SourceMed · Shelf #8869 in the ask interface
Abdominal palpation for AAA — 4 reports (15-study RCE pool; 200-subject blinded primary; 1,731-patient Japanese cohort): pooled LR+ 12.0–15.6 in screening spectra vs LR+ 2.7 blinded, sensitivity 52–68% overall rising to 76–100% only for aneurysms ≥5 cm in slim abdomens
Shelf #8869 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — size- and girth-bound: palpation rules in large aneurysms when positive (pooled LR+ 12.0–15.6 in screening spectra, relative measures) but misses about half of all AAAs (sensitivity 52–68% in the two large primaries) and cannot exclude the diagnosis; sensitivity reaches 76–100% only for aneurysms ≥5 cm in slim abdomens, inter-observer agreement is only moderate (κ 0.53), and the RCE pool's LR+ and the blinded primary's LR+ (12.0 vs 2.7, different spectra) both print at full weight.
Stamped: 2026-11-28.
Evidence published: 1999–2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults not previously known to have an abdominal aortic aneurysm, how accurately does abdominal palpation — feeling for abnormal widening of the aortic pulsation — detect AAA against ultrasonography, and how do aneurysm diameter and abdominal girth change its performance?
Balance of the evidence
Composition: 4 reports — Lederle & Simel 1999 RCE meta-analysis (15 studies), Fink 2000 blinded primary (200 subjects, 400 examinations; programme-linked to the RCE), Lynch 2004 narrative range review, and Fukuda 2015 multicentre cohort (1,731 patients). The RCE pool (screening spectrum) and Fink (known-status cohort) disagree on LR+ by more than fourfold; the difference is printed as spectrum-shaped, not resolved. Counting units differ (studies, subjects, examinations, patients) and print per card. Cross-point in prose only: ED bedside ultrasound for AAA is pack #8519, an imaging question. No carded record carries a registry ID; no anchor studies palpation in suspected rupture.
MeSH: Aneurysm, Ruptured/diagnosis · Aortic Aneurysm, Abdominal/diagnosis*,diagnostic imaging · Humans · Palpation* · Physical Examination · Sensitivity and Specificity · Ultrasonography · Abdomen* · Aged · Aged, 80 and over · Diagnosis, Differential · Female · Male · Middle Aged · Predictive Value of Tests · Abdomen · Aortic Aneurysm, Abdominal/diagnosis* · Diagnostic Errors · Physical Examination/methods* · Aortic Aneurysm*/complications,diagnostic imaging,epidemiology · Asian People · Cohort Studies · Hypertension*/complications,diagnostic imaging,epidemiology · Japan/epidemiology · Prevalence · Risk Factors
Cards (5)
Card 1 — Lederle & Simel Rational Clinical Examination 1999 (JAMA — 15 studies of palpation vs ultrasound pooled): sensitivity rises with diameter — 29% for AAA 3.0–3.9 cm, 50% for 4.0–4.9 cm, 76% for ≥5.0 cm; for AAA ≥3.0 cm LR+ 12.0 (7.4–19.5) and LR− 0.72 (0.65–0.81); for ≥4.0 cm LR+ 15.6 (8.6–28.5) and LR− 0.51 (0.38–0.67); positive predictive value 43%
Study: Rational Clinical Examination meta-analysis (synthesis, counted as a synthesis)
Population: Patients not previously known to have an abdominal aortic aneurysm, screened with both abdominal palpation and ultrasound, in 15 studies pooled by this Rational Clinical Examination review (typed 'Meta-Analysis' in the record).
Summary: Lederle & Simel Rational Clinical Examination 1999 (JAMA — 15 studies of palpation vs ultrasound pooled): sensitivity rises with diameter — 29% for AAA 3.0–3.9 cm, 50% for 4.0–4.9 cm, 76% for ≥5.0 cm; for AAA ≥3.0 cm LR+ 12.0 (7.4–19.5) and LR− 0.72 (0.65–0.81); for ≥4.0 cm LR+ 15.6 (8.6–28.5) and LR− 0.51 (0.38–0.67); positive predictive value 43%
Result: The only examination manoeuvre of demonstrated value is abdominal palpation to detect abnormal widening of the aortic pulsation; palpation has not been reported to precipitate rupture. Pooled sensitivity increased significantly with AAA diameter (P<.001): 29% for 3.0–3.9 cm, 50% for 4.0–4.9 cm and 76% for ≥5.0 cm. For AAA ≥3.0 cm, LR+ was 12.0 (95% CI 7.4–19.5) and LR− 0.72 (0.65–0.81); for ≥4.0 cm, LR+ 15.6 (8.6–28.5) and LR− 0.51 (0.38–0.67) — likelihood ratios are relative measures and print labelled as such. The positive predictive value of palpation for AAA ≥3.0 cm was 43%. Limited data suggest abdominal obesity decreases sensitivity.
Watch out: A screening-spectrum pool: its LR+ of 12.0–15.6 describes palpation in people not known to have AAA, and its LR− (0.72 at ≥3.0 cm) is far too weak to exclude the diagnosis — the review itself says palpation cannot be relied on to exclude AAA, especially if rupture is a possibility. No anchor on this shelf studies palpation in suspected rupture.
Source: Lederle FA et al. The rational clinical examination. Does this patient have abdominal aortic aneurysm?. JAMA. 1999. PMID: 9892455. Registry ID: none in the record. MeSH: Aneurysm, Ruptured/diagnosis · Aortic Aneurysm, Abdominal/diagnosis*,diagnostic imaging · Humans · Palpation* · Physical Examination · Sensitivity and Specificity · Ultrasonography
Card 2 — Fink blinded primary study 2000 (Archives of Internal Medicine — 200 subjects (99 with, 101 without AAA on prior ultrasound), each examined by two internists blinded to diagnosis and to each other): overall sensitivity 68%, specificity 75%, LR+ 2.7, LR− 0.43; inter-observer agreement 77% (κ 0.53); sensitivity 91% when abdominal girth was <100 cm vs 53% at ≥100 cm, and 100% for AAA ≥5.0 cm in slim subjects (12 examinations)
Study: Blinded diagnostic-accuracy study (primary report) — programme-linked to the RCE carded above (Lederle group), printed as such
Population: 200 subjects aged 51–88 years — 99 with and 101 without AAA as determined by previous ultrasound — each examined by 2 internists blinded to each other's findings and to the ultrasound diagnosis (400 examinations).
Summary: Fink blinded primary study 2000 (Archives of Internal Medicine — 200 subjects (99 with, 101 without AAA on prior ultrasound), each examined by two internists blinded to diagnosis and to each other): overall sensitivity 68%, specificity 75%, LR+ 2.7, LR− 0.43; inter-observer agreement 77% (κ 0.53); sensitivity 91% when abdominal girth was <100 cm vs 53% at ≥100 cm, and 100% for AAA ≥5.0 cm in slim subjects (12 examinations)
Result: Overall accuracy of abdominal palpation: sensitivity 68% (95% CI 60–76%), specificity 75% (68–82%), LR+ 2.7 (2.0–3.6), LR− 0.43 (0.33–0.56). Interobserver agreement was 77% (kappa 0.53). Sensitivity rose with diameter (61% at 3.0–3.9 cm; 69% at 4.0–4.9 cm; 82% at ≥5.0 cm) and was 91% when abdominal girth was <100 cm vs 53% at ≥100 cm (P<.001); when girth was <100 cm and the AAA was ≥5.0 cm, sensitivity was 100% (12 examinations). Factors independently associated with correct findings included AAA diameter (OR 1.95 per cm), abdominal girth (OR 0.90 per cm) and the examiner's assessment that the abdomen was not tight (OR 2.68) — odds ratios are relative measures.
Watch out: The honest counterweight to the RCE pool: in a known-status cohort the same group's blinded examiners produced LR+ 2.7, not 12.0 — spectrum (screening vs known-status) explains much of the gap, and both figures print. The 100% sensitivity cell rests on 12 examinations. Inter-observer agreement is only moderate (κ 0.53).
Source: Fink HA et al. The accuracy of physical examination to detect abdominal aortic aneurysm. Archives of internal medicine. 2000. PMID: 10737283. Registry ID: none in the record. MeSH: Abdomen* · Aged · Aged, 80 and over · Aortic Aneurysm, Abdominal/diagnosis*,diagnostic imaging · Diagnosis, Differential · Female · Humans · Male · Middle Aged · Palpation* · Predictive Value of Tests · Sensitivity and Specificity · Ultrasonography
Card 3 — Lynch literature review 2004 (Accident and Emergency Nursing — prospective studies of examination vs ultrasound): sensitivity ranged 33–100%, specificity 75–100% and positive predictive value 14–100% across studies, detection rising with diameter, age, male sex, examiner experience and thin habitus; the conclusion is that examination cannot exclude AAA
Study: Literature review (synthesis, counted as a narrative range review, printed as such; typed 'Review' and 'Validation Study' in the record)
Population: Prospective studies comparing physical examination for non-ruptured AAA against ultrasonography as the gold standard, retrieved by comprehensive literature search (the record's abstract states no pooled N; this is a narrative range review).
Summary: Lynch literature review 2004 (Accident and Emergency Nursing — prospective studies of examination vs ultrasound): sensitivity ranged 33–100%, specificity 75–100% and positive predictive value 14–100% across studies, detection rising with diameter, age, male sex, examiner experience and thin habitus; the conclusion is that examination cannot exclude AAA
Result: The sensitivity of physical examination in the diagnosis of AAA ranges from 33% to 100%, specificity from 75% to 100%, and positive predictive value from 14% to 100%. Detection rates increase with increasing aortic diameter, increasing age, male sex, presence of recognisable risk factors, examination by an experienced clinician, examination directed specifically towards AAA detection, prevalence of AAA in the study population, and thin patients. The author concludes clinical examination cannot be relied upon to exclude AAA, and that obese patients with a suggestive history should be referred for ultrasound.
Watch out: Ranges spanning 33–100% sensitivity are a statement about heterogeneity across small studies, not an accuracy estimate — no pooled figure exists in this record and none may be constructed from it.
Source: Lynch RM et al. Accuracy of abdominal examination in the diagnosis of non-ruptured abdominal aortic aneurysm. Accident and emergency nursing. 2004. PMID: 15041011. Registry ID: none in the record. MeSH: Abdomen · Aged · Aged, 80 and over · Aortic Aneurysm, Abdominal/diagnosis* · Diagnostic Errors · Female · Humans · Male · Physical Examination/methods* · Sensitivity and Specificity · Ultrasonography
Card 4 — Fukuda multicentre cohort 2015 (Circulation Journal — 1,731 Japanese hypertensive patients aged >60 in 20 institutions, palpation then pocket ultrasound): AAA in 69 (4.1%); palpation missed 33 (sensitivity 52%), rising to 75% for AAA >40 mm
Study: Multicentre cohort study (primary report)
Population: 1,731 patients with hypertension aged >60 years enrolled at 20 collaborating institutions in Japan; abdominal palpation was performed on physical examination and a pocket-sized ultrasound device used to confirm AAA (the aorta was well visualised in 1,692 patients, 98%).
Summary: Fukuda multicentre cohort 2015 (Circulation Journal — 1,731 Japanese hypertensive patients aged >60 in 20 institutions, palpation then pocket ultrasound): AAA in 69 (4.1%); palpation missed 33 (sensitivity 52%), rising to 75% for AAA >40 mm
Result: AAA was discovered in 69 patients (4.1%); advanced age and male sex were independent risk factors, and prevalence reached 9.2% in males and 5.7% in females aged ≥80 years. Overall, 33 cases of AAA were missed on abdominal palpation (sensitivity 52%), whereas for AAAs >40 mm the sensitivity was 75%. The authors conclude physical examination detects large, but not small, AAAs.
Watch out: The pocket-ultrasound device is the reference standard here and is counted nowhere as an index test. A hypertensive, elderly, Japanese screening spectrum — its 4.1% prevalence and 52% sensitivity do not transport to unselected or symptomatic populations.
Source: Fukuda S et al. Multicenter investigations of the prevalence of abdominal aortic aneurysm in elderly Japanese patients with hypertension. Circulation journal : official journal of the Japanese Circulation Society. 2015. PMID: 25746535. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Aortic Aneurysm*/complications,diagnostic imaging,epidemiology · Asian People · Cohort Studies · Female · Humans · Hypertension*/complications,diagnostic imaging,epidemiology · Japan/epidemiology · Male · Prevalence · Risk Factors · Ultrasonography
Card 5 — Synthesis — size- and girth-bound across 4 reports (1 RCE pool + 1 blinded primary + 1 narrative review + 1 multicentre cohort of 1,731): palpation rules in large aneurysms when positive in screening spectra (pooled LR+ 12.0–15.6) but misses about half of all AAAs (sensitivity 52–68% in the two large primaries) and cannot exclude the diagnosis; sensitivity reaches 76–100% only for aneurysms ≥5 cm in slim abdomens
Study: Synthesis
Population: Composition: Lederle & Simel 1999 RCE (15 studies pooled) + Fink 2000 (200 subjects, 400 blinded examinations; programme-linked to the RCE — Lederle group) + Lynch 2004 (narrative range review) + Fukuda 2015 (1,731 hypertensive patients >60). Refused: nothing was refused on this row. Cross-point in prose only: ED bedside ultrasound accuracy for AAA is pack #8519 — an imaging question; the homed AAA screening-programme packs ask different questions.
Summary: Synthesis — size- and girth-bound across 4 reports (1 RCE pool + 1 blinded primary + 1 narrative review + 1 multicentre cohort of 1,731): palpation rules in large aneurysms when positive in screening spectra (pooled LR+ 12.0–15.6) but misses about half of all AAAs (sensitivity 52–68% in the two large primaries) and cannot exclude the diagnosis; sensitivity reaches 76–100% only for aneurysms ≥5 cm in slim abdomens
Result: The RCE pool and the largest blinded primary disagree sharply on LR+ (12.0 vs 2.7) and both print: the pool is a screening spectrum (patients not known to have AAA), the primary a known-status cohort examined blind — spectrum, not examiner skill, is the printed explanation, and no anchor adjudicates further. What all four reports share is the gradient: sensitivity climbs with diameter (29% → 50% → 76% by size band in the pool; 52% overall → 75% above 40 mm in Fukuda; 61% → 82% by band in Fink) and falls with girth (91% below 100 cm vs 53% at or above it, Fink), with only moderate inter-observer agreement (κ 0.53). Palpation has not been reported to precipitate rupture (RCE). The stamp therefore reads: a positive palpation in a slim abdomen is strong evidence for a large AAA; a negative palpation excludes nothing.
Watch out: No anchor studies palpation in suspected rupture, where the stakes of a false negative are highest — the shelf's silence on that spectrum should not be read as reassurance.
Source: Synthesis of the reports carded above; no additional source.