Clinical examination for lower-extremity PAD — 4 reports (17-study RCE; 2,736-person screening study; 315-leg primary-care study; IWGDF diabetes review limb): pulses and femoral bruit LR ≈3–5, normal examination LR ≈0.38, but examination cannot exclude PAD in diabetic foot spectra (NLR 0.75)
Shelf #8870 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — moderate and asymmetric: abnormal pulses or a femoral bruit raise PAD probability (LR ≈3–5, relative measures), and a fully normal pulse examination lowers it (LR ≈0.38–0.39 in the RCE pool; LR− 0.16 for absent-pulse palpation in one primary-care study), but in diabetic foot spectra the examination cannot reliably exclude PAD (negative LR 0.75, one study inside a device-test review); combinations of findings added nothing beyond individual findings in the RCE pool.
Stamped: 2026-11-28.
Evidence published: 2006–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In asymptomatic adults and in patients with leg symptoms, how accurately do the elements of the clinical examination — claudication history, pedal pulse palpation, femoral and other bruits, cool skin and trophic changes — identify lower-extremity peripheral arterial disease against ankle-brachial index, duplex or angiography?
Balance of the evidence
Composition: 4 reports — Khan 2006 RCE (17 studies; asymptomatic and symptomatic spectra printed apart, never merged), Cournot 2007 prospective screening study (2,736 asymptomatic subjects), Herráiz-Adillo 2018 primary-care accuracy study (158 subjects, 315 legs — the counting unit is legs) and Forsythe/IWGDF 2020 systematic review (15 studies, 1,563 patients), of which only the clinical-examination limb is carded (a shared report, printed as shared; its ABI/toe-index/oximetry/waveform limbs are device tests counted nowhere). Cournot's carotid-bruit limb is a negative limb printed as such; it bounds but does not reopen pack #7874's symptomatic carotid question. No carded record carries a registry ID.
MeSH: Ankle/blood supply · Atherosclerosis/diagnosis · Auscultation · Blood Pressure Determination/methods* · Brachial Artery/physiology* · Diagnosis, Differential · Humans · Intermittent Claudication/diagnosis*,etiology · Lower Extremity · Oscillometry · Peripheral Vascular Diseases/diagnosis*,physiopathology · Physical Examination/methods* · Point-of-Care Systems · Pulse · Ultrasonography, Doppler · Adult · Aged · Aged, 80 and over · Atherosclerosis/diagnosis*,diagnostic imaging,physiopathology · Blood Pressure · Brachial Artery/physiopathology · Carotid Stenosis/diagnosis*,diagnostic imaging,physiopathology · Female · Femoral Artery*/diagnostic imaging,physiopathology · Likelihood Functions · Male · Mass Screening/methods* · Middle Aged · Odds Ratio · Palpation · Peripheral Vascular Diseases/diagnosis*,diagnostic imaging,physiopathology · Physical Examination* · Predictive Value of Tests · Prospective Studies · Reproducibility of Results · Research Design · Sensitivity and Specificity · Ultrasonography · False Negative Reactions · Leg/pathology* · Observer Variation · Peripheral Arterial Disease/diagnosis* · Primary Health Care/methods* · Diabetes Mellitus/physiopathology* · Diabetic Foot/complications*,epidemiology · Peripheral Arterial Disease/diagnosis*,etiology · Practice Guidelines as Topic/standards* · Practice Patterns, Physicians'/standards* · Prognosis
Cards (5)
Card 1 — Khan Rational Clinical Examination 2006 (JAMA — 17 studies vs ankle-brachial index, duplex or angiography): in asymptomatic patients the most useful findings were claudication (LR 3.30), femoral bruit (LR 4.80) and any pulse abnormality (LR 3.10), and no finding's absence lowered the likelihood of any PAD; in symptomatic patients, cool skin (LR 5.90), at least one bruit (LR 5.60) and any palpable pulse abnormality (LR 4.70), with absence of all bruits (LR 0.39) or of any pulse abnormality (LR 0.38) reducing likelihood; combinations added nothing beyond individual findings
Study: Rational Clinical Examination systematic review (synthesis, counted as a synthesis)
Population: Patients in 17 studies comparing an element of the history or physical examination with a reference standard of ankle-brachial index, duplex sonography or angiogram, analysed separately for asymptomatic and symptomatic spectra.
Summary: Khan Rational Clinical Examination 2006 (JAMA — 17 studies vs ankle-brachial index, duplex or angiography): in asymptomatic patients the most useful findings were claudication (LR 3.30), femoral bruit (LR 4.80) and any pulse abnormality (LR 3.10), and no finding's absence lowered the likelihood of any PAD; in symptomatic patients, cool skin (LR 5.90), at least one bruit (LR 5.60) and any palpable pulse abnormality (LR 4.70), with absence of all bruits (LR 0.39) or of any pulse abnormality (LR 0.38) reducing likelihood; combinations added nothing beyond individual findings
Result: For asymptomatic patients: claudication LR 3.30 (95% CI 2.30–4.80), femoral bruit LR 4.80 (2.40–9.50), any pulse abnormality LR 3.10 (1.40–6.60); no clinical feature's absence lowered the likelihood of any degree of PAD, though absence of claudication or normal pulses decreased the likelihood of moderate-to-severe disease. For symptomatic patients: cool skin LR 5.90 (4.10–8.60), at least 1 bruit LR 5.60 (4.70–6.70), any palpable pulse abnormality LR 4.70 (2.20–9.90); absence of any bruits LR 0.39 (0.34–0.45) and of any pulse abnormality LR 0.38 (0.23–0.64) reduced likelihood. Combinations did not increase likelihood beyond individual findings. All likelihood ratios are relative measures and print labelled as such.
Watch out: The asymptomatic and symptomatic pools are printed apart in the record and kept apart here — the same sign carries different weight in the two spectra, and merging them would fabricate a single 'examination LR' that no study measured. The review also notes a Doppler-auscultation scoring system performed better; that is a device limb, counted nowhere on this shelf.
Source: Khan NA et al. Does the clinical examination predict lower extremity peripheral arterial disease?. JAMA. 2006. PMID: 16449619. Registry ID: none in the record. MeSH: Ankle/blood supply · Atherosclerosis/diagnosis · Auscultation · Blood Pressure Determination/methods* · Brachial Artery/physiology* · Diagnosis, Differential · Humans · Intermittent Claudication/diagnosis*,etiology · Lower Extremity · Oscillometry · Peripheral Vascular Diseases/diagnosis*,physiopathology · Physical Examination/methods* · Point-of-Care Systems · Pulse · Ultrasonography, Doppler
Card 2 — Cournot screening study 2007 (Journal of Vascular Surgery — 2,736 asymptomatic men and women aged 20–90, standardised examination vs carotid/femoral ultrasound and ABI): a femoral bruit carried LR+ 2.90 (1.63–5.16) for ABI <0.9 and 3.23 (2.22–4.71) for femoral plaque, independent of risk factors; absence of both pedal pulses carried LR+ 3.57 (1.93–6.60) for ABI <0.9 — and a carotid bruit gave no information about carotid stenosis, plaque or intima-media thickness
Study: Prospective screening accuracy study (primary report)
Population: 2,736 asymptomatic, apparently healthy men and women aged 20–90 with no personal history of cardiovascular disease and no neurologic, coronary or lower-limb symptoms, given a standardised physical examination plus carotid and femoral ultrasonography and ABI.
Summary: Cournot screening study 2007 (Journal of Vascular Surgery — 2,736 asymptomatic men and women aged 20–90, standardised examination vs carotid/femoral ultrasound and ABI): a femoral bruit carried LR+ 2.90 (1.63–5.16) for ABI <0.9 and 3.23 (2.22–4.71) for femoral plaque, independent of risk factors; absence of both pedal pulses carried LR+ 3.57 (1.93–6.60) for ABI <0.9 — and a carotid bruit gave no information about carotid stenosis, plaque or intima-media thickness
Result: The presence of a femoral bruit provided information on both ABI <0.9 (LR+ 2.90, 95% CI 1.63–5.16) and femoral plaque (LR+ 3.23, 2.22–4.71), independent of cardiovascular risk factors. Absence of both pedal pulses also provided information beyond risk factors on ABI <0.9 (LR+ 3.57, 1.93–6.60). The presence of a carotid bruit did not affect the likelihood of carotid stenosis, plaque or intima-media thickness above the median.
Watch out: The carotid limb is a negative limb for neck auscultation and prints as such: it bounds, but does not reopen, the homed carotid-bruit-for-stenosis question (pack #7874, a symptomatic/surgical spectrum). An asymptomatic screening population — its LRs describe subclinical disease, not the symptomatic patient in clinic.
Source: Cournot M et al. Accuracy of the screening physical examination to identify subclinical atherosclerosis and peripheral arterial disease in asymptomatic subjects. Journal of vascular surgery. 2007. PMID: 18154997. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Ankle/blood supply · Atherosclerosis/diagnosis*,diagnostic imaging,physiopathology · Auscultation · Blood Pressure · Brachial Artery/physiopathology · Carotid Stenosis/diagnosis*,diagnostic imaging,physiopathology · Female · Femoral Artery*/diagnostic imaging,physiopathology · Humans · Likelihood Functions · Male · Mass Screening/methods* · Middle Aged · Odds Ratio · Palpation · Peripheral Vascular Diseases/diagnosis*,diagnostic imaging,physiopathology · Physical Examination* · Predictive Value of Tests · Prospective Studies · Pulse · Reproducibility of Results · Research Design · Sensitivity and Specificity · Ultrasonography
Card 3 — Herráiz-Adillo primary-care accuracy study 2018 (International Journal of Clinical Practice — 158 consecutive primary-care subjects, 315 legs; PAD in 38 legs (12.1%) by Doppler ABI): nurse palpation with 'absent dorsalis pedis or posterior tibial' as positive gave sensitivity 86.8%, specificity 82.7%, LR+ 5.01 and LR− 0.16; physician–nurse weighted κ was 0.649; femoral bruit had diagnostic OR 3.8 and calf circumference <34.55 cm OR 3.2 (relative measures)
Study: Diagnostic accuracy study (primary report)
Population: 158 consecutive primary-care subjects (inclusion: diabetes, dyslipidaemia, hypertension, current/former smoking, or age ≥65), 315 legs; two experienced professionals (physician and nurse) performed pedal pulse palpation, femoral bruit auscultation and calf circumference against Doppler ABI (positive cut-off ABI ≤0.9 or ≥1.4); PAD was confirmed in 38 legs (12.1%).
Summary: Herráiz-Adillo primary-care accuracy study 2018 (International Journal of Clinical Practice — 158 consecutive primary-care subjects, 315 legs; PAD in 38 legs (12.1%) by Doppler ABI): nurse palpation with 'absent dorsalis pedis or posterior tibial' as positive gave sensitivity 86.8%, specificity 82.7%, LR+ 5.01 and LR− 0.16; physician–nurse weighted κ was 0.649; femoral bruit had diagnostic OR 3.8 and calf circumference <34.55 cm OR 3.2 (relative measures)
Result: For nurse evaluation with absent dorsalis pedis or posterior tibial pulse as positive: sensitivity 86.8 (95% CI 74.8–98.9), specificity 82.7 (78.0–87.3), LR+ 5.01 (3.77–6.67), LR− 0.16 (0.07–0.36) and diagnostic odds ratio 31.5 (11.7–84.8). Absent dorsalis pedis was found in 37 legs (11.7%) and absent posterior tibial in 67 (21.3%). Physician–nurse weighted kappa was 0.649 (0.599–0.699). Femoral bruit had a diagnostic OR of 3.8 (1.1–13.1) and calf circumference <34.55 cm an OR of 3.2 (1.6–6.4) — relative measures. Age, diabetes and calcification (ABI ≥1.4) influenced false-negative palpation rates.
Watch out: The shelf's best primary — and a single rural primary-care population with 38 PAD legs; its LR− of 0.16 is the strongest rule-out figure on the shelf and rests on those 38 legs. The counting unit is legs (315), not patients (158), and prints as such.
Source: Herráiz-Adillo Á et al. Physical examination to screen for peripheral artery disease in a defined Primary Care population: A diagnostic accuracy study. International journal of clinical practice. 2018. PMID: 30222240. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Auscultation · False Negative Reactions · Female · Humans · Leg/pathology* · Male · Middle Aged · Observer Variation · Palpation · Peripheral Arterial Disease/diagnosis* · Physical Examination* · Primary Health Care/methods* · Sensitivity and Specificity
Card 4 — Forsythe / IWGDF systematic review 2020 (Diabetes/Metabolism Research and Reviews — 15 studies, 1,563 patients, >80% diabetic in each, bedside tests vs reference imaging in diabetes/foot-ulcer spectra): the clinical-examination limb — examination including foot-pulse palpation cannot reliably exclude PAD (negative LR 0.75, one study)
Study: Systematic review (synthesis, counted as a synthesis) — shared report, printed as shared: only its clinical-examination limb is carded here; its ABI, toe-index, oximetry and waveform limbs are device tests counted nowhere on this shelf
Population: People with diabetes mellitus and foot ulceration spectra in 15 eligible studies comprising 1,563 patients (>80% diabetic in each study), evaluating bedside index tests against reference imaging (magnetic resonance, CT or digital subtraction angiography, or colour duplex ultrasound).
Summary: Forsythe / IWGDF systematic review 2020 (Diabetes/Metabolism Research and Reviews — 15 studies, 1,563 patients, >80% diabetic in each, bedside tests vs reference imaging in diabetes/foot-ulcer spectra): the clinical-examination limb — examination including foot-pulse palpation cannot reliably exclude PAD (negative LR 0.75, one study)
Result: The review's primary endpoints were positive and negative likelihood ratios across bedside tests. For the clinical-examination limb — beside clinical examination including palpation of foot pulses — the review found it cannot reliably exclude PAD (negative likelihood ratio 0.75), as evaluated in one study. (The review's device limbs are reported on their own cards nowhere here: ABI <0.9 PLR 6.5 with NLR 0.31 for ABI 0.9–1.3; toe-brachial index and waveform limbs are device tests.) The authors conclude the quality of data is generally poor and there is insufficient evidence to recommend one bedside test over another.
Watch out: The examination limb rests on one study inside a device-test review, in the spectrum (diabetes with foot ulceration) where calcified, incompressible arteries most distort every bedside test — it bounds the examination's rule-out power in diabetes; it does not describe non-diabetic spectra.
Source: Forsythe RO et al. Effectiveness of bedside investigations to diagnose peripheral artery disease among people with diabetes mellitus: A systematic review. Diabetes/metabolism research and reviews. 2020. PMID: 32176448. Registry ID: none in the record. MeSH: Diabetes Mellitus/physiopathology* · Diabetic Foot/complications*,epidemiology · Humans · Peripheral Arterial Disease/diagnosis*,etiology · Practice Guidelines as Topic/standards* · Practice Patterns, Physicians'/standards* · Prognosis
Card 5 — Synthesis — moderate and asymmetric across 4 reports (1 RCE pool + 2 primaries + 1 shared-review limb): abnormal pulses or a femoral bruit raise PAD probability (LR ≈3–5), a fully normal pulse examination lowers it (LR ≈0.38–0.39 in the RCE pool; LR− 0.16 for absent-pulse palpation in one primary-care study) — but in diabetic foot spectra the examination cannot exclude PAD (negative LR 0.75, one study)
Study: Synthesis
Population: Composition: Khan 2006 RCE (17 studies, asymptomatic and symptomatic spectra printed apart) + Cournot 2007 (2,736 asymptomatic screening subjects) + Herráiz-Adillo 2018 (158 subjects, 315 legs, 38 PAD legs) + Forsythe 2020 IWGDF review (15 studies, 1,563 patients; examination limb only, resting on one study). Refused: nothing was refused on this row. Counted nowhere: Khan's Doppler-scoring limb, Forsythe's device limbs (ABI, toe index, oximetry, waveforms), and Cournot's carotid limb beyond its printed negative bound on pack #7874's question. Cross-point in prose only: pack #8488 (irregular-pulse detection of atrial fibrillation) is a different question that shares only the words 'pulse palpation'.
Summary: Synthesis — moderate and asymmetric across 4 reports (1 RCE pool + 2 primaries + 1 shared-review limb): abnormal pulses or a femoral bruit raise PAD probability (LR ≈3–5), a fully normal pulse examination lowers it (LR ≈0.38–0.39 in the RCE pool; LR− 0.16 for absent-pulse palpation in one primary-care study) — but in diabetic foot spectra the examination cannot exclude PAD (negative LR 0.75, one study)
Result: The examination's asymmetry is the finding. Raising probability: femoral bruit LR 4.80 (asymptomatic, RCE) and 2.90 for ABI <0.9 (screening primary); any pulse abnormality LR 3.10–4.70; cool skin 5.90 and ≥1 bruit 5.60 in symptomatic patients; absent-pulse palpation LR+ 5.01 in primary care. Lowering it: absence of all bruits LR 0.39 and of any pulse abnormality LR 0.38 (RCE, symptomatic), and LR− 0.16 for the absent-pulse definition in the primary-care study — against no useful negative finding for any PAD in asymptomatic patients (RCE) and an examination negative LR of 0.75 in diabetic foot spectra (IWGDF limb, one study). Combinations added nothing beyond individual findings (RCE). Every likelihood ratio is a relative measure and prints labelled as such.
Watch out: The two rule-out figures a reader will want to quote — LR− 0.16 and NLR 0.75 — come from opposite spectra (risk-factor primary care vs diabetic foot ulceration) and differ by design, not by error; quoting either without its spectrum misrepresents the base.
Source: Synthesis of the reports carded above; no additional source.