Microstents with cataract surgery for open-angle glaucoma: Hydrus and iStent inject

Shelf #896 · Eyes, skin, nose & allergy

LIKELY

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

Does adding a Schlemm-canal or trabecular microstent to cataract surgery lower intraocular pressure and drop burden versus cataract surgery alone?

Balance of the evidence

LIKELY: Two randomised, single-masked device trials with washed-out pressure endpoints agree: HORIZON (Hydrus, 556 eyes) found ≥20% unmedicated pressure reduction at 24 months in 77.3% vs 57.8% (difference 19.5 percentage points) and the iStent inject pivotal trial (505 eyes) found 75.8% vs 61.9%, with mean extra pressure lowering of about 2.3 and 1.6 mmHg over cataract surgery alone and roughly 0.4 fewer medications. Device trials cannot be double-masked, and are labelled as such; the washed-out objective endpoint and two-trial concordance carry LIKELY for a modest incremental effect.

MeSH: Antihypertensive Agents/administration & dosage · Aqueous Humor/physiology · Cataract/etiology,physiopathology · Glaucoma, Open-Angle/physiopathology,surgery · Gonioscopy · Intraocular Pressure/physiology · Lens Implantation, Intraocular

Cards (3)

Card 1 — Samuelson 2019 (HORIZON): Hydrus microstent plus cataract surgery beat cataract surgery alone on washed-out pressure at 24 months

Study: Prospective, multicentre, single-masked, randomised controlled trial

Population: 556 eyes (369 Hydrus, 187 no stent, randomised 2:1 after phacoemulsification) in subjects with primary open-angle glaucoma, visually significant cataract, and washed-out diurnal intraocular pressure 22–34 mmHg; the abstract does not state mean age or sex mix.

Summary: HORIZON (2019): Hydrus microstent plus cataract surgery beat cataract surgery alone — a ≥20% pressure fall in 77.3% vs 57.8% of eyes at 24 months.

Result: At 24 months, unmedicated diurnal pressure had fallen by ≥20% in 77.3% of Hydrus eyes vs 57.8% of control eyes (difference 19.5%, 95% CI 11.2% to 27.8%; P<0.001). Mean unmedicated pressure reduction was −7.6 (SD 4.1) mmHg vs −5.3 (3.9) mmHg (difference −2.3 mmHg, −3.0 to −1.6; P<0.001). Mean medications fell from 1.7 at baseline to 0.3 vs 0.7 (difference −0.4; P<0.001). No serious ocular adverse events were related to the microstent, and safety parameters did not differ significantly between groups.

Watch out: Single-masked device trial (the surgeon knows), and cataract surgery alone does much of the work — the stent's own increment is the 2.3 mmHg and 0.4 medications, in mild-to-moderate disease only.

Source: Samuelson TW et al. A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract: The HORIZON Study. Ophthalmology. 2019;126(1):29-37. PMID: 29945799. Registry ID: ClinicalTrials.gov NCT01539239, from the record's databank fields.

Card 2 — Samuelson 2019 (iStent inject pivotal): trabecular micro-bypass plus cataract surgery beat cataract surgery alone at 24 months

Study: Prospective, randomised, single-masked, concurrently controlled, multicentre pivotal trial

Population: 505 eyes with mild-to-moderate primary open-angle glaucoma and cataract (387 iStent inject, 118 control, randomised 3:1 intraoperatively after cataract surgery), with medicated pressure ≤24 mmHg on 1–3 medications and unmedicated diurnal pressure 21–36 mmHg; the abstract does not state mean age or sex mix.

Summary: iStent inject pivotal (2019): a ≥20% unmedicated pressure reduction in 75.8% vs 61.9% at 24 months.

Result: At 24 months, ≥20% reduction in unmedicated diurnal pressure occurred in 75.8% of treated eyes vs 61.9% of controls (P=0.005); mean reduction was 7.0 (SD 4.0) mmHg vs 5.4 (3.7) mmHg (P<0.001) — an increment of about 1.6 mmHg. Medication-free pressure ≤18 mmHg at 24 months: 63.2% vs 50.0% (difference 13.2%, 95% CI 2.9 to 23.4). Among responders, 84% of treated eyes vs 67% of controls were medication-free at 23 months. The safety profile was favourable and similar to control through 2 years.

Watch out: Same design limits as HORIZON — single-masked, industry pivotal trial, mild-to-moderate disease — and its pressure increment (about 1.6 mmHg) is smaller than Hydrus's, a comparison the two trials were not designed to make head-to-head.

Source: Samuelson TW et al. Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results. Ophthalmology. 2019;126(6):811-821. PMID: 30880108. Registry ID: none in the record's databank fields — the fetched record carries no databank registry entry.

Card 3 — Synthesis: a real but modest stent increment over cataract surgery alone — LIKELY

Study: Synthesis

Population: Synthesis of the cards above: HORIZON (556 eyes, Hydrus) and the iStent inject pivotal trial (505 eyes).

Summary: A real but modest stent increment over cataract surgery alone — LIKELY.

Result: Both stents, tested independently against the same control (cataract surgery alone, with medication washout), add roughly 1.6–2.3 mmHg of pressure lowering and free about two-thirds to three-quarters of eyes from drops at 2 years in responder terms. LIKELY for that modest claim. The currency sweep found a newer Swedish randomised trial comparing cataract surgery alone with cataract surgery combined with iStent inject W or a Kahook goniotomy device, plus an iStent-vs-goniotomy trial and a Hydrus cost-effectiveness analysis; all are fenced here as pointers, not carded — none displaces the two pivotal anchors for the stent-vs-no-stent question. Laser-first vs drops (drafted #609) and tube shunt vs trabeculectomy for advanced disease (drafted #617) are different rungs of the glaucoma ladder, fenced likewise.

Watch out: Neither trial enrolled advanced glaucoma or eyes not already needing cataract surgery; extrapolating the increment to standalone stent surgery is beyond these cards.

Source: Synthesis of Samuelson TW et al. Ophthalmology. 2019;126(1):29-37. PMID: 29945799; Samuelson TW et al. Ophthalmology. 2019;126(6):811-821. PMID: 30880108. Registry IDs as on the individual cards.