The cold pressor response in healthy humans — 4 laboratory studies (total N = 112): muscle sympathetic nerve activity more than doubles by the second minute of ice-water hand immersion and mean arterial pressure rises by about 22 mmHg, but one person's response reproduces only fairly (systolic intraclass correlation 0.57, within-person diastolic spread −21 to +20 mmHg)
Shelf #8933 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — EMERGING — the response is directly demonstrated but the base is four small laboratory studies (total N = 112): sympathetic nerve traffic rose from 230 ± 27 to 574 ± 73 units by 2 minutes (n = 25) and mean arterial pressure rose from 88 ± 9 to 110 ± 15 mmHg (n = 40), yet repeat testing in the same volunteers reproduced only fairly (systolic intraclass correlation 0.57; within-person diastolic differences −21 to +20 mmHg, n = 17) — the average response is real, the individual response is not a fixed trait on this evidence
Stamped: 2026-11-28.
Evidence published: 1979–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what is the cardiovascular response to the cold pressor test (immersion of a hand in ice water) — how much do arterial pressure, heart rate and muscle sympathetic nerve activity rise, how wide is the spread between 'hyper-responders' and 'hypo-responders', and how reproducible is the response when the same person is retested?
Balance of the evidence
PHYSIOLOGY — EMERGING — 4 laboratory studies, total N = 112 healthy humans (25 + 17 + 30 + 40). Every anchor is a small physiology-laboratory sample; none was recruited as a normative reference cohort, and the only reproducibility study (n = 17) finds a single cold pressor test unreliable at individual level. The neighbouring autonomic shelves home the Valsalva manoeuvre (#6634), the diving response (#6794) and standing/baroreflex responses — the cold pressor response itself was unhomed. PHYSIOLOGY — EMERGING: the pressor and sympathetic response exists at the scale printed on the cards; no reference range and no stable individual responder trait is established.
MeSH: Action Potentials · Adrenergic Fibers/physiology · Adult · Blood Pressure/drug effects · Cold Temperature · Efferent Pathways/physiology · Electrocardiography · Female · Heart Rate/drug effects · Humans · Male · Muscles/innervation · Norepinephrine/blood · Propranolol/pharmacology · Adolescent · Aged · Blood Pressure/physiology · Heart Rate/physiology · Middle Aged · Reference Values · Reproducibility of Results · Stress, Psychological/physiopathology · Cardiac Output/physiology · Immersion · Saliva/enzymology · Sympathetic Nervous System/physiology · Vascular Resistance/physiology · Vasoconstriction/physiology · Young Adult · alpha-Amylases/analysis · Arterial Pressure · Carotid Artery, Common/innervation · Healthy Volunteers · Time Factors · Vasodilation
Cards (5)
Card 1 — Victor microneurography study 1987 (Hypertension — 25 healthy subjects, hand in ice water for 2 min): muscle sympathetic nerve activity did not rise in the first 30 s, then climbed from 230 ± 27 to 386 ± 52 units by 1 min and 574 ± 73 units by 2 min; heart rate peaked in the first 30 s and was back to control by minute 2
Study: Physiological experiment (microneurography, primary report)
Population: 25 healthy subjects with peroneal-nerve microneurography (microelectrodes in a leg muscle nerve fascicle), arterial pressure and heart rate recorded during 2 minutes of hand immersion in ice water.
Summary: Victor microneurography study 1987 (Hypertension — 25 healthy subjects, hand in ice water for 2 min): muscle sympathetic nerve activity did not rise in the first 30 s, then climbed from 230 ± 27 to 386 ± 52 units by 1 min and 574 ± 73 units by 2 min; heart rate peaked in the first 30 s and was back to control by minute 2
Result: Arterial pressure rose steadily during the first and second minutes. Muscle sympathetic activity (burst frequency × amplitude) did not increase in the first 30 seconds but increased from 230 ± 27 to 386 ± 52 units (mean ± SE, p < 0.05) by the end of the first minute and to 574 ± 73 (p < 0.01) during the second minute. Heart rate increased maximally during the first 30 seconds and returned to control during the second minute; the heart-rate increases were abolished by beta-adrenergic blockade. Increases in muscle sympathetic activity correlated with increases in mean arterial pressure (r = 0.86, p < 0.01) and peripheral venous norepinephrine (r = 0.72, p < 0.05).
Watch out: The sympathetic figures are in the study's own integrated-activity units, not bursts/min, and the abstract is truncated at 250 words in the record — the absolute pressure rise in mmHg is not printed in the record and is not quoted on this shelf.
Source: Victor RG et al. Effects of the cold pressor test on muscle sympathetic nerve activity in humans. Hypertension (Dallas, Tex. : 1979). 1987. PMID: 3570420. Registry ID: none in the record. MeSH: Action Potentials · Adrenergic Fibers/physiology · Adult · Blood Pressure/drug effects · Cold Temperature · Efferent Pathways/physiology · Electrocardiography · Female · Heart Rate/drug effects · Humans · Male · Muscles/innervation · Norepinephrine/blood · Propranolol/pharmacology
Card 2 — Reproducibility study 1996 (Clinical Autonomic Research — 17 healthy volunteers, repeated 1- and 2-min tests): only fair test–retest reliability for the systolic response (intraclass correlation 0.57); within-person systolic differences ranged −16 to +13 mmHg and diastolic −21 to +20 mmHg, wider still across days — N = 17 printed on the face
Study: Reproducibility study (primary report)
Population: 17 healthy volunteers in two groups: group 1 (n = 11) performed a 1-minute cold pressor test three times in one day; group 2 (n = 6) performed a 2-minute test at the same time on three consecutive days; beat-to-beat pressure and heart rate by non-invasive monitoring; response defined as the 46- to 60-second mean minus the 15-second prestimulus baseline.
Summary: Reproducibility study 1996 (Clinical Autonomic Research — 17 healthy volunteers, repeated 1- and 2-min tests): only fair test–retest reliability for the systolic response (intraclass correlation 0.57); within-person systolic differences ranged −16 to +13 mmHg and diastolic −21 to +20 mmHg, wider still across days — N = 17 printed on the face
Result: In group 1, test–retest reliability was fair for the systolic blood pressure response (intraclass correlation coefficient R = 0.57); heart-rate and diastolic responses were more variable (R = 0.49 and R = 0.23). The intraindividual test–retest difference ranged from −8 to 11 beats/min (SD 4.3) for heart rate, −16 to 13 mmHg (SD 6.3) for systolic pressure, and −21 to 20 mmHg (SD 9.7) for diastolic pressure. Variability was even larger when the test was repeated on different days (group 2). The authors conclude the response pattern is not fairly constant for each individual and advise against using a single solitary cold pressor test, recommending replicated measurements and large samples.
Watch out: Seventeen volunteers, and the cross-day limb is only 6 people — the reliability coefficients are themselves imprecise. But the direction of the finding (wide within-person spread) is the shelf's caution, and it comes from the only repeat-testing study in the base.
Source: Fasano ML et al. Reproducibility of the cold pressor test: studies in normal subjects. Clinical autonomic research : official journal of the Clinical Autonomic Research Society. 1996. PMID: 8899250. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Blood Pressure/physiology · Cold Temperature · Female · Heart Rate/physiology · Humans · Male · Middle Aged · Reference Values · Reproducibility of Results · Stress, Psychological/physiopathology
Card 3 — Responder-phenotype study 2018 (Aerospace Medicine and Human Performance — 30 healthy volunteers, hand in 3.3 °C water for 5 min): 'hyper-responders' (systolic rise ≥22 mmHg) reached systolic 150 ± 14 vs 130 ± 14 mmHg in hypo-responders, and had lower baseline heart rate, cardiac output and salivary α-amylase
Study: Physiological experiment (primary report)
Population: 30 healthy volunteers who submerged one hand in cold water (3.3 ± 0.8 °C) for 5 minutes, with automated blood pressure, heart rate, impedance cardiography and beat-to-beat monitoring, and salivary α-amylase as a sympathetic biomarker; stratified post hoc into hyper-responders (systolic change ≥22 mmHg) and hypo-responders (<22 mmHg).
Summary: Responder-phenotype study 2018 (Aerospace Medicine and Human Performance — 30 healthy volunteers, hand in 3.3 °C water for 5 min): 'hyper-responders' (systolic rise ≥22 mmHg) reached systolic 150 ± 14 vs 130 ± 14 mmHg in hypo-responders, and had lower baseline heart rate, cardiac output and salivary α-amylase
Result: Hyper-responders had lower baseline heart rate (64 ± 7 vs 73 ± 9 bpm), cardiac output (5.6 ± 0.9 vs 6.9 ± 1.3 L/min) and salivary α-amylase (60 ± 37 vs 165 ± 122 U/mL). During immersion, hyper-responders had higher systolic pressure (150 ± 14 vs 130 ± 14 mmHg), diastolic pressure (91 ± 10 vs 81 ± 10 mmHg), mean arterial pressure (129 ± 17 vs 110 ± 9 mmHg) and systemic vascular resistance (1780 ± 640 vs 1290 ± 220 dyn·s·cm⁻⁵). The systolic change correlated with baseline salivary α-amylase (r = −0.455, P = 0.011) and baseline heart rate (r = −0.374, P = 0.042).
Watch out: The ≥22 mmHg hyper-responder cut-off is this study's own post hoc split of 30 people, not a validated threshold — it describes this sample's spread, and the reproducibility card above warns that the same person may not land on the same side of it on another day.
Source: Youssef M et al. Low Baseline Sympathetic Tone Correlates to a Greater Blood Pressure Change in the Cold Pressor Test. Aerospace medicine and human performance. 2018. PMID: 29789083. Registry ID: none in the record. MeSH: Adolescent · Adult · Blood Pressure/physiology · Cardiac Output/physiology · Cold Temperature · Female · Heart Rate/physiology · Humans · Immersion · Male · Saliva/enzymology · Sympathetic Nervous System/physiology · Vascular Resistance/physiology · Vasoconstriction/physiology · Young Adult · alpha-Amylases/analysis
Card 4 — Carotid-reactivity study 2020 (American Journal of Hypertension — 40 normotensive men aged 31–59): mean arterial pressure rose from 88 ± 9 to 110 ± 15 mmHg during the cold pressor test, peaking at 112 ± 38 s; carotid diameter dilated 4.4 ± 5.4% in most men but constricted in 6 of 40
Study: Physiological experiment (primary report)
Population: 40 normotensive men (aged 31–59 years) with no cardiovascular disease history and taking no medication; carotid artery diameter by ultrasound and beat-to-beat mean arterial pressure during the cold pressor test (the CAR test).
Summary: Carotid-reactivity study 2020 (American Journal of Hypertension — 40 normotensive men aged 31–59): mean arterial pressure rose from 88 ± 9 to 110 ± 15 mmHg during the cold pressor test, peaking at 112 ± 38 s; carotid diameter dilated 4.4 ± 5.4% in most men but constricted in 6 of 40
Result: Carotid artery reactivity was 4.4 ± 5.4%, peaking at 92 ± 43 seconds. Mean arterial pressure increased from 88 ± 9 mmHg to 110 ± 15 mmHg, peaking at 112 ± 38 seconds — significantly later than the diameter peak (P = 0.04). Resting mean arterial pressure correlated only weakly with the diameter response (r = 0.209, P = 0.197), and 6 men showed carotid constriction rather than dilation, with no difference in resting or increased pressure from the 34 dilators.
Watch out: Men only, and the cold pressor test here is a stimulus for a carotid question — its pressure figures are carded as the shelf's cleanest absolute pressor magnitude (a mean rise of about 22 mmHg), not as a normative reference range.
Source: Peace A et al. Role of Blood Pressure in Mediating Carotid Artery Dilation in Response to Sympathetic Stimulation in Healthy, Middle-Aged Individuals. American journal of hypertension. 2020. PMID: 31560753. Registry ID: none in the record. MeSH: Adult · Arterial Pressure · Carotid Artery, Common/innervation · Cold Temperature · Healthy Volunteers · Humans · Male · Middle Aged · Sympathetic Nervous System/physiology · Time Factors · Vasodilation
Card 5 — Synthesis — the cold pressor response: sympathetic traffic more than doubles within 2 minutes and pressure rises by roughly 20 mmHg on average, but the individual response is a moving target
Study: Synthesis
Population: 4 laboratory studies, total N = 112 healthy humans: Victor 1987 (n = 25), Fasano 1996 (n = 17), Youssef 2018 (n = 30), Peace 2020 (n = 40).
Summary: Synthesis — the cold pressor response: sympathetic traffic more than doubles within 2 minutes and pressure rises by roughly 20 mmHg on average, but the individual response is a moving target
Result: Direction is uniform across four decades of small studies: pressure rises steadily, muscle sympathetic nerve activity rises after a ~30-second lag and tracks the pressure rise (r = 0.86 in Victor), and heart rate rises early then recovers. Magnitude is not uniform: a ≥22 mmHg systolic rise defines one study's hyper-responders, carotid responses split 34 dilators to 6 constrictors at the same pressure stimulus, and repeat testing in the same person varies by up to ±20 mmHg diastolic. No large purpose-recruited normative cohort exists in this base. No report was refused.
Watch out: PHYSIOLOGY — EMERGING: the mechanism (sympathetic activation driving the pressor response) is directly demonstrated, but every anchor is a small laboratory sample and the only reproducibility study finds a single test unreliable — the shelf establishes the response's existence and scale, not a reference range.
Source: Synthesis of the reports carded above; no additional source.