SourceMed · Shelf #8941 in the ask interface

Estimated GFR equations vs measured GFR — development/validation (unique documented N = 17,387) plus two external validations: the 2021 race-free CKD-EPI creatinine equation carries median bias of −3.6 mL/min/1.73 m² in Black and +3.9 in non-Black validation participants, creatinine–cystatin C equations reach P30 above 90%, yet in transplant recipients only ~32% of estimates fall within 10% of measured GFR (P30 84%)

Shelf #8941 · Kidney, fluids & electrolytes

MEASUREMENT ACCURACY — accurate at population level, imprecise at individual level: in the 4,050-person validation population the 2021 race-free creatinine equation's median bias was −3.6 mL/min/1.73 m² in Black and +3.9 in non-Black participants, creatinine–cystatin C equations achieved bias within ±5 mL/min/1.73 m² with P30 above 90% (the proportion within 30% of measured GFR), and a 4,668-patient Danish cohort found median absolute bias of −0.2 (2021) vs −4.4 (2009) mL/min/1.73 m² — but in 415 transplant recipients P30 was 84% and P10 only ~32–33% for every equation generation, so individual estimates near a threshold remain unreliable

Stamped: 2026-11-28.

Evidence published: 2021–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately do the current GFR estimating equations (2021 race-free CKD-EPI creatinine, creatinine–cystatin C, and EKFC equations, against their 2009/2012 predecessors) estimate measured GFR — what are their bias and P30/P10 accuracy overall, by race group, in a European measured-GFR cohort, and in kidney transplant recipients?

Balance of the evidence

MEASUREMENT ACCURACY — composition: 1 development + validation report, 1 comparative evaluation in the same 4,050-person validation population (overlap stated on its card and in the total), and 2 independent external validations (Denmark n = 4,668; transplant n = 415). Total unique documented N = 17,387. This is a caution-class shelf: accuracy of an estimate against measured GFR only. Cross-point in prose only: shelf #6958 homes agreement among the measured-GFR reference methods themselves — a different question from equation accuracy.

MeSH: Adult · Aged · Algorithms · Black People · Creatinine/blood · Cystatin C/blood · Datasets as Topic · Female · Glomerular Filtration Rate · Humans · Male · Middle Aged · Racial Groups · Renal Insufficiency, Chronic/blood/epidemiology/ethnology/physiopathology · United States/epidemiology · Black or African American · Creatinine · Cystatin C · Renal Insufficiency, Chronic · Cross-Sectional Studies · Kidney Transplantation · Renal Insufficiency, Chronic/epidemiology/surgery

Cards (5)

Card 1 — Inker CKD-EPI development and validation 2021 (New England Journal of Medicine — development 8,254 participants (creatinine) and 5,352 (creatinine–cystatin C); independent validation 4,050 participants, 14.3% Black): the new race-free creatinine equation underestimated measured GFR in Black participants (median bias −3.6 mL/min/1.73 m²) and overestimated it in non-Black participants (+3.9); the creatinine–cystatin C equation was more accurate with smaller between-group differences; for all equations ≥85% of estimates fell within 30% of measured GFR (P30)

Study: Equation development and validation study (primary report)

Population: Development data from 10 studies (8,254 participants, 31.5% Black) for creatinine equations and 13 studies (5,352 participants, 39.7% Black) for creatinine–cystatin C equations; validation in 12 studies (4,050 participants, 14.3% Black) against measured GFR.

Summary: Inker CKD-EPI development and validation 2021 (New England Journal of Medicine — development 8,254 participants (creatinine) and 5,352 (creatinine–cystatin C); independent validation 4,050 participants, 14.3% Black): the new race-free creatinine equation underestimated measured GFR in Black participants (median bias −3.6 mL/min/1.73 m²) and overestimated it in non-Black participants (+3.9); the creatinine–cystatin C equation was more accurate with smaller between-group differences; for all equations ≥85% of estimates fell within 30% of measured GFR (P30)

Result: In validation, the then-current race-based creatinine equation overestimated measured GFR in Black participants (median 3.7 mL/min/1.73 m²; 95% CI 1.8 to 5.4) and slightly in non-Black participants (0.5; 0.0 to 0.9). Simply omitting the race adjustment underestimated measured GFR in Black participants (median 7.1; 5.9 to 8.8). The new race-free creatinine equation underestimated in Black participants (median 3.6; 1.8 to 5.5) and overestimated in non-Black participants (median 3.9; 3.4 to 4.4). For all equations, 85% or more of estimates in both groups were within 30% of measured GFR. The new creatinine–cystatin C equations without race were more accurate than the creatinine-only equations, with smaller differences between race groups.

Watch out: The developers' own validation — independent data, but the same programme. The honest headline is the trade-off the paper itself states: removing race without adding cystatin C redistributes a few mL/min/1.73 m² of median bias between groups rather than eliminating it; P30 ≥85% also means up to 15% of individual estimates miss measured GFR by more than 30%.

Source: Inker LA et al. New Creatinine- and Cystatin C-Based Equations to Estimate GFR without Race. The New England journal of medicine. 2021. PMID: 34554658. Registry ID: none in the record. MeSH: Adult · Aged · Algorithms · Black People · Creatinine/blood · Cystatin C/blood · Datasets as Topic · Female · Glomerular Filtration Rate · Humans · Male · Middle Aged · Racial Groups · Renal Insufficiency, Chronic/blood/epidemiology/ethnology/physiopathology · United States/epidemiology · Black or African American

Card 2 — Inker comparative evaluation 2023 (Journal of the American Society of Nephrology — the same pooled 4,050-adult validation population as the 2021 report, counted once in this shelf's total): CKD-EPI and EKFC creatinine–cystatin C equations performed best overall (bias within ±5 mL/min/1.73 m² and P30 above 90%), with fewer race, sex and age subgroup differences than creatinine-only equations, whose larger differences reflected regional population differences in creatinine

Study: Comparative equation evaluation (primary report; validation population overlaps the 2021 card — counted once)

Population: An independent study population of 4,050 adults pooled from 12 studies — the same validation population as the 2021 development report's validation set (overlap stated in the record's abstract: an independent population for the EKFC equations, the CKD-EPI validation population for the 2021 equations); mean measured GFR 76.4 (SD 29.6) mL/min/1.73 m², mean age 57.0 (17.4) years, 38% women, 14% Black participants.

Summary: Inker comparative evaluation 2023 (Journal of the American Society of Nephrology — the same pooled 4,050-adult validation population as the 2021 report, counted once in this shelf's total): CKD-EPI and EKFC creatinine–cystatin C equations performed best overall (bias within ±5 mL/min/1.73 m² and P30 above 90%), with fewer race, sex and age subgroup differences than creatinine-only equations, whose larger differences reflected regional population differences in creatinine

Result: Coefficients for creatinine, cystatin C, age and sex were similar between the CKD-EPI and EKFC equations. Creatinine–cystatin C equations performed better in the overall population (bias <±5 mL/min/1.73 m² and P30 >90%) than creatinine-only or cystatin-C-only equations, with fewer differences among race, sex and age subgroups. Larger differences among creatinine-only equations reflected regional population differences in non-GFR determinants of creatinine. The authors conclude it is not possible to maximise both accuracy and uniformity with a single creatinine-only equation across regions, and that wider cystatin C use could maximise both.

Watch out: Same 4,050 people as the previous card's validation set — this shelf counts them once, and the card is here for the CKD-EPI-versus-EKFC comparison, not as independent confirmation of the 2021 figures. One programme again (Inker is senior author on both).

Source: Inker LA et al. CKD-EPI and EKFC GFR Estimating Equations: Performance and Other Considerations for Selecting Equations for Implementation in Adults. Journal of the American Society of Nephrology : JASN. 2023. PMID: 37796982. Registry ID: none in the record. MeSH: Adult · Female · Humans · Male · Middle Aged · Creatinine · Cystatin C · Glomerular Filtration Rate · Renal Insufficiency, Chronic · Aged

Card 3 — Munch Danish validation 2023 (Clinical Kidney Journal — 4,668 patients with GFR measured by ⁵¹Cr-EDTA plasma clearance at one Danish hospital, 2010–2018; the record carries no MeSH): the 2021 race-free equation's median absolute bias was −0.2 versus −4.4 mL/min/1.73 m² for the 2009 equation (non-Black form), with similar accuracy, precision and CKD-stage classification overall — but the 2009 equation performed slightly better below a measured GFR of 60

Study: External validation study (primary report)

Population: A predominantly White Danish cohort of 4,668 patients with measured GFR (⁵¹Cr-EDTA plasma clearance), including 3,313 cancer patients and 239 potential living kidney donors, comparing the 2021 race-free CKD-EPI creatinine equation with the 2009 equation in its non-Black form.

Summary: Munch Danish validation 2023 (Clinical Kidney Journal — 4,668 patients with GFR measured by ⁵¹Cr-EDTA plasma clearance at one Danish hospital, 2010–2018; the record carries no MeSH): the 2021 race-free equation's median absolute bias was −0.2 versus −4.4 mL/min/1.73 m² for the 2009 equation (non-Black form), with similar accuracy, precision and CKD-stage classification overall — but the 2009 equation performed slightly better below a measured GFR of 60

Result: In the total cohort, the 2021 equation showed a slightly lower median absolute bias (−0.2 versus −4.4 mL/min/1.73 m²) and similar accuracy, precision and correct CKD-stage classification compared with the 2009 equation; it also performed slightly better in the cancer and potential-donor subgroups. Stratified by CKD stage, the 2009 equation performed slightly better than the 2021 equation among patients with measured GFR below 60 mL/min/1.73 m², though the authors judged the differences clinically insignificant.

Watch out: A referred hospital population with a clinical reason for measured GFR — not a general-population sample — and almost entirely White, so it can judge the race-free equation's behaviour in Europeans but says nothing about performance in Black patients, the group the redesign most concerned.

Source: Munch PV et al. Performance of the race-free CKD-EPI creatinine-based eGFR equation in a Danish cohort with measured GFR. Clinical kidney journal. 2023. PMID: 38046001. Registry ID: none in the record. MeSH: none in the record

Card 4 — Hundemer transplant validation 2022 (American Journal of Kidney Diseases — 415 stable kidney transplant recipients in Canada and New Zealand, measured GFR by radiolabelled DTPA; mean measured GFR 53 ± 19 mL/min/1.73 m²): 2021 and 2009 equations performed similarly — median bias −0.2 (2021 creatinine) vs −2.3 (2009), P30 84% for both; the 2021 creatinine–cystatin C equation's P30 was 83% with P10 only 32% — one in three estimates within 10% of measured GFR

Study: External validation study (primary report)

Population: 415 stable kidney transplant recipients (87% White, 3% Black, 10% other) with same-day creatinine, cystatin C and measured GFR (radiolabelled diethylenetriaminepentaacetic acid); six equations compared (2009, 2012 and 2021 CKD-EPI variants and MDRD) for bias, precision (interquartile range), accuracy (P10/P20/P30, root mean square error, mean absolute error) and CKD-stage classification.

Summary: Hundemer transplant validation 2022 (American Journal of Kidney Diseases — 415 stable kidney transplant recipients in Canada and New Zealand, measured GFR by radiolabelled DTPA; mean measured GFR 53 ± 19 mL/min/1.73 m²): 2021 and 2009 equations performed similarly — median bias −0.2 (2021 creatinine) vs −2.3 (2009), P30 84% for both; the 2021 creatinine–cystatin C equation's P30 was 83% with P10 only 32% — one in three estimates within 10% of measured GFR

Result: The 2009 and 2021 creatinine equations showed similar median bias (−2.3 vs −0.2 mL/min/1.73 m²), precision (14.5 vs 14.9) and accuracy (P10/P20/P30 of 32%/65%/84% vs 33%/63%/84%). The 2012 and 2021 creatinine–cystatin C equations were likewise similar (median bias −3.6 vs 0.3; P10/P20/P30 32%/63%/80% vs 32%/67%/83%). Correct CKD-stage classification was similar across all equations. The authors note the moderate sample size, few patients with GFR below 30, and the predominantly White population as limitations.

Watch out: Transplant kidneys on calcineurin inhibitors are a hard case for creatinine (muscle mass, tubular secretion, steroids) — the P10 of ~32% is this population's figure, not the general population's. Carded as the shelf's individual-precision floor: even the best equation puts only a third of estimates within 10% here.

Source: Hundemer GL et al. Performance of the 2021 Race-Free CKD-EPI Creatinine- and Cystatin C-Based Estimated GFR Equations Among Kidney Transplant Recipients. American journal of kidney diseases : the official journal of the National Kidney Foundation. 2022. PMID: 35588905. Registry ID: none in the record. MeSH: Creatinine · Cross-Sectional Studies · Cystatin C · Glomerular Filtration Rate · Humans · Kidney Transplantation · Renal Insufficiency, Chronic/epidemiology/surgery

Card 5 — Synthesis — eGFR equation accuracy: population-level bias is small (median within ±4 mL/min/1.73 m²) and P30 runs 84% to above 90%, but individual-level precision is the standing limitation — P10 of only ~32–33% in transplant recipients — and creatinine-only equations cannot be simultaneously accurate and uniform across populations, which is the evidence case for adding cystatin C

Study: Synthesis

Population: Composition: 1 development + validation report (development 8,254 creatinine / 5,352 creatinine–cystatin C participants; validation 4,050) + 1 comparative evaluation in the same 4,050-person validation population (counted once) + 2 independent external validations (4,668 Danish measured-GFR patients; 415 transplant recipients). Total unique documented N = 17,387 (8,254 + 4,050 + 4,668 + 415; the development creatinine–cystatin subset is inside the development programme's studies and is not double-added).

Summary: Synthesis — eGFR equation accuracy: population-level bias is small (median within ±4 mL/min/1.73 m²) and P30 runs 84% to above 90%, but individual-level precision is the standing limitation — P10 of only ~32–33% in transplant recipients — and creatinine-only equations cannot be simultaneously accurate and uniform across populations, which is the evidence case for adding cystatin C

Result: Across settings the pattern repeats: swapping equation generations moves median bias by a few mL/min/1.73 m² and barely moves P30 (84% in transplant recipients for both 2009 and 2021 creatinine equations; above 90% for creatinine–cystatin C equations in the pooled validation population). The shelf's two messages are therefore distinct: for population and staging purposes the current equations are accurate; for an individual patient near a decision threshold, an estimate can sit more than 30% from measured GFR in roughly 1 in 10 to 1 in 6 cases on this base. Cross-point in prose only: the measured-GFR methods-agreement shelf (#6958) homes the reference methods themselves. No report was refused.

Watch out: MEASUREMENT ACCURACY here is judged against measured GFR by clearance methods, themselves imperfect references (#6958) — equation 'error' includes reference error. Race-group bias figures are properties of the US development/validation populations and do not transfer unchanged to other ancestries or regions, as the Danish card shows.

Source: Synthesis of the reports carded above; no additional source.