SourceMed · Shelf #8963 in the ask interface

GreenLight photoselective vaporisation versus TURP — 4 randomised trials (documented N = 758): symptom relief and flow noninferior to TURP in the 281-patient GOLIATH trial and sustained at 2 years, with shorter catheter time and hospital stay; the older 80-W trial still shows a 14.3% retreatment rate at 5 years

Shelf #8963 · Urology & men’s health

POSSIBLE (benefit) — 4 independent randomised trials (documented N = 758): GreenLight vaporisation was noninferior to TURP for symptom score and flow in the largest trial (GOLIATH, 281 patients, sustained at 2 years; complication-free 83.6% versus 78.9%) and matched TURP in three smaller trials of earlier laser generations, with consistently shorter catheterisation and hospital stay; benefit is equivalence-plus-recovery, not better symptom relief, and 5-year retreatment was 14.3% versus 11.9% in the one long trial — that caps the stamp at POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2011–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In men with lower urinary tract symptoms due to benign prostatic obstruction, does GreenLight photoselective vaporisation of the prostate (80-W, 120-W HPS and 180-W XPS systems) relieve symptoms and improve flow as well as transurethral resection of the prostate (TURP), and how do complications, catheter time, hospital stay and retreatment compare?

Balance of the evidence

POSSIBLE (benefit) — composition: 4 independent randomised trials, documented N = 758 (281 + 100 + 139 + 238 randomised; the 5-year trial's analysed N at 5 years was 105 of 238 randomised, stated on its card). The trials test three laser generations (180-W XPS in GOLIATH; 120-W HPS in two trials; 80-W in the 5-year trial) against monopolar or mixed TURP, counted together as one device family with generations labelled on each card. Symptom and flow outcomes are equivalent wherever measured; the consistent advantages are shorter catheter time and hospital stay, and the consistent caution is retreatment over time. POSSIBLE: GreenLight vaporisation is a genuine alternative to TURP with equal symptom relief and a faster early recovery, not a superior one.

MeSH: Follow-Up Studies · Humans · Lasers, Solid-State/adverse effects,therapeutic use · Male · Organ Size · Patient Satisfaction · Prospective Studies · Prostate/pathology · Prostate-Specific Antigen/blood · Prostatic Hyperplasia/blood,pathology,surgery · Quality of Life · Severity of Illness Index · Surveys and Questionnaires · Transurethral Resection of Prostate/adverse effects,methods · Treatment Outcome · Urinary Incontinence/etiology

Cards (5)

Card 1 — GOLIATH 2-year results (Thomas 2016, European Urology — multicentre RCT, 281 patients, 29 centres): noninferiority of 180-W GreenLight XPS to TURP on IPSS, Qmax and freedom from complications at 6 months was sustained at 2 years; complication-free through 24 months 83.6% (XPS) versus 78.9% (TURP)

Study: Randomized controlled trial (multicentre, noninferiority; 2-year report of GOLIATH)

Population: 281 patients with benign prostatic obstruction randomised at 29 centres in 9 European countries; 136 treated with 180-W GreenLight XPS photoselective vaporisation and 133 with conventional (monopolar or bipolar) TURP; primary outcome IPSS with a noninferiority margin of 3 points; patients and treating physicians were not blinded.

Summary: GOLIATH 2-year results (Thomas 2016, European Urology — multicentre RCT, 281 patients, 29 centres): noninferiority of 180-W GreenLight XPS to TURP on IPSS, Qmax and freedom from complications at 6 months was sustained at 2 years; complication-free through 24 months 83.6% (XPS) versus 78.9% (TURP)

Result: Noninferiority of GreenLight XPS on IPSS, Qmax, and freedom from complications was demonstrated at 6 months and sustained at 2 years. The proportion of patients complication-free through 24 months was 83.6% with XPS versus 78.9% with TURP. Reductions in prostate volume and prostate specific antigen were similar in both arms and sustained. At 6 months (the trial's first report), time until stable health status, length of catheterisation, and length of hospital stay were superior with XPS (p<0.001), and the early reintervention rate within 30 days was three times higher after TURP (p=0.025), with overall postoperative reintervention rates not significantly different at 6 or 12 months; the 1-year complication-free rate was 84.6% after XPS versus 80.5% after TURP.

Watch out: Noninferiority on symptoms is the claim — not superiority. Surgeons and patients were unblinded, the TURP arm mixed monopolar and bipolar resection, and the 6- and 12-month GOLIATH reports (PMIDs 24331152, 25219699) are the same trial, counted once here.

Source: Thomas JA et al. A Multicenter Randomized Noninferiority Trial Comparing GreenLight-XPS Laser Vaporization of the Prostate and Transurethral Resection of the Prostate for the Treatment of Benign Prostatic Obstruction: Two-yr Outcomes of the GOLIATH Study. European urology. 2016. PMID: 26283011. Registry ID: NCT01218672. MeSH: Follow-Up Studies · Humans · Lasers, Solid-State/adverse effects,therapeutic use · Male · Organ Size · Patient Satisfaction · Prospective Studies · Prostate/pathology · Prostate-Specific Antigen/blood · Prostatic Hyperplasia/blood,pathology,surgery · Quality of Life · Severity of Illness Index · Surveys and Questionnaires · Transurethral Resection of Prostate/adverse effects,methods · Treatment Outcome · Urinary Incontinence/etiology

Card 2 — 120-W HPS trial with 2-year follow-up (Capitán 2011, European Urology — RCT, 100 patients): IPSS fell −15.7 with vaporisation versus −14.9 with TURP (p = 0.48) and Qmax rose +14.5 versus +13.1 mL/s (p = 0.65); hospital stay and catheter time significantly shorter with vaporisation

Study: Randomized controlled trial (single-centre, 2-year follow-up)

Population: 100 patients with lower urinary tract symptoms due to benign prostatic hyperplasia, 50 randomised to GreenLight HPS 120-W laser vaporisation and 50 to TURP; main endpoints IPSS, quality of life and Qmax at 2 years; 5 patients lost to follow-up, analysed by last observation carried forward.

Summary: 120-W HPS trial with 2-year follow-up (Capitán 2011, European Urology — RCT, 100 patients): IPSS fell −15.7 with vaporisation versus −14.9 with TURP (p = 0.48) and Qmax rose +14.5 versus +13.1 mL/s (p = 0.65); hospital stay and catheter time significantly shorter with vaporisation

Result: Both laser vaporisation and TURP resulted in the same IPSS reduction at 2 years (−15.7 and −14.9, respectively; p = 0.48) and the same gain in Qmax (+14.5 mL/s and +13.1 mL/s, respectively; p = 0.65). Quality of life was equivalent. No statistically significant differences were detected in complication rates: in the vaporisation group 3 patients were readmitted and 2 developed a urethral stricture; in the TURP group 2 were readmitted, 6 developed a urethral stricture, and 2 developed bladder neck sclerosis. In-hospital stay and time to catheter removal were significantly shorter with vaporisation.

Watch out: Only 50 patients per arm — underpowered for complication differences, as its authors state, and unblinded by the nature of the intervention. The stricture counts (2 versus 6) are too small to read as a safety verdict.

Source: Capitán C et al. GreenLight HPS 120-W laser vaporization versus transurethral resection of the prostate for the treatment of lower urinary tract symptoms due to benign prostatic hyperplasia: a randomized clinical trial with 2-year follow-up. European urology. 2011. PMID: 21658839. Registry ID: none in the record. MeSH: Aged · Humans · Laser Therapy/instrumentation,methods · Lost to Follow-Up · Lower Urinary Tract Symptoms/surgery · Male · Middle Aged · Postoperative Complications/epidemiology · Prostate/surgery · Prostatic Hyperplasia/surgery · Quality of Life · Severity of Illness Index · Transurethral Resection of Prostate/methods · Treatment Outcome

Card 3 — French multicentre 120-W trial (Lukacs 2012, European Urology — RCT, 139 patients): noninferiority on IPSS at 12 months NOT demonstrated (median 6 versus 5; 95% CI of the difference −2 to 3, upper limit above the margin of 2), but median hospital stay was 1 versus 2.5 days (p < 0.0001)

Study: Randomized controlled trial (multicentre, noninferiority — margin missed)

Population: 139 men randomised (70 to monopolar TURP, 69 to GreenLight HPS 120-W vaporisation) in a French multicentre trial; IPSS, uroflowmetry, sexual-function questionnaires and adverse events collected at 1, 3, 6 and 12 months.

Summary: French multicentre 120-W trial (Lukacs 2012, European Urology — RCT, 139 patients): noninferiority on IPSS at 12 months NOT demonstrated (median 6 versus 5; 95% CI of the difference −2 to 3, upper limit above the margin of 2), but median hospital stay was 1 versus 2.5 days (p < 0.0001)

Result: Median IPSS at 12 months was 5 (interquartile range 3–8) for TURP versus 6 (3–9) for vaporisation, and the 95% CI of the difference of the median was −2 to 3; because the upper limit exceeded 2 (the noninferiority margin), noninferiority could not be considered demonstrated. Median length of stay was significantly shorter with vaporisation: 1 (1–2) versus 2.5 (2–3.5) days (p < 0.0001). Uroflowmetry parameters and complications were comparable; sexual outcomes were slightly better with vaporisation without reaching statistical significance.

Watch out: This is the one trial that missed its noninferiority margin on symptoms, and it is carded in full for that reason: the shelf's equivalence claim rests mainly on GOLIATH. Its stay advantage (1 versus 2.5 days) is the largest in the set.

Source: Lukacs B et al. Photoselective vaporization of the prostate with GreenLight 120-W laser compared with monopolar transurethral resection of the prostate: a multicenter randomized controlled trial. European urology. 2012. PMID: 22341632. Registry ID: NCT01043588. MeSH: Aged · Aged, 80 and over · Chi-Square Distribution · Equipment Design · France · Humans · Laser Therapy/adverse effects,instrumentation · Lasers* · Length of Stay · Lower Urinary Tract Symptoms/etiology,pathology,surgery · Male · Middle Aged · Patient Satisfaction · Prostatic Hyperplasia/complications,pathology,surgery · Sexual Dysfunction, Physiological/diagnosis,etiology · Surveys and Questionnaires · Time Factors · Transurethral Resection of Prostate*/adverse effects · Treatment Outcome · Urination Disorders/diagnosis,etiology · Urodynamics

Card 4 — 80-W 5-year trial (Mordasini 2018, Urology — single-centre RCT, 238 treated, 105 with 5-year data): functional improvements similar at 5 years; retreatment 14.3% after vaporisation versus 11.9% after TURP (P = .9)

Study: Randomized controlled trial (single-centre, 5-year follow-up; oldest 80-W device generation)

Population: 238 patients treated with either 80-W GreenLight photoselective vaporisation or monopolar TURP at a single tertiary referral centre in Geneva; primary outcome IPSS, with Qmax, postvoid residual and reoperation rate; at 5 years data were available from 105 patients (44 vaporisation, 61 TURP).

Summary: 80-W 5-year trial (Mordasini 2018, Urology — single-centre RCT, 238 treated, 105 with 5-year data): functional improvements similar at 5 years; retreatment 14.3% after vaporisation versus 11.9% after TURP (P = .9)

Result: After 5 years of follow-up, mean improvements in IPSS, postvoid residual and Qmax were similar in both groups. The retreatment rate was 14.3% in the vaporisation group versus 11.9% in the TURP group (P = .9). Noninferiority of vaporisation to TURP was confirmed in all functional and safety outcomes at 5-year follow-up, in the authors' analysis.

Watch out: Only 105 of 238 treated patients contributed 5-year data — attrition over half the cohort — and this is the superseded 80-W device. Its retreatment figures are the shelf's only long-term durability data and they favour neither arm.

Source: Mordasini L et al. 80-W GreenLight Laser Vaporization Versus Transurethral Resection of the Prostate for Treatment of Benign Prostatic Obstruction: 5-Year Outcomes of a Single-center Prospective Randomized Trial. Urology. 2018. PMID: 29447947. Registry ID: none in the record. MeSH: Aged · Humans · Laser Therapy/adverse effects,instrumentation,methods · Lasers, Solid-State/therapeutic use · Male · Middle Aged · Prospective Studies · Prostate/pathology,surgery · Prostatic Hyperplasia/pathology,surgery · Quality of Life · Reoperation/statistics & numerical data · Transurethral Resection of Prostate/adverse effects,methods · Treatment Outcome · Urinary Bladder Neck Obstruction · Urodynamics

Card 5 — Synthesis — POSSIBLE (benefit): equal symptom relief, faster early recovery, durability watched

Study: Synthesis

Population: 4 independent randomised trials, documented N = 758 randomised: GOLIATH 180-W XPS (281), Capitán 120-W HPS (100), Lukacs 120-W HPS (139), Mordasini 80-W (238 treated; 105 with 5-year data).

Summary: Synthesis — POSSIBLE (benefit): equal symptom relief, faster early recovery, durability watched

Result: Across three laser generations, GreenLight vaporisation relieves symptoms and improves flow to the same degree as TURP — formally noninferior in GOLIATH at 6 months and 2 years, numerically equal in two smaller trials, and short of its noninferiority margin in one. Catheter time and hospital stay are consistently shorter. Complication-free rates at 1–2 years are comparable (83.6–84.6% versus 78.9–80.5% in GOLIATH), and the only 5-year data show retreatment of 14.3% versus 11.9%. The benefit is a recovery advantage at equal efficacy, which is why the stamp is POSSIBLE rather than LIKELY.

Watch out: No trial could blind surgeons or patients, prostate-size subgroups are not separable from these records, and anticoagulated patients — a common reason to choose this laser — were not the studied population in these trials.

Source: Synthesis of the reports carded above; no additional source.