Ultrasound for rotator cuff tears — 4 syntheses with overlapping pools: sensitivity 0.96 / specificity 0.93 for full-thickness tears in the surgical-reference pool, partial-thickness sensitivity 0.67–0.84 by pool, and a network ranking below MRI and MR arthrography

Shelf #8764 · Bones & joints

PREDICTIVE PERFORMANCE — diagnostic accuracy, thickness-split: for full-thickness tears ultrasound pools at sensitivity 0.96 / specificity 0.93 (surgical-reference pool) and above 0.90 / 0.90 in the three-modality pool; for partial-thickness tears sensitivity falls to 0.84 in the surgical pool and 0.67–0.83 across pools while specificity holds above 0.89; in the network ranking ultrasound sits below MRI for any tear (sensitivity 0.81 vs 0.84, specificity 0.82 vs 0.86) and below MR arthrography overall. An accurate first test for full-thickness tears whose partial-thickness sensitivity — and whose specificity in the prospective-only pool (0.72 vs 0.93, unresolved) — are the honest limits. Base: 4 syntheses with heavily overlapping primary pools — one literature read four ways, never four independent confirmations.

Stamped: 2026-11-28.

Evidence published: 2011–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with shoulder pain and suspected rotator cuff tear, how accurately does ultrasound detect partial-thickness and full-thickness tears against arthroscopic/surgical or MRI reference standards — in the surgical-reference meta-analysis, in the three-modality meta-analysis, in the prospective-studies pool, and in the 144-study network meta-analysis ranking ultrasound against MRI and MR arthrography?

Balance of the evidence

4 reports, all syntheses with heavily overlapping primary pools spanning 2011–2020 (62 studies / 6,007 patients; a three-modality pool; 7 prospective studies / 868 patients; a 144-study network meta-analysis / 14,059 patients). Reference standards split (surgery in the 2011 pool; surgery or MRI in the later pools) and print per card. Only the ultrasound limb is this pack's subject; the MRI/MRA limbs are the comparators the pack ranks against. Contested and unresolved: the surgical-reference pool's specificity (0.93) vs the prospective-only pool's (0.72), with sensitivity concordant (0.95–0.96) — both pairs print with their pools named. Cross-point in prose only: the shoulder examination-test pack #7861 asks the bedside-test question, not this imaging question.

MeSH: Female · Humans · Male · ROC Curve · Reproducibility of Results · Rotator Cuff/diagnostic imaging* · Rotator Cuff Injuries* · Sensitivity and Specificity · Tendon Injuries/diagnostic imaging* · Ultrasonography · Arthrography/methods · Diagnostic Imaging/methods* · Joint Diseases/diagnosis · Magnetic Resonance Imaging/methods · Rotator Cuff · Rupture/diagnosis · Shoulder Injuries · Tendinopathy/diagnosis* · Tendon Injuries/diagnosis* · Rotator Cuff/diagnostic imaging · Rotator Cuff Injuries/diagnostic imaging* · Ultrasonography/methods*

Cards (5)

Card 1 — Surgical-reference meta-analysis (Smith 2011, Clinical Radiology — 62 studies / 6,007 patients / 6,066 shoulders against arthroscopic or open surgical findings): ultrasound sensitivity/specificity were 0.96 / 0.93 for full-thickness and 0.84 / 0.89 for partial-thickness tears; the literature poorly described population characteristics and assessor blinding and rested on limited sample sizes

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 6,007 patients (6,066 shoulders) across 62 diagnostic accuracy studies that directly compared ultrasound (index test) with arthroscopic or open surgical findings (reference test) for rotator cuff tear; methodological quality was assessed with the QUADAS form.

Summary: Surgical-reference meta-analysis (Smith 2011, Clinical Radiology — 62 studies / 6,007 patients / 6,066 shoulders against arthroscopic or open surgical findings): ultrasound sensitivity/specificity were 0.96 / 0.93 for full-thickness and 0.84 / 0.89 for partial-thickness tears; the literature poorly described population characteristics and assessor blinding and rested on limited sample sizes

Result: Ultrasonography had good sensitivity and specificity for partial-thickness tears (sensitivity 0.84; specificity 0.89) and full-thickness rotator cuff tears (sensitivity 0.96; specificity 0.93). The literature poorly described population characteristics and assessor blinding, and was based on limited sample sizes; the literature assessing transducer frequency was particularly small. The authors conclude ultrasonography is appropriate for assessing rotator cuff tears, with diagnostic accuracy superior for full-thickness compared with partial-thickness tears.

Watch out: The strongest reference standard in this pack (surgery) — and the pool whose 0.93 specificity the prospective-only pool below contradicts (0.72). Poorly described populations and blinding mean spectrum bias cannot be excluded from these pooled pairs.

Source: Smith TO et al. Diagnostic accuracy of ultrasound for rotator cuff tears in adults: a systematic review and meta-analysis. Clinical radiology. 2011. PMID: 21737069. Registry ID: none in the record. MeSH: Female · Humans · Male · ROC Curve · Reproducibility of Results · Rotator Cuff/diagnostic imaging* · Rotator Cuff Injuries* · Sensitivity and Specificity · Tendon Injuries/diagnostic imaging* · Ultrasonography

Card 2 — Three-modality meta-analysis (Roy 2015, British Journal of Sports Medicine — ultrasonography, MRI and MR arthrography): for full-thickness tears all three modalities' pooled sensitivity and specificity exceeded 0.90; for partial tears and tendinopathy specificity stayed >0.90 while sensitivity was 0.67–0.83; ultrasound accuracy was similar whether performed by a radiologist, sonographer or orthopaedist — only the ultrasound limb is this pack's subject

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis; ultrasound limb only)

Population: Patients in the diagnostic studies pooled across three databases for the characterisation of rotator cuff disorders by ultrasonography, MRI and MR arthrography; the record does not print a single pooled patient total for this synthesis in its abstract.

Summary: Three-modality meta-analysis (Roy 2015, British Journal of Sports Medicine — ultrasonography, MRI and MR arthrography): for full-thickness tears all three modalities' pooled sensitivity and specificity exceeded 0.90; for partial tears and tendinopathy specificity stayed >0.90 while sensitivity was 0.67–0.83; ultrasound accuracy was similar whether performed by a radiologist, sonographer or orthopaedist — only the ultrasound limb is this pack's subject

Result: Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness rotator cuff tears was high, with overall estimates of sensitivity and specificity over 0.90. For partial rotator cuff tears and tendinopathy, overall estimates of specificity were also high (>0.90) while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. The authors conclude that, considering accuracy, cost and safety, US is the best option for full-thickness tear characterisation.

Watch out: The 0.67–0.83 partial-tear sensitivity range spans all three modalities in this pool — it is not an ultrasound-only figure and no card may print it as one. The operator-subgroup null (radiologist vs sonographer vs orthopaedist) is the only anchor in this pack that addresses operator dependence, ultrasound's standing clinical caveat.

Source: Roy JS et al. Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: a systematic review and meta-analysis. British journal of sports medicine. 2015. PMID: 25677796. Registry ID: none in the record. MeSH: Arthrography/methods · Diagnostic Imaging/methods* · Humans · Joint Diseases/diagnosis · Magnetic Resonance Imaging/methods · Rotator Cuff · Rupture/diagnosis · Sensitivity and Specificity · Shoulder Injuries · Tendinopathy/diagnosis* · Tendon Injuries/diagnosis*

Card 3 — Prospective-studies pool (Liang 2020, Medical Ultrasonography — 7 prospective studies / 868 patients (554 tears) against arthroscopy or MRI): pooled sensitivity 95% (95% CI 88–98), specificity 72% (61–81), positive/negative likelihood ratios 3.41 / 0.08 (labelled as such) and summary ROC area 0.89 for rotator cuff tears overall — its specificity is the lowest in this pack and prints beside the surgical pool's 0.93, unresolved

Study: Systematic review and meta-analysis restricted to prospective studies (synthesis, counted as a synthesis)

Population: 868 patients (554 rotator cuff tears) in 7 prospective studies meeting the inclusion criteria, with arthroscopy or MRI as the reference standard; literature searched to May 2018.

Summary: Prospective-studies pool (Liang 2020, Medical Ultrasonography — 7 prospective studies / 868 patients (554 tears) against arthroscopy or MRI): pooled sensitivity 95% (95% CI 88–98), specificity 72% (61–81), positive/negative likelihood ratios 3.41 / 0.08 (labelled as such) and summary ROC area 0.89 for rotator cuff tears overall — its specificity is the lowest in this pack and prints beside the surgical pool's 0.93, unresolved

Result: Pooled sensitivity was 95% (95% CI 88–98), pooled specificity 72% (95% CI 61–81), pooled positive likelihood ratio 3.41 (95% CI 2.40–4.84), pooled negative likelihood ratio 0.08 (95% CI 0.03–0.16), pooled diagnostic odds ratio 45.31 (95% CI 21.04–97.59), and the area under the summary ROC curve was 89% (95% CI 0.86–0.91), with post-test probabilities of 46% and 2% as published. The authors conclude ultrasound has high efficiency for rotator cuff tear diagnosis.

Watch out: Contested, unresolved: specificity 0.72 here vs 0.93 in the surgical-reference pool, with sensitivity concordant (0.95–0.96). Whether this is reference-standard mix (this pool admits MRI), spectrum, or small-pool noise (7 studies) is not resolved by any anchor — both pairs print with their pools named, and this pool's tears are not split by thickness.

Source: Liang W et al. Diagnostic performance of ultrasound for rotator cuff tears: a systematic review and meta-analysis. Medical ultrasonography. 2020. PMID: 32190853. Registry ID: none in the record. MeSH: Humans · Reproducibility of Results · Rotator Cuff/diagnostic imaging · Rotator Cuff Injuries/diagnostic imaging* · Sensitivity and Specificity · Ultrasonography/methods*

Card 4 — Network meta-analysis (Liu 2020, Orthopaedic Journal of Sports Medicine — 144 studies / 14,059 patients (14,212 shoulders)): MR arthrography ranked highest for full-thickness, partial-thickness and any tear; for any tear MRI exceeded ultrasound (sensitivity 0.84 vs 0.81, specificity 0.86 vs 0.82) and for full-thickness tears MRI's sensitivity was 0.91 vs ultrasound's 0.87 at equal specificity (0.88) — TYPE-FLAG: typed Journal Article / Review at PubMed although a network meta-analysis on substance

Study: Network meta-analysis (synthesis, counted as a synthesis) — TYPE-FLAG: the record types it Journal Article / Review only; counted on substance

Population: 14,059 patients (14,212 shoulders) in 144 diagnostic studies of MRI, MR arthrography and ultrasound for detection of rotator cuff tears, retrieved from PubMed/MEDLINE and Embase.

Summary: Network meta-analysis (Liu 2020, Orthopaedic Journal of Sports Medicine — 144 studies / 14,059 patients (14,212 shoulders)): MR arthrography ranked highest for full-thickness, partial-thickness and any tear; for any tear MRI exceeded ultrasound (sensitivity 0.84 vs 0.81, specificity 0.86 vs 0.82) and for full-thickness tears MRI's sensitivity was 0.91 vs ultrasound's 0.87 at equal specificity (0.88) — TYPE-FLAG: typed Journal Article / Review at PubMed although a network meta-analysis on substance

Result: For detection of full-thickness tears, partial-thickness tears, or any tear, MR arthrography had the highest sensitivity, specificity, and superiority index. For any tear, MRI had better performance than ultrasound (sensitivity 0.84 vs 0.81, specificity 0.86 vs 0.82, superiority index 0.98 vs 0.22). For full-thickness tears, MRI had a higher sensitivity and superiority index than ultrasound (0.91 vs 0.87 and 0.67 vs 0.28) and a similar specificity (0.88 vs 0.88). Results for partial-thickness tears were similar to full-thickness tears, and a sensitivity analysis removing single-arm studies left the results stable. The ranking given is: high-field MRA, low-field MRA, high-field MRI, high-frequency US, low-field MRI, low-frequency US.

Watch out: A ranking across an overlapping literature, not an independent confirmation: most primary studies here also sit inside the other three pools. Ultrasound's network figures (0.81/0.82 for any tear) are lower than its surgical-pool figures — pool construction, not the test, is what changes.

Source: Liu F et al. Detecting Rotator Cuff Tears: A Network Meta-analysis of 144 Diagnostic Studies. Orthopaedic journal of sports medicine. 2020. PMID: 32076627. Registry ID: none in the record. MeSH: none in the record

Card 5 — Synthesis — shoulder ultrasound for rotator cuff tears: 4 syntheses, one literature read four ways (2011–2020), thickness-split throughout

Study: Synthesis

Population: Pools: 62 studies / 6,007 patients (surgical reference); a three-modality pool; 7 prospective studies / 868 patients; 144 studies / 14,059 patients (network). The pools overlap heavily and are never counted as independent confirmations.

Summary: Synthesis — shoulder ultrasound for rotator cuff tears: 4 syntheses, one literature read four ways (2011–2020), thickness-split throughout

Result: Full-thickness tears: ultrasound is accurate in every pool (0.96/0.93 surgical; >0.90/>0.90 three-modality; 0.87 sensitivity at 0.88 specificity in the network). Partial-thickness tears: sensitivity is the weak limb everywhere (0.84 surgical pool; 0.67–0.83 across the three-modality pool) while specificity holds. The network ranking places ultrasound below MRI and below MR arthrography. The specificity disagreement (0.93 surgical pool vs 0.72 prospective-only pool) prints unresolved. PREDICTIVE PERFORMANCE (diagnostic accuracy) is the stamp; the thickness split is its content.

Watch out: No primary study is carded on this pack — the primary literature enters only through these pools, so no figure here is independent of pool construction (reference standard, spectrum, era of transducer technology). Cross-point in prose only: shoulder examination tests are homed at pack #7861.

Source: Synthesis of the reports carded above; no additional source.