SourceMed · Shelf #8817 in the ask interface

Altman Self-Rating Mania Scale (ASRM) — 3 reports: derivation sensitivity 85.5% / specificity 87.3% at >5, a coefficient-free Spanish validation, and a 1,091-student Korean limb

Shelf #8817 · Brain, stroke & mind

MEASUREMENT PROPERTIES — supported as a brief self-rating mania screen (derivation sensitivity 85.5% / specificity 87.3% at a mania-subscale score > 5), on a developer head, a coefficient-free Spanish limb and a non-clinical Korean limb — the only patient-sample transport prints no coefficient, and the largest sample (1,091 undergraduates) contains no patients.

Stamped: 2026-11-28.

Evidence published: 1997–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the ASRM (Altman's 5-item self-rating mania scale) — at its derivation against clinician mania ratings, in its Spanish validation, and in its Korean version tested in non-clinical undergraduates?

Balance of the evidence

3 reports: the developer's own derivation (105 patients plus a 30-patient test–retest sample), a Spanish validation in 74 bipolar patients that prints no coefficient and no AUC, and a Korean validation in 1,091 non-clinical undergraduates. The only patient-sample transport prints no number, and the largest sample contains no patients — the composition's shape is printed on the stamp. No responsiveness limb is in this composition. Cross-point in prose only: the clinician-rated YMRS literature is a different instrument (a self-rating scale is rowed here); no YMRS measurement figure is counted.

MeSH: Adult · Bipolar Disorder/diagnosis* · Depressive Disorder/diagnosis · Female · Humans · Male · Middle Aged · Predictive Value of Tests · Psychiatric Status Rating Scales* · Severity of Illness Index · Adolescent · Aged · Language · Reproducibility of Results · Social Environment* · Spain · Surveys and Questionnaires* · Translations*

Cards (4)

Card 1 — Altman derivation 1997 (Biological Psychiatry — developer's own report; 105 patients: 22 schizophrenia, 13 schizoaffective, 36 depressed, 34 manic, with test–retest in a further 30): three factors (mania, psychotic symptoms, irritability); the mania subscale correlated r = 0.718 with the Mania Rating Scale and 0.766 with the CARS-M mania subscale; a mania-subscale score > 5 gave sensitivity 85.5% and specificity 87.3% for mania — programme-labelled

Study: Derivation / validation study (primary report; programme-labelled — the developer's own report)

Population: 105 patients (22 with schizophrenia, 13 schizoaffective, 36 depressed, 34 manic) who completed the ASRM during medication washout and after treatment, with the Clinician-Administered Rating Scale for Mania (CARS-M) and Mania Rating Scale (MRS) completed at the same time; test–retest reliability was assessed separately in 20 depressed and 10 manic patients who completed the ASRM twice during washout.

Summary: Altman derivation 1997 (Biological Psychiatry — developer's own report; 105 patients: 22 schizophrenia, 13 schizoaffective, 36 depressed, 34 manic, with test–retest in a further 30): three factors (mania, psychotic symptoms, irritability); the mania subscale correlated r = 0.718 with the Mania Rating Scale and 0.766 with the CARS-M mania subscale; a mania-subscale score > 5 gave sensitivity 85.5% and specificity 87.3% for mania — programme-labelled

Result: Principal components analysis revealed three factors: mania, psychotic symptoms and irritability. Baseline mania subscale scores were significantly higher for manic patients than for all other diagnostic groups, and manic patients' scores decreased post-treatment on all three subscales. ASRM mania subscale scores correlated with MRS total scores (r = .718) and CARS-M mania subscale scores (r = .766). Test–retest reliability was significant for all three subscales. Mania subscale scores greater than 5 resulted in sensitivity 85.5% and specificity 87.3% for mania. Severity levels for some symptoms differed between patient self-ratings and clinician CARS-M ratings.

Watch out: Every accuracy figure on this shelf's stamp comes from this single developer report, in a washout-era inpatient spectrum. The sensitivity/specificity pair belongs to the mania subscale at a cut-off of >5, not to the total scale, and prints with that attachment.

Source: Altman EG et al. The Altman Self-Rating Mania Scale. Biological psychiatry. 1997. PMID: 9359982. Registry ID: none in the record. MeSH: Adult · Bipolar Disorder/diagnosis* · Depressive Disorder/diagnosis · Female · Humans · Male · Middle Aged · Predictive Value of Tests · Psychiatric Status Rating Scales* · Severity of Illness Index

Card 2 — Alvarez Mas Spanish validation 2005 (Actas Españolas de Psiquiatría — typed Validation Study; 74 bipolar patients: 35 acute mania, 39 asymptomatic): high internal consistency and a high, significant correlation with the CARS-M mania subscale as published — no coefficient printed in the record, none may be printed; a single factor explained 62% of the total variance; ROC discrimination described as excellent, with no AUC printed

Study: Validation study (translation validation; coefficient-free record)

Population: 74 patients with bipolar disorder in the Spanish validation: 35 with acute mania and 39 asymptomatic; the CARS-M and the Numeric Evaluation Scale (NES) were applied concurrently.

Summary: Alvarez Mas Spanish validation 2005 (Actas Españolas de Psiquiatría — typed Validation Study; 74 bipolar patients: 35 acute mania, 39 asymptomatic): high internal consistency and a high, significant correlation with the CARS-M mania subscale as published — no coefficient printed in the record, none may be printed; a single factor explained 62% of the total variance; ROC discrimination described as excellent, with no AUC printed

Result: High internal consistency, high and significant correlation with the CARS-M mania sub-scale and with the NES, and very significant differences between the acute-mania and asymptomatic groups in scale score. The ROC curve indicated excellent adjustment of the scale when discriminating bipolar patients with and without manic symptoms. Factorial analysis provided a single factor accounting for 62% of the total variance. The record prints no correlation coefficient and no AUC — none may be printed from this card.

Watch out: This is the composition's only independent patient-sample transport, and it is figure-free: it supports the scale's direction in Spanish bipolar patients and nothing quantitative. Its single-factor result also differs from the derivation's three-factor structure — printed as a structural difference, not reconciled.

Source: Alvarez Mas P et al. [Translation and adaptation in the Spanish environment of the Altman Self-Rating Mania Scale]. Actas espanolas de psiquiatria. 2005. PMID: 15918086. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Bipolar Disorder/diagnosis* · Female · Humans · Language · Male · Middle Aged · Reproducibility of Results · Social Environment* · Spain · Surveys and Questionnaires* · Translations*

Card 3 — Kim & Kwon Korean validation 2017 (Psychiatry Investigation — 1,091 non-clinical undergraduates): Cronbach's alpha 0.73, one factor of mania; correlations with hypomanic personality 0.33 and positive affect 0.53, as published — a non-clinical transport: it validates screening variance in students, not mania measurement in patients, and prints as such

Study: Validation study (non-clinical sample; no MeSH in the record)

Population: 1,091 Korean non-clinical undergraduates who completed the Korean ASRM (K-ASRM) with other self-report questionnaires assessing bipolarity, mood symptoms and affect.

Summary: Kim & Kwon Korean validation 2017 (Psychiatry Investigation — 1,091 non-clinical undergraduates): Cronbach's alpha 0.73, one factor of mania; correlations with hypomanic personality 0.33 and positive affect 0.53, as published — a non-clinical transport: it validates screening variance in students, not mania measurement in patients, and prints as such

Result: Reliability was adequate (Cronbach's α = 0.73; item-to-total correlations 0.53–0.78) and exploratory factor analysis yielded one factor of mania. The K-ASRM correlated significantly with hypomanic personality (r = 0.33), lifetime history of hypomanic symptoms (r = 0.23), positive affect (r = 0.53), negative affect (r = −0.17) and depressive symptoms (r = −0.35). The authors frame the results as a preliminary possibility for use as a self-rating tool for mania in Korea.

Watch out: The largest sample on this shelf contains no patients and no mania cases: its alpha and correlations describe how the items behave in students, and they cannot support the derivation's sensitivity/specificity claim. The record prints no MeSH.

Source: Kim BN et al. Initial Psychometric Properties of the Korean Altman Self-Rating Mania Scale: Preliminary Validation Study in a Non-Clinical Sample. Psychiatry investigation. 2017. PMID: 29042880. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis — 3 reports (105 derivation patients + 74 Spanish bipolar patients + 1,091 non-clinical undergraduates): a developer head carrying the only accuracy figures, a coefficient-free patient transport, and a non-clinical large-N limb

Study: Synthesis

Population: Composition: Altman 1997 derivation (105 patients; test–retest in a further 30) + Alvarez Mas 2005 Spanish validation (74 bipolar patients) + Kim & Kwon 2017 Korean validation (1,091 non-clinical undergraduates). Total documented N = 1,270, of whom 1,091 are non-clinical — the pooled total is printed only with that split attached.

Summary: Synthesis — 3 reports (105 derivation patients + 74 Spanish bipolar patients + 1,091 non-clinical undergraduates): a developer head carrying the only accuracy figures, a coefficient-free patient transport, and a non-clinical large-N limb

Result: The derivation supports the ASRM as a brief self-rating mania screen: mania-subscale correlations of 0.718 (MRS) and 0.766 (CARS-M), and sensitivity 85.5% / specificity 87.3% at a score >5. The Spanish limb affirms reliability, concurrent correlation and discrimination in patients without printing a single coefficient. The Korean limb affirms internal consistency (α 0.73) and convergent correlations in students. Factor structure is not stable across the base (three factors at derivation, one factor in both transports). The stamp is MEASUREMENT PROPERTIES at supported-as-a-screen weight, resting on the derivation's figures and the transports' direction — no stronger claim is honest on this composition.

Watch out: No responsiveness or longitudinal limb exists here, and no independent patient sample has ever printed an accuracy coefficient for the >5 cut-off in this base — the cut-off's performance outside the developer's own cohort is unverified in this composition.

Source: Synthesis of the reports carded above; no additional source.