walk at r = .69 and r = .82 — the developer's own report, in a convenience sample at one academic centre
Study: Validation study (development report) — programme report
Population: A convenience sample of 191 lower-limb amputee subjects who had completed prosthetic training: 24 in the reliability study (mean age 68.3 years) and 167 in the validity study (mean age 54.8 years), at an academic medical center.
Summary: Development study (Gailey 2002, Archives of Physical Medicine and Rehabilitation — typed Validation Study; 191 lower-limb amputee subjects who had completed prosthetic training, 24 in the reliability study and 167 in the validity study): inter-rater reliability .99 with and without prosthesis, intra-rater .96 and .97; both AMPnoPRO and AMPPRO distinguished among the four Medicare functional classification levels (P < .0001) and correlated with the 6-minute walk at r = .69 and r = .82 — the developer's own report, in a convenience sample at one academic centre
Result: Interrater reliability was .99 for subjects tested with and without their prosthesis; intrarater reliability was .96 and .97. Both the AMPnoPRO (P<.0001) and the AMPPRO scores (P<.0001) distinguished among the 4 Medicare functional classification levels. The AMP correlated strongly with 6-minute walk scores (AMPnoPRO r=.69, P<.0001; AMPPRO r=.82, P<.0001) and the amputee activity survey (AMPnoPRO r=.67, P<.0001; AMPPRO r=.77, P<.0001), and correlated with age (AMPnoPRO r=-.69, P<.0001; AMPPRO r=.56, P<.0001 — the AMPPRO–age sign prints exactly as the record prints it) and comorbidity (AMPnoPRO r=-.43, P<.0001; AMPPRO r=.38, P<.0001).
Watch out: Programme-labelled: the developer's own study in a convenience sample at one centre, and the near-ceiling .99 inter-rater figure partly reflects the instrument's coarse ordinal grading. The record's own text describes the age correlations as negative while printing the AMPPRO–age coefficient as +.56; the card carries the figures exactly as printed and no sign has been repaired.
Source: Gailey RS et al. The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate. Archives of physical medicine and rehabilitation. 2002. PMID: 11994800. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Amputees/rehabilitation* · Artificial Limbs · Female · Humans · Leg/physiopathology* · Locomotion/physiology* · Male · Middle Aged · Observer Variation · Predictive Value of Tests · Recovery of Function/physiology · Reproducibility of Results
Card 2 — Multisite reliability study (Resnik & Borgia 2011, Physical Therapy — 44 patients with unilateral lower-limb amputation tested twice within 1 week): the performance measures including the AMP showed strong test–retest reliability, ICC = .83–.97 across the battery, with minimal detectable change values calculated per measure — a shared report, printed as shared: the range is the battery's, and no AMP-only coefficient may be extracted from it
Study: Reliability study (shared battery report)
Population: 44 patients with unilateral lower-limb amputation at multiple sites, tested twice within 1 week on a battery: a modified Prosthetic Evaluation Questionnaire, SF-36V scales, the Orthotics and Prosthetics Users' Survey, the Patient-Specific Functional Scale, the Two-Minute and Six-Minute Walk Tests, the Timed Up & Go, and the Amputee Mobility Predictor.
Summary: Multisite reliability study (Resnik & Borgia 2011, Physical Therapy — 44 patients with unilateral lower-limb amputation tested twice within 1 week): the performance measures including the AMP showed strong test–retest reliability, ICC = .83–.97 across the battery, with minimal detectable change values calculated per measure — a shared report, printed as shared: the range is the battery's, and no AMP-only coefficient may be extracted from it
Result: The study demonstrated strong test-retest reliability scores of performance measures (ICC=.83-.97) suggesting that these measures are good choices for evaluation of people with lower-limb amputation. Reliability of PEQ subscales (ICC=.41-.93) was comparable to that reported in the literature (ICC=.56-.90). Minimal detectable change scores were calculated for each measure to determine whether change in test scores exceeds measurement error associated with day-to-day variation.
Watch out: Shared report: the ICC range .83–.97 spans the whole performance-measure battery, so this card supports the AMP's test–retest reliability only at battery level; the study examined statistically measurable differences and, by its own limitation statement, did not evaluate whether changes were clinically important. Its modified-PEQ limb is counted nowhere in this pack.
Source: Resnik L et al. Reliability of outcome measures for people with lower-limb amputations: distinguishing true change from statistical error. Physical therapy. 2011. PMID: 21310896. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Amputation, Surgical* · Amputees · Artificial Limbs* · Female · Health Status Indicators · Humans · Leg/surgery* · Male · Middle Aged · Outcome Assessment, Health Care* · Quality of Life · Reproducibility of Results · Surveys and Questionnaires
Card 3 — Italian validation (Manelli 2026, Prosthetics and Orthotics International — cross-sectional translation and preliminary validation of the AMP-IT in 28 individuals with lower limb amputation): internal consistency α = 0.986 (AMPPRO) and 0.980 (AMPnoPRO), test–retest ICC 0.94 / 0.92, concurrent correlations with the 6-minute walk r = 0.75–0.76 and with PLUS-M r = 0.62, and discrimination between K-levels (p < 0.01) — a preliminary validation in 28 patients, printed as such; the record's 2026 issue year prints as published
Study: Validation study (preliminary, cross-sectional translation)
Population: 28 individuals with lower limb amputation recruited from various rehabilitation centres in Italy.
Summary: Italian validation (Manelli 2026, Prosthetics and Orthotics International — cross-sectional translation and preliminary validation of the AMP-IT in 28 individuals with lower limb amputation): internal consistency α = 0.986 (AMPPRO) and 0.980 (AMPnoPRO), test–retest ICC 0.94 / 0.92, concurrent correlations with the 6-minute walk r = 0.75–0.76 and with PLUS-M r = 0.62, and discrimination between K-levels (p < 0.01) — a preliminary validation in 28 patients, printed as such; the record's 2026 issue year prints as published
Result: The AMP-IT demonstrated excellent internal consistency for both the AMPPRO (α = 0.986) and AMPnoPRO (α = 0.980) versions. Test-retest reliability was also excellent, with ICCs of 0.94 for AMPPRO and 0.92 for AMPnoPRO. Concurrent validity was supported by strong correlations with the 6MWT (r = 0.75-0.76) and a satisfactory correlation with the PLUS-M (r = 0.62). The tool successfully discriminated between different K-levels (p < 0.01).
Watch out: Preliminary by its own design and small: 28 patients, one language, no responsiveness or predictive limb. Internal-consistency alphas of 0.98+ on a short clinician-rated scale signal item redundancy as much as precision. The record carries no MeSH terms.
Source: Manelli A et al. Translation and validation of the Italian amputee mobility predictor: Assessing functional mobility in lower limb amputees. Prosthetics and orthotics international. 2026. PMID: 42169089. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis — Amputee Mobility Predictor: 3 reports (developer development study N=191; multisite battery study n=44; Italian preliminary validation n=28), combined documented N=263
Study: Synthesis
Population: Gailey 2002 (191 subjects: 24 reliability + 167 validity, one academic centre), Resnik & Borgia 2011 (44 patients, multisite battery — shared report), Manelli 2026 (28 individuals, Italian translation). Three independent samples; figures are never pooled across them.
Summary: Synthesis — Amputee Mobility Predictor: 3 reports (developer development study N=191; multisite battery study n=44; Italian preliminary validation n=28), combined documented N=263
Result: The AMP's grading of ambulatory potential is reproducible (inter-rater .99 at derivation; battery-level test–retest ICC .83–.97 in independent hands; Italian test–retest 0.94/0.92) and its scores track the constructs they should: Medicare K-levels in both the derivation and the Italian sample, and 6-minute walk distance at r = .69/.82 (derivation) and 0.75–0.76 (Italian). What the base does not contain is any responsiveness limb, any AMP-only coefficient from the one independent reliability study, or any validation larger than the developer's own 191 — the two independent limbs total 72 patients. The record-level defect on the derivation card (the AMPPRO–age sign printed +.56 inside a sentence describing negative correlations) is carried exactly as printed. The TAPES and PLUS-M families are different instruments, not counted here.
Watch out: MEASUREMENT PROPERTIES — supported for grading ambulatory potential, with near-ceiling reliability that partly reflects the instrument's coarse grading: the stamp rests on K-level discrimination replicating in a second language and sample, discounted by the small, preliminary independent limbs and the absent responsiveness evidence.
Source: Synthesis of the reports carded above; no additional source.