Finding the parathyroid adenoma before surgery — MEASUREMENT ACCURACY: 18F-fluorocholine PET localised far more adenomas than sestamibi in paired comparisons (pooled sensitivity 0.96 versus 0.54, labelled in words on the cards; correct localisation 70% versus 17% in the prospective paired study)

Shelf #9025 · Thyroid & parathyroid

MEASUREMENT ACCURACY — 18F-fluorocholine PET is the more accurate localiser in every paired comparison carded: pooled sensitivity 0.96 versus 0.54 for sestamibi in the meta-analysis subset reporting both (sensitivity labelled in words on the cards), correct localisation 75% overall and 70% versus 17% paired in the prospective study, and lesion-level sensitivity 86% / specificity 93% in secondary/tertiary disease. The sestamibi figures come from selected, often sestamibi-negative referral populations, which flatters the gap.

Stamped: 2026-11-28.

Evidence published: 2020–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with hyperparathyroidism being prepared for parathyroidectomy, how accurately does 18F-fluorocholine PET localise hyperfunctioning parathyroid glands compared with 99mTc-sestamibi imaging and ultrasound, against surgical and histological findings?

Balance of the evidence

MEASUREMENT ACCURACY — composition: 1 meta-analysis of 20 studies, 1 prospective paired study (98 patients imaged, 77 operated), and 1 prospective three-way comparison in secondary/tertiary disease (27 patients, 107 lesions). The meta-analysis found sensitivity 0.97 (range 0.96–0.98) for fluorocholine PET overall, and in the subset reporting both modalities, sensitivity 0.96 (0.94–0.98) for fluorocholine PET versus 0.54 (0.29–0.79) for sestamibi (P < 0.001) (Whitman 2021). In the prospective study, correct localisation was 75% for fluorocholine PET among operated patients, rising from 17% with sestamibi to 70% with fluorocholine PET in the 60 patients who had both (Hope 2021). In dialysis patients with secondary/tertiary disease, lesion-level sensitivity was 86% for fluorocholine PET/CT versus 55% for sestamibi and 62% for ultrasound, with specificity 93%, 80% and 87% respectively (sensitivity and specificity labelled in words on the card) (Chen 2020). Accuracy is localisation accuracy against histology — it is not evidence that PET-first pathways improve cure rates, which no carded study tests.

MeSH: Humans · Technetium Tc 99m Sestamibi · Parathyroid Neoplasms/diagnostic imaging · Choline/analogs & derivatives · Positron-Emission Tomography · Adenoma/diagnostic imaging · Radiopharmaceuticals · Sensitivity and Specificity

Cards (4)

Card 1 — Meta-analysis of 20 studies: fluorocholine PET sensitivity 0.97; in paired studies, sensitivity 0.96 versus 0.54 for sestamibi (Whitman 2021, Journal of Nuclear Medicine)

Study: Meta-analysis of diagnostic accuracy studies

Population: 20 studies of 18F-fluorocholine PET for localisation of hyperparathyroidism, pooled with random-effects and hierarchical summary receiver-operating-characteristic models; the record does not state a pooled patient total. A subset of studies reported both fluorocholine PET and 99mTc-sestamibi in the same patients. Study quality was assessed with QUADAS-2.

Summary: Meta-analysis of 20 studies: fluorocholine PET sensitivity 0.97; in paired studies, sensitivity 0.96 versus 0.54 for sestamibi (Whitman 2021, Journal of Nuclear Medicine)

Result: 18F-fluorocholine PET had a high sensitivity, 0.97 (range, 0.96–0.98), for detection of abnormal parathyroid adenomas (sensitivity labelled in words: sensitivity 0.97). In the subpopulation for which both modalities were reported, fluorocholine PET also had a higher sensitivity, 0.96 (0.94–0.98), than the 0.54 (0.29–0.79) reported for sestamibi (P < 0.001) (sensitivity 0.96 / sensitivity 0.54, labelled in words). The authors conclude the meta-analysis supports fluorocholine PET over sestamibi for localisation in hyperparathyroidism.

Watch out: The paired sestamibi sensitivity of 0.54 is far below sestamibi's performance in unselected first-line populations — these are largely patients referred because conventional imaging had already failed, which stacks the comparison. The record reports sensitivity, not a paired specificity.

Source: Whitman J et al. Assessment and Comparison of 18F-Fluorocholine PET and 99mTc-Sestamibi Scans in Identifying Parathyroid Adenomas: A Metaanalysis. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2021. PMID: 33452040. Registry ID: none in the record. MeSH: Humans · Technetium Tc 99m Sestamibi · Parathyroid Neoplasms/diagnostic imaging · Choline/analogs & derivatives · Positron-Emission Tomography · Adenoma/diagnostic imaging · Radiopharmaceuticals · Sensitivity and Specificity

Card 2 — Prospective paired study: correct localisation 75% for fluorocholine PET; 70% versus 17% against sestamibi in patients who had both (Hope 2021, Journal of Nuclear Medicine — 98 patients)

Study: Prospective diagnostic accuracy study (single-arm, masked readers)

Population: 98 patients with biochemical primary hyperparathyroidism imaged before parathyroidectomy with 18F-fluorocholine PET/MRI at a single centre; 77 subsequently underwent parathyroidectomy and 60 of those also had 99mTc-sestamibi imaging. Each study was read by 3 masked readers per region; lesions were validated against histopathology of surgical specimens.

Summary: Prospective paired study: correct localisation 75% for fluorocholine PET; 70% versus 17% against sestamibi in patients who had both (Hope 2021, Journal of Nuclear Medicine — 98 patients)

Result: For fluorocholine PET in patients who underwent parathyroidectomy, the correct localisation rate based on masked-reader consensus was 75% (95% CI, 0.63–0.82). In patients who had surgery and an available sestamibi study, the correct localisation rate increased from 17% (95% CI, 0.10–0.27) for sestamibi imaging to 70% (95% CI, 0.59–0.79) for fluorocholine PET.

Watch out: Single centre, PET/MRI (not the PET/CT most centres would use), and 21 of 98 imaged patients never reached surgery, so their lesions are unverified. The 17% sestamibi figure again reflects a referral population enriched for difficult glands.

Source: Hope TA et al. Accuracy of 18F-Fluorocholine PET for the Detection of Parathyroid Adenomas: Prospective Single-Center Study. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2021. PMID: 33674400. Registry ID: none in the record. MeSH: Humans · Choline/analogs & derivatives · Parathyroid Neoplasms/diagnostic imaging/surgery · Male · Female · Middle Aged · Prospective Studies · Positron-Emission Tomography · Technetium Tc 99m Sestamibi · Aged · Adenoma/diagnostic imaging/surgery · Radiopharmaceuticals · Adult · Fluorine Radioisotopes

Card 3 — Secondary/tertiary disease on dialysis: lesion-level sensitivity 86% / specificity 93% for fluorocholine PET/CT, versus sensitivity 55% / specificity 80% for sestamibi (Chen 2020, Annals of Nuclear Medicine — 27 patients, 107 lesions)

Study: Prospective diagnostic accuracy study (three-way paired comparison)

Population: 30 dialysis patients with secondary or tertiary hyperparathyroidism prospectively enrolled; 27 underwent all three modalities — dual-phase 18F-fluorocholine PET/CT, dual-phase 99mTc-sestamibi SPECT/CT, and neck ultrasound — followed by parathyroidectomy, giving 107 lesions assessed against histopathology.

Summary: Secondary/tertiary disease on dialysis: lesion-level sensitivity 86% / specificity 93% for fluorocholine PET/CT, versus sensitivity 55% / specificity 80% for sestamibi (Chen 2020, Annals of Nuclear Medicine — 27 patients, 107 lesions)

Result: The lesion-based sensitivities of fluorocholine PET/CT, sestamibi, and ultrasound were 86%, 55%, and 62% respectively (both p < 0.001 for fluorocholine PET/CT against each comparator) (sensitivity labelled in words: sensitivity 86% for fluorocholine PET/CT). Specificities were similar at 93%, 80%, and 87% respectively (specificity 93% / specificity 80% / specificity 87%, labelled in words). Accuracy was 87% for fluorocholine PET/CT versus 59% for sestamibi and 65% for ultrasound (both p < 0.001). Fluorocholine PET/CT sensitivity reached 95% for hyperplastic glands of 200 mg or more.

Watch out: Multigland hyperplasia in dialysis patients is a different localisation problem from a single sporadic adenoma — do not carry the 86% figure across. Twenty-seven patients; lesion-level analysis counts glands, not patients.

Source: Chen YH et al. Preoperative F-18 fluorocholine PET/CT for the detection of hyperfunctioning parathyroid glands in patients with secondary or tertiary hyperparathyroidism: comparison with Tc-99m sestamibi scan and neck ultrasound. Annals of nuclear medicine. 2020. PMID: 32436180. Registry ID: NCT04316845. MeSH: Choline/analogs & derivatives · Female · Humans · Image Interpretation, Computer-Assisted · Male · Middle Aged · Neck/diagnostic imaging · Parathyroid Glands/diagnostic imaging/physiopathology/surgery · Parathyroid Neoplasms/diagnostic imaging/physiopathology/surgery · Positron Emission Tomography Computed Tomography · Preoperative Period · Retrospective Studies · Technetium Tc 99m Sestamibi · Ultrasonography

Card 4 — Synthesis — MEASUREMENT ACCURACY (caution): fluorocholine PET is the better localiser in studied populations; outcome benefit untested

Study: Synthesis

Population: 3 reports: Whitman 2021 (meta-analysis, 20 studies), Hope 2021 (98 patients imaged, 77 operated, 60 paired), Chen 2020 (27 patients, 107 lesions). Documented patient N = 125 across the two primary studies; the meta-analysis record states no pooled patient total.

Summary: Synthesis — MEASUREMENT ACCURACY (caution): fluorocholine PET is the better localiser in studied populations; outcome benefit untested

Result: Every paired comparison favours fluorocholine PET, by wide margins: sensitivity 0.96 versus 0.54 in the meta-analysis paired subset, correct localisation 70% versus 17% prospectively, and lesion-level sensitivity 86% versus 55% in secondary/tertiary disease. The margins are inflated by referral selection — sestamibi performs worst exactly where these studies recruited. No carded study shows that starting with PET improves cure, operating time, or cost.

Watch out: Accuracy against histology in operated patients is subject to verification bias: glands in patients who never reach surgery cannot be confirmed. Radiation, cost, and tracer availability are outside this evidence base.

Source: Synthesis of the reports carded above; no additional source.