SourceMed · Shelf #8880 in the ask interface
Tuning-fork tests (Rinne and Weber) — 4 reports: Rinne sensitivity for conductive loss spans 16–91% across 17 studies depending on fork frequency and threshold, combined fork protocols classify loss type at ≈77% / 85% in adults, and in children with middle-ear effusion both classic tests perform poorly
Shelf #8880 · Eyes, skin, nose & allergy
PREDICTIVE PERFORMANCE — wide and threshold-dependent: across 17 studies the Rinne test's sensitivity for conductive loss spans 16–91% depending on fork frequency and the air-bone-gap threshold chosen (no pooled figure exists), combined fork protocols classify loss type at 76.86% sensitivity / 85.48% specificity in adults, and in children with middle-ear effusion both classic tests perform poorly; the only near-perfect figures come from a preliminary single-centre report of a new combined protocol
Stamped: 2026-11-28.
Evidence published: 2004–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
At the bedside, how accurately do the Rinne and Weber tuning-fork tests — at 256 Hz and 512 Hz, alone and combined — detect and classify hearing loss (conductive vs sensorineural) against pure-tone audiometry, in adults and in children?
Balance of the evidence
Four reports. The JAMA hearing-impairment Rational Clinical Examination (PMID 16434632) is GATED and counted nowhere; the whispered-voice question is homed at pack #7813 (whose question names the fork tests as comparators but asks the whisper question) and is not reopened. Kelly 2018 could not pool (heterogeneity and high patient-selection bias), so no pooled figure is printed. Bansal 2022's perfect figures describe its novel 3-step combination, not the classic Rinne/Weber pair, and print with that caveat.
MeSH: Audiometry · Hearing Loss/diagnosis* · Hearing Tests/instrumentation* · Humans · Audiometry, Pure-Tone/methods · Bone Conduction/physiology · Cross-Sectional Studies · Hearing Loss, Conductive/diagnosis*,physiopathology · Hearing Loss, Sensorineural/diagnosis*,physiopathology · Hearing Tests* · Humans · Predictive Value of Tests · Prospective Studies · Severity of Illness Index · Child · Child, Preschool · Double-Blind Method · Female · Hearing Loss, Conductive/diagnosis*,etiology · Hearing Tests/instrumentation* · Humans · Logistic Models · Male · Otitis Media with Effusion/complications* · Predictive Value of Tests · Prospective Studies
Cards (5)
Card 1 — Kelly systematic review 2018 (Otolaryngol Head Neck Surg — 17 studies, 3,158 participants): Rinne sensitivity/specificity for conductive loss ranged 43–91% / 50–100% at 256 Hz and 16–87% / 55–100% at 512 Hz; the audiometric threshold at which Rinne turns abnormal ranged 13–40 dB of conductive loss and Weber lateralisation at 2.5–4 dB of asymmetry; heterogeneity and high patient-selection bias precluded meta-analysis — no pooled figure may be printed
Study: Systematic review
Population: Seventeen studies, with 3,158 participants spanning adults and children, that report how accurately tuning fork tests (Weber and Rinne) perform against standard audiometry. Extracted data were corroborated by two independent evaluators, who also assessed risk of bias. Patient selection carries a high risk of bias in a majority of the studies.
Summary: Kelly systematic review 2018 (Otolaryngol Head Neck Surg — 17 studies, 3,158 participants): Rinne sensitivity/specificity for conductive loss ranged 43–91% / 50–100% at 256 Hz and 16–87% / 55–100% at 512 Hz; the audiometric threshold at which Rinne turns abnormal ranged 13–40 dB of conductive loss and Weber lateralisation at 2.5–4 dB of asymmetry; heterogeneity and high patient-selection bias precluded meta-analysis — no pooled figure may be printed
Result: For detecting conductive hearing loss, the Rinne test's sensitivity ranged from 43% to 91% and its specificity from 50% to 100% with a 256-Hz fork; with a 512-Hz fork the ranges were 16% to 87% for sensitivity and 55% to 100% for specificity. Tests switched from normal to abnormal once conductive hearing loss reached somewhere in the range 13 to 40 dB for the Rinne test, or asymmetry reached 2.5 to 4 dB for the Weber test. Meta-analysis was precluded by significant heterogeneity in tuning fork methods and in the audiometric thresholds used to define hearing loss. The authors conclude that reported test accuracy varies, and that clinicians should keep these differences in mind.
Watch out: A range spanning 16–91% sensitivity is a statement about the literature's inconsistency (fork frequency, technique, threshold definition, selected spectra) more than about any single performance figure; quoting either end alone would mislead in opposite directions.
Source: Kelly EA et al. Diagnostic Accuracy of Tuning Fork Tests for Hearing Loss: A Systematic Review. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2018. PMID: 29661046. Registry ID: none in the record. MeSH: Audiometry · Hearing Loss/diagnosis* · Hearing Tests/instrumentation* · Humans
Card 2 — Vikram combined-tests study 2004 (J Otolaryngol — 317 adult outpatients): the three-test combination (Rinne + Weber + absolute bone conduction) classified the type of hearing loss in all cases with overall sensitivity 76.86%, specificity 85.48% and validity 78.54% against audiometry — 58 response patterns were observed; the combination, not any single fork test, carries these figures
Study: Cross-sectional diagnostic accuracy study (primary report)
Population: A cross-sectional study of the tests of Rinne, Weber, and absolute bone conduction in 317 adult patients from the otolaryngology outpatient clinic selected at random; all possible patterns in the combination of three tests were explored and the findings compared with pure-tone audiometry.
Summary: Vikram combined-tests study 2004 (J Otolaryngol — 317 adult outpatients): the three-test combination (Rinne + Weber + absolute bone conduction) classified the type of hearing loss in all cases with overall sensitivity 76.86%, specificity 85.48% and validity 78.54% against audiometry — 58 response patterns were observed; the combination, not any single fork test, carries these figures
Result: Fifty-eight patterns were obtained, which were classified into 10 types according to the type of hearing loss. The type of hearing loss was determined in all cases, and the better ear was identified in many cases. The overall sensitivity was 76.86%, the specificity was 85.48%, and the validity was 78.54%. The authors conclude the combined tests, when combined and interpreted, can be reliable initial diagnostic tools for deciding referral or further audiometric testing.
Watch out: An explorative single-clinic study whose 58-pattern scheme was derived and judged in the same sample; 'determined in all cases' alongside 76.86% sensitivity means the scheme always gave an answer, not that the answer was usually right.
Source: Vikram KB et al. Combined tuning fork tests in hearing loss: explorative clinical study of the patterns. The Journal of otolaryngology. 2004. PMID: 15903203. Registry ID: none in the record. MeSH: Audiometry, Pure-Tone/methods · Bone Conduction/physiology · Cross-Sectional Studies · Hearing Loss, Conductive/diagnosis*,physiopathology · Hearing Loss, Sensorineural/diagnosis*,physiopathology · Hearing Tests* · Humans · Predictive Value of Tests · Prospective Studies · Severity of Illness Index
Card 3 — Behn children's study 2007 (J Otolaryngol — typed Clinical Trial; 58 children aged 2–11 with otitis media with effusion, blinded prospective): the Weber test showed no association with the air-bone gap at either frequency; Rinne responses tracked the gap (p < .04) but overall accuracy of both tests in predicting conductive loss in children with OME was poor — the negative paediatric limb, at headline weight
Study: Blinded prospective diagnostic accuracy study (primary report; typed Clinical Trial)
Population: Fifty-eight children with unilateral or bilateral otitis media with effusion, recruited from a tertiary paediatric otolaryngology clinic; Rinne and Weber tests were performed with 256 Hz and 512 Hz forks and responses correlated with the air-bone gap (ABG) on pure-tone audiometry.
Summary: Behn children's study 2007 (J Otolaryngol — typed Clinical Trial; 58 children aged 2–11 with otitis media with effusion, blinded prospective): the Weber test showed no association with the air-bone gap at either frequency; Rinne responses tracked the gap (p < .04) but overall accuracy of both tests in predicting conductive loss in children with OME was poor — the negative paediatric limb, at headline weight
Result: The Weber test did not show an association between the ABG and the lateralization response using either the 256 Hz (p = .484) or the 512 Hz tuning fork (p = .120). For the Rinne test, an increase in ABG was significantly associated with a higher rate of response air conduction < bone conduction using either fork (p < .04). Age was not associated with outcome for any of the tuning fork tests. The authors conclude the overall accuracy of the Rinne and Weber tuning fork tests in predicting conductive hearing loss associated with OME in children is poor.
Watch out: Cooperation and response reliability in 2–11-year-olds bound any bedside test; the poor performance here is specific to children with effusion and does not by itself condemn the tests in adults — just as the adult figures do not rescue them in children.
Source: Behn A et al. Accuracy of the Weber and Rinne tuning fork tests in evaluation of children with otitis media with effusion. The Journal of otolaryngology. 2007. PMID: 17942032. Registry ID: none in the record. MeSH: Child · Child, Preschool · Double-Blind Method · Female · Hearing Loss, Conductive/diagnosis*,etiology · Hearing Tests/instrumentation* · Humans · Logistic Models · Male · Otitis Media with Effusion/complications* · Predictive Value of Tests · Prospective Studies
Card 4 — Bansal 3-step test study 2022 (Indian J Otolaryngol Head Neck Surg — 108 adults / 216 ears): a novel combined 3-step tuning-fork protocol reported sensitivity and specificity of 100% for conductive and profound sensorineural loss, 97–100% sensitivity for sensorineural loss, 92% for mixed loss, overall 97% / 86% for classifying loss type against audiometry — perfect figures from a single-centre preliminary report of a new protocol, printed with that caveat; they describe the 3-step combination, not the classic Rinne/Weber pair
Study: Preliminary diagnostic accuracy study (primary report)
Population: A hospital-based observational study of a diagnostic tool in 108 adult patients (216 ears) who required hearing evaluation at a tertiary care medical college hospital ENT department; the novel 3-step tuning fork hearing test was designed to detect both the types and severities of hearing losses, and its sensitivity and specificity were assessed against pure tone audiometry.
Summary: Bansal 3-step test study 2022 (Indian J Otolaryngol Head Neck Surg — 108 adults / 216 ears): a novel combined 3-step tuning-fork protocol reported sensitivity and specificity of 100% for conductive and profound sensorineural loss, 97–100% sensitivity for sensorineural loss, 92% for mixed loss, overall 97% / 86% for classifying loss type against audiometry — perfect figures from a single-centre preliminary report of a new protocol, printed with that caveat; they describe the 3-step combination, not the classic Rinne/Weber pair
Result: The new 3-step test was found very effective (100% sensitivity and specificity) in detecting conductive and profound sensorineural hearing losses. The sensitivity in detecting sensorineural hearing loss was 97%–100%. The sensitivity was relatively low (92%) at detecting mixed hearing loss. The overall sensitivity and specificity of the 3-step test in detecting the types of hearing losses was 97% and 86% respectively. The authors conclude the test, which is simple and convenient, can be an important tool in otorhinolaryngology practice and primary care for detecting and screening the types and severities of hearing losses.
Watch out: The record styles itself a preliminary report: a new protocol, one centre, no independent replication, and perfect cells (100%/100%) that small samples produce readily. It cannot lift the classic pair's wide ranges on the card above.
Source: Bansal M et al. A Novel 3-Step Tuning Fork Hearing Test; Preliminary Report on Its Clinical Utility. Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India. 2022. PMID: 35813783. Registry ID: none in the record. MeSH: none in the record
Card 5 — Synthesis — PREDICTIVE PERFORMANCE, wide and threshold-dependent: 4 reports; the classic Rinne/Weber pair has no stable accuracy figure across studies, combined protocols do better in single studies, and the paediatric effusion limb is frankly poor
Study: Synthesis
Population: Composition: Kelly 2018 systematic review (17 studies, 3,158 participants) + Vikram 2004 adult primary (317 outpatients) + Behn 2007 paediatric primary (58 children) + Bansal 2022 preliminary protocol study (108 adults / 216 ears). Counted nowhere: the gated JAMA hearing RCE (PMID 16434632); the whispered-voice test is homed at pack #7813 and cross-pointed in prose only.
Summary: Synthesis — PREDICTIVE PERFORMANCE, wide and threshold-dependent: 4 reports; the classic Rinne/Weber pair has no stable accuracy figure across studies, combined protocols do better in single studies, and the paediatric effusion limb is frankly poor
Result: The fork frequency and the air-bone-gap threshold at which 'abnormal' is declared move the Rinne result more than any patient characteristic in this base (transition threshold 13–40 dB). Any clinical use should state its fork and threshold; any unqualified sensitivity figure for 'the Rinne test' is unsupported by this literature.
Watch out: Most included studies carry high patient-selection bias (the review's own assessment), so even the ranges may flatter performance in unselected clinic populations.
Source: Synthesis of the reports carded above; no additional source.