De Quervain tenosynovitis tests — 3 reports with three different reference standards: the WHAT test near-perfectly sensitive (0.99) but unspecific (0.29), the radial synergy test specific (99% vs Eichhoff 74%), and the DQST's perfect discrimination from small pre-diagnosed samples
Shelf #8876 · Bones & joints
PREDICTIVE PERFORMANCE — complementary profiles, no complete test: the WHAT test is near-perfectly sensitive (0.99) but unspecific (0.29), the radial synergy test trades a little sensitivity (91% vs Eichhoff 97%) for near-perfect specificity (99% vs 74%), and the DQST's perfect discrimination (sensitivity and specificity both 1.00) comes from small, already-diagnosed samples — three single-centre studies with three different reference standards
Stamped: 2026-11-28.
Evidence published: 2008–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with radial-sided wrist pain, how accurately do the bedside tests for de Quervain tenosynovitis — the Finkelstein/Eichhoff manoeuvre, the wrist hyperflexion and abduction of the thumb (WHAT) test, the radial synergy test, and the multi-item de Quervain's screening tool (DQST) — identify the condition against ultrasound, injection response or clinical reference standards?
Balance of the evidence
Three reports, three reference standards (clinical, ultrasound, injection response), never pooled. The test-description paper Dawson & Mudgal 2010 (PMID 20709467) prints a 321-character abstract with no figures and is named in prose only: it establishes that the commonly performed 'Finkelstein' is usually Eichhoff's manoeuvre — a naming confusion this pack's face carries. The eponymous Finkelstein test itself has no direct accuracy study in this composition, and Eichhoff's own accuracy pair is never printed in any fetched record (it appears only as a comparator direction in the WHAT study and as paired figures in the radial-synergy study). Wrist examination ground already homed — carpal tunnel (#7859) and scaphoid (#7864) — is not reopened.
MeSH: Adult · De Quervain Disease/complications,diagnosis*,therapy · Female · Humans · Male · Middle Aged · Observer Variation · Pain Measurement · Physical Examination · Pilot Projects · Population Surveillance/methods* · Reproducibility of Results · Sensitivity and Specificity · Adolescent · Adult · Aged · Aged, 80 and over · De Quervain Disease/diagnosis* · Female · Humans · Male · Middle Aged · Physical Examination · Prospective Studies · Range of Motion, Articular · Sensitivity and Specificity · Young Adult · Humans · Tenosynovitis*/diagnosis · De Quervain Disease*/diagnosis · Prospective Studies · Retrospective Studies · Pain/diagnosis · Lidocaine
Cards (4)
Card 1 — Batteson DQST validity study 2008 (Musculoskeletal Care — typed Controlled Clinical Trial; 59 people with de Quervain's, 18 with carpal tunnel syndrome, 16 with CMC-joint osteoarthritis): the 7-item screening tool's median score in de Quervain's was 5/7; inter-rater reliability ICC 0.85, test–retest ICC 0.64; sensitivity and specificity both 1.00 for discriminating de Quervain's from CTS and CMC osteoarthritis — perfect figures from a 93-person, already-diagnosed spectrum, printed with that caveat at headline weight
Study: Validity and reliability study (primary report; typed Controlled Clinical Trial)
Population: Three convenience samples recruited in an acute-care outpatient hand unit: 59 people with de Quervain's disease, 18 with carpal tunnel syndrome and 16 with osteoarthritis of the carpometacarpal joint; the DQST's seven items were generated from a literature review and content-validated by seven expert doctors.
Summary: Batteson DQST validity study 2008 (Musculoskeletal Care — typed Controlled Clinical Trial; 59 people with de Quervain's, 18 with carpal tunnel syndrome, 16 with CMC-joint osteoarthritis): the 7-item screening tool's median score in de Quervain's was 5/7; inter-rater reliability ICC 0.85, test–retest ICC 0.64; sensitivity and specificity both 1.00 for discriminating de Quervain's from CTS and CMC osteoarthritis — perfect figures from a 93-person, already-diagnosed spectrum, printed with that caveat at headline weight
Result: The median DQST score was 5 (IQR 4–6) out of a possible seven diagnostic criteria. Inter-rater reliability was excellent (ICC = 0.85; 95% CI 0.75, 0.91). Test–retest reliability was good (ICC = 0.64; 95% CI 0.20, 0.87). Sensitivity and specificity testing (Se = 1.00; Sp = 1.00) demonstrated that the DQST discriminated between people with de Quervain's disease, CTS or OA of the CMC joint. The authors recommend further research with a larger sample to examine retest reliability.
Watch out: Perfect discrimination between three already-diagnosed groups is the easiest discrimination task in diagnostics; it says little about performance in undifferentiated radial wrist pain, where the tool would actually be used. The test–retest interval's confidence interval is wide (0.20–0.87).
Source: Batteson R et al. The de Quervain's screening tool: validity and reliability of a measure to support clinical diagnosis and management. Musculoskeletal care. 2008. PMID: 18618462. Registry ID: none in the record. MeSH: Adult · De Quervain Disease/complications,diagnosis*,therapy · Female · Humans · Male · Middle Aged · Observer Variation · Pain Measurement · Physical Examination · Pilot Projects · Population Surveillance/methods* · Reproducibility of Results · Sensitivity and Specificity
Card 2 — Goubau WHAT-test study 2014 (J Hand Surg Eur — prospective, 100 patients with spontaneous radial styloid pain, ultrasound reference): the WHAT test had sensitivity 0.99, specificity 0.29, PPV 0.95, NPV 0.67, each better than the Eichhoff test in the same cohort — the record prints the WHAT figures and the direction of the comparison, not Eichhoff's own pair, and none is invented here
Study: Prospective diagnostic accuracy study (primary report)
Population: A prospective cohort over three years of 100 patients (88 women, 12 men) presenting with spontaneous pain over the radial side of the styloid of the radius (de Quervain tendinopathy); clinical findings using the Eichhoff test and the WHAT test were compared with ultrasound results.
Summary: Goubau WHAT-test study 2014 (J Hand Surg Eur — prospective, 100 patients with spontaneous radial styloid pain, ultrasound reference): the WHAT test had sensitivity 0.99, specificity 0.29, PPV 0.95, NPV 0.67, each better than the Eichhoff test in the same cohort — the record prints the WHAT figures and the direction of the comparison, not Eichhoff's own pair, and none is invented here
Result: The wrist hyperflexion and abduction of the thumb test revealed greater sensitivity (0.99) and an improved specificity (0.29) together with a slightly better positive predictive value (0.95) and an improved negative predictive value (0.67) than the Eichhoff test. The record also states the WHAT test is very valuable in diagnosing dynamic instability after successful decompression of the first extensor compartment. The authors support the WHAT test as a more precise tool for diagnosis of de Quervain's disease than the Eichhoff test. The record's introduction carries the naming correction: the Eichhoff test is often wrongly named as the Finkelstein test.
Watch out: A sensitivity-0.99 / specificity-0.29 profile is a rule-out-shaped test in a high-prevalence clinic spectrum (PPV 0.95 reflects that prevalence); 'more specific than Eichhoff' at 0.29 still means most positive results in a low-prevalence setting would be false. Eichhoff's own pair is not in the record.
Source: Goubau JF et al. The wrist hyperflexion and abduction of the thumb (WHAT) test: a more specific and sensitive test to diagnose de Quervain tenosynovitis than the Eichhoff's Test. The Journal of hand surgery, European volume. 2014. PMID: 23340762. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · De Quervain Disease/diagnosis* · Female · Humans · Male · Middle Aged · Physical Examination · Prospective Studies · Range of Motion, Articular · Sensitivity and Specificity · Young Adult
Card 3 — Lee radial-synergy study 2023 (Hand — 222 patients / 254 extremities diagnosed with de Quervain's, reference ≥90% pain relief after lidocaine/corticosteroid injection, and 48 pain-free volunteers / 93 extremities): radial synergy test sensitivity 91% vs Eichhoff 97%, specificity 99% vs Eichhoff 74% (relative risks as published) — the reference standard is injection response, not imaging or surgery, and prints as such
Study: Diagnostic accuracy study (primary report; retrospective sensitivity limb, prospective specificity limb)
Population: Sensitivity was evaluated by retrospective chart review of patients diagnosed with de Quervain's from 2013 to 2018 with documented radial synergy and Eichhoff tests and ≥90% pain relief after lidocaine/corticosteroid injection (222 patients, 254 extremities); specificity in a prospective cohort of 48 volunteers without pre-existing wrist pain (93 extremities), a visual analogue score >0 counting as positive. Electromyography in three authors confirmed first-dorsal-compartment recruitment during the manoeuvre.
Summary: Lee radial-synergy study 2023 (Hand — 222 patients / 254 extremities diagnosed with de Quervain's, reference ≥90% pain relief after lidocaine/corticosteroid injection, and 48 pain-free volunteers / 93 extremities): radial synergy test sensitivity 91% vs Eichhoff 97%, specificity 99% vs Eichhoff 74% (relative risks as published) — the reference standard is injection response, not imaging or surgery, and prints as such
Result: Sensitivity of the radial synergy test was inferior to Eichhoff's test (91% vs 97%, relative risk [RR] = 0.93 [95% CI = 0.89–0.97], P < .01, in the order radial synergy vs Eichhoff as the record's comparison states). Specificity of the radial synergy test was superior to Eichhoff's test (99% vs 74%, RR = 1.33 [95% CI = 1.18–1.51], P < .001). The authors describe the radial synergy test as an adjunct for diagnostic evaluations with its high specificity (level of evidence II).
Watch out: Cases and controls come from different designs and spectra (injection responders vs pain-free volunteers), which inflates both sensitivity and specificity relative to a single undifferentiated cohort; injection response is a treatment-response reference standard, not an anatomical one.
Source: Lee C et al. The Radial Synergy Test: An Aid to Diagnose de Quervain's Tenosynovitis. Hand (New York, N.Y.). 2023. PMID: 34969308. Registry ID: none in the record. MeSH: Humans · Tenosynovitis*/diagnosis · De Quervain Disease*/diagnosis · Prospective Studies · Retrospective Studies · Pain/diagnosis · Lidocaine
Card 4 — Synthesis — PREDICTIVE PERFORMANCE, complementary profiles: 3 reports, three reference standards; WHAT rules out, radial synergy rules in, DQST discriminates diagnosed groups perfectly in a small spectrum — and the eponymous Finkelstein test is never directly accuracy-tested in this base
Study: Synthesis
Population: Composition: Batteson 2008 (93 people in three diagnosed groups) + Goubau 2014 (100 clinic patients, ultrasound reference) + Lee 2023 (222 patients / 254 extremities plus 48 volunteers / 93 extremities, injection-response reference). Named in prose only, never carded: Dawson & Mudgal 2010 (PMID 20709467), the staged test-description paper establishing that the commonly performed 'Finkelstein' is usually Eichhoff's manoeuvre; its abstract prints no figures.
Summary: Synthesis — PREDICTIVE PERFORMANCE, complementary profiles: 3 reports, three reference standards; WHAT rules out, radial synergy rules in, DQST discriminates diagnosed groups perfectly in a small spectrum — and the eponymous Finkelstein test is never directly accuracy-tested in this base
Result: No test on this shelf is both sensitive and specific in an undifferentiated population: WHAT 0.99/0.29, radial synergy 91%/99% across split spectra, DQST 1.00/1.00 across diagnosed groups. The naming confusion is part of the evidence: studies of 'Finkelstein' largely test Eichhoff's manoeuvre, so the eponym's own accuracy is unknown. This is the second-weakest row of its slate part, and the stamp carries no more than the profiles printed.
Watch out: A developer ruling may be wanted on whether a 3-report, 3-reference-standard composition belongs at full shelf weight; it is built as rowed, with every caveat on the face.
Source: Synthesis of the reports carded above; no additional source.