SourceMed · Shelf #8864 in the ask interface

The QUiPP app for predicting preterm birth — a full chain in 5 reports: derivation AUCs 0.77–0.99, v.2 validations to 0.96, independent European validation 0.84/0.74 with high-risk underestimation, and a cluster-randomised rollout that changed unnecessary management not at all (11.3% vs 11.5%, OR 0.97)

Shelf #8864 · Women’s health

PREDICTIVE PERFORMANCE — accurate prediction, null implementation effect, printed together at full weight: derivation AUCs ranged 0.77–0.99 across five delivery outcomes; the v.2 symptomatic validation (n = 506) gave AUCs of 0.96 (<30 weeks), 0.85 (<34), 0.77 (<37), 0.91 (<1 week) and 0.92 (<2 weeks) for the risk-factors-plus-qfFN model; the v.2 asymptomatic validation AUCs ran 0.68–0.90 depending on test combination and horizon; the independent European external validation (1,432 women) found AUC 0.84 (European cohort) and 0.74 (Dutch cohort) for delivery within 1 week with the combined model, 0.91 for birth <30 weeks, and systematic underestimation of risk in higher-risk women; and the 13-unit cluster-randomised EQUIPTT trial (1,872 women) found unnecessary management of 11.3% with the app vs 11.5% without (OR 0.97, 95% CI 0.66–1.42 — a relative measure, labelled as such).

Stamped: 2026-11-28.

Evidence published: 2016–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In pregnant women at risk of spontaneous preterm birth, how accurately does the QUiPP app (quantitative fetal fibronectin and/or cervical length combined with clinical risk factors in parametric survival models) predict delivery — at its prototype derivation in asymptomatic high-risk women, in the v.2 symptomatic and asymptomatic model validations, on independent external validation in three European cohorts, and what happened when its use was randomised in the EQUIPTT cluster trial?

Balance of the evidence

Composition: 1 prototype derivation/internal validation + 2 programme v.2 development/validations in different spectra (symptomatic; asymptomatic) + 1 independent external validation (three European cohorts) + 1 cluster-randomised impact trial. Four of five anchors are the developing programme's own work; independence rests on Fischer 2025 alone, which is also the anchor that found calibration failure at high risk. The EQUIPTT null primary outcome and the app's AUC 0.90 in the same report print together — prediction accuracy and management impact are separate claims and neither is averaged into the other. Spectra print per card and are never merged; counting units differ (women vs visits in Watson 2020) and print as the records state them. Cross-points in prose only: quantitative fetal fibronectin test accuracy is slate 44's S44-1-10 question and cervical length alone is pack #8863; no anchor is shared with either. Registry ID: ISRCTN17846337 (EQUIPTT), from the record's databank list; the other four records carry no registry ID.

MeSH: Adult · Area Under Curve · Asymptomatic Diseases · Bayes Theorem · Cervical Length Measurement* · Cervix Uteri/diagnostic imaging* · Decision Support Techniques* · Female · Fibronectins/analysis* · Humans · Pregnancy · Pregnancy, High-Risk · Premature Birth/epidemiology* · Prospective Studies · ROC Curve · Risk Assessment · Algorithms · Biomarkers/analysis · Cervical Length Measurement · Fetus/chemistry · Fibronectins/analysis · Gestational Age · Infant, Newborn · Mobile Applications* · Predictive Value of Tests · Pregnancy, High-Risk* · Premature Birth/prevention & control* · Prenatal Diagnosis/methods* · Risk Assessment/methods* · Risk Factors · Fibronectins*/analysis · Premature Birth*/diagnosis · Belgium · Retrospective Studies · Netherlands · Risk Assessment/methods · Europe · Reproducibility of Results · Cohort Studies · Obstetric Labor, Premature/diagnosis*,prevention & control*

Cards (6)

Card 1 — Kuhrt QUiPP prototype derivation 2016 (Ultrasound in Obstetrics & Gynecology — 1,249 asymptomatic high-risk women at preterm surveillance clinics; development 624, validation 625): the selected log-normal survival model (cervical length, √quantitative fetal fibronectin, previous spontaneous preterm birth / preterm prelabour rupture of membranes) gave AUCs of 0.77–0.99 across delivery <30, <34 and <37 weeks and within 2 and 4 weeks — the developers' own derivation

Study: Model development and internal validation study (primary report) — programme-labelled: the score developers' own derivation

Population: 1,249 women at high risk for spontaneous preterm birth attending preterm surveillance clinics, prospectively collected; clinicians were blinded to quantitative fetal fibronectin measurements (aware of qualitative results). Model developed on the first 624 consecutive women, validated on the subsequent 625.

Summary: Kuhrt QUiPP prototype derivation 2016 (Ultrasound in Obstetrics & Gynecology — 1,249 asymptomatic high-risk women at preterm surveillance clinics; development 624, validation 625): the selected log-normal survival model (cervical length, √quantitative fetal fibronectin, previous spontaneous preterm birth / preterm prelabour rupture of membranes) gave AUCs of 0.77–0.99 across delivery <30, <34 and <37 weeks and within 2 and 4 weeks — the developers' own derivation

Result: The final selected model used a log-normal survival curve with cervical length, √qfFN and previous spontaneous preterm birth/preterm prelabour rupture of membranes as predictors. Predictive statistics were similar for training and validation sets, and areas under the receiver-operating-characteristics curves ranged from 0.77 to 0.99 across all five delivery outcomes (<30, <34 and <37 weeks; within 2 and 4 weeks of testing). This algorithm was incorporated into an app (QUiPP).

Watch out: Internal validation on the next 625 women from the same clinics is not external validation: the 0.77–0.99 AUC range's top end comes from the developers' own population and prints with that provenance. The record is typed 'Validation Study' at PubMed.

Source: Kuhrt K et al. Development and validation of a tool incorporating cervical length and quantitative fetal fibronectin to predict spontaneous preterm birth in asymptomatic high-risk women. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2016. PMID: 25846437. Registry ID: none in the record. MeSH: Adult · Area Under Curve · Asymptomatic Diseases · Bayes Theorem · Cervical Length Measurement* · Cervix Uteri/diagnostic imaging* · Decision Support Techniques* · Female · Fibronectins/analysis* · Humans · Pregnancy · Pregnancy, High-Risk · Premature Birth/epidemiology* · Prospective Studies · ROC Curve · Risk Assessment

Card 2 — Carter QUiPP v.2 symptomatic validation 2020 (Ultrasound in Obstetrics & Gynecology — four prospective cohorts at 16 UK hospitals; training n = 1,032, validation n = 506): in validation, the risk-factors-plus-qfFN model gave AUCs of 0.96 (<30 weeks), 0.85 (<34), 0.77 (<37), 0.91 (within 1 week) and 0.92 (within 2 weeks)

Study: Model development and validation study (primary report) — programme-labelled v.2 derivation/validation

Population: Pregnant women at 23+0 to 34+6 weeks with symptoms of threatened preterm labour, recruited in four prospective cohort studies at 16 UK hospitals (October 2010–October 2017); training set n = 1,032, validation set n = 506.

Summary: Carter QUiPP v.2 symptomatic validation 2020 (Ultrasound in Obstetrics & Gynecology — four prospective cohorts at 16 UK hospitals; training n = 1,032, validation n = 506): in validation, the risk-factors-plus-qfFN model gave AUCs of 0.96 (<30 weeks), 0.85 (<34), 0.77 (<37), 0.91 (within 1 week) and 0.92 (within 2 weeks)

Result: Parametric survival models were developed for three predictor combinations (risk factors + qfFN, risk factors + cervical length, risk factors + both). Predictive statistics were similar between training and validation sets at most time points. In the validation set all three algorithms had good accuracy, particularly risk factors plus qfFN alone: AUC 0.96 at <30 weeks, 0.85 at <34 weeks, 0.77 at <37 weeks, 0.91 at <1 week from testing and 0.92 at <2 weeks from testing.

Watch out: A symptomatic threatened-preterm-labour spectrum — these AUCs do not describe the asymptomatic population of the companion v.2 report (PMID 31325332), and the two are printed as different spectra, never merged. Still the developing programme's own cohorts.

Source: Carter J et al. Development and validation of predictive models for QUiPP App v.2: tool for predicting preterm birth in women with symptoms of threatened preterm labor. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2020. PMID: 31385343. Registry ID: none in the record. MeSH: Adult · Algorithms · Area Under Curve · Bayes Theorem · Biomarkers/analysis · Cervical Length Measurement · Female · Fetus/chemistry · Fibronectins/analysis · Gestational Age · Humans · Infant, Newborn · Mobile Applications* · Predictive Value of Tests · Pregnancy · Pregnancy, High-Risk* · Premature Birth/prevention & control* · Prenatal Diagnosis/methods* · Prospective Studies · ROC Curve · Risk Assessment/methods* · Risk Factors

Card 3 — Watson QUiPP v.2 asymptomatic validation 2020 (Ultrasound in Obstetrics & Gynecology — prospective secondary analysis, 13 UK preterm clinics; training 1,803 women / 3,878 visits, validation 904 women / 1,400 visits): AUCs ran 0.75–0.90 (qfFN + cervical length combined), 0.68–0.90 (qfFN alone) and 0.71–0.87 (cervical length alone) across delivery <30/<34/<37 weeks and within 1/2/4 weeks

Study: Model development and validation study (primary report; prospective secondary analysis) — programme-labelled v.2 derivation/validation; a different spectrum from PMID 31385343

Population: Asymptomatic women at high risk of spontaneous preterm birth recruited in 13 UK preterm birth clinics, offered longitudinal qfFN testing every 2–4 weeks and/or transvaginal cervical-length measurement between 18+0 and 36+6 weeks; training set 1,803 women (3,878 visits), validation set 904 women (1,400 visits).

Summary: Watson QUiPP v.2 asymptomatic validation 2020 (Ultrasound in Obstetrics & Gynecology — prospective secondary analysis, 13 UK preterm clinics; training 1,803 women / 3,878 visits, validation 904 women / 1,400 visits): AUCs ran 0.75–0.90 (qfFN + cervical length combined), 0.68–0.90 (qfFN alone) and 0.71–0.87 (cervical length alone) across delivery <30/<34/<37 weeks and within 1/2/4 weeks

Result: All three algorithms demonstrated high accuracy across the six time points, with AUCs between 0.75 and 0.90 for qfFN and cervical length combined, between 0.68 and 0.90 for qfFN alone and between 0.71 and 0.87 for cervical length alone; differences between the three algorithms were not statistically significant. Calibration showed no significant difference between expected and observed rates of spontaneous preterm birth within 4 weeks, except a slight overestimation of risk with cervical length at 22+0–25+6 weeks.

Watch out: The counting unit mixes women and visits (3,878 visits in 1,803 training women) and prints as such. The asymptomatic AUCs run lower than the symptomatic model's (0.68–0.90 vs up to 0.96) — spectrum, not app version, is the likely driver, and no anchor adjudicates.

Source: Watson HA et al. Development and validation of predictive models for QUiPP App v.2: tool for predicting preterm birth in asymptomatic high-risk women. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2020. PMID: 31325332. Registry ID: none in the record. MeSH: Adult · Algorithms · Area Under Curve · Bayes Theorem · Biomarkers/analysis · Cervical Length Measurement · Female · Fetus/chemistry · Fibronectins/analysis · Gestational Age · Humans · Infant, Newborn · Mobile Applications* · Predictive Value of Tests · Pregnancy · Pregnancy, High-Risk* · Premature Birth/prevention & control* · Prenatal Diagnosis/methods* · Prospective Studies · ROC Curve · Risk Assessment/methods* · Risk Factors

Card 4 — Fischer independent external validation 2025 (Ultrasound in Obstetrics & Gynecology — three European cohorts of symptomatic women: prospective 5-country n = 452, Dutch retrospective n = 581, Belgian retrospective n = 399): combined-model AUC for delivery within 1 week was 0.84 (European) and 0.74 (Dutch), 0.80 for the cervical-length-only model in Belgium, 0.91 for birth <30 weeks — and risk was generally underestimated in higher-risk women

Study: External validation study (primary report) — the shelf's only fully independent anchor

Population: Pregnant women at 23–34 weeks with symptoms of threatened preterm birth attending tertiary care in Europe (2012–2023): a prospective multicentre cohort across five countries (n = 452), a retrospective single-centre Dutch cohort (n = 581) and a retrospective single-centre Belgian cohort (n = 399; cervical-length-only model validated there, no fibronectin kit being available).

Summary: Fischer independent external validation 2025 (Ultrasound in Obstetrics & Gynecology — three European cohorts of symptomatic women: prospective 5-country n = 452, Dutch retrospective n = 581, Belgian retrospective n = 399): combined-model AUC for delivery within 1 week was 0.84 (European) and 0.74 (Dutch), 0.80 for the cervical-length-only model in Belgium, 0.91 for birth <30 weeks — and risk was generally underestimated in higher-risk women

Result: For spontaneous preterm birth within 1 week, the combined cervical-length-plus-qfFN model gave AUC 0.84 (95% CI 0.79–0.89) in the European cohort and 0.74 (0.66–0.83) in the Dutch cohort; the cervical-length-only model gave 0.80 (0.75–0.85) in Belgium. Performance was greater for shorter-term outcomes; the highest AUC (0.91, 0.86–0.95) was for birth <30 weeks in the European cohort with the combined model. Calibration was excellent for patients with negligible risk, but for women at greater risk the risk was generally underestimated compared with the observed event rate.

Watch out: Independence cuts both ways: this is the anchor that found the app's discrimination lower abroad (0.74 in the Dutch cohort) and its calibration failing exactly where it matters — underestimating risk in higher-risk women. A reassuring QUiPP output travels better than a high one.

Source: Fischer AM et al. External validation of QUiPP App in three independent European cohorts of symptomatic women. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2025. PMID: 40568915. Registry ID: none in the record. MeSH: Humans · Female · Pregnancy · Fibronectins*/analysis · Adult · Premature Birth*/diagnosis · Prospective Studies · Belgium · Retrospective Studies · Netherlands · Cervical Length Measurement* · Risk Assessment/methods · Predictive Value of Tests · Risk Factors · Europe · Gestational Age · ROC Curve · Reproducibility of Results · Cohort Studies

Card 5 — Watson EQUIPTT cluster-randomised trial 2021 (PLOS Medicine — 13 maternity units, 1,872 women with threatened preterm labour; ISRCTN17846337): unnecessary management was 11.3% (84/741) at QUiPP sites vs 11.5% (126/1,094) at control sites (OR 0.97, 95% CI 0.66–1.42 — a relative measure) — the app changed management not at all, in the same trial whose embedded validation found AUC 0.90 for delivery within 7 days

Study: Cluster-randomised trial (impact report, counted as an impact report, never as a validation)

Population: 1,872 pregnant women at 23+0 to 34+6 weeks with symptoms of preterm labour across 13 maternity units in South and Eastern England (762 intervention, 1,111 control in the analysis population); intervention sites used the QUiPP app with admission, corticosteroids and transfer advised above a >5% risk of delivery within 7 days.

Summary: Watson EQUIPTT cluster-randomised trial 2021 (PLOS Medicine — 13 maternity units, 1,872 women with threatened preterm labour; ISRCTN17846337): unnecessary management was 11.3% (84/741) at QUiPP sites vs 11.5% (126/1,094) at control sites (OR 0.97, 95% CI 0.66–1.42 — a relative measure) — the app changed management not at all, in the same trial whose embedded validation found AUC 0.90 for delivery within 7 days

Result: The composite primary outcome, unnecessary management of threatened preterm labour, was 11.3% (84/741) at intervention sites vs 11.5% (126/1,094) at control sites (odds ratio 0.97, 95% CI 0.66–1.42, p = 0.883 — a relative measure). Unnecessary management largely consisted of unnecessary admissions (10.7% vs 10.8%). Had the QUiPP risk been used per protocol, unnecessary management would have been 7.4% (43/578) vs 9.9% (134/1,351) (OR 0.72, 0.45–1.16). The trial's external validation of the app confirmed it was highly predictive of delivery in 7 days (ROC area 0.90, 0.85–0.95). Control sites frequently used qfFN and did not follow UK national guidance.

Watch out: The null primary outcome prints at full weight beside the AUC of 0.90 from the same report: prediction and impact part company here, partly because control sites were already testing with qfFN outside guidance — a contamination the authors themselves name. The per-protocol figures (OR 0.72) are a hypothetical and lend the stamp nothing.

Source: Watson HA et al. Evaluating the use of the QUiPP app and its impact on the management of threatened preterm labour: A cluster randomised trial. PLoS medicine. 2021. PMID: 34228735. Registry ID: ISRCTN17846337. MeSH: Adult · Female · Humans · Mobile Applications* · Obstetric Labor, Premature/diagnosis*,prevention & control* · Pregnancy

Card 6 — Synthesis — accurate prediction, null implementation effect: derivation AUCs 0.77–0.99, v.2 symptomatic AUCs up to 0.96, independent European AUCs 0.84 / 0.74 for delivery within 1 week with risk underestimated at high risk, and a 13-unit cluster trial in which the app changed unnecessary management not at all (OR 0.97, relative)

Study: Synthesis

Population: Composition: 1 prototype derivation/internal validation (Kuhrt 2016, 1,249 asymptomatic high-risk women) + 2 programme v.2 development/validations in different spectra (Carter 2020 symptomatic, training 1,032 / validation 506; Watson 2020 asymptomatic, training 1,803 women / validation 904 women) + 1 independent external validation (Fischer 2025, three European cohorts totalling 1,432 women) + 1 cluster-randomised impact trial (EQUIPTT 2021, 13 units, 1,872 women). Four of five anchors are the developing programme's own; independence rests on Fischer 2025 alone. Refused: nothing was refused on this row; the fetal fibronectin test-accuracy question is slate 44's S44-1-10 and cervical length alone is pack #8863 — cross-pointed in prose only, no anchor shared.

Summary: Synthesis — accurate prediction, null implementation effect: derivation AUCs 0.77–0.99, v.2 symptomatic AUCs up to 0.96, independent European AUCs 0.84 / 0.74 for delivery within 1 week with risk underestimated at high risk, and a 13-unit cluster trial in which the app changed unnecessary management not at all (OR 0.97, relative)

Result: The chain is complete and its two ends disagree in kind, not in number. Prediction: AUCs of 0.77–0.99 at derivation, 0.96/0.85/0.77/0.91/0.92 across the five symptomatic v.2 outcomes, 0.68–0.90 across asymptomatic test combinations, and 0.84 (European) / 0.74 (Dutch) for delivery within 1 week on independent validation, with the highest figure (0.91) for birth <30 weeks. Calibration: excellent at negligible risk, generally underestimating risk in higher-risk women (Fischer 2025). Impact: in EQUIPTT, unnecessary management was 11.3% with the app vs 11.5% without (OR 0.97, 95% CI 0.66–1.42, relative), while the same trial's embedded validation gave AUC 0.90 for delivery within 7 days. The stamp therefore carries both claims at full weight: the app predicts; its randomised rollout did not change management.

Watch out: A developer weighing deployment should hold the two failure modes apart: calibration failure at high risk (Fischer) is a property of the model; the null trial result is partly a property of a control arm already using qfFN outside guidance. Neither rescues the other.

Source: Synthesis of the reports carded above; no additional source.