SourceMed · Shelf #90 in the ask interface
The ICD shelf: who actually benefits
Shelf #90 · Heart, vessels, blood pressure & clotting
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2002–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
Does a prophylactic implantable cardioverter-defibrillator reduce total mortality — and in whom?
Balance of the evidence
The ICD story is two true halves. In post-MI and mixed populations the device cut total mortality by roughly a quarter (MADIT-II, SCD-HeFT), earning Class 1, Level A. In modern nonischemic disease on contemporary therapy it halved sudden death and still did not significantly move total mortality (DANISH) — because the deaths it prevents are a smaller share of a better-treated total. The device works; the question the shelf leaves open is which patient, on today’s drugs, still has enough arrhythmic risk to gain. (Panel position: 2022 AHA/ACC/HFSA heart failure guideline — attributed.)
Cards (3)
Card 1 — After MI with EF ≤30%, a prophylactic ICD cut mortality from 19.8% to 14.2%.
Study: Randomised controlled trial, N Engl J Med 2002
Population: 1,232 patients with a prior myocardial infarction and EF ≤0.30, randomly assigned in a 3:2 ratio to an implantable defibrillator (742) or conventional medical therapy (490); invasive electrophysiological testing for risk stratification was not required; average follow-up 20 months
Summary: MADIT-II 2002 — mortality 14.2% vs 19.8% (HR 0.69 , P=0.016) — 1,232 patients with prior MI and EF ≤30%, no arrhythmia or electrophysiology-testing requirement; average follow-up 20 months.
Result: Mortality 14.2% in the defibrillator group vs 19.8% with conventional therapy — HR 0.69 (0.51–0.93) , P=0.016. The effect of defibrillator therapy on survival was similar in subgroup analyses by age, sex, ejection fraction, NYHA class and QRS interval
Watch out: An implanted device, not a drug: procedural risk, inappropriate shocks and generator changes are the standing costs — and the trial predates contemporary drug therapy. The DANISH card below is the modern counterweight
Source: Moss AJ, Zareba W, Hall WJ, et al; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–883. DOI 10.1056/NEJMoa013474. PMID 11907286.
Card 2 — An ICD cut mortality by 23% — while amiodarone, in the same trial, did nothing.
Study: Randomised, placebo-controlled trial, N Engl J Med 2005
Population: 2,521 patients with NYHA class II (70%) or III heart failure and EF ≤35% — the cause ischemic in 52% and nonischemic in 48% — assigned to conventional therapy plus placebo (847), amiodarone (845), or a single-lead ICD (829); median follow-up 45.5 months
Summary: SCD-HeFT 2005 — deaths 22% ICD vs 29% placebo (HR 0.77 , P=0.007); amiodarone 28% (HR 1.06 — no benefit) — 2,521 patients, NYHA II–III, EF ≤35%; median follow-up 45.5 months.
Result: Deaths: 182 (22%) ICD, 240 (28%) amiodarone, 244 (29%) placebo. ICD vs placebo HR 0.77 (97.5% CI 0.62–0.96) , P=0.007 — an absolute decrease in mortality of 7.2 percentage points after five years. Amiodarone vs placebo HR 1.06 (0.86–1.30) , P=0.53 — no benefit. Results did not vary by ischemic or nonischemic cause, but did vary by NYHA class
Watch out: The amiodarone null is stated at full weight: the era’s standard antiarrhythmic drug did not save lives in this trial — the device did
Source: Bardy GH, Lee KL, Mark DB, et al; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–237. DOI 10.1056/NEJMoa043399. PMID 15659722.
Card 3 — In nonischemic heart failure on modern therapy, the ICD halved sudden death — and did not significantly cut total mortality.
Study: Randomised, controlled trial, N Engl J Med 2016
Population: 1,116 patients with symptomatic systolic heart failure not caused by coronary artery disease, EF ≤35%; ICD (556) vs usual clinical care (560); in both groups 58% of patients received CRT, and background therapy included beta-blockers, renin-angiotensin inhibitors and mineralocorticoid antagonists; median follow-up 67.6 months
Summary: DANISH 2016 — all-cause mortality 21.6% vs 23.4% (HR 0.87 , P=0.28 — not significant); sudden cardiac death 4.3% vs 8.2% (HR 0.50 ) — 1,116 patients, 58% with CRT in both groups; median follow-up 67.6 months.
Result: Death from any cause 120 (21.6%) in the ICD group vs 131 (23.4%) in the control group — HR 0.87 (0.68–1.12) , P=0.28, not significant. Sudden cardiac death 24 (4.3%) vs 46 (8.2%) — HR 0.50 (0.31–0.82) , P=0.005
Watch out: Device infection occurred in 4.9% of the ICD group vs 3.6% of controls (P=0.29). A suggestion of greater benefit in younger patients was a subgroup finding, not the headline
Source: Køber L, Thune JJ, Nielsen JC, et al; DANISH Investigators. Defibrillator implantation in patients with nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–1230. DOI 10.1056/NEJMoa1608029. PMID 27571011.