PSMA PET-CT before curative-intent treatment of high-risk prostate cancer: accuracy 92% versus 65% for CT plus bone scan, with sensitivity 85% / specificity 98% versus sensitivity 38% / specificity 91% (proPSMA)
Shelf #8955 · Cancer
MEASUREMENT ACCURACY — in one randomised multicentre accuracy trial (documented N = 302), PSMA PET-CT accuracy for pelvic nodal or distant metastatic disease was 92% versus 65% for conventional imaging (a 27% absolute advantage), with sensitivity 85% / specificity 98% for PSMA PET-CT versus sensitivity 38% / specificity 91% for conventional imaging; accuracy against a 6-month composite reference standard is not the same as showing better patient outcomes, and a single accuracy trial is a caution-class shelf.
Stamped: 2026-11-28.
Evidence published: 2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In men with high-risk localised prostate cancer being considered for curative-intent surgery or radiotherapy, how accurately does gallium-68 PSMA-11 PET-CT identify pelvic nodal or distant metastatic disease compared with conventional imaging (CT plus bone scan)?
Balance of the evidence
MEASUREMENT ACCURACY — in one randomised multicentre accuracy trial (documented N = 302), PSMA PET-CT accuracy for pelvic nodal or distant metastatic disease was 92% versus 65% for conventional imaging (a 27% absolute advantage), with sensitivity 85% / specificity 98% for PSMA PET-CT versus sensitivity 38% / specificity 91% for conventional imaging; management changed more often after PSMA PET-CT (28% versus 15%) and radiation exposure was lower (8.4 mSv versus 19.2 mSv). Composition: 1 trial (proPSMA) with 1 carded report.
MeSH: Aged · Antigens, Surface · Biomarkers · Glutamate Carboxypeptidase II · Humans · Lymphatic Metastasis · Male · Middle Aged · Neoplasm Metastasis · Positron Emission Tomography Computed Tomography · Prospective Studies · Prostatic Neoplasms · Sensitivity and Specificity · Whole Body Imaging
Cards (2)
Card 1 — proPSMA: accuracy 92% versus 65%; sensitivity 85% / specificity 98% versus sensitivity 38% / specificity 91% (Hofman 2020, The Lancet — randomised accuracy trial, 302 men)
Study: Randomized controlled trial (multicentre diagnostic accuracy trial with crossover second-line imaging)
Population: 302 men with biopsy-proven prostate cancer and high-risk features at ten Australian hospitals, randomly assigned to conventional imaging with CT and bone scanning (152) or gallium-68 PSMA-11 PET-CT (150) as first-line imaging before curative-intent surgery or radiotherapy; 295 (98%) had follow-up, and 87 (30%) had pelvic nodal or distant metastatic disease by the predefined reference standard (histopathology, imaging and biochemistry at 6 months).
Summary: proPSMA: accuracy 92% versus 65%; sensitivity 85% / specificity 98% versus sensitivity 38% / specificity 91% (Hofman 2020, The Lancet — randomised accuracy trial, 302 men)
Result: PSMA PET-CT had a 27% (95% CI 23–31) greater accuracy than conventional imaging (92% [88–95] versus 65% [60–69]; p < 0.0001). Conventional imaging had lower sensitivity (38% [24–52] versus 85% [74–96]) and specificity (91% [85–97] versus 98% [95–100]) than PSMA PET-CT. First-line conventional imaging conferred management change less frequently (23 [15%] men versus 41 [28%] men; p = 0.008) and had more equivocal findings (23% versus 7%). Radiation exposure was 10.9 mSv higher for conventional imaging than for PSMA PET-CT (19.2 mSv versus 8.4 mSv; p < 0.001). Reporter agreement for PSMA PET-CT was high (κ = 0.87 for nodal and κ = 0.88 for distant metastases).
Watch out: The reference standard is a 6-month composite of histopathology, imaging and biochemistry, not universal surgical pathology — verification is partial, and the trial measures accuracy and management change, not survival, quality of life, or the harm of treatment changes made on the extra lesions found.
Source: Hofman MS et al. Prostate-specific membrane antigen PET-CT in patients with high-risk prostate cancer before curative-intent surgery or radiotherapy (proPSMA): a prospective, randomised, multicentre study. Lancet (London, England). 2020. PMID: 32209449. Registry ID: none in the record (the record's abstract names the Australian New Zealand Clinical Trials Registry number ANZCTR12617000005358 in its text; no ClinicalTrials.gov ID is carried). MeSH: Aged · Antigens, Surface · Biomarkers · Glutamate Carboxypeptidase II · Humans · Lymphatic Metastasis · Male · Middle Aged · Neoplasm Metastasis · Positron Emission Tomography Computed Tomography · Prospective Studies · Prostatic Neoplasms · Sensitivity and Specificity · Whole Body Imaging
Card 2 — Synthesis — MEASUREMENT ACCURACY: a large, consistent accuracy advantage in a single trial; outcome benefit untested
Study: Synthesis
Population: 1 trial: proPSMA (302 men; 295 with follow-up). Documented N = 302.
Summary: Synthesis — MEASUREMENT ACCURACY: a large, consistent accuracy advantage in a single trial; outcome benefit untested
Result: Every accuracy measure points the same way — overall accuracy, sensitivity and specificity labelled in words above, nodal and distant subgroups, fewer equivocal findings, and high reporter agreement. The open questions are downstream: whether acting on PSMA-only lesions improves outcomes, and performance outside high-risk pre-curative-intent staging. The stamp is a measurement-accuracy statement, not a benefit claim.
Watch out: Men had high-risk features and a 30% prevalence of nodal or distant disease; sensitivity and specificity labelled in words on this shelf will read differently in lower-risk populations with lower prevalence.
Source: Synthesis of the reports carded above; no additional source.