SourceMed · Shelf #8875 in the ask interface

Ankle syndesmosis tests — 4 reports: palpation tenderness sensitive (92%) but no test rules injury in or out alone, and the one independent examiner study found every test's sensitivity between 13.9% and 55.6%

Shelf #8875 · Bones & joints

PREDICTIVE PERFORMANCE — cluster-only: palpation tenderness is sensitive (92% in both the primary study and the meta-analysis) but the squeeze and external-rotation tests reach only 78–88% specificity, no test rules syndesmotic injury in or out alone, and the one independent examiner study found every clinical test's sensitivity between 13.9% and 55.6%

Stamped: 2026-11-28.

Evidence published: 2013–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with acute ankle sprain and suspected syndesmotic (high ankle) injury, how accurately do the clinical tests — squeeze test, external-rotation stress, syndesmosis palpation, Cotton test, dorsiflexion lunge/compression — identify syndesmotic ligament injury against MRI or arthroscopy?

Balance of the evidence

Four reports; two (Sman 2013 review and Sman 2015 primary) are one Australian programme, printed as such. The meta-analysis's palpation pool (sensitivity 92%) and the independent Großterlinden study's proximal-fibula palpation result (best inter-rater agreement, κ 0.65, but lowest sensitivity, 8% — a different palpation site) point in opposite directions and both print. Reference standards vary (MRI vs arthroscopy). The lateral ankle ligament tests are homed at pack #7969 and are not reopened.

MeSH: Ankle Injuries/diagnosis*,physiopathology · Ankle Joint/physiopathology · Athletic Injuries/diagnosis* · Humans · Observer Variation · Physical Examination/methods · Range of Motion, Articular/physiology · Reproducibility of Results · Sports Medicine/methods · Adolescent · Adult · Ankle Injuries/diagnosis* · Athletic Injuries/diagnosis* · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Physical Examination/methods · Sensitivity and Specificity · Young Adult · Adolescent · Adult · Ankle Injuries/diagnosis* · Female · Humans · Ligaments, Articular/diagnostic imaging,injuries* · Magnetic Resonance Imaging* · Male · Middle Aged · Palpation* · Physical Examination · Reproducibility of Results · Sprains and Strains/diagnosis* · Young Adult · Adolescent · Adult · Aged · Ankle Injuries/diagnosis* · Ankle Joint/diagnostic imaging · Arthroscopy/methods · Female · Humans · Ligaments, Articular/diagnostic imaging*,injuries* · Magnetic Resonance Imaging/methods · Male · Middle Aged · Physical Examination/methods · Range of Motion, Articular · Rotation · Sensitivity and Specificity · Ultrasonography/methods · Young Adult

Cards (5)

Card 1 — Sman systematic review 2013 (BJSM — only 3 eligible studies, raw data obtained from authors; 8 tests): the two accuracy studies conflicted on the squeeze test, other tests' likelihood ratios ranged only LR+ 1.50 to LR− 1.50 as printed, and clinicians cannot rely on a single test — programme-linked to the 2015 primary below

Study: Systematic review

Population: Studies of participants with suspected ankle syndesmosis injury without fracture, comparing clinical tests with a reference standard or assessing reliability; the database search yielded 114 full-text articles assessed, 3 studies included. No pooled patient N is printed in the record.

Summary: Sman systematic review 2013 (BJSM — only 3 eligible studies, raw data obtained from authors; 8 tests): the two accuracy studies conflicted on the squeeze test, other tests' likelihood ratios ranged only LR+ 1.50 to LR− 1.50 as printed, and clinicians cannot rely on a single test — programme-linked to the 2015 primary below

Result: Eight clinical diagnostic tests were investigated: palpation of the tibiofibular ligaments, external rotation stress test, squeeze, Cotton, fibula translation, dorsiflexion range of motion and anterior drawer tests. Two studies investigated diagnostic accuracy and both investigated the squeeze test, with conflicting results. Likelihood ratios ranging from LR+ 1.50 to LR− 1.50 were found for other tests. High intra-rater reliability was found for the squeeze, Cotton, dorsiflexion ROM and external rotation tests (83–100% close agreement); inter-rater reliability was good for external rotation (ICC >0.70) and fair-to-poor for other tests. The authors conclude clinicians cannot rely on a single test to identify ankle syndesmosis injury with certainty.

Watch out: A three-study evidence base is a census of absence as much as of accuracy: most named syndesmosis tests had never been accuracy-tested at all when this review searched (to August 2012).

Source: Sman AD et al. Diagnostic accuracy of clinical tests for diagnosis of ankle syndesmosis injury: a systematic review. British journal of sports medicine. 2013. PMID: 23222193. Registry ID: none in the record. MeSH: Ankle Injuries/diagnosis*,physiopathology · Ankle Joint/physiopathology · Athletic Injuries/diagnosis* · Humans · Observer Variation · Physical Examination/methods · Range of Motion, Articular/physiology · Reproducibility of Results · Sports Medicine/methods

Card 2 — Sman diagnostic-accuracy study 2015 (BJSM — 87 participants with ankle sprain within 2 weeks, MRI reference): syndesmosis ligament tenderness sensitivity 92% (LR− 0.28 (0.09–0.89)); dorsiflexion–external-rotation stress sensitivity 71% (LR− 0.46 (0.27–0.79)); squeeze test specificity 88% (LR+ 2.15 (0.86–5.39) — the interval crosses 1); inability to perform a single-leg hop was the most sensitive presentation feature (89%) and pain out of proportion the most specific (79%, LR+ 3.05) — programme-linked to the review above

Study: Cross-sectional diagnostic accuracy study (primary report)

Population: Eighty-seven participants (78% male) with an ankle sprain injury presenting to nine clinics in two Australian cities within 2 weeks of injury; clinical presentation and four clinical tests compared with MRI read by a blinded radiologist.

Summary: Sman diagnostic-accuracy study 2015 (BJSM — 87 participants with ankle sprain within 2 weeks, MRI reference): syndesmosis ligament tenderness sensitivity 92% (LR− 0.28 (0.09–0.89)); dorsiflexion–external-rotation stress sensitivity 71% (LR− 0.46 (0.27–0.79)); squeeze test specificity 88% (LR+ 2.15 (0.86–5.39) — the interval crosses 1); inability to perform a single-leg hop was the most sensitive presentation feature (89%) and pain out of proportion the most specific (79%, LR+ 3.05) — programme-linked to the review above

Result: Of the clinical tests, the squeeze test had the highest specificity (88%) with a positive LR of 2.15 (95% CI 0.86 to 5.39). Syndesmosis ligament tenderness (92%) and the dorsiflexion-external rotation stress test (71%) had the highest sensitivity values and negative LRs of 0.28 (95% CI 0.09 to 0.89) and 0.46 (95% CI 0.27 to 0.79), respectively. The clinical presentation of an inability to perform a single leg hop had the highest sensitivity (89%) with a negative LR of 0.37 (0.13 to 1.03); specificity was highest for pain out of proportion to the apparent injury (79%) with a positive LR of 3.05 (1.68 to 5.55). The authors recommend combining sensitive and specific signs, symptoms and tests.

Watch out: The squeeze test's LR+ interval crosses 1 (0.86–5.39), so even the 'specific' limb is statistically fragile at n = 87; the hop and pain-out-of-proportion items are presentation features, not examination tests, and print as such.

Source: Sman AD et al. Diagnostic accuracy of clinical tests for ankle syndesmosis injury. British journal of sports medicine. 2015. PMID: 24255766. Registry ID: none in the record. MeSH: Adolescent · Adult · Ankle Injuries/diagnosis* · Athletic Injuries/diagnosis* · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Physical Examination/methods · Sensitivity and Specificity · Young Adult

Card 3 — Großterlinden clinical-examination study 2016 (KSSTA — 96 patients with acute ankle sprain, two independent examiners vs MRI): MRI found AITFL rupture in 14 (15%); every clinical test's sensitivity was low (13.9–55.6%); proximal-fibula palpation had the best inter-rater agreement (κ 0.65) but the lowest sensitivity (8%); the authors conclude clinical examination was insufficient — the deflationary independent limb, at headline weight

Study: Diagnostic accuracy study (primary report)

Population: One hundred patients with acute ankle sprain without fracture were enrolled; 96 participants (57% male) met the inclusion criteria. Clinical assessment by two independent examiners (local findings, ligament palpation, squeeze, external rotation, drawer, Cotton and crossed-leg tests) was compared with MRI read by two blinded radiologists; MRI detected a ruptured anterior inferior tibiofibular ligament in 14 patients (15%; 9 partial, 5 complete tears).

Summary: Großterlinden clinical-examination study 2016 (KSSTA — 96 patients with acute ankle sprain, two independent examiners vs MRI): MRI found AITFL rupture in 14 (15%); every clinical test's sensitivity was low (13.9–55.6%); proximal-fibula palpation had the best inter-rater agreement (κ 0.65) but the lowest sensitivity (8%); the authors conclude clinical examination was insufficient — the deflationary independent limb, at headline weight

Result: Evidence of pain at rest was found to predict syndesmotic injuries most accurately (p = 0.039). The palpation test over the proximal fibula produced the highest inter-rater correlation (κ = 0.65), but the lowest sensitivity for syndesmotic injuries of 8%. All other clinical tests demonstrated moderate to fair inter-rater reliabilities (κ = 0.37–0.52). Low sensitivity values were found with all clinical tests (13.9–55.6%). The authors conclude clinical examination was insufficient to detect syndesmotic injuries in acute ankle sprains and recommend MRI in patients with ongoing pain at rest.

Watch out: Only 14 MRI-positive cases drive every sensitivity figure, so each is imprecise; and its palpation site (proximal fibula) differs from the syndesmosis-ligament tenderness that scored 92% in the Sman study — the contradiction is partly anatomical, and prints as such rather than being averaged away.

Source: Großterlinden LG et al. Isolated syndesmotic injuries in acute ankle sprains: diagnostic significance of clinical examination and MRI. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2016. PMID: 25895834. Registry ID: none in the record. MeSH: Adolescent · Adult · Ankle Injuries/diagnosis* · Female · Humans · Ligaments, Articular/diagnostic imaging,injuries* · Magnetic Resonance Imaging* · Male · Middle Aged · Palpation* · Physical Examination · Reproducibility of Results · Sprains and Strains/diagnosis* · Young Adult

Card 4 — Netterström-Wedin systematic review with meta-analysis 2021 (Physical Therapy in Sport — 6 studies, 512 participants, 13 tests): no test had both high sensitivity and specificity; highest sensitivities palpation 92% (79–98) and dorsiflexion lunge 75% (64–84); highest specificities squeeze 85% (81–89) and external rotation 78% (73–82); clustering sensitive then specific tests recommended, with imaging/arthroscopy still required to grade stability

Study: Systematic review with meta-analysis

Population: Six studies (512 participants; 29% median prevalence) comparing clinical examination to arthroscopy, MRI or ultrasound; meta-analysis limited to studies fulfilling all QUADAS-2 criteria, using random-effects modelling.

Summary: Netterström-Wedin systematic review with meta-analysis 2021 (Physical Therapy in Sport — 6 studies, 512 participants, 13 tests): no test had both high sensitivity and specificity; highest sensitivities palpation 92% (79–98) and dorsiflexion lunge 75% (64–84); highest specificities squeeze 85% (81–89) and external rotation 78% (73–82); clustering sensitive then specific tests recommended, with imaging/arthroscopy still required to grade stability

Result: No individual test was associated with both high sensitivity and high specificity. Tests with the highest sensitivity were palpation (SN 92% (95% CI 79–98)) and dorsiflexion lunge (SN 75% (95% CI 64–84); 2 studies). Tests with the highest specificity were the squeeze test (SP 85% (95% CI 81–89); 4 studies) and external rotation (SP 78% (95% CI 73–82); 4 studies). The authors conclude clinical examination should involve initial clustering of tests with high sensitivity, followed by a test with high specificity, but these tests cannot definitively stratify injuries into stable vs unstable.

Watch out: The palpation pool leans on the Sman programme's data, so the meta-analysis and the 2015 primary are not independent confirmations of the 92% figure; the independent examiner study on this shelf contradicts it at a different palpation site.

Source: Netterström-Wedin F et al. Diagnostic accuracy of clinical tests assessing ligamentous injury of the ankle syndesmosis: A systematic review with meta-analysis. Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine. 2021. PMID: 33774464. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Ankle Injuries/diagnosis* · Ankle Joint/diagnostic imaging · Arthroscopy/methods · Female · Humans · Ligaments, Articular/diagnostic imaging*,injuries* · Magnetic Resonance Imaging/methods · Male · Middle Aged · Physical Examination/methods · Range of Motion, Articular · Rotation · Sensitivity and Specificity · Ultrasonography/methods · Young Adult

Card 5 — Synthesis — PREDICTIVE PERFORMANCE, cluster-only: 4 reports (one programme pair, one independent primary, one meta-analysis); palpation tenderness is the sensitive limb, squeeze/external rotation the specific limb, and no single test rules syndesmotic injury in or out

Study: Synthesis

Population: Composition: Sman 2013 review (3 studies) + Sman 2015 primary (87 participants) — one Australian programme, counted as such + Großterlinden 2016 independent primary (96 patients, 14 MRI-positive) + Netterström-Wedin 2021 meta-analysis (6 studies, 512 participants). No report was refused on this row.

Summary: Synthesis — PREDICTIVE PERFORMANCE, cluster-only: 4 reports (one programme pair, one independent primary, one meta-analysis); palpation tenderness is the sensitive limb, squeeze/external rotation the specific limb, and no single test rules syndesmotic injury in or out

Result: The honest shape is asymmetry plus contradiction: sensitive tests are not specific, specific tests are not sensitive, the squeeze LR+ interval crosses 1 in the primary, and the independent study found all sensitivities at 13.9–55.6%. Clustering (sensitive tests first, then a specific test) is the sources' own recommendation; grading stability still needs imaging or arthroscopy. Cross-point in prose only: lateral ankle ligament tests, pack #7969.

Watch out: Smallest load-bearing limb: 14 MRI-confirmed cases in the independent study — its low sensitivities are imprecise, though directionally concordant with the reviews' refusal to endorse any single test.

Source: Synthesis of the reports carded above; no additional source.