reduced Morningness-Eveningness Questionnaire (rMEQ) — 4 reports = 1 psychometric review limb + Swedish, Japanese and Turkish validations of the 5-item form: alphas 0.618–0.706, every validation against the parent MEQ itself, and none against an objective circadian marker

Shelf #8774 · Lungs, breathing & sleep

MEASUREMENT PROPERTIES — an adequate five-item proxy for the parent questionnaire, with sub-threshold internal consistency — across 3 primary validations and 1 review limb, the rMEQ reproduces the MEQ's classification (Japanese agreement 77.6%, weighted kappa 0.72; Turkish sensitivity/specificity 83.3–92.7% for morning and 86.3–87.3% for evening types, against the MEQ itself), but its internal consistency is 0.618–0.706 — below conventional thresholds in the two largest samples — every validation is against the parent form whose items it shares, and no limb validates against an objective circadian marker.

Stamped: 2026-11-28.

Evidence published: 2013–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the rMEQ (the 5-item reduced form of the Horne & Östberg Morningness-Eveningness Questionnaire) — what does the psychometric review of circadian-typology measures conclude about it, and what reliability and classification performance did its Swedish, Japanese and Turkish validations find?

Balance of the evidence

4 reports = 3 primary language validations (Swedish: 1,000 mailed, 68% response; Japanese: 2,213 respondents in existing MEQ data; Turkish: 875 university students) + 1 psychometric review counted as a review limb only, never as a primary report. This is a reduced-form shelf: the full 19-item MEQ's 1976 derivation predates abstract records and is not carded, and no figure here is evidence about the full MEQ. The Munich ChronoType Questionnaire is a different instrument, name-checked in the review limb only and counted nowhere. All classification figures are relative to the parent MEQ and print labelled as such. The 0.70 threshold the cards invoke, in plain words: 0.70 is the conventional floor for internal consistency (Cronbach's alpha) — at or above it, a scale's items are taken to hang together well enough for its score to be used in comparing groups. The Swedish (0.68) and Japanese (0.618) validations fall below that floor and only the Turkish validation (0.706) clears it, which is why the short form's internal consistency prints as sub-threshold.

MeSH: Circadian Rhythm/physiology* · Humans · Psychometrics*/methods · Reproducibility of Results · Research Design · Sleep/physiology* · Surveys and Questionnaires · Adolescent · Adult · Circadian Clocks* · Circadian Rhythm* · Female · Male · Mood Disorders · Psychometrics* · Sleep · Sweden · Time Factors · Young Adult · Circadian Rhythm*/physiology · Japan · Middle Aged · Sleep/physiology · Factor Analysis, Statistical · East Asian People · Turkey

Cards (5)

Card 1 — Psychometric review of circadian-typology measures (Di Milia 2013, Chronobiology International — review limb, counted as a review only): the MEQ, Composite Scale of Morningness and Preferences Scale consistently report reliability >0.80, whereas the rMEQ's reliability is 'satisfactory'; the literature's major limitation is the near-absence of predictive-validity studies

Study: Review (counted as a review limb only, never as a primary report)

Population: A review of the published psychometric evidence for the MEQ, rMEQ, Composite Scale of Morningness, Preferences Scale and Munich ChronoType Questionnaire; no primary sample — N not documented for the rMEQ limb.

Summary: Psychometric review of circadian-typology measures (Di Milia 2013, Chronobiology International — review limb, counted as a review only): the MEQ, Composite Scale of Morningness and Preferences Scale consistently report reliability >0.80, whereas the rMEQ's reliability is 'satisfactory'; the literature's major limitation is the near-absence of predictive-validity studies

Result: The MEQ, CSM and PS consistently report high reliability (>0.80), whereas the reliability of the rMEQ is satisfactory; stability of the scales is sound at follow-up periods up to 13 months; the MEQ, rMEQ and CSM are highly correlated, as expected given shared items; and a major limitation of this literature is the absence of studies assessing predictive validity, as published.

Watch out: Only the rMEQ limb of this review is counted here; its MEQ/CSM/PS/MCTQ figures are counted nowhere on this shelf. A review's 'satisfactory' is a summary judgement, not a coefficient.

Source: Di Milia L et al. Reviewing the psychometric properties of contemporary circadian typology measures. Chronobiology international. 2013. PMID: 24001393. Registry ID: none in the record. MeSH: Circadian Rhythm/physiology* · Humans · Psychometrics*/methods · Reproducibility of Results · Research Design · Sleep/physiology* · Surveys and Questionnaires

Card 2 — Swedish validation (Danielsson 2019, Chronobiology International — rMEQ mailed to 1,000 randomly selected 16–26-year-olds in Uppsala, response rate 68%): single-factor solution, inter-item correlations 0.08–0.46, Cronbach's alpha 0.68; the authors conclude the rMEQ can estimate chronotype when a short questionnaire is required, with caution in interpretation given its reliability

Study: Validation study

Population: 1,000 randomly selected individuals aged 16–26 years in Uppsala, Sweden, mailed the rMEQ with sleep, insomnia (ISI), sleepiness and mood (HADS) questionnaires; response rate 68%.

Summary: Swedish validation (Danielsson 2019, Chronobiology International — rMEQ mailed to 1,000 randomly selected 16–26-year-olds in Uppsala, response rate 68%): single-factor solution, inter-item correlations 0.08–0.46, Cronbach's alpha 0.68; the authors conclude the rMEQ can estimate chronotype when a short questionnaire is required, with caution in interpretation given its reliability

Result: Parallel analysis gave a single-factor solution; inter-item correlations were 0.08–0.46, with one item weakly correlated with the rest; Cronbach's alpha was 0.68. Low (eveningness) scores correlated with later bedtimes, difficulty rising, male sex, no educational activity or work, nicotine use, younger age, and higher ISI and HADS-D scores, as published.

Watch out: The authors' own caution prints at headline weight: alpha 0.68 is below the conventional 0.70 threshold, and one of the five items barely correlates with the others. Validity here is against sleep-behaviour self-reports, not against any circadian biomarker.

Source: Danielsson K et al. The reduced Morningness-Eveningness Questionnaire: Psychometric properties and related factors in a young Swedish population. Chronobiology international. 2019. PMID: 30614272. Registry ID: none in the record. MeSH: Adolescent · Adult · Circadian Clocks* · Circadian Rhythm* · Female · Humans · Male · Mood Disorders · Psychometrics* · Sleep · Surveys and Questionnaires · Sweden · Time Factors · Young Adult

Card 3 — Japanese validation (Eto 2024, Chronobiology International — the 5 items selected from existing Japanese MEQ data, N = 2,213): one-factor structure confirmed (CFI 0.935, RMSEA 0.091); alpha 0.618, omega 0.654; rMEQ–MEQ correlation rho = 0.883; three-type classification agreement with the MEQ 77.6% (weighted kappa 0.72)

Study: Validation study

Population: 2,213 respondents in existing Japanese MEQ datasets, from which the 5 rMEQ items were selected and the short form compiled.

Summary: Japanese validation (Eto 2024, Chronobiology International — the 5 items selected from existing Japanese MEQ data, N = 2,213): one-factor structure confirmed (CFI 0.935, RMSEA 0.091); alpha 0.618, omega 0.654; rMEQ–MEQ correlation rho = 0.883; three-type classification agreement with the MEQ 77.6% (weighted kappa 0.72)

Result: Confirmatory factor analysis confirmed a robust one-factor structure (GFI 0.984, AGFI 0.951, CFI 0.935, RMSEA 0.091). Internal consistency was Cronbach's alpha 0.618 and McDonald's omega 0.654. rMEQ scores correlated strongly with the MEQ (rho = 0.883, p < 0.001), and classification agreement (morning / neither / evening) with the MEQ was 77.6% (weighted Cohen's kappa 0.72), as published.

Watch out: The 0.618 alpha prints: in the largest sample in this composition, the short form's internal consistency is below conventional thresholds. The rho = 0.883 correlation is with the parent questionnaire from whose items the rMEQ is drawn — partly a part–whole correlation, not independent validation.

Source: Eto T et al. The Japanese version of the reduced morningness-eveningness questionnaire. Chronobiology international. 2024. PMID: 38557262. Registry ID: none in the record. MeSH: Humans · Circadian Rhythm*/physiology · Surveys and Questionnaires · Male · Female · Adult · Reproducibility of Results · Japan · Psychometrics* · Young Adult · Middle Aged · Sleep/physiology · Factor Analysis, Statistical · East Asian People

Card 4 — Turkish validation (Uygur 2024, Chronobiology International — 875 university students): one-dimensional structure with good fit (CFI 0.990, RMSEA 0.047); alpha 0.706, omega 0.740; sensitivity/specificity 83.3–92.7% for morning types and 86.3–87.3% for evening types — classification against the full MEQ, not against any objective circadian marker

Study: Validation study

Population: 875 university students in a Turkish adaptation and validation study, completing the rMEQ, MEQ and symptom/impulsiveness/happiness scales.

Summary: Turkish validation (Uygur 2024, Chronobiology International — 875 university students): one-dimensional structure with good fit (CFI 0.990, RMSEA 0.047); alpha 0.706, omega 0.740; sensitivity/specificity 83.3–92.7% for morning types and 86.3–87.3% for evening types — classification against the full MEQ, not against any objective circadian marker

Result: Confirmatory factor analysis showed a one-dimensional structure with good fit (CFI 0.990, TLI 0.979, RMSEA 0.047, SRMR 0.019). There was a significantly strong correlation between the rMEQ and the MEQ, and weak correlations with DASS-21, ISI, impulsiveness and happiness scales. Internal consistency was Cronbach's alpha 0.706 and McDonald's omega 0.740; sensitivity and specificity were 83.3%–92.7% for morning types and 86.3%–87.3% for evening types, as published.

Watch out: The classification figures are relative to the parent MEQ — the criterion is the questionnaire the short form abbreviates. A student sample is a narrow base for a general chronotype claim.

Source: Uygur H et al. Psychometric properties of the Turkish reduced morningness and eveningness questionnaire. Chronobiology international. 2024. PMID: 38629999. Registry ID: none in the record. MeSH: Humans · Psychometrics* · Female · Male · Surveys and Questionnaires · Young Adult · Circadian Rhythm*/physiology · Adult · Turkey · Reproducibility of Results · Adolescent · Sleep/physiology

Card 5 — Synthesis — 4 reports = 1 psychometric review limb + 3 primary validations (Swedish mailed sample of 1,000 with 68% response; Japanese N = 2,213; Turkish 875 students)

Study: Synthesis

Population: The entire carded base: Di Milia 2013 (review limb only), Danielsson 2019, Eto 2024 (2,213) and Uygur 2024 (875). The full 19-item MEQ's derivation (Horne & Östberg 1976) predates abstract records and no cardable full-MEQ validation composition exists — this is a reduced-form shelf, and nothing here is evidence about the full MEQ.

Summary: Synthesis — 4 reports = 1 psychometric review limb + 3 primary validations (Swedish mailed sample of 1,000 with 68% response; Japanese N = 2,213; Turkish 875 students)

Result: Every validation validates the 5-item rMEQ against the MEQ itself (shared items; rho = 0.883 in the Japanese limb is partly part–whole correlation); no limb validates against dim-light melatonin onset, actigraphy or any other objective circadian marker, and the review limb names the near-absence of predictive-validity studies as the whole literature's major limitation. Internal consistency runs 0.618–0.706 — below conventional thresholds in the two largest samples — and the Swedish authors print their own caution about interpretation. The shelf is honest as a short-form transport story: an adequate proxy for the parent questionnaire when five items are all that is feasible, and nothing more.

Watch out: This is the weakest composition among its sibling measurement shelves: three transports of one short form, all criterion-referenced to their own parent, plus a review. It must never be printed as chronotype measurement validated against biology.

Source: Synthesis of the reports carded above; no additional source.