Venous thromboembolism risk assessment models in acutely ill medical inpatients (Padua, IMPROVE, Geneva, Caprini and others) — 4 reports (2 systematic reviews covering 11 and 51 studies; 2 large shared validation cohorts, n=14,660 and n=1,352): uniformly weak discrimination (pooled c-statistics often <0.7; head-to-head AUCs 0.538–0.64), and no model beats age alone in the 14,660-patient validation

Shelf #8761 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — uniformly weak, and that uniformity is the finding: across the 51-study systematic review, c-statistics were often <0.7 and no model performed obviously better than another; in the 14,660-patient PREVENU validation the AUCs were 0.60 (Caprini), 0.63 (IMPROVE) and 0.64 (Padua) — none significantly better than advanced age alone (0.61); in the prospective Swiss head-to-head all four models' AUCs sat between 0.538 and 0.581, and the simplified Geneva score's high-risk group (63.2% of patients) had a 90-day VTE risk of 2.6% against 1.2% in its low-risk group.

Stamped: 2026-11-28.

Evidence published: 2017–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In acutely ill medical inpatients, how well do the validated venous-thromboembolism risk assessment models — the Padua Prediction Score, the IMPROVE models, the Geneva scores and the Caprini model applied to medical patients — predict symptomatic VTE, and does any outperform the others or a single predictor such as age?

Balance of the evidence

4 reports = 2 systematic reviews (11 studies of 8 models; 51 validation studies of 24 models — both counted as syntheses) + 2 large shared validation cohorts (PREVENU, 14,660 evaluable medical inpatients; a Swiss prospective head-to-head, 1,352 inpatients). The PREVENU report's Caprini limb is counted here (medical population), not on pack #8760 (surgical populations); the Pandor review's surgical-population studies are background to #8760 and are counted nowhere here. No derivation report for any model is in this base. The Geneva VTE-prophylaxis risk score in this pack is a different instrument from the Geneva PE-diagnosis score homed inside the Wells pack #7803 — the shared city name is discharged explicitly. Event rates are low (1.8–2.1%), so every discrimination figure sits on 28–260 events depending on the anchor, printed per anchor; prophylaxis use confounds every validation, because high-risk patients are treated, compressing the very gradient being measured.

MeSH: Acute Disease · Anticoagulants/therapeutic use · Clinical Decision-Making · Decision Support Techniques* · Fibrinolytic Agents/therapeutic use · Humans · Incidence · Logistic Models · Multivariate Analysis · Odds Ratio · Patient Selection · Predictive Value of Tests · Prognosis · Risk Assessment · Risk Factors · Time Factors · Venous Thromboembolism/diagnosis,epidemiology*,mortality,prevention & control · Adult · Anticoagulants · Inpatients · Venous Thromboembolism*/epidemiology · Cohort Studies · Middle Aged · Retrospective Studies · Venous Thromboembolism*/diagnosis · Venous Thromboembolism*/epidemiology,prevention & control,etiology · Male · Female · Aged · Risk Assessment/methods · Prospective Studies · Inpatients*/statistics & numerical data · Switzerland/epidemiology · Hospitalization/statistics & numerical data

Cards (5)

Card 1 — Model systematic review (Stuck 2017, Thrombosis and Haemostasis — systematic review, 11 studies assessing 8 RAMs in acutely ill medical patients): four models (Kucher, Padua, Geneva, IMPROVE) had undergone multicentre external validation and three had improved prophylaxis rates or outcomes in implementation reports; the authors conclude existing RAMs are difficult to compare and none fulfils the criteria of an ideal RAM — synthesis, counted as a synthesis; a narrative review limb, never a pooled pair

Study: Systematic review (synthesis, narrative)

Population: 11 studies assessing eight risk assessment models (4-Element RAM, Caprini RAM, a full logistic model, Geneva risk score, IMPROVE-RAM, Kucher model, a multivariable model, and the Padua Prediction Score) for VTE in acutely ill medical patients, identified by a comprehensive MEDLINE search to May 2016.

Summary: Model systematic review (Stuck 2017, Thrombosis and Haemostasis — systematic review, 11 studies assessing 8 RAMs in acutely ill medical patients): four models (Kucher, Padua, Geneva, IMPROVE) had undergone multicentre external validation and three had improved prophylaxis rates or outcomes in implementation reports; the authors conclude existing RAMs are difficult to compare and none fulfils the criteria of an ideal RAM — synthesis, counted as a synthesis; a narrative review limb, never a pooled pair

Result: Four of the models (4-Element, IMPROVE, multivariable and full logistic) were derived by identifying factors with predictive power; the other four were empirically generated from consensus guidelines, published data and clinical expertise. The Kucher model, Padua Prediction Score, Geneva risk score and IMPROVE-RAM underwent multicentre external validation. The Kucher model, Padua score and Geneva score improved rates of thromboprophylaxis or clinical outcomes in implementation reports. The authors conclude existing RAMs are difficult to compare and none fulfils the criteria of an ideal RAM, while implementing a validated RAM may improve the adequacy of thromboprophylaxis.

Watch out: A narrative synthesis without pooled accuracy figures — it establishes the field's shape (eight models, four externally validated, none ideal) and prints no AUC of its own. Implementation benefit (better prophylaxis rates) is not the same claim as predictive accuracy, and the two are kept separate on this pack.

Source: Stuck AK et al. Risk assessment models for venous thromboembolism in acutely ill medical patients. A systematic review. Thrombosis and haemostasis. 2017. PMID: 28150851. Registry ID: none in the record. MeSH: Acute Disease · Anticoagulants/therapeutic use · Clinical Decision-Making · Decision Support Techniques* · Fibrinolytic Agents/therapeutic use · Humans · Incidence · Logistic Models · Multivariate Analysis · Odds Ratio · Patient Selection · Predictive Value of Tests · Prognosis · Risk Assessment · Risk Factors · Time Factors · Venous Thromboembolism/diagnosis,epidemiology*,mortality,prevention & control

Card 2 — Accuracy systematic review (Pandor 2021, BMJ Open — systematic review, 51 validation studies of 24 unique RAMs in hospitalised patients, 21 studies in medical inpatients): the most-evaluated models were Caprini (22 studies), Padua (16), IMPROVE (8), Geneva (4) and Kucher (4); c-statistics varied markedly (often weak, <0.7; sometimes 0.7–0.8; a few >0.8) and sensitivity ranged 12.0%–100% and specificity 7.2%–100% across studies — synthesis, counted as a synthesis; its surgical-population studies are background to pack #8760 and are counted nowhere here

Study: Systematic review (synthesis)

Population: 51 primary validation studies of 24 unique multivariable RAMs for predicting VTE in hospitalised adult inpatients (21 studies in patients requiring medical care, 15 in surgery, 4 in trauma), from 6,355 records; risk of bias assessed with PROBAST. The record prints its PROSPERO registration (CRD42020165778) in the abstract text only; it is carried verbatim on this card's source line, flagged in the builder summary.

Summary: Accuracy systematic review (Pandor 2021, BMJ Open — systematic review, 51 validation studies of 24 unique RAMs in hospitalised patients, 21 studies in medical inpatients): the most-evaluated models were Caprini (22 studies), Padua (16), IMPROVE (8), Geneva (4) and Kucher (4); c-statistics varied markedly (often weak, <0.7; sometimes 0.7–0.8; a few >0.8) and sensitivity ranged 12.0%–100% and specificity 7.2%–100% across studies — synthesis, counted as a synthesis; its surgical-population studies are background to pack #8760 and are counted nowhere here

Result: C-statistics varied markedly between studies and between models, with no one RAM performing obviously better than other models: across all models, c-statistics were often weak (<0.7), sometimes good (0.7–0.8) and a few excellent (>0.8). Sensitivity estimates ranged from 12.0% to 100% and specificity from 7.2% to 100%. The authors conclude RAMs have generally weak predictive accuracy for VTE and that heterogeneity prevents recommending any particular RAM.

Watch out: Ranges this wide (sensitivity 12–100%) describe a literature, not a model: thresholds, populations, outcomes and prophylaxis all vary between the pooled studies. The review's surgical studies overlap pack #8760's territory and are not double-counted here.

Source: Pandor A et al. Risk assessment models for venous thromboembolism in hospitalised adult patients: a systematic review. BMJ open. 2021. PMID: 34326045. Registry ID: PROSPERO CRD42020165778 (printed in the abstract text only; no databank entry in the record). MeSH: Adult · Anticoagulants · Humans · Inpatients · Risk Assessment · Risk Factors · Venous Thromboembolism*/epidemiology

Card 3 — PREVENU external validation (Moumneh 2020, Journal of Thrombosis and Haemostasis — external validation in the PREVENU cohort, 14,660 evaluable medical inpatients followed 3 months, 1.8% with symptomatic VTE or sudden unexplained death): AUCs 0.60 (95% CI 0.57–0.63) for Caprini, 0.63 (0.60–0.66) for IMPROVE and 0.64 (0.61–0.67) for Padua, none significantly better than advanced age as a stand-alone predictor (0.61, 0.58–0.64); body mass index — required by the Padua and Caprini scores — was missing in 44% of patients — shared report, printed as shared: its Caprini limb is counted here (medical population), not on pack #8760

Study: External validation study (shared report; all three model limbs are this pack's subject)

Population: 14,660 evaluable patients (of 14,910 eligible) aged 40 years or older, hospitalised at least 2 days on a medical ward (critically ill patients not recruited), prospectively enrolled in the PREVENU trial and followed for 3 months; suspected VTE and deaths were adjudicated by an independent committee. The three scores were assessed retrospectively.

Summary: PREVENU external validation (Moumneh 2020, Journal of Thrombosis and Haemostasis — external validation in the PREVENU cohort, 14,660 evaluable medical inpatients followed 3 months, 1.8% with symptomatic VTE or sudden unexplained death): AUCs 0.60 (95% CI 0.57–0.63) for Caprini, 0.63 (0.60–0.66) for IMPROVE and 0.64 (0.61–0.67) for Padua, none significantly better than advanced age as a stand-alone predictor (0.61, 0.58–0.64); body mass index — required by the Padua and Caprini scores — was missing in 44% of patients — shared report, printed as shared: its Caprini limb is counted here (medical population), not on pack #8760

Result: During the 3-month follow-up, 1.8% experienced symptomatic VTE or sudden unexplained death. The AUCs were 0.60 (95% CI 0.57–0.63) for Caprini, 0.63 (0.60–0.66) for IMPROVE and 0.64 (0.61–0.67) for Padua. None of these scores performed significantly better than advanced age as a single predictor (AUC 0.61, 0.58–0.64). Body mass index, needed for the Padua and Caprini scores, was missing in 44% of patients. The authors conclude the three scores have poor discriminative ability in not critically ill medical inpatients and do not perform better than age alone.

Watch out: The pack's most damaging single finding, on its largest cohort: three multi-item scores, none better than the patient's age. Scores were assessed retrospectively and a required input (BMI) was missing in 44% — real-world conditions, which is precisely the setting the scores are meant for.

Source: Moumneh T et al. Validation of risk assessment models predicting venous thromboembolism in acutely ill medical inpatients: A cohort study. Journal of thrombosis and haemostasis : JTH. 2020. PMID: 32168402. Registry ID: none in the record. MeSH: Adult · Anticoagulants/therapeutic use · Cohort Studies · Humans · Inpatients · Middle Aged · Retrospective Studies · Risk Assessment · Risk Factors · Venous Thromboembolism*/diagnosis

Card 4 — Swiss prospective head-to-head (Häfliger 2024, JAMA Network Open — prospective head-to-head validation, 1,352 medical inpatients at 3 Swiss university hospitals, 28 (2.1%) with symptomatic VTE within 90 days): the simplified Geneva score classified 63.2% as high-risk (90-day VTE 2.6%, 95% CI 1.7–3.9) vs 36.8% low-risk (1.2%, 0.6–2.6), with sensitivity 78.6% and specificity 37.2%; sensitivity was highest for the original Geneva score (82.1%) and specificity highest for IMPROVE (70.4%); AUCs for all models ranged 0.538–0.581 and no model's high/low split differed significantly after adjustment for prophylaxis and site

Study: Prospective cohort study (head-to-head validation)

Population: 1,352 adults (median age 67 years; 55.4% men) without therapeutic anticoagulation, admitted to general internal medicine departments of 3 Swiss university hospitals for acute illness (screened from 4,205 consecutive admissions; June 2020–January 2022), with items for four RAMs (simplified and original Geneva, Padua, IMPROVE) collected at admission and 90-day follow-up for symptomatic VTE, which occurred in 28 patients (2.1%).

Summary: Swiss prospective head-to-head (Häfliger 2024, JAMA Network Open — prospective head-to-head validation, 1,352 medical inpatients at 3 Swiss university hospitals, 28 (2.1%) with symptomatic VTE within 90 days): the simplified Geneva score classified 63.2% as high-risk (90-day VTE 2.6%, 95% CI 1.7–3.9) vs 36.8% low-risk (1.2%, 0.6–2.6), with sensitivity 78.6% and specificity 37.2%; sensitivity was highest for the original Geneva score (82.1%) and specificity highest for IMPROVE (70.4%); AUCs for all models ranged 0.538–0.581 and no model's high/low split differed significantly after adjustment for prophylaxis and site

Result: On the simplified Geneva score, 854 patients (63.2%) were high-risk, with a 90-day VTE risk of 2.6% (n=22; 95% CI 1.7%–3.9%), and 498 (36.8%) were low-risk, at 1.2% (n=6; 0.6%–2.6%). Its sensitivity was 78.6% (60.5%–89.8%), specificity 37.2% (34.6%–39.8%), positive likelihood ratio 1.25 and negative likelihood ratio 0.58. Sensitivity was highest for the original Geneva score (82.1%) and specificity highest for IMPROVE (70.4%). After adjustment for thromboprophylaxis use and site, no RAM's high/low split differed significantly (simplified Geneva subhazard ratio 2.04, 0.83–5.05; P=.12 — relative). Discriminative performance was poor for all RAMs, with AUCs from 0.538 (original Geneva) to 0.581 (simplified Geneva).

Watch out: A high-risk label that covers 63.2% of patients and carries a 2.6% event rate is doing little stratification work, and the adjusted null (subhazard ratio 2.04, interval crossing 1) is the honest summary of the prophylaxis-confounding problem: treated high-risk patients have their events prevented, compressing the gradient the model is judged on. Only 28 events underpin every figure on this card.

Source: Häfliger E et al. Risk Assessment Models for Venous Thromboembolism in Medical Inpatients. JAMA network open. 2024. PMID: 38728035. Registry ID: none in the record. MeSH: Humans · Venous Thromboembolism*/epidemiology,prevention & control,etiology · Male · Female · Middle Aged · Aged · Risk Assessment/methods · Prospective Studies · Inpatients*/statistics & numerical data · Switzerland/epidemiology · Hospitalization/statistics & numerical data · Risk Factors

Card 5 — Synthesis — medical-inpatient VTE risk models: 2 syntheses (11 and 51 studies) + 2 large shared validation cohorts (n=14,660 and n=1,352) — uniformly weak discrimination is the finding, at every level of the literature

Study: Synthesis

Population: Stuck 2017 (11 studies, 8 models), Pandor 2021 (51 studies, 24 models), Moumneh 2020 (14,660 patients, ~260 events), Häfliger 2024 (1,352 patients, 28 events).

Summary: Synthesis — medical-inpatient VTE risk models: 2 syntheses (11 and 51 studies) + 2 large shared validation cohorts (n=14,660 and n=1,352) — uniformly weak discrimination is the finding, at every level of the literature

Result: The review level says no model performs obviously better and c-statistics are often <0.7. The largest validation says Padua (0.64), IMPROVE (0.63) and Caprini (0.60) do not beat age alone (0.61). The prospective head-to-head says all four models sit at AUC 0.538–0.581, the flagship simplified Geneva split puts 63.2% of patients in a high-risk group whose event rate is 2.6%, and no split survives adjustment for prophylaxis and site. These are three statements of one finding, not three independent disappointments. No derivation report for any model is carded.

Watch out: PREDICTIVE PERFORMANCE is stated as uniformly weak — the honest headline a clinician needs before relying on any of these scores to allocate prophylaxis. Prophylaxis confounding runs through every validation and is printed, not used to excuse the figures away.

Source: Synthesis of the reports carded above; no additional source.